Search results for "switching solid state relays"
-
TSFNCR-125, 125 Deg C,NC Thermal Switch 10 Deg C Hysteresis, +/-2% Tolerance, Flange Mount, with 90 Deg Raised Terminals
125 Deg C Normally Closed, Thermal Switch 10 Deg C Hysteresis, +/-2% Tolerance, Flange Mount, with 90 Deg Raised Terminals, KSD301, R20 Datasheet Product Datasheet
$10.50
$12.39 inclGST -
TRB-BG33, 2 x NO, 3 Position Key Switch BLACK Latched, 3 Amp @ 240VACVAC, Plastic/Metal, IEC60947-5-1
TRB-BG33, 2 x NO, 3 Position Key Switch BLACK Latched, 3 Amp @ 240VACVAC, Plastic/Metal, IEC60947-5-1 Toggle Switches are used to Toggle between 2 or 3 Digital or Analogue Input Signals or to simply turn off control signals. Widely used for Rugged Industrial Applications Including Critical Machinery requiring safe and reliable repetitive operation by the user. Features : 600V Insulation Rating 240VAC @ 3 Amp 22mm Cutout Standards : IP40 IEC60947-5-1 CE Specification TRENT Part Number TRB-BG33-IP65 Functions 2 Pole, 3 Position Toggle Switch Switch Type Latching 2 x NO Nominal Voltage 240VAC @ 50/60Hz Rated Impulse Voltage 6kV Nominal Current Range AC 3 Amp @240VAC Rated Insulation Voltage 600VAC Humidity 35-85% Approvals CE Standards IEC60947-5-1, IP20 (IP40 Installed) Weight 65g Enclosure Material UL94V0 Factory Pack Qty 1 TRENT(Fastron) Head Office Australia Datasheet Product Datasheet
$5.00
$5.90 inclGST -
HS151DR-PMP6050WP, DIN Mount, Proportional Controller, 480-600VAC 40 Amp @ 40 Deg C, Selection for Burst/Phase Angle, 4-20mA, 0-10V, 0-5V Input, Din Rail Mount, with Overvoltage Protection
HS151DR-PMP6050WP, DIN Mount, Proportional Controller, 480-600VAC 40 Amp @ 40 Deg C, Selection for Burst/Phase Angle, 4-20mA, 0-10V, 0-5V Input, Din Rail Mount, with Overvoltage Protection Selectable Proportional Phase or Burst Control Input Ratings from 25A to 90 Amp @ 170-600 VAC SCR output for heavy industrial loads Zero voltage or Instantaneous turn-on outputs UL/CE/ROHS Compliant Direct bond copper substrate Direct power lead frame Epoxy free design Specification Crydom Part Number HS151DR-PMP6050WP Switching Type Phase Angle or Burst (Selectable) ROHS/CE/UL Yes Control Voltage 0 - 10V/0 - 5V/4 - 20mA Proportional Input (Selectable) Note Requires DC Power Supply for 0-5V/0-10V input modes Load Current 40 Amp (rms) @ 40 Deg C Surge Capability 597 Amp (peak) Special Feature Proportional Controller + SSR + Overvvoltage Protection Mounting Style Panel Mount Load Voltage Range 420-600VAC Dielectric Strength 4kV Termination Style Terminal Plug Unit Weight 1000g Factory Pack Qty 20 Datasheet PMP24 Series Datasheet PMP24 Installation/Wiring Guide HS151DR Datasheet Equivalent Parts Contact Us for Possible Replacement
$355.00
$418.90 inclGST -
FGC1-D25004-230VAC, AC Contactor, 240VAC Control Voltage, 4 Pole 4 x NO, Nominal Current = 25 Amps(AC-3) @ 240/400/500/690V
Fastron Electronics FGC1-D25004-230VAC, AC Contactor, 240VAC Control Voltage, 4 Pole 4 x NO, Nominal Current = 25 Amps(AC-3) @ 240/400/500/690V Contactors are designed to meet the requirements of heavy Duty applications. Contactors may be fitted with auxiliary contacts. Peak current is limited to the value within the contactor making capacity. Features : High contact reliability at low voltages High electrical and mechanical endurance and high switching capacity Four and Three-pole contactors Optional auxiliary contacts Ratings from 6 Amp to 1000 Amp CE, CB Approved Advantages : Saves costs of expensive replacement Long electrical life Reduces watt losses during “ON” condition, saves energy High safety No risk of dangerous voltage Less maintenance and downtime Standard control voltages: 24 V 50/60 Hz, 240 V 50/60 Hz, 415 V 50/60 Hz Specification Fastron Electronics Part Number FGC1-D25004-230VAC Functions 4 Pole Contactor Nominal Voltage 230/400/500/690VAC @ 50/60Hz Current Carrying Capacity as per UL 25 Amp Continuous @ 55 Deg C Main Contacts 4 x NO Trip Delay Time 2-10ms Electrical Life 200,000 Ops Operating Temperature -25 to 55 Deg C Mechanical Operations 10.000,000 Ops Control Voltage 240VAC Power Dissipation 2.3W Approvals UL, CSA Standards IEC/EN 60947-4-1, AS/NZ 61009-1 Weight 200g Enclosure Material UL94 Factory Pack Qty 1 Datasheet Product Datasheet
$65.00
$76.70 inclGST -
K03M-10-240V AC Miniature Contactor 240/400/500/690V, with 240VAC Control Voltage, 4 Pole 4 x NO, Nominal Current = 8.5 Amps
Iskra Doo K03M-10-240V AC Miniature Contactor 240/400/500/690V, with 240VAC Control Voltage, 4 Pole 4 x NO, Nominal Current = 8.5 Amps Capacitor duty contactors are designed to meet the requirements of capacitor duty applications. Contactors are fitted with a block of three auxiliary contacts connected in series with six quick discharge damping resistors, two per each phase. Peak current is limited to the value within the contactor making capacity. Features : High contact reliability at low voltages High electrical and mechanical endurance and high switching capacity Four and Three-pole contactors Optional auxiliary contacts Ratings from 6 Amp to 1000 Amp UL, CSA Approved Advantages : Saves costs of expensive replacement Long electrical life Reduces watt losses during “ON” condition, saves energy High safety No risk of dangerous voltage Less maintenance and downtime Standard control voltages: 24 V 50/60 Hz, 240 V 50/60 Hz, 415 V 50/60 Hz Specification Iskra Doo Part Number K03M-10-240V Functions 4 Pole Contactor 4 x NO Nominal Voltage 230/400/500/690VAC @ 50/60Hz Current Carrying Capacity as per UL 8.5 Amp Continuous @ 55 Deg C Auxiliary Contacts Optional Snap on Trip Delay Time 2-10ms Electrical Life 200,000 Ops Operating Temperature -25 to 40 Deg C Mechanical Operations 10.000,000 Ops Control Voltage 240VAC Power Dissipation 0.36W Approvals UL, CSA, CE Standards IEC/EN 60947-4-1, AS/NZ 61009-1 Weight 200g Enclosure Material UL94 Factory Pack Qty 1 Datasheet Product Datasheet Contactor Catalogue Iskra Contactor Catalogue
$56.00
$66.08 inclGST -
HS259DR + PMP6050WP, DIN Rail Mount, Proportional Controller, 480-600VAC 25 Amp @ 40 Deg C, Selection for Burst/Phase Angle, 4-20mA, 0-10V, 0-5V Input, Din Rail Mount, with Overvoltage Protection
Crydom HS259DR + PMP6050WP, DIN Mount, Proportional Controller, 480-600VAC 25 Amp @ 40 Deg C, Selection for Burst/Phase Angle, 4-20mA, 0-10V, 0-5V Input, Din Rail Mount, with Overvoltage Protection Selectable Proportional Phase or Burst Control Input Ratings from 25A to 90 Amp @ 90-600 VAC SCR output for heavy industrial loads Zero voltage or Instantaneous turn-on outputs UL/CE/ROHS Compliant Direct bond copper substrate Direct power lead frame Epoxy free design Specification Crydom Part Number HS259DR + PMP6050WP Switching Type Phase Angle or Burst (Selectable) ROHS/CE/UL Yes Control Voltage 0 - 10V/0 - 5V/4 - 20mA Proportional Input (Selectable) Note Requires DC Power Supply for 0-5V/0-10V input modes Load Current 25 Amp (rms) Surge Capability 597 Amp (peak) Special Feature Proportional Controller + SSR + Overvoltage Protection Mounting Style Panel Mount Load Voltage Range 420-600VAC Dielectric Strength 4kV Termination Style Terminal Plug Unit Weight 0.4kg Factory Pack Qty 20 Datasheet PMP24 Series Datasheet PMP24 Installation/Wiring Guide GFIN Equivalent Parts Contact Us for Possible Replacement
$335.00
$395.30 inclGST -
HS151DR Kit, Din Rail Mount Heatsink Kit for Single Phase Solid State Relay, 40Amp @ 40 Deg, Requires Assembly, 1.5°C/W
Crydom HS151DR Kit, Din Rail Mount Heatsink for Solid State Relays, 1.5°C/W Features DIN Rail or Panel Mount heat sink types Suitable for SSR Mounting Pre drilled for single or 3 phase SSR Black anodised for professional look Spec Crydom Part Number HS151DR Kit Mounting Type Din Rail Suitable SSR Rating 125 Amp Dimensions (without SSR) L:152.4mm x W:152.4mm x 88.9mm Thermal Impedance 1.5°C/W Load Current @ 40 Deg C 40 Amp Load Current @ 50 Deg C 35 Amp Unit Weight 437g Factory Pack Qty 10 Datasheet Product Datasheet Mounted Datasheet App Notes Why Use SSR's? The inside story Selecting a SSR DC Output SSR's Selecting a Suitable Heatsink Use of Thermal Interface Material How to Verify the Proper Heatsink Effect of Forced Air Cooling Fuse Protection of SSR's Overvoltage Protection "P" Option MOV SSR Reliability Whitepaper 3 Phase Motors and Heating Applications 3 Phase Motor Reversing How to test a SSR SSR Precautions SSR Life Expectancy MTBF ROHS & Reach Statement Heatsink SSR and Heatsink Assemblies
$89.00
$105.02 inclGST -
TSFFNCR-105, 105 Deg C,NC Thermal Switch 10 Deg C Hysteresis, +/-2% Tolerance, Fixed Flange Mount, with 90 Deg Raised Terminals
105 Deg C Normally Closed, Thermal Switch 10 Deg C Hysteresis, +/-2% Tolerance, Fixed Flange Mount, with 90 Deg Raised Terminals, KSD301, R20 Datasheet Product Datasheet
$8.50
$10.03 inclGST -
4CR-1-770, AC Motor Start Relay, 25 Amp Max Pickup Current, 20.6 Amp Minimum Drop Out Current
Sensata 4CR-1-770, AC Motor Start Relay, 25 Amp Max Pickup Current, 20.6 Amp Minimum Drop Out Current Klixon 4CR Current Type Motor starting relay is a compact, high capacity relay, designed for universal application to split phase and capacitor start, single phase motors with start-winding currents up to 25 Amperes. Features : Reliable Operation and long life Wide Range of Pickup and drop out ratings Start-winding Rating - 25 Amps Small size for installation in compact equipment Economical Specification Iskra Doo Part Number 4CR-1-770 Functions Splitphase Motor Start Relay Nominal Current Range 20.6 - 25 Amp RMS Weight 70g Enclosure Material UL94 Factory Pack Qty 1 Datasheet Product Datasheet Application Notes How to Test 4CR Relays - Blog
$85.00
$100.30 inclGST -
KS300, Plastic IP cover for Crydom 3 phase SSR
KS300 Plastic IP cover for Crydom brand 3 phase SSR Product Datasheet
$13.61
$16.06 inclGST -
KNL38G-00 + NPLG, AC Contactor 240/400/500/690V, Overload 304(10s), 320(5s), 350(1s), 900(0.001s) (each pole), 24VDC Control Voltage, 3 Pole 3 x NO, Nominal Current = 38 Amps
Iskra Doo KNL38G-00 + NPLG, AC Contactor 240/400/500/690V, Overload 304(10s), 320(5s), 350(1s), 900(0.001s) (each pole), 24VDC Control Voltage, 3 Pole 3 x NO, Nominal Current = 38 Amps Capacitor duty contactors are designed to meet the requirements of capacitor duty applications. Contactors are fitted with a block of three auxiliary contacts connected in series with six quick discharge damping resistors, two per each phase. Peak current is limited to the value within the contactor making capacity. Features : High contact reliability at low voltages High electrical and mechanical endurance and high switching capacity Four and Three-pole contactors Optional auxiliary contacts Ratings from 6 Amp to 1000 Amp UL, CSA Approved Advantages : Saves costs of expensive replacement Long electrical life Reduces watt losses during “ON” condition, saves energy High safety No risk of dangerous voltage Less maintenance and downtime Standard control voltages: 24 V 50/60 Hz, 240 V 50/60 Hz, 415 V 50/60 Hz Specification Iskra Doo Part Number KNL38G-00 + NPLG Functions 3 Pole Contactor with (3 x NO) with 1 x NO Aux Contacts Nominal Voltage 230/400/500/690VAC @ 50/60Hz Current Carrying Capacity as per UL 38 Amp Continuous @ 55 Deg C Overload Capability 304(10s), 320(5s), 350(1s), 900(0.001s) Auxiliary Contacts 1 x NO (+Optional Snap On 4 Pole NPL3) Trip Delay Time 2-10ms Electrical Life 200,000 Ops Operating Temperature -25 to 55 Deg C Mechanical Operations 10.000,000 Ops Control Voltage 24VDC Power Dissipation 2.3W Approvals UL, CSA Standards IEC/EN 60947-4-1, AS/NZ 61009-1 Weight 200g Enclosure Material UL94 Factory Pack Qty 1 Datasheet Product Datasheet Contactor Catalogue Iskra Contactor Catalogue
$118.00
$139.24 inclGST -
HX21CAB, Contactor SPST-NO 350 AMP, 1500VDC, 24VDC Coil, 38cm Flying leads, with SPST-NO Auxiliary Contact Continuous Duty, IP67, IP69
Gigavac Contactor HX21CAB, Contactor SPST-NO 350 AMP, 1500VDC, 24VDC Coil, 38cm Flying leads, with SPST-NO Auxiliary Contact Continuous Duty, IP67, IP69 Features Hermetically Sealed (Patented) UL1604 for Class I & II Div 2 and Class III for use in hazardous locations IP67 IP69 SAE J1171 External ignition protection ISO8846 Protection against ignition around flammable gasses CE Approved High Efficiency Dual DC Coils - Very low 12,24,48VDC continuous coil power with no EMI emissions or cross-talk on your system control power Ideal for battery powered systems or where low power is needed PWM option provides additional drive control flexibility Built in Coils suppression for all DC Coils Flexible package for installation Integrated safety cover Specification Gigavac Part Number HX21CAB Main Contact Type SPST-NO Auxiliary Contact Type SPST-NO Coil Voltage 24VDC Load Current 350+ Amp Mechanical Life @ 0 Amp 1,000,000 Operations Dielectric at Sea Level (leakage <1mA) 4.3kV rms Control Input Terminals 38cm Flying Leads Aux Contact Terminals 38cm Flying Leads Special Feature N/A Mounting Style Panel Mount (M5) Load Voltage Range 1500VDC Standards UL1604, IP67, IP69 Termination Style M8 Unit Weight 440g Factory Pack Qty 1 Datasheet Product Datasheet
$360.30
$425.15 inclGST