RCS-2400-1000 Three-Phase Flexible Current Sensor System(Rogowski Coils):
The RCS-2400 three-phase flexible rope CT from Magnelab converts AC input current of up to 5000 amperes to an AC output of 0.333 volt.
A 9 to 36 VDC power supply is required to operate these coils. The RCS-2400 comes with an integrator which includes flexible strain relief cables.
Included is an 12 inch circumference rope CT with Integrator, and 8 feet of twisted pair (600V) output leads.
Magnelab Coils come with 10 year warranty
Specification
Magnelab Part Number
RCS-2400-1000
Function
AC Current Measurement
Nominal Measurement Current (Ipn)
1000 Amp RMS
Measurement Range
10% - 130% if Ipn
Frequency Measuring Range
50-1500Hz (15th Harmonic)
Operating Voltage
9 - 36VDC
Accuracy
1% from 25 to 1000 Amp
Phase Angle
< 0.5 Degrees
Coil Diameter (⌀)
8 Inch
Coil Circumference
24 Inch
Integrator to Coil Cable
8 Feet Shielded
Maximum Voltage
600V (on bare conductor)
Operating Temperature
-15°C to 65°C
Storage Temperature
-45°C to 80°C
Power Consumption
< 2VA
Overload
20,000 Amp (continuous)
Termination Style
Screw
Weight
1200g
Certification
CE
Factory Pack Qty
1
Certifications
UL Recognized E96927 to IEEE C57.13, CAN/CSA 60044-1
Meets UL STD 61010-1, CAN/CSA C22.2 No. 61010
CE
ROHS
Datasheet
Product Datasheet
Application Notes
RCS/RCT Series Installation Guide
Hanyoung Nux UP12RD-4PA-C, Inductive Proximity Sensor M12 Cylindrical Unshielded, 4mm Sensing Distance (0-3.2mm Set), 12-24VDC PNP Output, Normally Open NO, Connector Type
400HZ Response
12-24VDC Operating voltage
200mA Maximum Output
Built in reverse power, surge, overcurrent protection
50 Meg Ohm Insulation residtance
Specification
Hanyoung Nux Part Number
UP12RD-4PA-C
Sensor Type
Inductive Proximity Sensor M12 Cylindrical Unshielded
No of Wires
3
Material
Stainless Steel Body / Face PBT / Cable Holder Polyester Elastomer
Shielded
NO
Sensing Distance
4mm (0-3.2mm Set)
Frequency Response
400Hz
Output Type
12-24VDC PNP Normally Open
Sensor Thread Size
M8
Standard Target
Ferrous Metal 8 x 8 x 1mm
Approvals
CE
Residual Voltage
1.5V
Current Consumption
6mA
Ambient Operating Temperature
-25 to 70 Deg C
Insulation Resistance
50 Meg Ohm (500V dc in Megohms) between all terminals and case
Dielectric Strength
1500Vac 1 min at 50/60Hz Between all terminals and case
Shock Resistance
500m/s^2, 3 times in each direction
Vibration Resistance
10-55Hz Double amplitude: 1.5mm, 2 hours in each direction X,Y,Z)
Termination
Cable Type (stdnard 2M cabel length), connector cable type, connector type
Colour
NPN:Green, PNP:Navy
Protection Class
IP67
Approvals
CE
Weight
80g
Factory Pack Qty
1
??
Datasheet
Product Datasheet
RCS-3605-VAR, 5 Amp Output, Class 1 Three Phase 500/1000/2500/5000\10000\25000\50000 Amp AC Measurement 12 Inch Diameter Rogowski Coils with Integrator Flexible Current Sensor System (Rogowski Coils):
The RCS-3605 three-phase flexible rope CT from Magnelab converts AC input current of up to 5000 amperes to an AC output of 5 Amp.
A 24VDC Power Supply is included to operate these coils. The RCS-3605 comes with 5 Amp integrator..
Included is an 36 inch circumference rope CT with Integrator, and power supply.
Magnelab Coils come with 10 year warranty
Specification
Magnelab Part Number
RCS-3605-VAR
Function
AC Current Measurement
Nominal Measurement Current (Ipn)
500/1000/2500/5000\10000\25000\50000 Amp RMS Selectable
Measurement Range
10% - 130% if Ipn
Output Range
0-5 Amp
Frequency Measuring Range
50-1500Hz (15th Harmonic)
Operating Voltage
24VDC
Accuracy
1% from 25 to 5000 Amp
Phase Angle
< 0.5 Degrees
Coil Diameter (⌀)
12 Inch
Coil Circumference
36 Inch
Integrator to Coil Cable
8 Feet Shielded
Maximum Voltage
600V (on bare conductor)
Operating Temperature
-15°C to 65°C
Storage Temperature
-45°C to 80°C
Power Consumption
< 2VA
Overload
20,000 Amp (continuous)
Termination Style
Screw
Weight
3500g
Certification
CE
Factory Pack Qty
1
Certifications
UL Recognized E96927 to IEEE C57.13, CAN/CSA 60044-1
Meets UL STD 61010-1, CAN/CSA C22.2 No. 61010
CE
ROHS
Datasheet
Product Datasheet
Application Notes
RCS-VAR Series Installation Guide
Crydom HS211 + D2440G, Panel or slide on Din Rail Heatsink, 3-32VDC Control Input, LED Status, 24-280VAC Output, 25 Amps
Features
Ratings from 25A to 125 Amp @24-280 VAC
SCR output for heavy industrial loads
Zero voltage or instantaneous turn-on outputs
UL/CE/ROHS Compliant
Direct bond copper substrate
Direct power lead frame
Epoxy free design
Panel Mount
Din Rail Mount
Spec
Part Number
HS211 + D2440G
Switching Type
Zero Crossing
ROHS/CE/UL
Yes
Control Voltage
4-32VDC
Load Current
25 Amp (rms) @ 40 Deg C
Surge Capability
597 Amp (peak)
Special Feature
LED Status Indicator
Mounting Style
Din Rail or Panel Mount
Load Voltage Range
24-280VAC
Max Non Repetitive Peak Voltage
600 Vp
Termination Style
Screw Terminals
Dimensions
L:81mm x W:45mm x D:73.4mm
Unit Weight
296g
Factory Pack Qty
20
Datasheet
HS211
Series 1 AC
Notifications
Please note Changes from Gen 3 to Gen 4 (current) package design here
App Notes
Why Use SSR's?
The inside story
Selecting a SSR
DC Output SSR's
Selecting a Suitable Heatsink
Use of Thermal Interface Material
How to Verify the Proper Heatsink
Effect of Forced Air Cooling
Fuse Protection of SSR's
Overvoltage Protection "P" Option MOV
SSR Reliability Whitepaper
3 Phase Motors and Heating Applications
3 Phase Motor Reversing
How to test a SSR
SSR Precautions
SSR Life Expectancy MTBF
ROHS & Reach Statement
Heatsink
SSR and Heatsink Assemblies
RCS-1200-1000 0.333V, 3 Phase 1000Amp AC Measurement 4 Inch ⌀ Rogowski Coils with Integrator, Class 1 Flexible Current Sensor System:
The RCS-1200 three-phase flexible rope CT from Magnelab converts AC input current of up to 5000 amperes to an AC output of 0.333 volt.
A 9 to 36 VDC power supply is required to operate these coils. The RCS-1200 comes with an integrator which includes flexible strain relief cables.
Included is an 12 inch circumference rope CT with Integrator, and 8 feet of twisted pair (600V) output leads.
Magnelab Coils come with 10 year warranty
Suitable Alternative to Solar Edge CTRC-07500-1000
Specification
Magnelab Part Number
RCS-1200-1000
Function
AC Current Measurement
Nominal Measurement Current
1000 Amp RMS
Measurement Range
10% - 130% if Ipn
Frequency Measuring Range
50-1500Hz (15th Harmonic)
Operating Voltage
9 - 36VDC
Accuracy
1% from 25 to 1000 Amp
Phase Angle
< 0.5 Degrees
Coil Diameter (⌀)
4 Inch
Coil Circumference
12 Inch
Integrator to Coil Cable
8 Feet Shielded
Maximum Voltage
600V (on bare conductor)
Operating Temperature
-15°C to 65°C
Storage Temperature
-45°C to 80°C
Power Consumption
< 2VA
Overload
20,000 Amp (continuous)
Termination Style
Screw
Weight
1200g
Certification
CE
Factory Pack Qty
1
Certifications
UL Recognized E96927 to IEEE C57.13, CAN/CSA 60044-1
Meets UL STD 61010-1, CAN/CSA C22.2 No. 61010
CE
ROHS
Datasheet
Product Datasheet
Application Notes
RCS/RCT Series Installation Guide
Magnelab HCT-0024-250, Split Core DC Hall Effect Current Sensor, 250 Amp, +/-4V Output, Split Core 24mm Aperture, X = 1%
Features
Open loop transducer using Hall effect
Compact and versatile
Panel mounting-Horizontal or Vertical
Insulated plastic case recognized according to UL 94-V0
Advantages
Very good linearity
Very good accuracy
Low temperature drift
Wide frequency bandwidth
Very low insertion losses
High immunity to external interference
Current overload capability
Low power consumption
Applications
Static converters for DC motor drives
Battery supplied applications
Uninterruptible Power Supplies (UPS)
Switched Mode Power Supplies (SMPS)
Power supplies for welding applications.
Specification
Magnelab Part Number
HCT-0024-250
Technology
Split Core Open Loop Hall Effect
Aperture
ø24mm
ROHS
Yes
Supply Voltage
+/-15 VDC Bipolar, Isolated
Load Current (RMS + DC)
250 Amp
Measurement Range
+/-375 Amp
Output
+/-4 V
Isolation
4 kV
Bandwidth
DC
Mounting Style
Panel Mount
Operating Temperature Range
-25°C / 75°C
Accuracy
1%
Termination Style
Flying Lead
Unit Weight
400g
Factory Pack Quantity
10
Datasheet
Product Datasheet
Crydom HS211 + HD4850, Panel or slide on Din Rail Solid State Relay, 3-32VDC Control Input, 90-530VAC Output, 25 Amps
Features
Ratings from 25A to 125 Amp @48-530 VAC
SCR output for heavy industrial loads
Zero voltage or instantaneous turn-on outputs
UL/CE/ROHS Compliant
Direct bond copper substrate
Direct power lead frame
Epoxy free design
Panel Mount
Din Rail Mount
Spec
Part Number
HS211 + HD4850
Switching Type
Zero Crossing
ROHS/CE/UL
Yes
Control Voltage
3-32VDC
Load Current
23 Amp (rms) @ 40 Deg C
Surge Capability
597 Amp (peak)
Special Feature
N/A
Mounting Style
Din Rail or Panel Mount
Load Voltage Range
48-530VAC
Max Non Repetitive Peak Voltage
600 Vp
Termination Style
Screw Terminals
Dimensions
L:81mm x W:45mm x D:73.4mm
Unit Weight
296g
Factory Pack Qty
20
Datasheet
HS211
HD4850
Notifications
Please note Changes from Gen 3 to Gen 4 (current) package design here
App Notes
Why Use SSR's?
The inside story
Selecting a SSR
DC Output SSR's
Selecting a Suitable Heatsink
Use of Thermal Interface Material
How to Verify the Proper Heatsink
Effect of Forced Air Cooling
Fuse Protection of SSR's
Overvoltage Protection "P" Option MOV
SSR Reliability Whitepaper
3 Phase Motors and Heating Applications
3 Phase Motor Reversing
How to test a SSR
SSR Precautions
SSR Life Expectancy MTBF
ROHS & Reach Statement
Heatsink
SSR and Heatsink Assemblies
Fastron Electronics FGC1-K12004-24VDC, AC Miniature Contactor 240/400/500/690V, with 24VDC Control Voltage, 4 Pole 4 x NO, Nominal Current = 12 Amps
Contactors are designed to meet the requirements of heavy Duty applications. Contactors may be fitted with auxiliary contacts. Peak current is limited to the value within the contactor making capacity. capacity.
Features :
High contact reliability at low voltages
High electrical and mechanical endurance and high switching capacity
Four and Three-pole contactors
Optional auxiliary contacts
Ratings from 6 Amp to 1000 Amp
UL, CSA Approved
Advantages :
Saves costs of expensive replacement
Long electrical life
Reduces watt losses during “ON” condition, saves energy
High safety
No risk of dangerous voltage
Less maintenance and downtime
Standard control voltages: 24 V 50/60 Hz, 240 V 50/60 Hz, 415 V 50/60 Hz
Specification
Fastron Electronics Part Number
FGC1-K12004DC-24VDC
Functions
4 Pole Contactor 4 x NO
Nominal Voltage
230/400/500/690VAC @ 50/60Hz
Current Carrying Capacity as per UL
12 Amp Continuous @ 55 Deg C
Auxiliary Contacts
Optional Snap on
Trip Delay Time
2-10ms
Electrical Life
200,000 Ops
Operating Temperature
-25 to 40 Deg C
Mechanical Operations
10.000,000 Ops
Control Voltage
24VDC
Power Dissipation
0.36W
Approvals
UL, CSA, CE
Standards
IEC/EN 60947-4-1, AS/NZ 61009-1
Weight
200g
Enclosure Material
UL94
Factory Pack Qty
1
Datasheet
Product Datasheet
Contactor Catalogue
Fastron-Trent Low Voltage Switch Gear Catalogue
Accessories
Auxiliary Contacts
Thermal Overload Relays
RC Networks and Suppression Diodes
Magnelab DCT-0010-025, AC CT, Self Powered, 25 Amp Average RMS 0-5V output
Features
Split Core
0-5V Average RMS Output
Cable Mounting
Self Powered
Isolated plastic case recognised according to UL94-V0
Advantages
Large aperture for cable up to ⌀ 16mm
High isolation between primary and secondary circuits
Easy installation
Applications
Current Measurement
Energy Management
Motor Control
Actuators
Lamp Failure
Specification
Magnelab Part Number
DCT-0010-025
Technology
AC Current Transformer
Supply Voltage
Self Powered
Load Current (RMS)
25 Amp
Maximum Measurement Current (RMS)
37.5 Amp
Output
0-5V (Average RMS) 5% Ripple
Response Time
300ms
Isolation
2.5kV (AC, 50Hz, 1 min)
Voltage Rating
Cat III 600VAC
Bandwidth
50/60Hz
Mounting Style
Cable Mount
Operating Temperature Range
-20°C / 50°C
Accuracy
2%
Aperture
⌀ 10mm
Termination Style
Screw
Approvals
CE,UL,ROHS2
Unit Weight
70g
Factory Pack Qty
6
Datasheet
Product Datasheet
Crydom B512F-2T, Single Phase Half Controlled Rectifier Bridge, 25 Amp, 240VAC Line
Features
For AC or DC Variable Voltage Output Up to 15KW
Electrically insulated base plate
Industrial standard package
2500V Isolation
UL Recognized E72445
Applications
Power Supplies
Rectifier for drives applications
Rectifiers for UPS
Battery Chargers
Spec
Crydom Part Number
B512F-2T
AC Line voltage
240V
Device Configuration
Single Phase Half Controlled Rectifier Bridge,
DC Output @ 85 Deg C
25 Amp
Package Size
W:31.7mm L:63.5mm D:19.7mm
Itsm
250 A
VF
1.65V
Tj(max)
125°C
rF
Not Published
Terminals
Faston (6.3mm)
Hole Centres
48.2mm (M5)
Gate Terminals
Faston (6.3mm)
R th(j-c)
0.9°C/W
R th(c-h)
Not Published
Weight
42.5g
Isolation
2.5kV
Factory Pack Qty
20
Certification
UL Listed
Crydom Headquarters
United States
Datasheet
Product Datasheet
Alternatives
See B514F-2T, B612F-2T, B614F-2T or PSD51/18 for higher rated equivalents
App Notes
Why Use SSR's?
The inside story
Selecting a SSR
DC Output SSR's
Selecting a Suitable Heatsink
Use of Thermal Interface Material
How to Verify the Proper Heatsink
Effect of Forced Air Cooling
Fuse Protection of SSR's
Overvoltage Protection "P" Option MOV
SSR Reliability Whitepaper
3 Phase Motors and Heating Applications
3 Phase Motor Reversing
How to test a SSR
SSR Precautions
SSR Life Expectancy MTBF
ROHS & Reach Statement
Heatsink
SSR and Heatsink Assemblies
Iskra IKD225-20-R-24VAC/DC, Single Pole 1 x NO Modular Contactor 240VAC, 25 Amp, 24VAC/DC Control Voltage, 40-500Hz, Hum Free with Manual Override, Can Replace MC-25-240-R-2NO
Features
25 Amp (rms) @ 240VAC
DIN Rail Mount
Slim package
CE Compliant to IEC 60664
IP20
Specification
Fastron Part Number
IKD225-20-R-24VAC/DC
Switching Type
2 x SPST NO
Approvals
CE
Coil Voltage
24VAC/DC
Load Rating
25 Amp
Special Feature
Hum Free, Manual Override
Mounting Style
DIN Rail Mount
Load Voltage Range
24VAC/DC
Isolation
4kV
Termination Style
Screw
Unit Weight
295g
Factory Pack Qty
20
Datasheet
Contactor Datasheet