Search results for "텔레@upcoin24*"
-
G22WP, HV Relay, 15kV, 50A, SPDT-CO, 24VDC Coil, 1,000,000 Cycles, 17kV Isolation, Screw Terminals, Panel Mount Version
Free Aus Post Shipping for $300 SpendGigavac G22WP, HV Relay, 15kV, 50A, SPDT-CO, 24VDC Coil, 1,000,000 Cycles, 17kV Isolation, Screw Terminals, Panel Mount Version Features Hermetically Sealed (Patented) rated to 85 Deg C High Efficiency Form C DC Coils Gas filled Small and lightweight Flexible package for installation Specification Gigavac Part Number G22WP Main Contact Type SPDT-CO (1 x CO Contacts) Auxiliary Contact Type N/A Coil Voltage 24VDC Load Current 50 Amp Mechanical Life @ 0 Amp 1,000,000 Operations Impulse Withstand 30kV rms Control Input Terminals M6 Mounting Style Panel Mount (M4) Load Voltage Range 15kVDC Standards UL508, NEC 690.11 and 690.12 DC Termination Style Screw Unit Weight 84g Factory Pack Qty 1 Datasheet Product Datasheet
-
DTC1-S/M1-PROG, DIN Rail Mount Temperature/Humidity Controller with Dehumidification Function, Multirange Thermocouple Input, 24VAC/DC, SSR 12VDC Output output
Free Aus Post Shipping for $300 spendFastron DTC1-S/M1-PROG, DIN Rail Mount Temperature/Humidity Controller with Dehumidification Function, Multirange Thermocouple Input, Pt100 Input Jumper Setting, 24VAC/DC, SSR 12VDC Output output Optional converter function 2 Input 1 Output, and 1 Input Two Output Versions available Optional 60 Segment Multi Pattern Program Control feature 4-digit display. Suit most industries including Temperature, Humidity, Pressure (0.5s response) CE Approved Each unit needs just 22.5mm width Din Rail space EC Compliant (Details) Various specials available for unique applications. Specification Fastron Part Number DTC1-S/M1-PROG Control Output SSR 12VDC@30mA Input Multirange K/J/R/S/B/E/T/PT100/Cu50/Linear Voltage Current(Optional)/N/W1/W2 Alarm Relay 3A(Resistive), 1A(Inductive load cos ??=0.4), 240VAC/30VDC Options 60 Step Program Control Mounting Style 22.5 x 75mm Din Rail Mount Supply Voltage 24VAC/DC Termination Style Screw Weight 230g Factory Pack Qty 1 CE Yes Selection Chart PWM Control Wiring Datasheet DTC1 Brochure DTC1User Manual DTC1 User Manual Comms versions Alarm Table DTC1 (Program Control Version) User Manual
-
G18WP, HV Relay, 15kV, 30A, SPDT-CO, 24VDC Coil, 1,000,000 Cycles, 17kV Isolation, Screw Terminals, Panel Mount Version
Free Aus Post Shipping for $300 SpendGigavac G18WP, HV Relay, 15kV, 30A, SPDT-CO, 24VDC Coil, 1,000,000 Cycles, 17kV Isolation, Screw Terminals, Panel Mount Version Features Hermetically Sealed (Patented) rated to 85 Deg C High Efficiency Form C DC Coils Gas filled Small and lightweight Flexible package for installation Specification Gigavac Part Number G18WP Main Contact Type SPDT-CO (1 x CO Contacts) Auxiliary Contact Type N/A Coil Voltage 24VDC Load Current 30 Amp Mechanical Life @ 0 Amp 1,000,000 Operations Impulse Withstand 30kV rms Control Input Terminals M6 Mounting Style Panel Mount (M4) Load Voltage Range 15kVDC Standards UL508, NEC 690.11 and 690.12 DC Termination Style Screw Unit Weight 84g Factory Pack Qty 1 Datasheet Product Datasheet
-
MPFC-PF (PF24R1A), Power Factor Regulator, 24 Step, 1 Phase Measurement, 3 Phase Control, 50-530V 50/60HZ
MPFC-PF (PF12R1A)MPFC-PF (PF24R1A), Power Factor Regulator, 24 Step, 1 Phase Measurement, 3 Phase Control, 50-530V 50/60HZ Single CT Sensing 32nd Harmonic Measurement Isolated Switching of Power Factor Correction Contactors Cos ϕ Setting 0.9 to 0.9 CAP Auto CT Secondary Selection Backlit LCD Display Various Program Combinations IP41 Up to 12 steps Measurement System - Automatic/Manual 50-530VAC Measurement 100-132V / 207-253VAC (L-N) Aux Supply Configurable Alarms Dual Password Protection Programmable Fan Control Programmable 1A/5A CT Ratio Specification Beluk Part Number MPFC-PF / PF24R1A Function Reactive Power Correction Nominal Voltage (Un) 50-530VAC Line to Line Supply Voltage 100-132V / 207-253VAC (L-N), 45-65Hz, max fuse 6A Relay Rating 250VAC/5Amp Static Output Rating (T Models) 8-48VDC / 100mA Internal 2MB Logger Optional 3 x CT Measurement Optional Switch Delay Time 1s - 1200s User Adjustable Alarm 1 x Relay as above Temperature/Fan/THD Alarm 1 x Relay as above Re-connection Delay Time 50 - 1200s User Adjustable Desired Power Factor 0.90 IND - 0.90 CAP Number of Output Relays 12 Smallest Capacitor Current 10mA CT Input Range 15mA - 6 Amp LCD Display Accuracy Voltage +/-0.5%, Frequency +/-0.1%, Power +/-1% Energy Class 1 Phase Angle Error +/- 1% at I > 3% of range Comms Optional Termination Style Screw Weight 700g Certification IEC 654-1 Factory Pack Qty 1 Material of housing PC/ABS Unflammable, according to UL 94 V-0 Enclosure protection IP50 for case, IP20 for terminals Safety According to EN 61 010-1, installation category III Pollution degree 2 Operating Temperature -20...60 °C Datasheet Datasheet User Manual Beluk MPFC Slideshow Comparison with Circuitor Computer Smart II Fast 6 and CX Plus Application Notes Discharge Resistor Usage Power Factor Correction Blog Quick Start Guide(Blog)
$1,478.50
$1,744.63 inclGST -
H-300-2-24, Split Core Hall Effect DC Current Transducer, 0-300 Amp DC, 4-20mA unipolar output, 31mm aperture, 24VDC supply
Free Aus Post Shipping for $300 SpendH-300-2-24, Split Core Hall Effect DC Current Transducer, 0-300 Amp DC, 4-20mA unipolar output, 31mm aperture, 24VDC supply Compact and versatile Split Core DC current sensor, 0-300 Amp DC, 4-20mA Unipolar Output Features ⌀31mm Aperture DC Unipolar Measurement 4-20mA analogue output Busbar, or DIN Rail Mounting Isolated plastic case recognised according to UL94-V0 Advantages High isolation between primary and secondary circuits Easy installation DIN Rail Kit available Applications -Automation Systems Analogue current reading for remote monitoring (e.g. Motor) -Data Loggers Self Powered. Will not drain data logger batteries -Panel Meters Simple connection displays power consumption Specification Fastron Part Number H-300-2-24 Technology DC Hall Effect Current Transducer with Process Output ROHS Yes Supply Voltage 24VDC Nominal Current (DC) 0-300 Amp Response Time < 200mS Output Unipolar 4-20mA Analogue Isolation 4kV (AC, 50Hz, 1 min) Bandwidth DC Mounting Style DIN Rail Mount Operating Temperature Range -40°C / 85°C Accuracy 1% Termination Style Elevator Screw Unit Weight 120g Factory Pack Qty 6 Datasheet Product Datasheet
-
THST18244D-24-2000-RS485, Split Core Bipolar Hall Effect DC Current Transducer, +/-2000Amp DC, +24VDC Supply, 182 x 44 Square aperture, RS485 Modbus RTU Measurement Only
Free Aus Post Shipping for $300 SpendTHST18244D-24-2000-RS485, Split Core Bipolar Hall Effect DC Current Transducer, 2000Amp DC, +24VDC Supply, 182 x 44 Square aperture, RS485 Modbus RTU Measurement Only Compact and versatile Split Core Bipolar DC current sensor, +/-2000 Amp DC, Modbus RS485output Features Modbus RTU (RS485)output 182 x 44mm Aperture Split Core DC Measurement Busbar, or DIN Rail Mounting Isolated plastic case recognised according to UL94-V0 Advantages High isolation between primary and secondary circuits Easy installation DIN Rail Mount Applications -Automation Systems Analogue current reading for remote monitoring (e.g. Motor) -Data Loggers Self Powered. Will not drain data logger batteries -Panel Meters Simple connection displays power consumption Specification Fastron Part Number THST18244D-24-2000-RS485 Technology DC Hall Effect Current Transducer with Processoutput ROHS Yes Supply Voltage 24VDC Nominal Current (DC) 0-2000 Amp Response Time < 200mS Output RS485 Modbus RTU Isolation 2.5kV (AC, 50Hz, 1 min) Bandwidth DC Mounting Style DIN Rail Mount Operating Temperature Range -40°C / 85°C Accuracy 1% Termination Style Elevator Screw Unit Weight 3kg Factory Pack Qty 6 Datasheet Product Datasheet
-
11204696 (AAN5920) MG1 MAHLE - Letrika(Iskra) Alternator, 48VDC 100Amp
Heavy Item - No Free ShippingISKRA LETRIKA 11.204.696 MG1 MAHLE - Letrika(Iskra) AAN5920 Alternator, 48VDC 100Amp OEM 11204696MG1 MAHLE Letrika AAN5920 IA1627 For John Deer 2500E Specification ISKRA (MAHLE) Part Number 11.204.696 MG1 ISKRA/LETRIKA/MAHLE 11204.696 MG1 AAN5920 IA1627 Voltage 48VDC Power 100 Amp Dust Proof YES Module Unit Weight 8.5kg Factory Pack Qty 1 Applications Manufacturer Vehicle Type Engine Ltr Date JOHN DEERE GREENS MOWERS 2500E - Cross Reference Manufacturer Manufacturer P/N JOHN DEERE TCA20101 PRESTOLITE 4400-4700 PRESTOLITE 4417JB PRESTOLITE A0014417JB Spare Parts Pos. Letrika P/N MAHLE P/N Description 2 16.907.059 MGX 258 Drive end bracket 3 16.907.060 MGX 1123 Bearing 4 16.350.603 MGX 953 Stator 5 16.300.295 MGX 949 Bolt 6 16.363.032 MGX 1553 Rotor 7 16.915.618 MGX 922 Pulley 9 16.915.145 MGX 836 Bearing 10 16.915.686 MGX 933 Rectifier 11 16.915.652 MGX 937 Rear-end bracket 13 16.421.041 MGX 1554 Protecting cover 15 16.915.619 MGX 843 Regulator
-
MC740 S SFENC, Panel Mount Measuring Center 3 Phase, Class 0.5 50-500 L-L 50/60Hz Measurement, 240VAC Supply, Ethernet & USB Comms, w/ Supercap
Free Aus Post Shipping for $300 SpendIskra Doo MC740 S SFENC, Panel Mount Measuring Center 3 Phase, Class 0.5 50-500 L-L 50/60Hz Measurement, 240VAC Supply, Ethernet & USB Comms, w/ Supercap Smart Meter Automatic range of nominal current up to 12.5 A (Includes 5A/1A CT Input) and nominal voltage up to 750 V L-N Adjustable tariff clock, display of electric energy consumption in optional currency Optional RS 232/RS 485 communication up to 115,200 bit/s or Ethernet communication Usage The meter is intended for measuring, analysing and monitoring single-phase or three-phase electrical power network. The meter records TRMS value according to the principle of fast sampling of voltage and current signals. A built-in microprocessor calculates measurands (voltage, current, frequency, energy, power, power factor, phase angles, etc.) from the measured signals. Features : Measurement of instantaneous values of more than 140 quantities (U, I, P, Q, S, PF, PA, f, f, MD, energy, energy price by tariffs, etc.). Accuracy class 0.5 or 0.2 (on demand) Measurement of 40 minimal and maximal values in different time periods 32 adjustable alarms Wide frequency range from 16 Hz to 400 Hz RS 232/RS 485 communication up to 115,200 bit/s or Ethernet communication MODBUS and DNP3 communication protocol MMC memory card for setting and upgrading the meter Up to 4 inputs or outputs (analogue outputs, pulse outputs, alarm outputs, tariff inputs) Universal or AC power supply Graphic LCD 128 x 64 dots with illumination Automatic range of nominal current up to 5 A and nominal voltage up to 750 V Adjustable tariff clock, display of electric energy consumption in optional currency Multilingual support User-friendly PC MiQen software 128 samples in one period Measurement of THD on Current or Voltage from 0 to 400% Specification Iskra Doo Part Number MC740 S SFENC Functions Power Quality Meter, Energy Meter, Power Transducer, Network Analyser Supply Voltage 240VAC < 5VA 40-70Hz Nominal Measurement Range 50-500V L-N, 5 Amp 50/60Hz Maximum Measurement Range 800V L-N, 12.5 Amp Alarm N/A (Optional 4 Relays, 32 Alarms, 4 Groups) Analogue Output N/A (Optional 4 x 20mA) Digital Input N/A (Optional 4 x 230VAC/DC,75..130VAC/DC..5..48VAC/DC) Pulse Output N/A (Optional) Pulse Input N/A (Optional) Bistable Switch/Latching Relay Alarm N/A (Optional) Status (Watchdog) Output N/A (Optional) Tariff Input N/A (Optional 4 x 230VAC/DC,75..130VAC/DC..5..48VAC/DC) Accuracy Class 0.5 (I,U,F,PF,θ,THD) (Class 0.2 Optional) Class 1(Active), Class 2 (Reactive) Battery Backup Supercap Real Time Clock 1min/month (30ppm) Internal Memory 8MB MMC up to 2GB Isolation 3.7kV Ethernet RJ45 10/100Mbit/s USB Yes (2400-115200 b/s) RS232/RS485 N/A (optional 2400-115200 b/s) Weight 600g Certification UL, CSA, ROHS Factory Pack Qty 1 EU Directives Degree on electrical equipment designed for use within certain voltage limits URLRS 53/00 (Directive 73/23/EEC on low voltage): SIST EN 61010-1:2002 Safety Requirement for electrical equipment for measurement, control and laboratory use, part1 : general requirement Decree on electromagnetic Compatibility (EMC) URLRS 61/00 (Directive 89/336/EEC on electromagnetic compatibility): SIST EN 61036 item 4.5: 1998 Meters for active energy (class 1 and 2) Safety Protection Class II 600V rms, installation category II 300V rms, installation category III Pollution Degree 2 in compliance with SIST EN 61010-1:2002 Enclosure Material PC/ABS non combustable-self-extinguishability, complying with UL 94 V-0 Enclosure Protection IP52 (IP00 for terminals) in compliance with SIST EN 60529:1997 Resistance to HF Interference Immunity to radiated electrostatic fields IEC/EN 61000-4-3 Immunity to fast transients (burst immunity) IEC/EN 61000-4-4, level 3 Immunity to shock waves IEC/EN 61000-4-5 Radio frequency in common mode IEC/EN 61000-4-6, level 3 Voltage dips and breaks (AC) IEC/EN 61000-4-11 Immunity to damped oscillatory waves IEC/EN 61000-4-12 Conducted and radiated emissions Class B (*) in accordance with EN 55022, EN 55011 (CISPR22, CISPR11) group 1 (*) Except configuration (88 970 1.1 or 88 970 1.2) + (88 970 250 or 88 970 270) + 88 970 241 class A (class B in a metal enclosure) Operating Temperature -20 →+70 °C except CB and XB versions in VDC : -30 →+70 °C (+40 °C in a non-ventilated enclosure) in accordance with IEC/EN 60068-2-1 and IEC/EN 60068-22 Datasheet Product Datasheet User Manual
-
DTC1-R/M1-C5, DIN Rail Mount Temperature/Humidity Controller, Multirange Input, 24VAC/DC, Relay Output, RS485 Modbus RTU
Free Aus Post Shipping for $300 spendFastron DTC1-R/M1-C5, DIN Rail Mount Temperature/Humidity Controller, Multirange Input, 24VAC/DC, Relay Output, RS485 Modbus RTU Optional converter function 2 Input 1 Output, and 1 Input Two Output Versions available Optional 60 Segment Multi Pattern Program Control feature 4-digit display. Suit most industries including Temperature, Humidity, Pressure (0.5s response) CE Approved Each unit needs just 22.5mm width Din Rail space EC Compliant (Details) Various specials available for unique applications. Specification Fastron Part Number DTC1-R/M1-C5 Control Output Relay 3A(Resistive), 1A(Inductive load cos ??=0.4), 240VAC/30VDC Input Multirange K/J/R/S/B/E/T/Linear Voltage Current(Optional)/N/W1/W2/Pt100 Alarm Relay 3A(Resistive), 1A(Inductive load cos ??=0.4), 240VAC/30VDC Options RS485 Comms Mounting Style 22.5 x 75mm Din Rail Mount Supply Voltage 24VAC/DC Termination Style Screw Weight 230g Factory Pack Qty 1 CE Yes ?? Selection Chart PWM Control Wiring Datasheet DTC1 Brochure DTC1User Manual DTC1 User Manual Comms versions Alarm Table DTC1 (Program Control Version) User Manual
-
48x24mm Temperature Controller, 85-265VAC, Type K Thermocouple Input, SSR/Relay output
Free Aus Post Shipping for $300 Spend48x24mm PID Temperature Controller, 85-265VAC, Type K Thermocouple Input, 8VDC, 20mA (SSR) and 250VAC, 1 Amp Relay Output Features Meets UL and IEC standards UL Recognized for 250VAC High breaking capacity of 1.5 kA @ 250VAC Meets the requirements of IEC 60127-2 for Industrial Medical, Aviation Applications Electrical Appliances POwer Supply Adaptors Switch Mode Power Supplies Avionics In-line protection Specification Temtec Part Number 48x24mm Temperature Controller Control Type ON/OFF Relay and SSR Dual Output Supply Voltage 85- 265VAC Relay Rating 250VAC @ 1 Amp SSR Output Rating 8VDC @ 20mA Dimensions 48 x 24 x 75mm Mounting Style Panel Mount 48 x 24mm Operating Temperature Range -5°C / 50°C Unit Weight 80g Factory Pack Qty 10
-
E500M-1052, IEC 61850 SCADA Communication Module for Secure, Elite 500 Series
Elite E500M-1052, IEC 61850 SCADA Communication Module for Secure, Elite 500 Series The meter is intended for measuring, analysing and monitoring single-phase or three-phase electrical power network. The meter records TRMS value according to the principle of fast sampling of voltage and current signals. A built-in microprocessor calculates measurands (voltage, current, frequency, energy, power, power factor, phase angles, etc.) from the measured signals. Elite 500 Features : Measurement of instantaneous values and accumulated energy. Includes Harmonics to the 31st Accuracy class to 0.2S Dual Internal Loggers Measurement of 20 minimal and maximal values in different time periods RS 232/RS 485 communication up to 38400 bit/s or Ethernet communication MODBUS communication protocol Up to 4 inputs or outputs (pulse outputs, alarm outputs, tariff inputs Universal or AC power supply Graphic Colour TFT 320 x 240 pixels (53x70mm) Automatic range of nominal current up to 6 A and nominal voltage up to 500 V Multilingual support User-friendly Free ECon Configuration software
$1,415.00
$1,669.70 inclGST -
787302, E-STOP Safety Relay 24-240VAC/DC, 3 x NO Safety Contacts, 1 x NC Auxiliary Contact, PNOZ X2.8P C 24-240VAC/DC 3n/o 1n/c
Pilz 787302, E-STOP Safety Relay 24-240VAC/DC, 3 x NO Safety Contacts, 1 x NC Auxiliary Contact, PNOZ X2.8P C 24-240VAC/DC 3n/o 1n/c Safety Relay for Monitoring E-STOP Pushbuttons, safety gates and light barriers. Safety Features: Positive guides relay outputs, 3 x NO Safety Contacts, 1 x NC Auxiliary Contact Connection options for: E-Stop Pushbutton Safety Gate limit switch Reset button Light barriers LED Indicator for; Status channel 1/2 Supply Voltage Plug In connection terminals (cage clamp terminal or screw terminal) Redundant Circuit with in built monitoring Failsafe operation in case of component failure Correct Open/Close Operation is tested automatically in each on-off cycle Specification Pilz Part Number 787302, E-STOP Safety Relay PNOZ X2.8P C 24-240VAC/DC 3n/o 1n/c Function E-Stop Relay for E-stop, Gate or Lighting Supply Voltage 24 - 240 VAC/DC Relay Outputs 3 x NO Safety Contacts, 1 x NC Auxiliary Contact maximum Relay Current Safety Contacts 6 Amp, Auxiliary Contact 4 Amp Switch on Delay 340ms Delay on Energisation 10ms Termination Style Screw Weight 250g Certification UL Factory Pack Qty 1 Application Certification In accordance with EN 60947-5-1, EN 60204-1 and VDE 0113-1 Applications 2 in accordance with IEC/EN 61131-2 Protection rating IP40 (Front), IP20 (Rear) Datasheet Product Datasheet User Manual
$697.00
$822.46 inclGST