Rish Con-I(5A)-F-H-O1A1-O200-D-Z-Z, AC Current Transducer, Input Programmable True RMS 50Hz, 1A-5A Full Scale, 4-20mA, 60-300VAC/DC Supply, with display
Rishabh Rish Con-I(5A)-F-H-O1A1-O200-D-Z-Z, AC Current Transducer, Input Programmable True RMS 50Hz, 1A-5A Full Scale, 4-20mA, 60-300VAC/DC Supply, with display Digital output setting 0-20mA/4-20mA/0-10V Dual output version available 300mS response time PC 94 UL V0 Input signals can be converted to insulated 4 to 20 mA DC output (for direct current output type) Each unit needs just 43.75 x 100.9 mm depth DIN Rail cabinet space Specification Rishabh Part Number Rish Con-I(5A)-F-H-O1A1-O200-D-Z-Z Measurement Output 4-20mA/0-20mA/0-10V User Selectable Input 1 - 5 Amp 50/60Hz Overlaod (Continuous) 120% Overload (1 second) 150% Operating Temperature -40 - 70°C Supply Voltage 60 - 300VAC Accuracy 0.2% Response Time 300mS Termination Style Screw Mounting Style DIN Rail Mount Safety IP40/IP20 EN60529 Protection Class II EN61010 Weight 400g Factory Pack Qty 1 Datasheet Product Datasheet Technical Support Rish Con P setup procedure blog
$259.00
$305.62 inclGST -
DFKF-18-0006, DFKF Compensated Choke 4A 0.7mH
Schurter DFKF-18-0006 (DFKF2-18-4.0-.7), DFKF Compensated Choke Features Linear choke THT-terminals Inductor horizontally positioned in housing Applications Common Mode Attenuation Smoothing RFI suppression choke RFI suppression choke Chopper amplifiers DC drives and stepper motor controls Switching power supplies Specification Schurter Part Number DFKF-18-0006 Rated Voltage 440V Rated Current 4A Inductance 0.7mH Operating Temperature -25°C to 125°C Resistance 16mΩ Resonant Frequency 2.5MHz Mounting PCB Mount Material Thermoplastic, black, UL 94V-0 Termination Style THT Terminals Weight 5g Factory Pack Qty 1 Climatic Category 40/125/21 acc. to IEC 60068-1 Isolation 1.8kV VDE/UL/CSA/ROHS Yes Datasheet Product Datasheet Application Notes
$2.45
$2.89 inclGST -
DLH-22-0001, Schurter Choke 0.45Amp, 5mH, 50mOhm, F(res) = 9Mhz
Schurter DLH-22-0001 Choke Features Linear choke THT-terminals Inductor vertically positioned in housing Applications Smoothing RFI suppression choke RFI suppression choke Chopper amplifiers DC drives and stepper motor controls Switching power supplies Specification Schurter Part Number DLH-22-0001 Rated Voltage 600V Rated Current 0.45A Inductance 5mH Operating Temperature -25°C to 125°C Resistance 2600mΩ Resonant Frequency 0.2 MHz Mounting PCB Mount Material Thermoplastic, black, UL 94V-0 Termination Style THT Terminals Weight 14g Factory Pack Qty 1 Climatic Category 40/125/21 acc. to IEC 60068-1 Isolation 2kV VDE/UL/CSA/ROHS Yes Datasheet Product Datasheet Application Notes
$5.08
$5.99 inclGST -
5500.2001, EMC (RFI) Line Filter, PCB Mount, FPP2.25.1/A, 250VAC, 1 Amp
Timonta 5500-2001 (FPP2-25-1/A), 1 Stage EMC (RFI) Line Filter for Single Phase systems Features Line filter for PCB Mounting 1-stage - standard attenuation Characteristics Designed for standard applications Protection against interference voltage from the mains Possible interferences generated in the equipment are strongly attenuated Universal line filter for standard applications Suitable for use in equipment according to IEC/UL 60950 Specification Schurter Part Number 5500-2001 Rated Voltage 250V Rated Current 1A Filter Stages 1 Stage Operating Temperature -25°C to 85°C Filter Type Standard Attenuation Leakage Current 0.25mA Mounting PCB Mount Material Thermoplastic, black, UL 94V-0 Termination Style Solder Pin Weight 27g Factory Pack Qty 1 Protection Class From front side IP 40 acc. to IEC 60529 Isolation 1.7kV VDE/UL/CSA/ROHS Yes Datasheet Product Datasheet
$5.90
$6.96 inclGST -
5500.2002, EMC (RFI) Line Filter, PCB Mount, FPP2.25.2/A, 250VAC, 2 Amp
Schurter 5500-2002 (FPP2-25-2/A), 1 Stage EMC (RFI) Line Filter for Single Phase systems Features Line filter for PCB Mounting 1-stage - standard attenuation Characteristics Designed for standard applications Protection against interference voltage from the mains Possible interferences generated in the equipment are strongly attenuated Universal line filter for standard applications Suitable for use in equipment according to IEC/UL 60950 Specification Schurter Part Number 5500-2002 Rated Voltage 250V Rated Current 2A Filter Stages 1 Stage Operating Temperature -25°C to 85°C Filter Type Standard Attenuation Leakage Current 0.25mA Mounting PCB Mount Material Thermoplastic, black, UL 94V-0 Termination Style Solder Pin Weight 27g Factory Pack Qty 1 Protection Class From front side IP 40 acc. to IEC 60529 Isolation 1.7kV VDE/UL/CSA/ROHS Yes Datasheet Product Datasheet
$5.90
$6.96 inclGST -
5500.2039, 1 Stage EMC (RFI) Line Filter, FMW2.41.1/I, 250VAC, 1Amp
Schurter 5500-2039, 1 Stage EMC (RFI) Line Filter for Single Phase systems Features Line filter in standard and medical version 1-stage - standard attenuation Characteristics Designed for standard applications Protection against interference voltage from the mains Possible interferences generated in the equipment are strongly attenuated Universal line filter for standard applications Suitable for use in equipment according to IEC/UL 60950 Other Versions on Request Version with wire connection Version with varistor for overvoltage protection Specification Schurter Part Number 5500-2042 Rated Voltage 250V Rated Current 1A Filter Stages 1 Stage Operating Temperature -25°C to 85°C Filter Type Standard Attenuation Leakage Current 0.25mA Mounting Panel Mount - Case 41 Material Metal Termination Style Screw Weight 55g Factory Pack Qty 1 Protection Class From front side IP 40 acc. to IEC 60529 Isolation 1.7kV VDE/UL/CSA/ROHS Yes Datasheet Product Datasheet
$19.50
$23.01 inclGST -
IL-11-0001 (IL1-11-1), Pulse Transformer, 1:1 500V/uS, Tr = 1uS, RL = 100 Ohm, Iz = 100mA, Ub(V) = 500V, Pm = 0.5W
Schurter IL-11-0001 (IL1-11-1), Pulse Transformer Features High insulation rating (>2.2 kVAC) between the primary and the secondary windings Small coupling capacitances between primary and secondary windings limit transient feedback from the power supply side to the control electronics Cost optimized design The defined partial discharge voltage guarantees an effectively unlimited serviceable live Applications Galvanic separation of drive and power-circuit Mainly used in ignition circuits with Thyristors, Triacs, power transistors and IGBT's DC/DC converters Line coupling transformers in high speed data transmission Specification Schurter Part Number IL-11-0001 (IL1-11-1) Rated Voltage 500V Rated Current (Iz) 100mA Inductance 8mH Transformer Ratio 1:1 Rated Power (Pm) 0.5W Resistance (RL) 100mΩ Rise Time (Tr) 1uS Operating Temperature -25°C to 125°C Mounting PCB Mount Material Thermoplastic, black, UL 94V-0 Termination Style THT Terminals Weight 14g Factory Pack Qty 1 Climatic Category 40/125/21 acc. to IEC 60068-1 Isolation 3.5kV VDE/UL/CSA/ROHS Yes Datasheet Product Datasheet Application Notes
$9.85
$11.62 inclGST -
IL-20-0001 (IL5-20-2), Pulse Transformer IL-20-0001, 1:1:1, Iz = 250mA, Ub(V) = 380V
Schurter IL-20-0001 (IL5-20-2), Pulse Transformer Features High insulation rating (>2.2 kVAC) between the primary and the secondary windings Small coupling capacitances between primary and secondary windings limit transient feedback from the power supply side to the control electronics Cost optimized design The defined partial discharge voltage guarantees an effectively unlimited serviceable live Applications Galvanic separation of drive and power-circuit Mainly used in ignition circuits with Thyristors, Triacs, power transistors and IGBT's DC/DC converters Line coupling transformers in high speed data transmission Specification Schurter Part Number IL-20-0001 (IL5-20-2) Rated Voltage 380V Rated Current (Iz) 250mA Inductance 3mH Transformer Ratio 1:1:1 Rated Power (Pm) 1.1W Resistance (RL) 2 x 40Ω Rise Time (Tr) 1.5uS Operating Temperature -25°C to 125°C Mounting PCB Mount Material Thermoplastic, black, UL 94V-0 Termination Style THT Terminals Weight 14g Factory Pack Qty 1 Climatic Category 40/125/21 acc. to IEC 60068-1 Isolation 3.5kV VDE/UL/CSA/ROHS Yes Datasheet Product Datasheet Application Notes
$8.63
$10.18 inclGST -
ILR-11-0002 (ILR2-11-3), Pulse Transformer 2:1, Iz = 1000mA, Ub(V) = 500V
Schurter ILR-11-0002 (ILR2-11-3), Pulse Transformer Features High insulation rating (>2.2 kVAC) between the primary and the secondary windings Small coupling capacitances between primary and secondary windings limit transient feedback from the power supply side to the control electronics Cost optimized design The defined partial discharge voltage guarantees an effectively unlimited serviceable live Applications Galvanic separation of drive and power-circuit Mainly used in ignition circuits with Thyristors, Triacs, power transistors and IGBT's DC/DC converters Line coupling transformers in high speed data transmission Specification Schurter Part Number ILR-11-0002 (ILR2-11-3) Rated Voltage 500V Rated Current (Iz) 1000mA Inductance 2.5mH Transformer Ratio 2:1 Rated Power (Pm) 0.5W Resistance (RL) 10Ω Rise Time (Tr) 0.3uS Operating Temperature -25°C to 125°C Mounting PCB Mount Material Thermoplastic, black, UL 94V-0 Termination Style THT Terminals Weight 14g Factory Pack Qty 1 Climatic Category 40/125/21 acc. to IEC 60068-1 Isolation 3.2kV VDE/UL/CSA/ROHS Yes Datasheet Product Datasheet
$9.95
$11.74 inclGST -
IR5-33-3, Pulse Transformer 1:1:1, Iz = 1000mA, Ub(V) = 380V
Schurter IR5-33-3, Pulse Transformer Features High insulation rating (>2.2 kVAC) between the primary and the secondary windings Small coupling capacitances between primary and secondary windings limit transient feedback from the power supply side to the control electronics Cost optimized design The defined partial discharge voltage guarantees an effectively unlimited serviceable live Applications Galvanic separation of drive and power-circuit Mainly used in ignition circuits with Thyristors, Triacs, power transistors and IGBT's DC/DC converters Line coupling transformers in high speed data transmission Specification Schurter Part Number IR5-33-3 Rated Voltage 380V Rated Current (Iz) 1000mA Inductance 10mH Transformer Ratio 1:1:1 Rated Power (Pm) 2W Resistance (RL) 2 x 10Ω Rise Time (Tr) 0.3uS Operating Temperature -25°C to 125°C Mounting PCB Mount Material Thermoplastic, black, UL 94V-0 Termination Style THT Terminals Weight 30g Factory Pack Qty 1 Climatic Category 40/125/21 acc. to IEC 60068-1 Isolation 2.5kV VDE/UL/CSA/ROHS Yes Datasheet Product Datasheet Alternatives , Obsolete replaced by IX-30-0001 Note 45 Degree change in pin out. Or Contact Us for Possible Replacement
$7.04
$8.31 inclGST -
ITRB-0249-D101, Pulse Transformer 2:1, Ign = 100mA
Schurter ITRB-0249-D101, Pulse Transformer Features High insulation rating (>3.2 kVAC) between the primary and the secondary windings High insulation rating up to 500V between the secondary windings Small coupling capacitances between primary and secondary windings limit transient feedback from the power supply side to the control electronics The defined partial discharge voltage guarantees an effecively unlimited serviceable live Applications Galvanic separation of drive and power-circuit Mainly used in ignition circuits with Thyristors, Triacs, power transistors and IGBT's DC/DC converters Line coupling transformers in high speed data transmission Specification Schurter Part Number ITRB-0249-D101 Rated Voltage 600V Rated Current (Iz) 100mA Inductance 1.4mH Transformer Ratio 1:1:1 Rated Power (Pm) 0.5W Resistance (RL) 10Ω Rise Time (Tr) 0.3uS Operating Temperature -25°C to 100°C Mounting PCB Mount Material Thermoplastic, black, UL 94V-0 Termination Style THT Terminals Weight 9g Factory Pack Qty 1 Climatic Category 40/125/21 acc. to IEC 60068-1 Isolation 3.5kV VDE/UL/CSA/ROHS Yes Datasheet Product Datasheet
$9.05
$10.68 inclGST -
5500.2062, 2 Stage EMC (RFI) Line Filter, FSW2.65.10/5 10A, 250VAC, Very High Symmetrical and Asymmetrical Attenuation
Schurter 5500-2062, 2 Stage EMC (RFI) Line Filter for Single Phase systems Features Line filter in standard and medical version 2-stage - high attenuation Characteristics Designed for standard applications Protection against interference voltage from the mains Possible interferences generated in the equipment are strongly attenuated Universal line filter for standard applications Suitable for use in equipment according to IEC/UL 60950 Other Versions on Request Version with wire connection Version with varistor for overvoltage protection Specification Schurter Part Number 5500-2062 Rated Voltage 250V Rated Current 10A Filter Stages 2 Stage Operating Temperature -25°C to 85°C Filter Type Very High Symmetrical and Asymmetrical Attenuation Leakage Current 0.25mA Mounting Panel Mount - Case 48 Material Metal Termination Style Screw Weight 275g Factory Pack Qty 10 Protection Class Suitable for appliances with protection class I acc. to IEC 61140 Isolation 1.7kV VDE/UL/CSA/ROHS Yes Datasheet Product Datasheet
$46.00
$54.28 inclGST