Search results for "TG@tetherzon$*오다집수수료코인이체구입"
-
FESCT-3000-1000-100mV, 1000Amp 100mV Class 1 Measurement Split Core CT's, 1M Flying Leads, HY2.0 Connection, 76x127mm Aperture
Fastron Electronics FESCT-3000-1000, 1000Amp 100mV Class 1 Measurement Split Core CT's, 1M Flying Leads, 76x127mm Aperture Features Quick Release Split Core System 1m Flying Leads Mounting Feet Supplied Self Powered Rated System Voltage 0.60/3kV Applications US Based Metering Equipment Energy Monitoring AC Power Control Systems Power Factor Correction Power Quality Measurements Specification Fastron Electronics Part Number FESCT-3000-1000 Technology Split Core AC Current Transformer Ratio 1000/100mV Aperture Size 76x127mm VA Rating N/A Accuracy Class Class 1 Output 100mVAC (+20%) Isolation 3kV (AC, 50Hz, 1 min) Bandwidth 50-60Hz Mounting Style Cable Mount/Busbar Mount Operating Temperature Range -15°C / 55°C Continuous Current (max) 1000Amp x 1.2 Termination Style Terminals Unit Weight 3000g Factory Pack Qty 9 Datasheet Product Datasheet Installation Guide FESCTHY Install Guide
$208.00
$245.44 inclGST -
FDV-500-V05-24, DC Voltage Transducer, Din Rail Mount, 0-500VDC, 5V output, 24VDC Supply Voltage, 150mS Response
Free Aus Post Shipping for $300 SpendFastron FDV-500-V05-24, DC Voltage Transducer, Din Rail Mount, 0-500VDC, 5V output, 24VDC Supply Voltage, 150mS Response 150mS Response Time PC 94 UL V0 Input signals can be converted to insulated 5V DC output (for voltage output type) Each unit needs just 22.5 x 114 mm depth DIN Rail cabinet space Specification Fastron Part Number FDV-500-V05-24 Analogue Output 5V Input 0 - 500VDC Measurement Range 120% Overload 150% Continuous Operating Temperature -30 - 70°C Operating Voltage 24VDC +/-15% Accuracy 1% Response Time 150mS Voltage Isolation (1 min) 2.5kV Termination Style Screw Mounting Style DIN Rail Mount Safety CE, UL94V0 Weight 170g Factory Pack Qty 1 Datasheet Product Datasheet
Free Aus Post Shipping for $300 Spend$265.00
$312.70 inclGST -
FESCTHY-51-1000-100mA, 1000Amp measurement Split Core CT's, w/1M Flying Leads, HY2.0 Connection, 51x51mm Aperture
Fastron Electronics FESCTHY-51-1000-100mA, 1000Amp measurement Split Core CT's, w/1M Flying leads, 51x51mm Aperture Features Quick Release Split Core System 1m Flying Leads Mounting Feet Supplied Self Powered Rated System Voltage 0.60/3kV Applications US Based Metering Equipment Energy Monitoring AC Power Control Systems Power Factor Correction Power Quality Measurements Specification Fastron Electronics Part Number FESCTHY-51-1000-100mA Technology Split Core AC Current Transformer Ratio 1000/100mA Aperture Size 51 x 51mm VA Rating N/A Accuracy Class Class 1 Output 100mAAC (+20%) Isolation 3kV (AC, 50Hz, 1 min) Bandwidth 50-60Hz Mounting Style Cable Mount/Busbar Mount Operating Temperature Range -15°C / 55°C Continuous Current (max) 1000Amp x 1.2 Termination Style 1M Twisted Pair 0.34mm^2 Unit Weight 950g Factory Pack Qty 9 Datasheet Product Datasheet Application Notes Installation Guide
$126.00
$148.68 inclGST -
SCT-Y36-300A-100mV, 300A/100mV Measurement, Class 1 Split Core CT's, 36mm Aperture, with HY2.0 Connector for Eastron Meter EasyClick System
Fastron Electronics SCT-Y36-300A-100mV, 300A/100mV Measurement, Class 1 Split Core CT's, 36mm Aperture, with HY2.0 Connector for Eastron Meter EasyClick System Features Quick Release Split Core System Cable Mount 100mVmp Output Self Powered Rated System Voltage 0.60/3kV 0.9M Flying Leads with HY-2.0 Connector Applications Eastron Modular Metering Equipment Energy Monitoring Load Balancing Power Quality Measurements Specification Fastron Part Number SCT-Y36-300A-100mV Technology Split Core AC Current Transformer Ratio 300/100mV Aperture Size ø 36 mm VA Rating 1VA Accuracy Class Class 1 Output 100mV (+20%) Isolation 3kV (AC, 50Hz, 1 min) Bandwidth 50-60Hz Mounting Style Cable Mount/Busbar Mount Operating Temperature Range -15°C / 45°C Continuous Current (mVx) 300Amp x 1.2 Termination Style 0.9M Flying leads with HY-2.0 Connector Unit Weight 100g Factory Pack Qty 9 Datasheet Product Datasheet Application Notes Installation Guide CRJ-31 Connector User Guide
$69.00
$81.42 inclGST -
SCT-Y36-600A-100mV, 600A/100mV Measurement, Class 1 Split Core CT's, 36mm Aperture, with HY2.0 Connector for Eastron Meter EasyClick System
Fastron Electronics SCT-Y36-600A-100mV, 600A/100mV Measurement, Class 1 Split Core CT's, 36mm Aperture, with HY2.0 Connector for Eastron Meter EasyClick System Features Quick Release Split Core System Cable Mount 100mVmp Output Self Powered Rated System Voltage 0.60/3kV 0.9M Flying Leads with HY-2.0 Connector Applications Eastron Modular Metering Equipment Energy Monitoring Load Balancing Power Quality Measurements Specification Fastron Part Number SCT-Y36-600A-100mV Technology Split Core AC Current Transformer Ratio 600/100mV Aperture Size ø 36 mm VA Rating 1VA Accuracy Class Class 1 Output 100mV (+20%) Isolation 3kV (AC, 50Hz, 1 min) Bandwidth 50-60Hz Mounting Style Cable Mount/Busbar Mount Operating Temperature Range -15°C / 45°C Continuous Current (mVx) 600Amp x 1.2 Termination Style 0.9M Flying leads with HY-2.0 Connector Unit Weight 170g Factory Pack Qty 9 Datasheet Product Datasheet Application Notes Installation Guide CRJ-31 Connector User Guide
$69.00
$81.42 inclGST -
AT-DV6-D-1, AC Voltage Transducer, 300VDC, 22-60VAC/DC Aux, 4-20mA output
Free Aus Post Shipping for $300 SpendCurrent Transducer, AT-DV6-D-1, AC Voltage Transducer, 300VDC, 22-60VAC/DC Aux, 4-20mA output Adjustable Zero and Span Setting 250mS Response Time PC 94 UL V0 Input signals can be converted to insulated 4 to 20 mA DC output (for direct current output type) or 0-10V/0-5V (For Direct Voltage Type) Each unit needs just 50mm x 120mm depth DIN Rail cabinet space Specification Fastron Electronics Part Number AT-DV6-D-1 Control Output 4-20mA Input 0-300VDC Over Range x 1.2 Operating Temperature 0 - 60°C Load Voltage 22-60VAC/DC Span Adjustment Range +/-10% Zero Adjustment Range +/-5% Termination Style Screw Mounting Style DIN Rail Mount Case Material PC - UL 94 V0 Weight 170g Factory Pack Qty 1 Datasheet Product Datasheet
Free Aus Post Shipping for $300 Spend$209.00
$246.62 inclGST -
FDV-15-V10-24, Battery DC Voltage Transducer, Din Rail Mount, 0-15VDC, 0-10V output, 24VDC Supply Voltage, 150mS Response
Fastron FDV-15-V10-24, Battery DC Voltage Transducer, Din Rail Mount, 0-15VDC, 0-10V output, 24VDC Supply Voltage, 150mS Response 150mS Response Time PC 94 UL V0 Input signals can be converted to insulated 5V DC output (for voltage output type) Each unit needs just 22.5 x 114 mm depth DIN Rail cabinet space Specification Fastron Part Number FDV-15-V10-24 Analogue Output 0-10V Input 0-15VDC Measurement Range 120% Overload 150% Continuous Operating Temperature -30 - 70°C Operating Voltage 24VDC +/-15% Voltage Isolation (1 min) 2.5kV Accuracy 1% Response Time 150mS Termination Style Screw Mounting Style DIN Rail Mount Safety CE, UL94V0 Weight 170g Factory Pack Qty 1 Datasheet Product Datasheet
$265.00
$312.70 inclGST -
SCT-F36-500, 0.333V, 500Amp Measurement, Class 1 Split Core CT's Class 1, 35mm Aperture
Fastron Electronics SCT-F36-500, 0.333V, 500Amp measurement Split Core CT's Class 1, 35mm Aperture Features Quick Release Split Core System Cable Mount 0.333V Output Self Powered Rated System Voltage 0.60/3kV 0.9M Flying Leads Applications US Based Metering Equipment Energy Monitoring AC Power Control Systems Power Factor Correction Power Quality Measurements Specification Fastron Part Number SCT-F36-500 Technology Split Core AC Current Transformer Ratio 500/0.333V Aperture Size ø 35 mm VA Rating N/A Accuracy Class Class 1 Output 0.333V (+20%) Isolation 3kV (AC, 50Hz, 1 min) Bandwidth 50-60Hz Mounting Style Cable Mount/Busbar Mount Operating Temperature Range -15°C / 45°C Continuous Current (max) 500Amp x 1.2 Termination Style 0.9M Flying leads Unit Weight 400g Factory Pack Qty 9 Datasheet Product Datasheet Stocked Split Core CT's Listing Application Notes Installation Guide Types of Current Transformers - Blog Cable Losses and CT's High Accuracy or High Burden Requirements for CT's
$66.50
$78.47 inclGST -
SCT-F36-300-5A, 5 Amp, 300Amp Measurement, Class 1 Split Core CT's
Fastron Electronics SCT-F36-300-5A, 5 Amp, 300Amp measurement Split Core CT's Features Quick Release Split Core System Cable Mount 5 Amp Output Self Powered Rated System Voltage 0.60/3kV 0.9M Flying Leads Applications US Based Metering Equipment Energy Monitoring AC Power Control Systems Power Factor Correction Power Quality Measurements Specification Fastron Part Number SCT-F36-300-5A Technology Split Core AC Current Transformer Ratio 300/5 Amp Aperture Size ø 35 mm VA Rating N/A Accuracy Class Class 1 Output 5 Amp (+20%) Isolation 3kV (AC, 50Hz, 1 min) Bandwidth 50-60Hz Mounting Style Cable Mount/Busbar Mount Operating Temperature Range -15°C / 45°C Continuous Current (max) 300Amp x 1.2 Termination Style 0.9M Flying leads Unit Weight 400g Factory Pack Qty 9 Datasheet Product Datasheet Stocked Split Core CT's Listing Application Notes Installation Guide Types of Current Transformers - Blog Cable Losses and CT's High Accuracy or High Burden Requirements for CT's
$66.50
$78.47 inclGST -
FESCTHY-51-1000-100mA, 1000Amp measurement Split Core CT's, w/1M Flying Leads, HY2.0 Connection, 51x51mm Aperture
Fastron Electronics FESCTHY-51-1000-100mA, 1000Amp measurement Split Core CT's, w/1M Flying leads, 51x51mm Aperture Features Quick Release Split Core System 1m Flying Leads Mounting Feet Supplied Self Powered Rated System Voltage 0.60/3kV Applications US Based Metering Equipment Energy Monitoring AC Power Control Systems Power Factor Correction Power Quality Measurements Specification Fastron Electronics Part Number FESCTHY-51-1000-100mA Technology Split Core AC Current Transformer Ratio 1000/100mA Aperture Size 51 x 51mm VA Rating N/A Accuracy Class Class 1 Output 100mAAC (+20%) Isolation 3kV (AC, 50Hz, 1 min) Bandwidth 50-60Hz Mounting Style Cable Mount/Busbar Mount Operating Temperature Range -15°C / 55°C Continuous Current (max) 1000Amp x 1.2 Termination Style 1M Twisted Pair 0.34mm^2 Unit Weight 950g Factory Pack Qty 9 Datasheet Product Datasheet Application Notes Installation Guide
$126.00
$148.68 inclGST -
FESCTHY-6000-3000-100mV, 3000Amp 100mV Class 1 Measurement Split Core CT's, w/terminals, 153x157mm Aperture
Fastron Electronics FESCTHY-6000-3000-100mV, 3000Amp 100mV Class 1 Measurement Split Core CT's, w/terminals, 153x157mm Aperture Features Quick Release Split Core System 1m Flying Leads Mounting Feet Supplied Self Powered Rated System Voltage 0.60/3kV Applications US Based Metering Equipment Energy Monitoring AC Power Control Systems Power Factor Correction Power Quality Measurements Specification Fastron Electronics Part Number FESCTHY-6000-3000-100mV Technology Split Core AC Current Transformer Ratio 3000/100mV Aperture Size 153x157mm VA Rating N/A Accuracy Class Class 1 Output 100mVAC (+20%) Isolation 3kV (AC, 50Hz, 1 min) Bandwidth 50-60Hz Mounting Style Cable Mount/Busbar Mount Operating Temperature Range -15°C / 55°C Continuous Current (max) 3000Amp x 1.2 Termination Style Terminals Unit Weight 3000g Factory Pack Qty 9 Datasheet Product Datasheet Application Notes Installation Guide
$239.00
$282.02 inclGST -
GT-AV6-A-4, AC Voltage Transducer, 0-300V AC input, 100-240VAC/DC aux, 0-10V Average RMS output
Fastron Electronics GT-AV6-A-1, AC Voltage Transducer, 0-300V AC input, 100-240VAC/DC aux, 0-10V Average RMS output Adjustable Zero and Span Setting 250mS Response Time PC 94 UL V0 Input signals can be converted to insulated 4 to 20 mA DC output (for direct current output type) Each unit needs just 22.5 x 114 mm depth DIN Rail cabinet space Specification Fastron Electronics Part Number GT-AV6-A-1 Control Output 0-10V Average RMS Input 0-300VAC Over Range x 1.5 Operating Temperature 0 - 60°C Load Voltage 100-240VAC/DC Span Adjustment Range +/-10% Zero Adjustment Range +/-5% Termination Style Screw Mounting Style DIN Rail Mount Case Material PC - UL 94 V0 Weight 170g Factory Pack Qty 1 Datasheet Product Datasheet
$239.00
$282.02 inclGST