Search results for "텔레@fundwash`!환치기비트코인전송대행"
-
KD6 40100M2, Datalogger with Internal Web page, Universal 85-253VAC, 90-300VDC, 4 x Programmable Analogue Inputs, Modbus TCP/RTU,HTTP/NTP/FTP/RS485/USB Comms, csv File Datalogging
Free Aus Post Shipping for $300 SpendLumel KD6 40100M2, Datalogger with Internal Web page, Universal 85-253VAC, 90-300VDC, 4 x Programmable Analogue Inputs, Modbus TCP/RTU,HTTP/NTP/FTP/RS485/USB Comms, csv File Datalogging Independent logging System Internal Web page 8GB Flash Memory USB/RS485/Ethernet Comms as standard Modbus TCP/RTU,HTTP/NTP/FTP Protocols Universal 85-253VAC, 90-300VDC Supply Optional 6 x Relay outputs Optional Binary Inputs and Outputs Optional Additional 4 Analogue Inputs Specification Lumel Part Number KD6 40100M2 Functions Communication Data logger and Internal Web page Supply Voltage 90-300VDC or 85-253VAC Protocols TCP/RTU/HTTP/NTP/FTP Communication Ports RS485/USB,Ethernet RS485/RS232 Baud Rate 1200,2400,4800,9600,19200,38400,57600,115200 bit/s USB Baud Rate 115200 bit/s Ethernet Baud Rate 10,100 Mbit/s Real Time Clock 1min/month (30ppm) Isolation 3.5kV Weight 600g Factory Pack Qty 1 EU Directives EN61000, EN61010 Safety Protection Class II Enclosure Material PC/ABS non combustable-self-extinguishability, complying with UL 94 V-0 Enclosure Protection IP20 Operating Temperature -20 →+70 °C Datasheet Product Datasheet User Manual
-
E500M-3012, 3 Analogue Output Module for Secure, Elite 500 Series
Elite E500M-3012, 3 Analogue Output Module for Secure, Elite 500 Series The meter is intended for measuring, analysing and monitoring single-phase or three-phase electrical power network. The meter records TRMS value according to the principle of fast sampling of voltage and current signals. A built-in microprocessor calculates measurands (voltage, current, frequency, energy, power, power factor, phase angles, etc.) from the measured signals. Elite 500 Features : Measurement of instantaneous values and accumulated energy. Includes Harmonics to the 31st Accuracy class to 0.2S Dual Internal Loggers Measurement of 20 minimal and maximal values in different time periods RS 232/RS 485 communication up to 38400 bit/s or Ethernet communication MODBUS communication protocol Up to 4 inputs or outputs (pulse outputs, alarm outputs, tariff inputs Universal or AC power supply Graphic Colour TFT 320 x 240 pixels (53x70mm) Automatic range of nominal current up to 6 A and nominal voltage up to 500 V Multilingual support User-friendly Free ECon Configuration software
$149.00
$175.82 inclGST -
E500M-1022, Modbus TCP/IP Gateway Module for Secure, Elite 500 Series
Elite E500M-1022, Modbus TCP/IP Gateway Module for Secure, Elite 500 Series The meter is intended for measuring, analysing and monitoring single-phase or three-phase electrical power network. The meter records TRMS value according to the principle of fast sampling of voltage and current signals. A built-in microprocessor calculates measurands (voltage, current, frequency, energy, power, power factor, phase angles, etc.) from the measured signals. Elite 500 Features : Measurement of instantaneous values and accumulated energy. Includes Harmonics to the 31st Accuracy class to 0.2S Dual Internal Loggers Measurement of 20 minimal and maximal values in different time periods RS 232/RS 485 communication up to 38400 bit/s or Ethernet communication MODBUS communication protocol Up to 4 inputs or outputs (pulse outputs, alarm outputs, tariff inputs Universal or AC power supply Graphic Colour TFT 320 x 240 pixels (53x70mm) Automatic range of nominal current up to 6 A and nominal voltage up to 500 V Multilingual support User-friendly Free ECon Configuration software
$335.00
$395.30 inclGST -
E500M-2012, Configurable Pulse Input Output Module for Secure, Elite 500 Series
Elite E500M-2012, Configurable Pulse Input Output Module for Secure, Elite 500 Series The meter is intended for measuring, analysing and monitoring single-phase or three-phase electrical power network. The meter records TRMS value according to the principle of fast sampling of voltage and current signals. A built-in microprocessor calculates measurands (voltage, current, frequency, energy, power, power factor, phase angles, etc.) from the measured signals. Elite 500 Features : Measurement of instantaneous values and accumulated energy. Includes Harmonics to the 31st Accuracy class to 0.2S Dual Internal Loggers Measurement of 20 minimal and maximal values in different time periods RS 232/RS 485 communication up to 38400 bit/s or Ethernet communication MODBUS communication protocol Up to 4 inputs or outputs (pulse outputs, alarm outputs, tariff inputs Universal or AC power supply Graphic Colour TFT 320 x 240 pixels (53x70mm) Automatic range of nominal current up to 6 A and nominal voltage up to 500 V Multilingual support User-friendly Free ECon Configuration software
$149.00
$175.82 inclGST -
FBT B PVM 150 RM, 150VDC Surge Protection Device for Photovoltaic Systems, Type 2 (Class II) 40kA WITH REMOTE C/O CONTACTS
FBT B PVM 150 RM, 150VDC Surge Protection Device for Photovoltaic Systems, Type 2 (Class II) 40kA WITH REMOTE C/O CONTACTS Specifications Trent part number FBT B PVM 150 RM Nominal Voltage 150VDC No of Poles 3 Category IEC / EN / VDE Type 2 (Class II) Location of use String Box, Inverter Protection modes (+)-PE,(-)-PE,(+)-(-) PE Additional Remote Contacts YES NO/NC/COM Protective element MOV No Fault/Fault Indication Green Flag / Not Green Flag Surge discharge rating Per pole 40kA (8/20uS)9KA) Max, 20kA (8/20uS)9KA) Nominal Internal protection and safety Thermal disconnector in each MOV Weight 420g Standards IEC614643-11:GB/T 18802.11: YD/T 1235.1, CE Datasheet Product Datasheet GDT/MOV/TVS Tester SPD Tester
$129.00
$152.22 inclGST -
FBT Y PVM 1500 RM, 1500VDC Surge Protection Device for Photovoltaic Systems, Type 2 (Class II) 40kA WITH REMOTE C/O CONTACTS
FBT Y PVM 1500 RM, 1500VDC Surge Protection Device for Photovoltaic Systems, Type 2 (Class II) 40kA WITH REMOTE C/O CONTACTS Specifications Trent part number FBT Y PVM 1500 RM Nominal Voltage 1500VDC No of Poles 3 Category IEC / EN / VDE Type 2 (Class II) Location of use String Box, Inverter Protection modes (+)-PE,(-)-PE,(+)-(-) PE Additional Remote Contacts YES NO/NC/COM Protective element MOV No Fault/Fault Indication Green Flag / Not Green Flag Surge discharge rating Per pole 40kA (8/20uS)9KA) Max, 20kA (8/20uS)9KA) Nominal Internal protection and safety Thermal disconnector in each MOV Weight 420g Standards IEC50539-11 (TUV Approved) Datasheet Product Datasheet GDT/MOV/TVS Tester SPD Tester
$149.00
$175.82 inclGST -
FBT B PVM 1000 RM, 1000VDC Surge Protection Device for Photovoltaic Systems, Type 1 (CLass I) + Type 2 (CLass II) 40kA WITH REMOTE C/O CONTACTS
FBT B PVM 1000 RM, 1000VDC Surge Protection Device for Photovoltaic Systems, Type 1 (CLass I) + Type 2 (CLass II) 40kA WITH REMOTE C/O CONTACTS Specifications Trent part number FBT B PVM 1000 RM Nominal Voltage 1000VDC No of Poles 3 Category IEC / EN / VDE Type 1 (CLass I) + Type 2 (CLass II) Location of use String Box, Inverter Protection modes (+)-PE,(-)-PE,(+)-(-) PE Additional Remote Contacts YES NO/NC/COM Protective element MOV No Fault/Fault Indication Green Flag / Not Green Flag Surge discharge rating Per pole 40kA (8/20uS)9KA) Max, 20kA (8/20uS)9KA) Nominal Internal protection and safety Thermal disconnector in each MOV Weight 420g Standards IEC614643-11:GB/T 18802.11: YD/T 1235.1, CE Datasheet Product Datasheet GDT/MOV/TVS Tester SPD Tester
$129.00
$152.22 inclGST -
BLR-CM12R-MB, Power Factor Regulator, 12 Step, 1 Phase Measurement, 3 Phase Control, 50-530V 50/60HZ, RS485 Modbus RTU Comms (OBSOLETE 2025)
BLR-CM12R-MB, Power Factor Regulator, 12 Step, 1 Phase Measurement, 3 Phase Control, 50-530V 50/60HZ, RS485 Modbus RTU Comms (OBSOLETE 2025) Single CT Sensing 32nd Harmonic Measurement Isolated Switching of Power Factor Correction Contactors Cos ϕ Setting 0.9 to 0.9 CAP Auto CT Secondary Selection Backlit LCD Display Various Program Combinations IP41 Up to 12 steps Measurement System - Automatic/Manual 50-530VAC Measurement 100-132V / 207-253VAC (L-N) Aux Supply Configurable Alarms Dual Password Protection Programmable Fan Control Programmable 1A/5A CT Ratio Specification Beluk Part Number BLR-CM12R-MB Function Reactive Power Correction Nominal Voltage (Un) 50-530VAC Line to Line Supply Voltage 100-132V / 207-253VAC (L-N), 45-65Hz, max fuse 6A Relay Rating 250VAC/5Amp Static Output Rating (T Models) 8-48VDC / 100mA Internal 2MB Logger Optional 3 x CT Measurement Optional Switch Delay Time 1s - 1200s User Adjustable Alarm 1 x Relay as above Temperature/Fan/THD Alarm 1 x Relay as above Re-connection Delay Time 50 - 1200s User Adjustable Desired Power Factor 0.90 IND - 0.90 CAP Number of Output Relays 12 Smallest Capacitor Current 10mA CT Input Range 15mA - 6 Amp LCD Display Accuracy Voltage +/-0.5%, Frequency +/-0.1%, Power +/-1% Energy Class 1 Phase Angle Error +/- 1% at I > 3% of range Comms RS485 Modbus RTU Termination Style Screw Weight 700g Certification IEC 654-1 Factory Pack Qty 1 Material of housing PC/ABS Unflammable, according to UL 94 V-0 Enclosure protection IP50 for case, IP20 for terminals Safety According to EN 61 010-1, installation category III Pollution degree 2 Operating Temperature -20...60 °C Datasheet User Manual Modbus user Manual Application Notes Discharge Resistor Usage Power Factor Correction Blog Quick Start Guide(Blog)
$1,549.75
$1,828.71 inclGST -
FBT P BCM12.5 275 RM (4+0), Class I,II / Type 1,2 / B,C, AC Surge Protection Device (SPD) with Remote Contacts, 3 Pole 37.5kA,440VAC, DIN Rail Mount, L/N-PE, L-PEN, L-N, N-PE High Energy MOV Type
Free Aus Post Shipping for $300 SpendTrent FBT P BCM12.5 275 RM (4+0), Class I,II / Type 1,2 / B,C, AC Surge Protection Device (SPD) with Remote Contacts, 3 Pole 37.5kA,440VAC, DIN Rail Mount, L/N-PE, L-PEN, L-N, N-PE High Energy MOV Type Specifications Trent part number FBT P BCM12.5 275 RM (4+0) Nominal Voltage 440VAC No of Poles 4 Category IEC / EN / VDE Class I,II / Type 1,2 / B,C Location of use Main Distribution Boards Protection modes L/N-PE, L-PEN, L-N, N-PE High Energy MOV Additional Remote Contacts YES Protective element MOV Surge discharge rating Imax up to 37.5 kA(10/350us) / 100kA(8/20us) or 12.5kA(10/350us) / 60kA(8/20us) per pole Internal protection and safety Thermal disconnector in each MOV Standards IEC/EN 61643-11 Datasheet Product Datasheet
-
TCC-82, MOXA Port Powered 4kV RS-232 Serial Isolator
Free Aus Post Shipping for $300 SpendMOXA Port Powered 4kV RS-232 Serial Isolator Features RS232 DB9 Male Port Isolator Comes with Plug Pack power supply Port powered or Aux Supply Powered Used for common mode noise rejections in high dV/dT environments such as UPS, Trackside Rail Equipment 4kV RMS Isolation (1 Min) Automatic baud rate detection Datasheet Product Datasheet
-
FBT Y PVM 1000 RM, 1000VDC Surge Protection Device for Photovoltaic Systems, Type 2 (Class II) 40kA WITH REMOTE C/O CONTACTS
FBT Y PVM 1000 RM, 1000VDC Surge Protection Device for Photovoltaic Systems, Type 2 (Class II) 40kA WITH REMOTE C/O CONTACTS Specifications Trent part number FBT Y PVM 1000 RM Nominal Voltage 1000VDC No of Poles 3 Category IEC / EN / VDE Type 2 (Class II) Location of use String Box, Inverter Protection modes (+)-PE,(-)-PE,(+)-(-) PE Additional Remote Contacts YES NO/NC/COM Protective element MOV No Fault/Fault Indication Green Flag / Not Green Flag Surge discharge rating Per pole 40kA (8/20uS)9KA) Max, 20kA (8/20uS)9KA) Nominal Internal protection and safety Thermal disconnector in each MOV Weight 420g Standards IEC614643-11:GB/T 18802.11: YD/T 1235.1, CE Datasheet Product Datasheet GDT/MOV/TVS Tester SPD Tester
$129.00
$152.22 inclGST -
88970800, Crouzet Millenium 3 Expansion XA03, 3 x PT100 Inputs
Free Aus Post Shipping for $300 SpendCrouzet 88970800 Millenium 3 Expansion XA03, 3 x PT100 Inputs Datasheet Product Datasheet Software Crouzet Touch Soft V6.00.02.173 Software M3-soft-AC9-V3.1.2.0_ML Remote Control Software CVD_PC_V2_3_01_02 Crouzet Soft EVO EM4 1.12.01.14