Search results for "텔레@coinsp24^^소액결제세탁trc20사는법"
-
PAM 200-068 cv4D (K) Snubber Capacitor ø40 x 120mm 2kVAC 0.68uF, Railway Grade
Free Aus Post Shipping for $300 SpendPAM 200-068 cv4D (K) Snubber Capacitor ø40 x 120mm 2kVAC, Railway Grade 0.68uF Characteristics and utility Railway grade 2kVAC rms 0.68uF Resin end sealing Fastron terminal Suitable for hazardous environments Stud Mount Standards IEC 60831-1/2 EN 60831-1/2 Specification LeClanche Part Number PAM 200-068 cv4D (K) Technology Dielectric of Metallized Polypropylene Dimensions ø40 x 120mm Standards IEC 60831-1/2, EN 60831-1/2 Voltage (DC) N/A Voltage (AC) 2kVAC rms Capacitance 0.68uF Tolerance On Capacitance +/- 10% Current Ieff (max) 18 Amp Repetitive Peak Current Icr (max) N/A Surge Voltage (Us) N/A Peak Voltage Ucr N/A ESL < 45nH Mounting M12 Stud Climate Category -25/+70°C Termination Style 6.3 x 0.8mm Faston Unit Weight 190g Factory Pack Quantity 1 Datasheet Product Datasheet Equivalents Alternative
-
MT418 SUNAA, Programmable AC Current Transducer, Single Phase, 50/60Hz 12A AC input, 20-300VDC or 48-276VAC Aux Supply, Fully Programmable 0-10V or 4-20mA output, Standard Verison
Iskra Doo MT418 SUNAA, Programmable AC Current Transducer, Single Phase, 50/60Hz 12A AC input, 20-300VDC or 48-276VAC Aux Supply, Fully Programmable 0-10V or 4-20mA output, Standard Verison Class 0.5 (EN 60688) USB Comms as standard 0-10V or 4-20mA analogue output modules RMS values of current Simpel setting with USB self powered port Features : Measurement of nominal CT Current 0-12Amp Accuracy class 0.5 Input frequency 16 - 400 Hz RS 232/RS485 communication up to 115,200 bit/s or USBcommunication MODBUS RTU communication protocol Up to 4 inputs or outputs (pulse outputs, alarm outputs, tariff inputs) Universal Supply 24-300VDC or 40-276VAC User-friendly PC MiQen software Specification Iskra Doo Part Number MT418 SUNAA Functions Single Phase AC Current Transducer Supply Voltage 24-300VDC or 40-276VAC Nominal Measurement Range 1,5,10 Amp Maximum Measurement Range 12 Amp Alarm N/A Tariff Input N/A Accuracy Class 0.5 Battery Backup N/A Real Time Clock 1min/month (30ppm) Isolation 3.5kV Comms USB (standard) RS232 2400-115200 b/s (Optional RS485) Weight 340g Enclosure Material UL94 Factory Pack Qty 1 EU Directives EN61010, EN60688,EN61326-1,60529,60068-2-1/-2/-6/-27/-30 Safety Protection Class II 600V rms, installation category II 300V rms, installation category III Pollution Degree 2 in compliance with SIST EN 61010-1:2002 Enclosure Material PC/ABS non combustable-self-extinguishability, complying with UL 94 V-0 Enclosure Protection IP20 Shock Withstand 300g 8ms Pulse . 6 Shocks in each of 3 axes Vibration Withstand 0.7g, 3...100Hz, 1oct/min 10 cycles in each of three axes Operating Temperature -20 →+70 °C Datasheet Product Datasheet Software MiQen Setting Software
$336.00
$396.48 inclGST -
IK40-22-230VAC, 4 Pole 2 x SPST NO, Configuration_2 x SPST (2 x NC) Modular Contactor 440VAC 40 Amp, 240VAC/220VDC 40-500Hz Control Voltage, Hum Free
Free Aus Post Shipping for $300 spendIskra IK40-22-230VAC 4 Pole 2 x SPST NO, Configuration_2 x SPST (2 x NC) Modular Contactor 440VAC 40 Amp, 240VAC/220VDC Control Voltage, Can Replace MC-40-240-2NO2NC Features 40 Amp (rms) @ 440VAC DIN Rail Mount Changeover Contact Slim package CE Compliant to IEC 60664 IP20 Specification Fastron Part Number IK40-22-230VAC Switching Type 2 x SPST NO, Configuration_2 x SPST (2 x NC) Approvals CE Coil Voltage 230VAC/220VDC 40-500Hz Load Current (RMS/DC) 40 Amp (rms) @ 440VAC Special Feature Hum Free Mounting Style DIN Rail Mount Load Voltage Range 440VAC 40-500Hz Isolation 4kV Termination Style Screw Unit Weight 295g Factory Pack Qty 20 Datasheet Contactor Datasheet
-
FTCK-PIPE-3000, Type K Clamp Style Thermocouple for Pipes, Various Clamp Sizes, 3000mm 2 Wire Braided SS/Fibreglass/Teflon Wire, CE, ANSI, ROHS Approved
Free Aus Post Shipping for $300 SpendFastron FTCK-PIPE-3000, Type K Clamp Style Thermocouple for Pipes, Various Clamp Sizes, 3000mm 2 Wire Braided SS/Fibreglass/Teflon Wire, CE, ANSI, ROHS Approved Features Class A Accuracy Pipe Clamp Style Sensor Low Long Term Drift Rated for -20 to 370 Deg C Max 3000mm Tail Length Available in custom lengths Fibreglass Sheath Specification Fastron Part Number FTCK-PIPE-3000 Sensor Type Type K Thermocouple Ungrounded No of Wires 2 TailLength 3000mm or custom Clamp Size 7/32 -> 5/8", 3/8 -> 1/2", 3/8 -> 5/8", 1/2 -> 5/8", 5/8 -> 3/4", 3/4 -> 1", 1 1/4 -> 1 1/2", 1 1/4 -> 1 3/4", 1 1/2 -> 2", 1 3/4 -> 2 1/4", 2 1/16 -> 3", 2 5/16 -> 3 1/4", 3 -> 3 1/4", 3 - 1/4", 3 -> 3 1/2", 4 -> 4 1/2", 4 1/6 -> 5", 4 5/8 -> 5 1/2", 5 1/8 -> 6", 5 7/8 -> 6 3/4" Sheath Material Fibreglass Accuracy Class A Cable Type Briaded SS/Fibreglass/Teflon Temperature Range -20 to 370 Deg C Special Feature Pipe Clamp Mounting Style Clamp Weight 300-500g Factory Pack Qty 1 Datasheet Product Datasheet
-
FGC1-F800-230VAC, AC Contactor, 240VAC Control Voltage, 3 Pole NO, Nominal Current = 800 Amps(AC-3) @ 240/400/500/690V
Fastron Electronics FGC1-F800-230VAC, AC Contactor, 240VAC Control Voltage, 3 Pole NO, Nominal Current = 800 Amps(AC-3) @ 240/400/500/690V Contactors are designed to meet the requirements of heavy Duty applications. Contactors may be fitted with auxiliary contacts. Peak current is limited to the value within the contactor making capacity. Features : High contact reliability at low voltages High electrical and mechanical endurance and high switching capacity Four and Three-pole contactors Optional auxiliary contacts Ratings from 6 Amp to 1000 Amp CE, CB Approved Advantages : Saves costs of expensive replacement Long electrical life Reduces watt losses during “ON” condition, saves energy High safety No risk of dangerous voltage Less maintenance and downtime Standard control voltages: 24 V 50/60 Hz, 240 V 50/60 Hz, 415 V 50/60 Hz Specification Fastron Electronics Part Number FGC1-F800-230VAC Functions 3 Pole Contactor Nominal Voltage 230/400/500/690VAC @ 50/60Hz Current Carrying Capacity as per UL 800 Amp Continuous @ 55 Deg C Main Contacts 3 x NO Aux Contacts None Trip Delay Time 2-10ms Electrical Life 1,000,000 Ops Operating Temperature -25 to 55 Deg C Mechanical Operations 6,000,000 Ops Control Voltage 240VAC Pole Resistance (avg) 0.35m Ohm Approvals CE, CB, TUV, LVD Standards IEC/EN 60947-4-1, AS/NZ 61009-1 Weight 2kg Enclosure Material UL94 Factory Pack Qty 1 Datasheet Product Datasheet
$775.00
$914.50 inclGST -
FGM6DC-2PL-800 700A, 2 Pole DC Moulded Case Circuit Breaker (MCCB) Fixed Type 20kA 700 Amp, 1500VDC
Heavy Item - No Free ShippingTrent FGM6DC-2PL-800 700A, 2 Pole DC Moulded Case Circuit Breaker (MCCB) Fixed Type 20kA 700 Amp, 1500VDC Miniature Circuit Breakers are used for over-current (overload and short-circuit) protection of installations and devices, and as a disconnector in case of electric shock Features : 3 Pole Disconnect 20kA Short Circuit Rating @1000VDC Suitable for DC Power Systems Including Solar and Battery Standards : IEC/EN 60947-3 IP20 (IP40 Installed) IEC 61008 Specification Trent Part Number FGM6DC-2PL-800 700A Functions 2 Pole DC MCCB Nominal Voltage 1500VDC Nominal Current Range 700 Amps Trip Delay Time < 50ms Rated Impulse Voltage 12kV Operating Temperature -35 to 70 Deg C Electrical Operations 5,000 Ops Insulation Voltage 1500V Short Circuit Current (Ics/Icu) 20kA Approvals CE Standards GB/T14048.2, IEC/EN 60947-3, IP20 (IP40 Installed) Weight 8.5kg Enclosure Material UL94 Factory Pack Qty 1 Datasheet Product Datasheet CE Declaration
-
FRS3-C40-600R, 600VDC Surge Protection Device for Photovoltaic Systems, Type 1 (Class I) + Type 2 (Class II) 40kA WITH REMOTE C/O CONTACTS
FRS3-C40-600R, 600VDC Surge Protection Device for Photovoltaic Systems, Type 1 (Class I) + Type 2 (Class II) 40kA WITH REMOTE C/O CONTACTS Specifications Trent part number FRS3-C40-600R Nominal Voltage 600VDC No of Poles 3 Category IEC / EN / VDE Type 1 (Class I) + Type 2 (Class II) Location of use String Box, Inverter Protection modes (+)-PE,(-)-PE,(+)-(-) PE Additional Remote Contacts YES NO/NC/COM Protective element MOV No Fault/Fault Indication Green Flag / Not Green Flag Surge discharge rating Per pole 40kA (8/20uS)9KA) Max, 20kA (8/20uS)9KA) Nominal Internal protection and safety Thermal disconnector in each MOV Weight 420g Standards IEC614643-31:2018 (TUV, CE Approved) Datasheet Product Datasheet GDT/MOV/TVS Tester SPD Tester
$99.00
$116.82 inclGST -
Thyro ECO A1A 400-50 E L3, Thyro-A-1A-ECO Series Single Phase SCR Controller 50 Amp 230VAC +10%/-57%, Voltage Control only, Phase(VAR), Burst(TAKT), Switch Operating Mode
Advanced Energy Thyro ECO A1A 400-50 E L3, Thyro-A-1A-ECO Series Single Phase SCR Controller 50 Amp 230VAC +10%/-57%, Voltage Control only, Phase(VAR), Burst(TAKT), Switch Operating Mode Features 230VAC +10%/-57%, Voltage Control only +10/-57% Voltage Control Smallest footprint on the market 3 Phase, Phase Angle & Burst Controller with SWITCH operation mode SWITCH between Phase(VAR) or Burst(TAKT) control modes (0)4-20mA, 0(1)-5V, 0(2)-10V or POT input Proportional Control Fully enclosed IP20 Phase Angle(VAR), and Burst Fire(TAKT) switching Removable Cover USB Configuration/Bias Setting Synchronisation Function Digital Alarm Output Load Monitoring Applications Electrical Ovens, Kilns, or Furnaces Primary Control of Transformer Loads in Phase or Burst Fire mode AC Soft Starter (Combined with PLC) Power Regulation Applications Electric Boilers Brewery Heating Industrial Light Dimming Suitable for extreme environments such as mining Special Features Economic Model Specification Advanced Energy Part Number Thyro ECO A1A 400-50 E L3 Approvals CE, UL508A, EU Directive 2014/35/EU & 2004/108/EC Control Accuracy 3% at rated voltage Rated Operating Temperature 45°C SCR Configuration 3 Phase AC Switch Control Input 4(0)-20mA, 0(1)-5V, 0(2)-10V, POT Load Current 25 to 125 Amp @ 45 Deg C (110% @ 35 Deg C Max) Control Range 0-100% Options Conformal Coating for Gas or High Humidity Environments Mounting Style Panel Mount Supply Voltage Range 230VAC +10%/-57%, Voltage Control only +10/-15% (-57% with 24VDC Aux Supply) Soft Start Via PLC input Termination Style Screw Unit Weight 2.1 to 10kg Factory Pack Qty 1 Technical Docs Brochure User Manual Thyro A Series Quick Installation Guide Setting Up Comms on Thyro A Series Controllers Anybus Device Ethernet IP Setup Guide
$1,400.85
$1,653.00 inclGST -
FRS3-C40-1250R, 1250VDC Surge Protection Device for Photovoltaic Systems, Type 1 (Class I) + Type 2 (CLass II) 40kA WITH REMOTE C/O CONTACTS
FRS3-C40-1250R, 1250VDC Surge Protection Device for Photovoltaic Systems, Type 1 (Class I) + Type 2 (Class II) 40kA WITH REMOTE C/O CONTACTS Specifications Trent part number FRS3-C40-1250R Nominal Voltage 1250VDC No of Poles 3 Category IEC / EN / VDE Type 1 (Class I) + Type 2 (Class II) Location of use String Box, Inverter Protection modes (+)-PE,(-)-PE,(+)-(-) PE Additional Remote Contacts YES NO/NC/COM Protective element MOV No Fault/Fault Indication Green Flag / Not Green Flag Surge discharge rating Per pole 40kA (8/20uS)9KA) Max, 20kA (8/20uS)9KA) Nominal Internal protection and safety Thermal disconnector in each MOV Weight 420g Standards IEC614643-31:2018 (TUV, CE Approved) Datasheet Product Datasheet GDT/MOV/TVS Tester SPD Tester
$129.00
$152.22 inclGST -
FRS3-C40-150R, 150VDC Surge Protection Device for Photovoltaic Systems, Type 1 (Class I) + Type 2 (Class II) 40kA WITH REMOTE C/O CONTACTS
FRS3-C40-150R, 150VDC Surge Protection Device for Photovoltaic Systems, Type 1 (Class I) + Type 2 (Class II) 40kA WITH REMOTE C/O CONTACTS Specifications Trent part number FRS3-C40-150R Nominal Voltage 500VDC No of Poles 3 Category IEC / EN / VDE Type 1 (Class I) + Type 2 (Class II) Location of use String Box, Inverter Protection modes (+)-PE,(-)-PE,(+)-(-) PE Additional Remote Contacts YES NO/NC/COM Protective element MOV No Fault/Fault Indication Green Flag / Not Green Flag Surge discharge rating Per pole Imax = 40kA (8/20uS) 9KA Max, In = 20kA (8/20uS) 9KA Nominal, Iimp = 8kA (10/350us) Internal protection and safety Thermal disconnector in each MOV Weight 420g Standards IEC614643-31:2018 (TUV, CE Approved) Datasheet Product Datasheet GDT/MOV/TVS Tester SPD Tester
$95.00
$112.10 inclGST -
Thyro ECO A1A 400-80 E L3, Thyro-A-1A-ECO Series Single Phase SCR Controller 80 Amp 230VAC +10%/-57%, Voltage Control only, Phase(VAR), Burst(TAKT), Switch Operating Mode
Advanced Energy Thyro ECO A1A 400-80 E L3, Thyro-A-1A-ECO Series Single Phase SCR Controller 80 Amp 230VAC +10%/-57%, Voltage Control only, Phase(VAR), Burst(TAKT), Switch Operating Mode Features 230VAC +10%/-57%, Voltage Control only +10/-57% Voltage Control Smallest footprint on the market 3 Phase, Phase Angle & Burst Controller with SWITCH operation mode SWITCH between Phase(VAR) or Burst(TAKT) control modes (0)4-20mA, 0(1)-5V, 0(2)-10V or POT input Proportional Control Fully enclosed IP20 Phase Angle(VAR), and Burst Fire(TAKT) switching Removable Cover USB Configuration/Bias Setting Synchronisation Function Digital Alarm Output Load Monitoring Applications Electrical Ovens, Kilns, or Furnaces Primary Control of Transformer Loads in Phase or Burst Fire mode AC Soft Starter (Combined with PLC) Power Regulation Applications Electric Boilers Brewery Heating Industrial Light Dimming Suitable for extreme environments such as mining Special Features Economic Model Specification Advanced Energy Part Number Thyro ECO A1A 400-80 E L3 Approvals CE, UL508A, EU Directive 2014/35/EU & 2004/108/EC Control Accuracy 3% at rated voltage Rated Operating Temperature 45°C SCR Configuration 3 Phase AC Switch Control Input 4(0)-20mA, 0(1)-5V, 0(2)-10V, POT Load Current 25 to 125 Amp @ 45 Deg C (110% @ 35 Deg C Max) Control Range 0-100% Options Conformal Coating for Gas or High Humidity Environments Mounting Style Panel Mount Supply Voltage Range 230VAC +10%/-57%, Voltage Control only +10/-15% (-57% with 24VDC Aux Supply) Soft Start Via PLC input Termination Style Screw Unit Weight 2.1 to 10kg Factory Pack Qty 1 Technical Docs Brochure User Manual Thyro A Series Quick Installation Guide Setting Up Comms on Thyro A Series Controllers Anybus Device Ethernet IP Setup Guide
$1,758.24
$2,074.72 inclGST -
KNL400-00-240VAC, AC Contactor 240/400/500/690V, 3 Pole 3 x NO, Nominal Current = 400 Amps, 240VAC Coil
Heavy Item - No free ShippingIskra Doo KNL400-00-240VAC, AC Contactor 240/400/500/690V, 3 Pole 3 x NO, Nominal Current = 400 Amps, 240VAC Coil Capacitor duty contactors are designed to meet the requirements of capacitor duty applications. Contactors are fitted with a block of three auxiliary contacts connected in series with six quick discharge damping resistors, two per each phase. Peak current is limited to the value within the contactor making capacity. Features : High contact reliability at low voltages High electrical and mechanical endurance and high switching capacity Four and Three-pole contactors Optional auxiliary contacts Ratings from 6 Amp to 1000 Amp UL, CSA Approved Advantages : Saves costs of expensive replacement Long electrical life Reduces watt losses during “ON” condition, saves energy High safety No risk of dangerous voltage Less maintenance and downtime Standard control voltages: 24 V 50/60 Hz, 240 V 50/60 Hz, 415 V 50/60 Hz Specification Iskra Doo Part Number KNL400-00-240VAC Functions 3 Pole Contactor (3 x NO) Nominal Voltage 230/400/500/690VAC @ 50/60Hz Current Carrying Capacity as per UL 400 Amp Continuous @ 55 Deg C Auxiliary Contacts Optional Snap On up to Four G350 (2NO + 1NC or 1NO+2NC Depending on mounting position) Trip Delay Time 2-10ms Electrical Life 700,000 Ops Operating Temperature -25 to 55 Deg C Mechanical Operations 10.000,000 Ops Control Voltage 240VAC Power Dissipation 52.5W per pole Approvals UL, CSA Standards IEC/EN 60947-4-1, AS/NZ 61009-1 Weight 9.5kg Enclosure Material UL94 Factory Pack Qty 1 Datasheet Product Datasheet Contactor Catalogue Iskra Contactor Catalogue