Fastron FPC1-25-20C-24VAC/DC, Two Pole 2 x SPST NO Modular Contactor 230VAC 25 Amp, 24VAC/DC 50/60Hz Coil Voltage, Hum Free
Features
25 Amp (rms) @ 230VAC
DIN Rail Mount
Slim package
CE Compliant to IEC 60664
IP20
Specification
Fastron Part Number
FPC1-25-20C-24VAC/DC
Switching Type
2 x SPST NO
Approvals
CE
Coil Voltage
230VAC 50/60Hz
Load Rating
25 Amp
Special Feature
Hum Free
Mounting Style
DIN Rail Mount
Load Voltage Range
24VAC/DC 50/60Hz
Isolation
4kV
Termination Style
Screw
Unit Weight
295g
Factory Pack Qty
20
Datasheet
Datasheet
Auxiliary Contacts Selection Guide
Fastron TC5-L-1U-2-G-2 PID Controller, 100-240VAC with 2 3 Amp Relay Alarms, K,E,J,N,T,S,R,B Thermocouple, Linear Current/Voltage and PT100/Cu20 RTD Input, 96x96mm,0-10V Output
4-digit displays (0.5s response)
Drip-proof / Dust-proof IP66 (front panel only)
Input signals can be converted to insulated -0-10V, Relay, 12VDC (SSR) and 4 to 20 mA DC outputs available
Each unit needs just 75 mm depth panel space
Specification
Fastron Part Number
TC5-L-1U-2-G-2
Control Output
0-10V
Input
Multirange Type K, J, E,S,T,R, Pt100, Cu50/Linear Current 4(0)-20mA/Linear Voltage 0-10(5)V
Option 1
2 3 Amp Relay Alarms standard (Excludes 96x96mm with SSR/Relay output)
Mounting Style
96x96mm Panel Mount
Supply Voltage
100 - 240VAC +/-10%
Termination Style
Screw
Sampling Time
100ms
Weight
150-270g
Factory Pack Qty
10
Datasheet
TC5 Datasheet and User Manual
Secure Meters DPM96R360-2, 96mm x 96mm LCD Reactive Power Meter, 3 Phase 100-500VAC, 0-6 Amp Inputs, 0.5% Accuracy, 40 to 300VAC/DC Supply, IP54 (Optional IP65)
Features
LCD Dual Display
250mS Response Time
PC 94 UL V0
Each unit needs just 96 x 96mm Panel Space
52mm Depth
CE Approved
ROHS and REACH
Specification
Secure Part Number
DPM96R360-2
Frequency Range
45-65 Hz
Accuracy
0.5%
Input
5/6 Amp 3 Phase CT inputs, 100-500VAC
Over Range
x 1.5
Operating Temperature
0 - 60°C
Supply Voltage
40-300VAC/DC
Termination Style
Screw
Mounting Style
96 x 96mm Panel Mount
Case Material
PC - UL 94 V0
Standards
IEC / EN 61010-1; IEC / EN 61010-2-030, IEC / EN 62053-21
Protection Degree
IP54 (IP65 Optional)
Weight
450g
Factory Pack Qty
1
Datasheet
Product Datasheet
Manual
DPM Series User Manual
Application Notes
Panel Meters Blog Articles
Fastron FC5-W-1U-1-G-2-C PID Controller, 100-240VAC with 1 Alarm, RS485, K,E,J,N,T,S,R,B Thermocouple, Linear Current/Voltage and PT100/Cu20 RTD Input, 96x48mm,0-10V Output
4-digit displays (0.5s response)
Drip-proof / Dust-proof IP66 (front panel only)
Input signals can be converted to insulated -0-10V, Relay, 12VDC (SSR) and 4 to 20 mA DC outputs available
Each unit needs just 75 mm depth panel space
Specification
Fastron Part Number
FC5-W-1U-1-G-2-C
Control Output
0-10V
Input
Multirange Type E,J,N,T,S,R,B, Pt100, Cu50/Linear Current 4(0)-20mA/Linear Voltage 0-10(5)V
Option 1
1 Alarm, RS485 standard (Excludes 96x48mm with SSR/Relay output)
Mounting Style
96x48mm Panel Mount
Supply Voltage
100 - 240VAC +/-10%
Termination Style
Screw
Sampling Time
100ms
Weight
150-270g
Factory Pack Qty
10
Datasheet
Datasheet
User Manual
Modbus Protocol
FC5 Communication Protocol
Crouzet 88975111, Millenium EVO Ethernet, Smart Relay with Display, 24 I/O, 24VDC, 8 Configurable Analogue/Digital Inputs, 4 x High Speed 15kHz Inputs, 4 x Std Digital Inputs, 2 x 6 Amp Relay, 6 x 8 Amp Relay
Up to 44 I/Os - 16 DI (4 HighSpeed / 8 AI) - 8 DO
Wireless programming & Control with bluetooth Interface and Crouzet Virtual Display
Modbus RTU Network (Slave)
Local datalog management
Up to 1000 programing blocks with intuitive Crouzet Soft to go from simple to complex applications
HMI Screens Available
Specification
Crouzet Part Number
88975111 (Millenium EVO)
Analogue Inputs
0 - 10VDC, 0-V Power Supply or Voltmeter
Digital Inputs
24VDC @ 2.1mA (8 Standard and 4 High Speed)
Digital Outputs
Relay, 24VDC, 250VAC @ 100mA minimum (2 x 6 Amp, 6 x 8 Amp)
PWM SSR Output
None
Expandable
Yes
Comms
Ethernet. (RS485, Bluetooth). Standard and Wifi versions available
LCD Display
Yes
Mounting Style
DIN Rail Mount (124.6mm)
Supply Voltage Range
24VAC (21.6 - 28.8VAC)
Termination Style
Screw
Weight
350g
Environmental
Reach, RoHS, Halogen free 1272/2008/CE
Certification
CE, cULus Listed
Factory Pack Qty
1
Over Voltage Category
3 in accordance with IEC/EN 60664-1
Pollution Degree
2 in accordance with IEC/EN 61131-2
Protection rating
IP40 (Front), IP20 (Rear)
Mechanical Resistance
Immunity to vibrations IEC/EN 60068-2-6, test Fc
Immunity to shock IEC/EN 60068-2-27, test Ea
Resistance to HF Interference
Immunity to radiated electrostatic fields IEC/EN 61000-4-3 Immunity to fast transients (burst immunity) IEC/EN 61000-4-4, level 3 Immunity to shock waves IEC/EN 61000-4-5 Radio frequency in common mode IEC/EN 61000-4-6, level 3 Voltage dips and breaks (AC) IEC/EN 61000-4-11 Immunity to damped oscillatory waves IEC/EN 61000-4-12
Conducted and radiated emissions
Class B (*) in accordance with EN 55022, EN 55011 (CISPR22, CISPR11) group 1 (*) Except configuration (88 970 1.1 or 88 970 1.2) + (88 970 250 or 88 970 270) + 88 970 241 class A (class B in a metal enclosure)
Operating Temperature
-20 →+70 °C except CB and XB versions in VDC : -30 →+70 °C (+40 °C in a non-ventilated enclosure) in accordance with IEC/EN 60068-2-1 and IEC/EN 60068-22
Datasheet
Product Datasheet
Launching Note
Software
Crouzet Touch Soft V6.00.02.173
Software M3-soft-AC9-V3.1.2.0_ML
Remote Control Software CVD_PC_V2_3_01_02
Crouzet Soft EVO EM4 1.12.01.14
Secure Meters DPM96M360-2, 96mm x 96mm LCD AC Voltmeter, AC Ammeter, and Frequency Meter, 3 Phase 0-500VAC, 1/5A, 45-65 Hz Input, 0.5% Accuracy, 40 to 300VAC/DC Supply, IP54 (Optional IP65)
Features
LCD Dual Display
250mS Response Time
PC 94 UL V0
Each unit needs just 96 x 96mm Panel Space
52mm Depth
CE Approved
ROHS and REACH
Specification
Secure Part Number
DPM96M360-2
Frequency Range
45-65 Hz
Accuracy
0.5%
Input
100-500VAC, 0-1.2A/0-6A, 45-65Hz
Over Range
x 1.5
Operating Temperature
0 - 60°C
Supply Voltage
40-300VAC/DC
Termination Style
Screw
Mounting Style
96 x 96mm Panel Mount
Case Material
PC - UL 94 V0
Standards
IP54 (IP65 Optional)
Protection Degree
IEC / EN 61010-1; IEC / EN 61010-2-0301
Weight
450g
Factory Pack Qty
1
Datasheet
Product Datasheet
Manual
DPM Series User Manual
Application Notes
Panel Meters Blog Articles
Fastron TC5-H-W-2-T/R-2, 100-240VAC PID Controller with 2 3 Amp Relay Alarms, K,E,J Thermocouple, Pt100 or Cu20, Optional Linear Current/Voltage, 48x96mm,Relay + 12VDC Output
4-digit displays (0.5s response)
Drip-proof / Dust-proof IP66 (front panel only)
Input signals can be converted to insulated -0-10V, Relay, 12VDC (SSR) and 4 to 20 mA DC outputs available
Each unit needs just 75 mm depth panel space
Now available will full Multirange input (K,E,J,N,T,S,R,B Thermocouple, Linear Current/Voltage and PT100/Cu20 RTD Input, 96x48mm,4-20mA Output)
Specification
Fastron Part Number
TC5-H-W-2-T/R-2
Control Output
Relay 3A(Resistive), 1A(Inductive load cos Ѳ=0.4)/12VDC @ 20mA
Input
Multirange Type,K,E,J, Pt100, Cu50/(Optional)Linear Current 4(0)-20mA/(Optional)Linear Voltage 0-10(5)V
Option 1
2 3 Amp Relay Alarms standard (Excludes 48x96mm with SSR/Relay output)
Mounting Style
48x96mm Panel Mount
Supply Voltage
100 - 240VAC +/-10%
Termination Style
Screw
Sampling Time
100ms
Weight
150-270g
Factory Pack Qty
10
Approvals
CE
Datasheet
TC5 Datasheet and User Manual
Fastron FC5-M-W-1-G-4 PID Controller, 24VDC with 1 Alarm, K,E,J,N,T,S,R,B Thermocouple, Linear Current/Voltage and PT100/Cu20 RTD Input, 72x72mm, Relay + SSR Output
4-digit displays (0.5s response)
Drip-proof / Dust-proof IP66 (front panel only)
Input signals can be converted to insulated -0-10V, Relay, 12VDC (SSR) and 4 to 20 mA DC outputs available
Each unit needs just 75 mm depth panel space
Specification
Fastron Part Number
FC5-M-W-2-G-4
Control Output
Relay 3A(Resistive), 1A(Inductive load cos Ѳ=0.4)/ SSR 12VDC 40mA
Input
Multirange K,E,J,N,T,S,R,B Thermocouple, PT100/Cu20 RTD Input/Linear Current 4(0)-20mA/Linear Voltage 0-10(5)V
Option 1
2 Alarm, standard
Comms
Optional (Modbus RTU 38400 Max Baud Rate)
Mounting Style
72x72mm Panel Mount
Supply Voltage
100 - 240VAC +/-10%
Termination Style
Screw
Sampling Time
100ms
Weight
150-270g
Factory Pack Qty
10
Datasheet & User Manual
Datasheet
User Manual
FC5 Communication Protocol
Eastron Smart Smart X96-5J-2-1-C, Panel Mount Multifuction Meter, Class 0.5s, 65-480VAC, 1A/5A CT input, 30 Parameter, 2 x Digital Pulse/Alarm Outputs, Ethernet Gateway, 65-480VAC Aux
Ethernet Gateway Function
Metering and Numerical Display
Adjustable tariff clock (Optional 4 Tarriffs), display of electric energy consumption in optional currency
Ethernet communication as standard
True RMS values of currents and voltages
Measurements of active, reactive, apparent power and power factor
The meter is intended for measuring, analysing and monitoring single-phase or three-phase electrical power network. The meter records TRMS value according to the principle of fast sampling of voltage and current signals. A built-in microprocessor calculates measurands (voltage, current, frequency, energy, power, power factor, phase angles, etc.) from the measured signals.
Features :
Measurement of instantaneous values of more than 30 quantities (U, I, P, THD, IHD, S, PF, PA, f, f, MD, etc.).
Accuracy class 0.5s
Optional 2 or 4 tariff inputs,
Digital Output and Input
Ethernet communication protocol
Up to 4 inputs or outputs (pulse outputs, alarm outputs, tariff inputs)
Universal or AC power supply
Graphic LCD with Dual Metering and PF Displays
Specification
Eastron Part Number
Smart X96-5I-2-1-C
Functions
Power Quality Meter, Energy Meter
Supply Voltage
65-480VAC < 7VA/3.5W
Nominal Measurement Range
65-480V L-N, 1/5 Amp
Maximum Measurement Range
280V L-N, 1/5 Amp
Pulse Outputs
2 x Digital Outputs (shared with Alarm function)
Alarm
2 x Digital Outputs (shared with Pulse function)
Tariff Input
1 (Optional 4 x )
Accuracy
Class 0.5s (I,U,F,PF,θ,THD) Class 0.5(Active), Class 1 (Reactive)
Battery Backup
N/A
Real Time Clock
1min/month (30ppm)
Isolation
2.5kV (1 Min)
Ethernet
2400-38400 b/s (Gateway Function)
Weight
500g
Certification
MID, UL
Factory Pack Qty
1
Enclosure Material
PC/ABS non combustable-self-extinguishability, complying with UL 94 V-0
Operating Temperature
-25 →+55 °C
Datasheet
Product Datasheet
User Manual
Modbus Registers
Crouzet 88981106 Crouzet em4 Local PLC Starter Kit, 16 x Inputs, 2 (PWM), 8 (Relay) Outputs, 24 V ac/dc
Up to 104 I/Os - 16 DI (4 High Speed / 8 AI)
10 x DO (2 x Solid State 0.5Amp PWM, 2 Relays 6 Amp, and 6 Relays 8 Amp)
Optional Wireless Programming & Control with native 3G and Crouzet Virtual Display
Optional Modbus RTU Network (Master/Slave)
Local datalog management
Up to 1000 programing blocks with intuitive Crouzet Soft to go from simple to complex applications
HMI Screens Available
Specification
Crouzet Part Number
88981106 (em4 Local)
Analogue Inputs
12 x 0 - 10VDC, (4 High Speed)
Digital Inputs
24VAC/DC @ 2.1mA (8 Standard and 4 High Speed)
Digital Outputs
Relay, 12 or 24VAC/DC, 250VAC @ 100mA minimum (2 x 6 Amp, 6 x 8 Amp)
PWM SSR Output
2
Expandable
Yes
Comms
None (RS485, Bluetooth,3G,Standard, Ethernet) and Wifi versions available
LCD Display
Yes
Mounting Style
DIN Rail Mount (124.6mm)
Supply Voltage Range
24VAC/DC (21.6 - 28.8VAC)
Termination Style
Screw
Weight
350g
Environmental
Reach, RoHS, Halogen free 1272/2008/CE
Certification
CE, cULus Listed
Factory Pack Qty
1
Over Voltage Category
3 in accordance with IEC/EN 60664-1
Pollution Degree
2 in accordance with IEC/EN 61131-2
Protection rating
IP40 (Front), IP20 (Rear)
Mechanical Resistance
Immunity to vibrations IEC/EN 60068-2-6, test Fc
Immunity to shock IEC/EN 60068-2-27, test Ea
Resistance to HF Interference
Immunity to radiated electrostatic fields IEC/EN 61000-4-3 Immunity to fast transients (burst immunity) IEC/EN 61000-4-4, level 3 Immunity to shock waves IEC/EN 61000-4-5 Radio frequency in common mode IEC/EN 61000-4-6, level 3 Voltage dips and breaks (AC) IEC/EN 61000-4-11 Immunity to damped oscillatory waves IEC/EN 61000-4-12
Conducted and radiated emissions
Class B (*) in accordance with EN 55022, EN 55011 (CISPR22, CISPR11) group 1 (*) Except configuration (88 970 1.1 or 88 970 1.2) + (88 970 250 or 88 970 270) + 88 970 241 class A (class B in a metal enclosure)
Operating Temperature
-20 →+70 °C except CB and XB versions in VDC : -30 →+70 °C (+40 °C in a non-ventilated enclosure) in accordance with IEC/EN 60068-2-1 and IEC/EN 60068-22
Datasheet
Product Datasheet
Software
Crouzet Touch Soft V6.00.02.173
Software M3-soft-AC9-V3.1.2.0_ML
Remote Control Software CVD_PC_V2_3_01_02
Crouzet Soft EVO EM4 1.12.01.14
Fastron TC5-M-1U-2-T/R-2 PID Controller, 100-240VAC with 2 3 Amp Relay Alarms, K,E,J Thermocouple, Pt100 or Cu20, Optional Linear Current/Voltage, 72x72mm,0-10V Output
4-digit displays (0.5s response)
Drip-proof / Dust-proof IP66 (front panel only)
Input signals can be converted to insulated -0-10V, Relay, 12VDC (SSR) and 4 to 20 mA DC outputs available
Each unit needs just 75 mm depth panel space
Now available will full Multirange input (K,E,J,N,T,S,R,B Thermocouple, Linear Current/Voltage and PT100/Cu20 RTD Input, 96x48mm,4-20mA Output)
Specification
Fastron Part Number
TC5-M-1U-2-T/R-2
Control Output
0-10V
Input
Multirange Type,K,E,J,Pt100, Cu50/(Optional)Linear Current 4(0)-20mA/(Optional)Linear Voltage 0-10(5)V
Option 1
2 3 Amp Relay Alarms standard (Excludes 72x72mm with SSR/Relay output)
Mounting Style
72x72mm Panel Mount
Supply Voltage
100 - 240VAC +/-10%
Termination Style
Screw
Sampling Time
100ms
Weight
150-270g
Factory Pack Qty
10
Datasheet