Fastron FAN120-FG-R , 120mm 94CFM 240VAC Fan, with Finger Guard and 41A111AR Temp Control Relay, Panel Mount and Din Rail Mount, Relay output, Dual Setpoint -10 to 55 Deg C Range
3-digit display (0.5s response)
CE/ROHS Approved
Each unit needs just 17.5mm width Din Rail space
EC Compliant
Specification
GIC Controls Part Number
41A111AR
Control Output
Relay NO 5 Amp/NC 3 Amp (Resistive)
Input
Internal NTC Sensor
Mounting Style
17.5 x 75mm Din Rail Mount
Supply Voltage
110 - 240VAC
Termination Style
Screw
Weight
230g
Factory Pack Qty
1
ROHS
Yes
CE
Yes
Datasheet
Datasheet
Trent FGM6DC-2PL-320 160A, 2 Pole DC Moulded Case Circuit Breaker (MCCB) Fixed Type 20kA 160 Amp, 1000VDC
Miniature Circuit Breakers are used for over-current (overload and short-circuit) protection of installations and devices, and as a disconnector in case of electric shock
Features :
2 Pole Disconnect
20kA Short Circuit Rating @1000VDC
Suitable for DC Power Systems Including Solar and Battery
Standards :
IEC/EN 60947-3
IP20 (IP40 Installed) IEC 61008
Specification
Trent Part Number
FGM6DC-2PL-320 160A
Functions
2 Pole DC MCCB
Nominal Voltage
1000VDC
Nominal Current Range
160 Amps
Trip Delay Time
< 50ms
Operating Temperature
-35 to 70 Deg C
Electrical Operations
5,000 Ops
Insulation Voltage
1500V
Short Circuit Current Ics=Icu
20kA @ 1000VDC
Approvals
CE
Standards
GB/T14048.2, IEC/EN 60947-3, IP20 (IP40 Installed)
Weight
2.2kg
Enclosure Material
UL94
Factory Pack Qty
1
Datasheet
Product Datasheet
CE Declaration
Sanrex BKA400AA10, Schottky Diode Rectifier Module, 400 Amp, 100V, Isolated TO-244 Package
Features
Pressure Contact Technology
Electrically insulated base plate
Very low forward voltage drop
Very low leakage current
Planar passivated chips
International standard package
2500V Isolation
20mm Base Width
Applications
Power Supplies
Rectifier for drives applications
Uncontrolled Rectifiers
Rectifiers for UPS
Battery Chargers
Filed Supply for DC Motors
DC supply for PWM inverter
Specification
Sanrex Part Number
BKA400AA10
Vrrm
100V
Diode Configuration
Schottky Diode Rectifier - Common Cathode
IF(av) @ 125 Deg C (50% Duty)
400 Amp per device, 200 Amp per leg
Package Size
W:20mm L:93mm D:16.5mm
Itsm
3.62 kA
VF(to)
0.78 -> 0.93V
Tj(max)
150°C
rF
Not Published
Terminals
1/4"-20UNC
Hole Centres
80mm (M6)
Gate Terminals
N/A
R th(j-c)
R th(c-h)
0.20°C/W
Weight
68g
Mounting Torque
40 Nm (40 Nm Terminals)
Factory Pack Qty
10
Certification
UL Listed, ROHS
Sanrex Headquarters
Japan
Datasheet
Product datasheet
Trent DSTO-MAU-5F-R-0.8M-N-H-SP1, Power Distribution Unit (PDU) with IEC Inlet Male AU Plug via 10.5M Cable, to 5 x F/C13 Outlet, 240VAC @ 10 Amp with Rocker Switch, Rack Mounted, with Overload Protection, MOQ = 10pcs (if not in stock), Metal Construction
Features
1 x Male Australian Plug in 5 x F/C13 out, Ganged Distribution Outlet
Male Australian Plug & F Socket Socket acc to IEC 60320-1
70 °C pin Temperature
Rocker Switch Protected
Suitable for use in equipment according to IEC/UL 60950
OTHER SIZES CAN BE MADE TO ORDER
Characteristics
UL 60320-1, CSA C22.2 no. 60320-1 (for hot conditions) pin-temperature 70 °C, 10A, Protection Class I
Types for enhanced glow wire test requirements acc. IEC 60695-2- 12 and -13 for the use in unattended household equipment acc. IEC 60335-1
Specification
Trent Part Number
DSTO-MAU-5F-R-0.8M-N-H-SP1 (PDUC1305ST10AUG)
Rated Voltage
250V
Rated Current
10A
No of Outlets
5
Operating Temperature
-25°C to 120°C
Filter Type
N/A
Overload Protection
YES
Line Switch
Rocker Switch - 10 Amp (red Illumination)
Mounting
Rear Mounted with Plastic Hooks
Material
Powder Coated Metal black
Termination Style
1 x Male AU Plug Inlet (via 0.5M Cable), 5 x F/C13 Outlet
Weight
2000g
Factory Pack Qty
1
Protection Class
From front side IP30 acc. to IEC 60529
Isolation
2kV (L-N, L/N-E)
VDE/UL/CSA/CE/ROHS
Datasheet
Product Datasheet
MS Power MSD83N16UB, Rectifier Diode 83 Amp, 1600V, 1/4" UNF, Cathode stud
Features
Full blocking capability over wide temperature range
Hermetic metal case with glass insulator
Threaded stud
Applications
Power Supplies
Uncontrolled Rectifiers
Oil Cooled Circuits
Battery Chargers
Specification
MS Power Part Number
MSD83N16UB
Vrrm
1600V
Diode Configuration
Cathode Stud
IF(av) @ 140 Deg C
85 Amp
Itsm
1.15 kA
VF(to)
0.85V
Tj(max)
180°C
rF
3mΩ
Termination Style (Tail)
8.2mm Round Lug
Termination Style (Stud)
1/4" 28UNF 2A
Tail Length to Stud
158mm
R th(j-c)
0.55°C/W
R th(c-h)
0.20°C/W
Weight
40g
Mounting Torque
4 Nm
Factory Pack Qty
10
Country Of Origin
China
MS Power Headquarters
Germany
Datasheet
Product Datasheet
A53TP50D + HS212DR, Solid State Relay, and Heatsink Assembly, 3 Phase 90-280VAC Control, 20 Amp per phase @ 40 Deg C, 48-530VAC Load, LED Status Indicator
Features
Ratings from 25A to 50 Amp @ 70-530 VAC
SCR output for heavy industrial loads
Zero voltage or Instantaneous turn-on outputs
UL/CE/ROHS Approved
IP20 Cover Available
AC & DC control types
Direct bond copper substrate
Direct power lead frame
Epoxy free design
Spec
Crydom Part Number
A53TP50D + HS212DR
Switching Type
Zero Crossing
ROHS/CE/UL
Yes
Control Voltage
90-280VAC
Load Current
3 x 20 Amp (rms) per Phase
Surge Capability
597 Amp (peak)
Special Feature
LED Status Indicator
Mounting Style
Din Rail Mount
Load Voltage Range
48-530VAC
EMC Compliant
Level 3
Termination Style
Screw
Unit Weight
315g
Factory Pack Qty
10
Datasheet
D53TP Series
3 Phase SSR and Heatsink Mounted
HS212 Datasheet
App Notes
Why Use SSR's?
The inside story
Selecting a SSR
DC Output SSR's
Selecting a Suitable Heatsink
Use of Thermal Interface Material
How to Verify the Proper Heatsink
Effect of Forced Air Cooling
Fuse Protection of SSR's
Overvoltage Protection "P" Option MOV
SSR Reliability Whitepaper
3 Phase Motors and Heating Applications
3 Phase Motor Reversing
How to test a SSR
SSR Precautions
SSR Life Expectancy MTBF
ROHS & Reach Statement
Heatsink
SSR and Heatsink Assemblies
D53TP50D + HS212DR-F, Solid State Relay, and Heatsink Assembly, 3 Phase 4-32VDC Control, 36 Amp per phase @ 40 Deg C, 48-530VAC Load, LED Status Indicator
Features
Ratings from 25A to 50 Amp @ 70-530 VAC
SCR output for heavy industrial loads
Zero voltage or Instantaneous turn-on outputs
UL/CE/ROHS Approved
IP20 Cover Available
AC & DC control types
Direct bond copper substrate
Direct power lead frame
Epoxy free design
Spec
Crydom Part Number
D53TP50D + HS212DR-F
Switching Type
Zero Crossing
ROHS/CE/UL
Yes
Control Voltage
4-32VDC
Load Current
3 x 36 Amp (rms) per Phase
Surge Capability
597 Amp (peak)
Special Feature
LED Status Indicator
Mounting Style
Din Rail Mount
Load Voltage Range
48-530VAC
EMC Compliant
Level 3
Termination Style
Screw
Unit Weight
315g
Factory Pack Qty
10
Datasheet
D53TP Series
3 Phase SSR and Heatsink Mounted
HS212 Datasheet
App Notes
Why Use SSR's?
The inside story
Selecting a SSR
DC Output SSR's
Selecting a Suitable Heatsink
Use of Thermal Interface Material
How to Verify the Proper Heatsink
Effect of Forced Air Cooling
Fuse Protection of SSR's
Overvoltage Protection "P" Option MOV
SSR Reliability Whitepaper
3 Phase Motors and Heating Applications
3 Phase Motor Reversing
How to test a SSR
SSR Precautions
SSR Life Expectancy MTBF
ROHS & Reach Statement
Heatsink
SSR and Heatsink Assemblies
A53TP50D + HS212DR-F, Solid State Relay, and Heatsink Assembly, 3 Phase 90-280VAC Control, 36 Amp per phase @ 40 Deg C, 48-530VAC Load, LED Status Indicator
Features
Ratings from 25A to 50 Amp @ 70-530 VAC
SCR output for heavy industrial loads
Zero voltage or Instantaneous turn-on outputs
UL/CE/ROHS Approved
IP20 Cover Available
AC & DC control types
Direct bond copper substrate
Direct power lead frame
Epoxy free design
Spec
Crydom Part Number
D53TP50D + HS212DR-F
Switching Type
Zero Crossing
ROHS/CE/UL
Yes
Control Voltage
90-280VAC
Load Current
3 x 36 Amp (rms) per Phase
Surge Capability
597 Amp (peak)
Special Feature
LED Status Indicator
Mounting Style
Din Rail Mount
Load Voltage Range
48-530VAC
EMC Compliant
Level 3
Termination Style
Screw
Unit Weight
315g
Factory Pack Qty
10
Datasheet
D53TP Series
3 Phase SSR and Heatsink Mounted
HS212 Datasheet
App Notes
Why Use SSR's?
The inside story
Selecting a SSR
DC Output SSR's
Selecting a Suitable Heatsink
Use of Thermal Interface Material
How to Verify the Proper Heatsink
Effect of Forced Air Cooling
Fuse Protection of SSR's
Overvoltage Protection "P" Option MOV
SSR Reliability Whitepaper
3 Phase Motors and Heating Applications
3 Phase Motor Reversing
How to test a SSR
SSR Precautions
SSR Life Expectancy MTBF
ROHS & Reach Statement
Heatsink
SSR and Heatsink Assemblies
FTH6053ZD3 + HS212DR, Solid State Relay, and Heatsink Assembly, 3 Phase 3-32VDC Control, 20 Amp per phase @ 40 Deg C, 48-530VAC Load, LED Status Indicator, with IP20 Cover
Features
Ratings from 25A to 50 Amp @ 70-530 VAC
SCR output for heavy industrial loads
Zero voltage or Instantaneous turn-on outputs
UL/CE/ROHS Approved
IP20 Cover Available
AC & DC control types
Direct bond copper substrate
Direct power lead frame
Epoxy free design
Spec
Fastron Part Number
FTH6053ZD3 + HS212DR
Switching Type
Zero Crossing
ROHS/CE/UL
Yes
Control Voltage
3-32VDC
Load Current
3 x 20 Amp (rms) per Phase
Surge Capability
597 Amp (peak)
Special Feature
LED Status Indicator, with IP20 Cover
Mounting Style
Din Rail Mount
Load Voltage Range
48-530VAC
EMC Compliant
Level 3
Termination Style
Screw
Unit Weight
315g
Factory Pack Qty
10
Datasheet
HS212 Datasheet
D53TP Series
3 Phase SSR and Heatsink Mounted
App Notes
Why Use SSR's?
The inside story
Selecting a SSR
DC Output SSR's
Selecting a Suitable Heatsink
Use of Thermal Interface Material
How to Verify the Proper Heatsink
Effect of Forced Air Cooling
Fuse Protection of SSR's
Overvoltage Protection "P" Option MOV
SSR Reliability Whitepaper
3 Phase Motors and Heating Applications
3 Phase Motor Reversing
How to test a SSR
SSR Precautions
SSR Life Expectancy MTBF
ROHS & Reach Statement
Heatsink
SSR and Heatsink Assemblies