BH-300-2-24, Split Core Hall Effect DC Current Transducer, +/-300 Amp DC, 4-20mA Bipolar output, 31mm aperture, 24VDC supply
BH-300-2-24, Split Core Hall Effect DC Current Transducer, +/-300 Amp DC, 4-20mA Bipolar output, 31mm aperture, 24VDC supply Compact and versatile Split Core DC current sensor, +/-300 Amp DC, 4-20mA Bipolar Output Features ⌀31mm Aperture Split Core DC Bipolar Measurement 4-20mA analogue output Busbar, or DIN Rail Mounting Isolated plastic case recognised according to UL94-V0 Advantages High isolation between primary and secondary circuits Easy installation DIN Rail Mount Applications -Automation Systems Analogue current reading for remote monitoring (e.g. Motor) -Data Loggers Self Powered. Will not drain data logger batteries -Panel Meters Simple connection displays power consumption Specification Fastron Part Number BH-300-2-24 Technology DC Hall Effect Current Transducer with Process Output ROHS Yes Supply Voltage 24VDC Nominal Current (DC) +/-300 Amp DC Response Time < 200mS Output Bipolar 4-20mA Analogue Isolation 2.5kV (AC, 50Hz, 1 min) Bandwidth DC Mounting Style DIN Rail Mount Operating Temperature Range -40°C / 85°C Accuracy 1% Termination Style Elevator Screw Unit Weight 120g Factory Pack Qty 6 Datasheet Product Datasheet
$435.00
$513.30 inclGST -
ESTAmat MH-6N, Power Factor Controller, 6 Step, 90-690V 50/60HZ
Free Aus Post Shipping for $300 SpendVishay Estamat MH-6N Automatic Reactive Power Controller Isolated Switching of Power Factor Correction Contactors Cos ϕ Setting 0.85 to 0.95 CAP Auto CT Secondary Selection Programmable Primary CT Ratio Backlit LCD Display Various Program Combinations IP41 Up to 6 steps Measurement System - Automatic/Manual 230VAC Aux Supply Optional Modbus RS485 Configurable Alarms Dual Password Protection Programmable Fan Control Specification Vishay Part Number Estamat MH-6N Function Reactive Power Correction Nominal Voltage (Un) 415VAC Line to Line (4 Wire) Supply Voltage 230VAC (L-N), 12VA 45-65Hz Relay Rating 250VAC/3Amp Switch Delay Time 2s - 1200s User Adjustable Alarm 1 x Relay as above Temperature Alarm N/A Re-connection Delay Time 2s - 1200s User Adjustable Desired Power Factor 0.85 IND - 0.95 CAP Number of Output Relays 7 Smallest Capacitor Current 50mA CT Input Range 0.05 - 5.5 Amp LCD Display Accuracy Voltage +/-0.5%, Frequency +/-0.1%, Power +/-1% Energy Class 1 Phase Angle Error +/- 1% at I > 3% of range Comms N/A Termination Style Screw Weight 700g Certification IEC 654-1 Factory Pack Qty 1 Material of housing PC/ABS Unflammable, according to UL 94 V-0 Enclosure protection IP40 for case, IP20 for terminals Safety According to EN 61 010-1, installation category III Pollution degree 2 Operating Temperature -20...60 °C Datasheet Product Datasheet User Manual Application Notes Discharge Resistor Usage Power Factor Correction Blog
-
ITZ 10000-SB FLEX ULTRASTAB High Precision Hall Effect Current Sensor, 10000 Amp peak, +/-10V Output, 100mm Aperture, 100-240VAC Supply
Heavy item - No Free ShippingITZ 10000-SB FLEX ULTRASTAB High Precision Hall Effect Current Sensor, 10000 Amp peak, +/-10V Output, 100mm Aperture, 100-240VAC Supply Datasheet Product Datasheet
-
DC-0-200-420-1.0, Hall Effect DC Current Transducer, 0-200 Amp DC, 4-20mA Unipolar output, 24VDC supply
DC-0-200-420-1.0, Hall Effect DC Current Transducer, 0-200 Amp DC, 4-20mA Unipolar output, 24VDC supply Compact and versatile Split Core DC current sensor, 0-200 Amp DC, 4-20 mA Unipolar Output Other measurement ranges available on request Features ⌀20mm Aperture DC Unipolar Measurement 4-20mA analogue output Busbar, or DIN Rail Mounting Isolated plastic case recognised according to UL94-V0 Advantages High isolation between primary and secondary circuits Easy installation DIN Rail Kit available Applications -Automation Systems Analogue current reading for remote monitoring (e.g. Motor) -Data Loggers Self Powered. Will not drain data logger batteries -Panel Meters Simple connection displays power consumption Specification Fastron Part Number DC-0-200-420-1.0 Technology DC Hall Current Sensor with Process Output ROHS Yes Supply Voltage 24VDC Nominal Current (DC) 0-200 Amp Response Time < 1uS Output Unipolar 4-20mA Isolation 2.5kV (AC, 50Hz, 1 min) Bandwidth DC Mounting Style DIN Rail Mount Operating Temperature Range -40°C / 85°C Accuracy 1% Termination Style Elevator Terminals Unit Weight 120g Factory Pack Qty 6 Datasheet Product Datasheet
$385.00
$454.30 inclGST -
GH1, HV Relay/Contactor with RF Screening, 3.5kVDC, 25Amp DC/50/60Hz or 14 Amp RMS(2.5MHz), 9 Amp RMS(16Mhz), 1.5 Amp RMS(32 Mhz), SPDT-CO, 24DC Coil, 2,000,000 Cycles
Free Aus Post Shipping for $300 SpendGigavac GH1, HV Relay/Contactor with RF Screening, 3.5kVDC, 25Amp DC/50/60Hz or 14 Amp RMS(2.5MHz), 9 Amp RMS(16Mhz), 1.5 Amp RMS(32 Mhz), SPST-NO, 24DC Coil, 2,000,000 Cycles Features RF efficient design offers high power handling in asmall package High voltage solder connections provide additionalexternal isolation from PC boards RF screen helps assure interference free operationwhen relays are mounted side by side Vacuum dielectric offers low stable contact resistance Small and lightweight Flexible package for installation Specification Gigavac Part Number GH1 Main Contact Type SPDT-CO Auxiliary Contact Type N/A Coil Voltage 24VDC Load Current 25Amp DC/50/60Hz or 14 Amp RMS(2.5MHz), 9 Amp RMS(16Mhz), 1.5 Amp RMS(32 Mhz) Mechanical Life @ 0 Amp 2,000,000 Operations Impulse Withstand 3.5kV rms Control Input Terminals Solder Tabs Special Feature N/A Mounting Style Panel Mount (M2) Load Voltage Range 3.5kVDC (up to 30Mhz) Standards Termination Style Solder Tabs Unit Weight 24g Factory Pack Qty 1 Datasheet Product Datasheet
-
88970533, Essential Series CT107, 7" HMI Touch Screen(88970534) with M3 Cable, 24VDC, RS485 Modbus RTU
Free Aus Post Shipping for $300 SpendCrouzet 88970533, Essential Series CT107, 7" HMI Touch Screen(88970534) with M3 Cable, 24VDC, RS485 Modbus RTU TFT-LCD resistive touch screen Fan less cooling system 32 bit 600 Mhz or 1 Ghz Cortex-A8 processor Built-in RTC Direct communication with M3 programming port Modbus RS485 protocol (drivers for M3, EVO and em4) Modbus TCP/IP protocol (drivers for M3, EVO and em4) Integrated VNC server Additional functions provided by Crouzet Touch programming software (e-mails,recipe database, enhanced security…) CE mark, cULus listed Specification Crouzet Part Number 88970534 (CT107) + 88970534 Function Human Machine Interface (Touch Screen) + Connection Cable Nominal Voltage 24VDC (19.2 - 28.8VDC) @ 500mA Display Size 7" Resolution 800 x 480 Brightness 300 cd/m² Storage Memory 128MByte RAM Memory 128MByte USB Host USB 2.0 Ethernet N/A Port RS232 COM1 Male Port RS485 COM1 2/4 wires Male, COM3 2 wires Male Voltage Resistance 500VAC (1 Min) Dimensions 200.4 x 146.5 x 34 mm / 7.89 x 5.77 x 1.34” Real Time Clock 5 Years with CR2032 Battery Termination Style Screw Weight 520g Certification CE Factory Pack Qty 1 Over Voltage Category 3 in accordance with IEC/EN 60664-1 Pollution Degree 2 in accordance with IEC/EN 61131-2 Protection rating IP40 (Front), IP20 (Rear) Mechanical Resistance Immunity to vibrations IEC/EN 60068-2-6, test Fc Immunity to shock IEC/EN 60068-2-27, test Ea Resistance to HF Interference Immunity to radiated electrostatic fields IEC/EN 61000-4-3 Immunity to fast transients (burst immunity) IEC/EN 61000-4-4, level 3 Immunity to shock waves IEC/EN 61000-4-5 Radio frequency in common mode IEC/EN 61000-4-6, level 3 Voltage dips and breaks (AC) IEC/EN 61000-4-11 Immunity to damped oscillatory waves IEC/EN 61000-4-12 Conducted and radiated emissions Class B (*) in accordance with EN 55022, EN 55011 (CISPR22, CISPR11) group 1 (*) Except configuration (88 970 1.1 or 88 970 1.2) + (88 970 250 or 88 970 270) + 88 970 241 class A (class B in a metal enclosure) Operating Temperature -20 →+70 °C except CB and XB versions in VDC : -30 →+70 °C (+40 °C in a non-ventilated enclosure) in accordance with IEC/EN 60068-2-1 and IEC/EN 60068-22 Datasheet HMI Touch Datasheet HMI Touch Brochure Software Crouzet Touch Soft V6.00.02.173 Software M3-soft-AC9-V3.1.2.0_ML Remote Control Software CVD_PC_V2_3_01_02 Crouzet Soft EVO EM4 1.12.01.14 Compatibility Built in Communications driver compatible with Millenium 3, Millenium EVO, and EM4 PLC's. See our PLC Section for Pricing and Specification
-
87623573, Totaliser/Counter Electronic 2514 10-30VDC, Counter with two totalizers with Common Input
Crouzet 87623573, Totaliser/Counter Electronic 2514 10-30VDC Counter with two totalizers with Common Input IP65 10-30VDC 6 Digit Display (8mm) 50kHz Maximum Frequency 50. x 24mm Cutout Scaling Factor Rest On Panel or External Inhibit Datasheet Product Datasheet
$389.00
$459.02 inclGST -
KNL90-11-24VAC, AC Contactor 240/400/500/690V, 3 Pole 3 x NO, Nominal Current = 90 Amps, 24VAC Coil
Free Aus Post Shipping for $300 SpendIskra Doo KNL90-11-24VAC, AC Contactor 240/400/500/690V, 3 Pole 3 x NO, Nominal Current = 90 Amps, 24VAC Coil Capacitor duty contactors are designed to meet the requirements of capacitor duty applications. Contactors are fitted with a block of three auxiliary contacts connected in series with six quick discharge damping resistors, two per each phase. Peak current is limited to the value within the contactor making capacity. Features : High contact reliability at low voltages High electrical and mechanical endurance and high switching capacity Four and Three-pole contactors Optional auxiliary contacts Ratings from 6 Amp to 1000 Amp UL, CSA Approved Advantages : Saves costs of expensive replacement Long electrical life Reduces watt losses during “ON” condition, saves energy High safety No risk of dangerous voltage Less maintenance and downtime Standard control voltages: 24 V 50/60 Hz, 240 V 50/60 Hz, 415 V 50/60 Hz Specification Iskra Doo Part Number KNL90-11-24VAC Functions 3 Pole Contactor (3 x NO) Nominal Voltage 230/400/500/690VAC @ 50/60Hz Current Carrying Capacity as per UL 90 Amp Continuous @ 55 Deg C Auxiliary Contacts Optional BFX10-40, 4 Pole Snap On Aux Contacts Trip Delay Time 2-10ms Electrical Life 1,200,000 Ops Operating Temperature -25 to 55 Deg C Mechanical Operations 15,000,000 Ops Control Voltage 24VAC Power Dissipation 9.4W per pole Approvals UL, CSA Standards IEC/EN 60947-4-1, AS/NZ 61009-1 Weight 1.25kg Enclosure Material UL94 Factory Pack Qty 1 Datasheet Product Datasheet Contactor Catalogue Iskra Contactor Catalogue
-
MX11CCB, DC Contactor, Milspec SPST-NC, 150 AMP, 12-48VDC, 24VDC Coil, 122cm Flying leads, IP67, IP69K, 1 x SPST-NO Auxiliary Contact
Free Aus Post Shipping for $300 spendGigavac MX11CCB, DC Contactor Military Grade SPST-NC, 150 AMP, 12-48VDC, 24VDC Coil, 122cm Flying leads, IP67, IP69K, 1 x SPST-NO Auxiliary Contact Features Hermetically Sealed (Patented) rated to 175 Deg C UL1604 for Class I & II Div 2 and Class III for use in hazardous locations IP67 & IP69K Milspec MIL-R-6106 ISO8846 Protection against ignition around flammable gasses CE Approved High Efficiency Dual DC Coils - Very low 12,24,48VDC continuous coil power with no EMI emissions or cross-talk on your system control power Ideal for battery powered systems or where low power is needed PWM option provides additional drive control flexibility Built in Coils suppression for all DC Coils Flexible package for installation Chassi level power terminals Salt Fog MIL-STD-810 Specification Gigavac Part Number MX11CCB Main Contact Type SPST-NO Auxiliary Contact Type SPST-NO Coil Voltage 24VDC Load Current 150 Amp Mechanical Life @ 0 Amp 300,000 Cycles Dielectric at Sea Level (leakage <1mA) 1.5kV rms Control Input Terminals 122cm Flying Leads Aux Contact Terminals N/A Special Feature Hermetically Sealed rated to 175 Deg C Mounting Style Panel Mount (M5) Load Voltage Range 12-48VDC Standards MIL-R-6106, IP67, IP69K, ROHS Termination Style M8 Unit Weight 500g Factory Pack Qty 1 Datasheet Product Datasheet
-
HX241FAB, Contactor SPST-NO 400+ Amp 1500VDC, 48VDC Coil, 38cm Flying leads, with SPST-NO Auxiliary Contact Continuous Duty, IP67, IP69K
Free Aus Post Shipping for $300 spendGigavac HX241FAB, Contactor SPST-NO 400+ Amp 1500VDC, 48VDC Coil, 38cm Flying leads, with SPST-NO Auxiliary Contact Continuous Duty, IP67, IP69K Features Hermetically Sealed (Patented) rated to 175 Deg C UL1604 for Class I & II Div 2 and Class III for use in hazardous locations IP67 & IP69K SAE J1171 External ignition protection ISO8846 Protection against ignition around flammable gasses CE Approved High Efficiency Dual DC Coils - Very low 12,24,48VDC continuous coil power with no EMI emissions or cross-talk on your system control power Ideal for battery powered systems or where low power is needed PWM option provides additional drive control flexibility Built in Coils suppression for all DC Coils Flexible package for installation Chassi level power terminals Salt Fog MIL-STD-810 Specification Gigavac Part Number HX241FAB Main Contact Type SPST-NO Auxiliary Contact Type SPST-NO Coil Voltage 48VDC Load Current 400+ Amp Mechanical Life @ 0 Amp 1,000,000 Operations Dielectric at Sea Level (leakage <1mA) 5.375kV rms Control Input Terminals 38cm Flying Leads Aux Contact Terminals 38cm Flying Leads Special Feature Hermetically Seal rated to 175 Deg C Mounting Style Panel Mount (M5) Load Voltage Range 1500VDC Standards UL1604, IP67, IP69K, SAE J1171, ISO8846, CE Termination Style M8 Unit Weight 440g Factory Pack Qty 1 Datasheet Product Datasheet
-
84871034, Current Monitoring Relay with Hysteresis and T2 time Single Phase 0.1 - 10 Amp EIH Series, 100-240VAC/24VDC Supply, Obsolete, Replaced by 84871130
Free Aus Post Shipping for $300 SpendCrouzet Automation 84871034, Current Monitoring Relay with Hysteresis and T2 time Single Phase 0.1 - 10 Amp EIH Series, 100-240VAC/24VDC Supply, Obsolete, Replaced by 84871130 For Current Monitoring of AC Current from 1 Amp to 20 Amp. Features: 0.1 to 10 Amp Trip Range 0.1 to 10 Second Trip Delay 0 to 100% Hysteresis T2 Hysteresis Delay Time True RMS measurement Specification Crouzet Part Number 84871034 (Single Phase C-Lynx Current Monitoring Relay With SPDT Contacts) Function Current Threshold Montoring Nominal Current 0.1- 10 Amp AC Digital Outputs 1 x C/O Relays, 250VAC/DC @ 8 Amp Min Breaking Current 10mA/5VDC Delay on Threshhold Crossing 0.1 → 3s (0, +10%) Delay on Pickup 600ms Alarm Delay on Time (max) 200ms Reset Time 1500ms Adjustable Hysteresis 5 - 50% of Threshhold Maximum Measurement Cycle Time 30ms/True RMS Measurement Measurement Accuracy 1% Supply Voltage Range 24VAC/DC 48VAC 120/220VAC +/-15% Termination Style Screw Weight 170g Certification CE, UL, CSA, GL, ROHS Factory Pack Qty 1 Over Voltage Category 3 in accordance with IEC/EN 60664-1 Pollution Degree 2 in accordance with IEC/EN 61131-2 Protection rating IP40 (Front), IP20 (Rear) Mechanical Resistance Immunity to vibrations IEC/EN 60068-2-6, test Fc Immunity to shock IEC/EN 60068-2-27, test Ea Resistance to HF Interference Immunity to radiated electrostatic fields IEC/EN 61000-4-3 Immunity to fast transients (burst immunity) IEC/EN 61000-4-4, level 3 Immunity to shock waves IEC/EN 61000-4-5 Radio frequency in common mode IEC/EN 61000-4-6, level 3 Voltage dips and breaks (AC) IEC/EN 61000-4-11 Immunity to damped oscillatory waves IEC/EN 61000-4-12 Conducted and radiated emissions Class B (*) in accordance with EN 55022, EN 55011 (CISPR22, CISPR11) group 1 (*) Except configuration (88 970 1.1 or 88 970 1.2) + (88 970 250 or 88 970 270) + 88 970 241 class A (class B in a metal enclosure) Operating Temperature -20 →+70 °C except CB and XB versions in VDC : -30 →+70 °C (+40 °C in a non-ventilated enclosure) in accordance with IEC/EN 60068-2-1 and IEC/EN 60068-22 Datasheet Product Datasheet
-
88827185 Timer Chronos2 MXR1 Multifunction, 20-30VDC, 20-264VAC, 17.5mm
Free Aus Post Shipping for $300 SpendTimer Chronos2 MXR1 Multifunction, 20-30VDC, 20-264VAC, 17.5mm Multi-range (0.5s - 100hrs) Multi-voltage 12 →240 V AC/DC LED status indicator Possibility of external load connection in parallel to the control input 3-wire PNP sensor compatible Multifunction Timers Includes The Following : Function Ad Delay on energisation by switch, non resettable. 1 relay Function Ah Flash Single Cycle by switch, 1 relay Function N Safeguard Function O Delayed Safeguard Function P Delayed Fixed Length Pulse 1 relay Function Pt Impulse Counter (delay on) 1 relay Function TI inpulse relay Specification Crouzet Part Number 88827103 (Syr-Line Timer SinglePole Double Throw 1 x 8A Multifunction, 12 - 240VAC/DC, 17.5 mm) Function Multifunction Timer A - Ac - At - B - Bw - C - D - Di - H - Ht Nominal Voltage 12 → 240 V AC/DC Digital Output 1 x C/O (DPDT) (Changeover -Single Pole Double Throw-), 250VAC/DC @ 8 Amp Min Breaking Current 10mA/12VDC Timing Ranges Selectable 1s - 10s - 1 min - 10min - 1h, 10h, 100h Minimum Pulse Duration 30ms/100ms with load Repeatability 0.5% Reset Time 120ms Isolation 4kV Repetition Accuracy 0.5% Threshold Adjustment Range 10 → 100 % of the range Termination Style Screw Weight 80g Certification CE, cULus,CCC, ROHS, Reach, WEEE Factory Pack Qty 1 Over Voltage Category 3 in accordance with IEC/EN 60664-1 Pollution Degree 2 in accordance with IEC/EN 61131-2 Protection rating IP40 (Front), IP20 (Rear) Mechanical Resistance Immunity to vibrations IEC/EN 60068-2-6, test Fc Immunity to shock IEC/EN 60068-2-27, test Ea Resistance to HF Interference Immunity to radiated electrostatic fields IEC/EN 61000-4-3 Immunity to fast transients (burst immunity) IEC/EN 61000-4-4, level 3 Immunity to shock waves IEC/EN 61000-4-5 Radio frequency in common mode IEC/EN 61000-4-6, level 3 Voltage dips and breaks (AC) IEC/EN 61000-4-11 Immunity to damped oscillatory waves IEC/EN 61000-4-12 Conducted and radiated emissions Class B (*) in accordance with EN 55022, EN 55011 (CISPR22, CISPR11) group 1 (*) Except configuration (88 970 1.1 or 88 970 1.2) + (88 970 250 or 88 970 270) + 88 970 241 class A (class B in a metal enclosure) Operating Temperature -20 →+70 °C except CB and XB versions in VDC : -30 →+70 °C (+40 °C in a non-ventilated enclosure) in accordance with IEC/EN 60068-2-1 and IEC/EN 60068-22 Datasheet Product Datasheet Cross Reference frt8-m2-w240