Search results for "텔래그램@bitcoinsyri:♢환치기이더리움사는곳"
-
88827103 Timer Chronos2 MUR3 20-30VDC & 20- 264 VAC, Can be replaced by BM1R05MV1 (5 Amp)
Timer Chronos2 88827103 Timer Chronos2 MUR3 20-30VDC & 20- 264 VAC, Can be replaced by BM1R05MV1 (5 Amp) MUR3 Timers Syrline 17.5 mm - 1 C/O Relay 8A : Multi-range (0.1s - 100hrs) Multi-voltage 12 →240 V AC/DC LED status indicator Possibility of external load connection in parallel to the control input 3-wire PNP sensor compatible Multifunction Timers Includes The Following : Function A Delay on energisation 1 relay Function Ac Timing after closing and opening of control contact 1 relay Function At Timing on energisation with memory 1 relay Function B Timing on impulse one shot 1 relay Function Bw Timing pulse output (adjustable) Function C Timing after impulse 1 relay Function D Flip-flop Pause start 1 relay Function Di Flip-flop Pulse start 1 relay Function H Timing on energisation 1 relay Function Ht Delay on energisation with memory 1 relay Specification Crouzet Part Number 88827103 (Syr-Line Timer SinglePole Double Throw 1 x 8A Multifunction, 12 - 240VAC/DC, 17.5 mm) Function Multifunction Timer A - Ac - At - B - Bw - C - D - Di - H - Ht Nominal Voltage 12 → 240 V AC/DC Digital Output 1 x C/O (DPDT) (Changeover -Single Pole Double Throw-), 250VAC/DC @ 8 Amp Min Breaking Current 10mA/12VDC Timing Ranges Selectable 0.1s - 1s - 10s - 1 min - 10min - 1h, 10h, 100h Minimum Pulse Duration 30ms/100ms with load Repeatability 0.5% Reset Time 120ms Isolation 4kV Repetition Accuracy 0.5% Threshold Adjustment Range 10 → 100 % of the range Termination Style Screw Weight 80g Certification CE, cULus,CCC, ROHS, Reach, WEEE Factory Pack Qty 1 Over Voltage Category 3 in accordance with IEC/EN 60664-1 Pollution Degree 2 in accordance with IEC/EN 61131-2 Protection rating IP40 (Front), IP20 (Rear) Mechanical Resistance Immunity to vibrations IEC/EN 60068-2-6, test Fc Immunity to shock IEC/EN 60068-2-27, test Ea Resistance to HF Interference Immunity to radiated electrostatic fields IEC/EN 61000-4-3 Immunity to fast transients (burst immunity) IEC/EN 61000-4-4, level 3 Immunity to shock waves IEC/EN 61000-4-5 Radio frequency in common mode IEC/EN 61000-4-6, level 3 Voltage dips and breaks (AC) IEC/EN 61000-4-11 Immunity to damped oscillatory waves IEC/EN 61000-4-12 Conducted and radiated emissions Class B (*) in accordance with EN 55022, EN 55011 (CISPR22, CISPR11) group 1 (*) Except configuration (88 970 1.1 or 88 970 1.2) + (88 970 250 or 88 970 270) + 88 970 241 class A (class B in a metal enclosure) Operating Temperature -20 →+70 °C except CB and XB versions in VDC : -30 →+70 °C (+40 °C in a non-ventilated enclosure) in accordance with IEC/EN 60068-2-1 and IEC/EN 60068-22 Datasheet Product Datasheet Cross Reference Can Be Replaced by BM1R05MV1 (5 Amp) or BM1R16MV1 Can Be Replaced by BM1R05MV1 (5 Amp) or BM1R16MV1 Replaces MRU1
$173.35
$204.55 inclGST -
MCC26-16Io1B, Dual Thyristor Module, 26 Amp, 1600V, WithAux Cathode Connection
Westcode-IXYS-Littlefuse MCC26-16Io1B, Dual Thyristor Module, 26 Amp, 1600V, With Aux Cathode Connection Features Thyristor for line frequency Direct Copper Bonded Al2O3-ceramic Planar passivated chip Electrically insulated base plate Industrial standard package Long-term stability 3600V Isolation 20mm Base Width Applications Power Converter Line rectifying 50/60 Hz Controlled Rectifiers Softstart AC motor control AC power control Lighting and temperature control Specification Westcode-IXYS-Littlefuse Part Number MCC26-16Io1B Vrrm 1600V Diode Configuration Thyristor Diode Module IF(av) @ 85 Deg C 27 Amp Package Size W:20mm L:93mm D:30mm TO-240AA Itsm 0.52 kA VF(to) 0.85V Tj(max) 125°C rF 11mΩ I(gt) @ 25 Deg C 100mA Terminals M5 Screw Hole Centres 80mm (M6) Gate Terminals Spade (A 2.8 - 0.8 DIN 46244) (without Aux Cathode Connections) R th(j-c) 0.88°C/W R th(c-h) 0.20°C/W Weight 81g Mounting Torque 4 Nm (4 Nm Terminals) Factory Pack Qty 12 Certification UL Listed, ROHS IXYS Headquarters United States Datasheet Product Datasheet
$50.08
$59.09 inclGST -
SCT-F16-175-1A, 175/1 Amp Measurement, Class 1 Split Core CT's
Fastron Electronics SCT-F16-175-1A, 175/1 Amp Measurement Split Core Current Transformer, 16mm Aperture Features Quick Release Split Core System Cable Mount 1 Amp Output Self Powered Rated System Voltage 0.60/3kV 0.5M Flying Leads Applications US Based Metering Equipment Energy Monitoring AC Power Control Systems Power Factor Correction Power Quality Measurements Specification Fastron Part Number SCT-F16-175-1A Technology Split Core AC Current Transformer Ratio 175/1 Amp Aperture Size ø 15 mm VA Rating N/A Accuracy Class Class 1 Output 1 Amp (+20%) Isolation 3kV (AC, 50Hz, 1 min) Bandwidth 50-60Hz Mounting Style Cable Mount/Busbar Mount Operating Temperature Range -15°C / 45°C Continuous Current (max) 175Amp x 1.2 Termination Style 0.5M Flying leads Unit Weight 100g Factory Pack Qty 9 Datasheet Product Datasheet Application Notes Installation Guide
$48.00
$56.64 inclGST -
ART-B22-D175-SP3, AC Measurement Rogowski Coil (coil only). 17.5cm Diameter, Class 0.5, 3M Shielded Cable Connection
LEM ART-B22-D175-SP3, AC Measurement Rogowski Coil (coil only). 17.5cm Diameter, Class 0.5, 3M Shielded Cable Connection Flexible clip-around Rogowski coil for the electronic measurement of AC current with galvanic separation between the primary circuit (power) and the secondary circuit (measurement). The patented Perfect Loop Technology dramatically reduces both the error due to the position of the measured conductor within the aperture, and the error due to the proximity of external conductors. The ART series single phase flexible rope CT from LEM. In conjunction with AI-PMUL combined integrator & signal conditioner LEM offer True RMS 0-5V, 0-10V, 0-20mA, 4-20mA outputs, or direct linear outputs 0.333V or 0.166V Included is a 17.5cm diameter rope CT, and 1.5M of twisted pair (1000V) output leads for connection to an integrator, or meter/logger with integration function. LEM coils come with 5 year warranty Features Rated insulation voltage 1000 V Cat III PD2 Accuracy Class 0.5 (IEC 61869-2) Protection degree IP67 ? 70, ? 125, ? 175, ? 300 mm sensing aperture 3 m output cable (other lengths available see page 8) Ambient temperature ?40 °C … +80 °C Very flexible and thin coil: 6.1 mm Slot for attaching the loop on the primary with a cable tie ? 2 mm hole to pass a security seal tampering An innovative patented clasp drastically reduces the positioning error near the closing Internal shield for enhanced measurement accuracy at low primary currents. Advantages Thin, flexible, and light weight solution Very low positioning error Quick, non-intrusive and easy setup A single sensor for a large current range without overload Less influenced by external fields Adaptable for a large range of cable diameters Applications MV/LV substations on LV side: Transformer Condition Monitoring Power metering: current measurement for active power calculation Building sub-metering: energy efficiency monitoring, consumption analysis and cost allocation Power quality monitoring: electrical loads and distribution system equipment Fault Detection, Isolation and Repair (FDIR): isolate the site of the fault Remote Terminal Units (RTU) Phasor Measurement Units (PMU) Standards IEC 61010-1: 2010; IEC 61010-2-32 ed.3: 2012 1) IEC 61869-1 ed1.0: 2007; IEC 61869-2: ed1.0: 2012 1) IEC 61869-6: draft 2016; IEC 61869-10: draft 2016 UL Specification LEM Part Number ART-B22-D175-SP3 Function AC Current Measurement Measuring Range 0 - 5,000 Amp RMS (Contact Us for Possible Replacement for wider range) Secondary Voltage (Sensitivity) 22.5mV Frequency Measuring Range 50-300kHz Operating Voltage Self Powered Accuracy 0.5% from 25 to 5000 Amp Phase Angle < 0.004 Coil Diameter (?) 17.5cm Coil Circumference 55cm Integrator to Coil Cable 3M Twisted Pair Maximum Voltage 1000V Reinforced insulation according to EN 61010-1 Operating Temperature -15°C to 65°C Storage Temperature -45°C to 80°C Isolation (50Hz, 1 min) 7.4kV Overload 350,000 Amp Termination Style 2 Stripped Wires Weight 138g Factory Pack Qty 1 Certifications UL, ROHS Datasheet Product Datasheet Application Notes 1) The Rogowski coil can measure any primary current as there is no saturation effect. 2) Not tested given that in the worst case (load = 0 Ohm i.e. short circuit on the output) the peak dissipated power remains low (< 2 Watts) 3) Frequency bandwidth and phase shift modeling schematic can be provided on request. 4) Referring to the main phase offset of 90 ° (a Rogowski coil is a derivative current transducer) 5) Considering a primary conductor of at least ? 15 mm, perpendicular and in contact with the Rogowski coil. 6) Considering an external conductor of at least ? 15 mm the same current level than internal conductor, perpendicular and in contact with the Rogowski coil.
$189.00
$223.02 inclGST -
ART-B22-D70-SP3, AC Measurement Rogowski Coils (coil only). 7cm Diameter, Class 0.5, 3M Shielded Cable Connection
LEM ART-B22-D70-SP3, AC Measurement Rogowski Coils (coil only). 7cm Diameter, Class 0.5, 3M Shielded Cable Connection Flexible clip-around Rogowski coil for the electronic measurement of AC current with galvanic separation between the primary circuit (power) and the secondary circuit (measurement). The patented Perfect Loop Technology dramatically reduces both the error due to the position of the measured conductor within the aperture, and the error due to the proximity of external conductors. The ART series single phase flexible rope CT from LEM. In conjunction with AI-PMUL combined integrator & signal conditioner LEM offer True RMS 0-5V, 0-10V, 0-20mA, 4-20mA outputs, or direct linear outputs 0.333V or 0.166V Included is a 12.5cm diameter rope CT, and 1.5M of twisted pair (1000V) output leads for connection to an integrator, or meter/logger with integration function. LEM coils come with 5 year warranty Features Rated insulation voltage 1000 V Cat III PD2 Accuracy Class 0.5 (IEC 61869-2) Protection degree IP67 ? 70, ? 125, ? 175, ? 300 mm sensing aperture 3 m output cable (other lengths available see page 8) Ambient temperature ?40 °C … +80 °C Very flexible and thin coil: 6.1 mm Slot for attaching the loop on the primary with a cable tie ? 2 mm hole to pass a security seal tampering An innovative patented clasp drastically reduces the positioning error near the closing Internal shield for enhanced measurement accuracy at low primary currents. Advantages Thin, flexible, and light weight solution Very low positioning error Quick, non-intrusive and easy setup A single sensor for a large current range without overload Less influenced by external fields Adaptable for a large range of cable diameters Applications MV/LV substations on LV side: Transformer Condition Monitoring Power metering: current measurement for active power calculation Building sub-metering: energy efficiency monitoring, consumption analysis and cost allocation Power quality monitoring: electrical loads and distribution system equipment Fault Detection, Isolation and Repair (FDIR): isolate the site of the fault Remote Terminal Units (RTU) Phasor Measurement Units (PMU) Standards IEC 61010-1: 2010; IEC 61010-2-32 ed.3: 2012 1) IEC 61869-1 ed1.0: 2007; IEC 61869-2: ed1.0: 2012 1) IEC 61869-6: draft 2016; IEC 61869-10: draft 2016 UL Specification LEM Part Number ART-B22-D70-SP3 Function AC Current Measurement Measuring Range 0 - 5,000 Amp RMS (Contact Us for Possible Replacement for wider range) Secondary Voltage (Sensitivity) 22.5mV Frequency Measuring Range 50-300kHz Operating Voltage Self Powered Accuracy 0.5% from 25 to 5000 Amp Phase Angle < 0.004 Coil Diameter (?) 7cm Coil Circumference 22cm Integrator to Coil Cable 3M Twisted Pair Maximum Voltage 1000V Reinforced insulation according to EN 61010-1 Operating Temperature -15°C to 65°C Storage Temperature -45°C to 80°C Isolation (50Hz, 1 min) 7.4kV Overload 300,000 Amp Termination Style 2 Stripped Wires Weight 130g Factory Pack Qty 1 Certifications UL, ROHS Datasheet Product Datasheet Application Notes 1) The Rogowski coil can measure any primary current as there is no saturation effect. 2) Not tested given that in the worst case (load = 0 Ohm i.e. short circuit on the output) the peak dissipated power remains low (< 2 Watts) 3) Frequency bandwidth and phase shift modeling schematic can be provided on request. 4) Referring to the main phase offset of 90 ° (a Rogowski coil is a derivative current transducer) 5) Considering a primary conductor of at least ? 15 mm, perpendicular and in contact with the Rogowski coil. 6) Considering an external conductor of at least ? 15 mm the same current level than internal conductor, perpendicular and in contact with the Rogowski coil.
$173.00
$204.14 inclGST -
ART-B22-D300-SP4, AC Measurement Rogowski Coil (coil only). 30cm Diameter, Class 0.5, 4.5M Shielded Cable Connection
LEM ART-B22-D300-SP4, AC Measurement Rogowski Coil (coil only). 30cm Diameter, Class 0.5, 4.5M Shielded Cable Connection Flexible clip-around Rogowski coil for the electronic measurement of AC current with galvanic separation between the primary circuit (power) and the secondary circuit (measurement). The patented Perfect Loop Technology dramatically reduces both the error due to the position of the measured conductor within the aperture, and the error due to the proximity of external conductors. The ART series single phase flexible rope CT from LEM. In conjunction with AI-PMUL combined integrator & signal conditioner LEM offer True RMS 0-5V, 0-10V, 0-20mA, 4-20mA outputs, or direct linear outputs 0.333V or 0.166V Included is a 30cm diameter rope CT, and 1.5M of twisted pair (1000V) output leads for connection to an integrator, or meter/logger with integration function. LEM coils come with 5 year warranty Features Rated insulation voltage 1000 V Cat III PD2 Accuracy Class 0.5 (IEC 61869-2) Protection degree IP67 ⌀ 70, ⌀ 125, ⌀ 175, ⌀ 300 mm sensing aperture 3 m output cable (other lengths available see page 8) Ambient temperature −40 °C … +80 °C Very flexible and thin coil: 6.1 mm Slot for attaching the loop on the primary with a cable tie ⌀ 2 mm hole to pass a security seal tampering An innovative patented clasp drastically reduces the positioning error near the closing Internal shield for enhanced measurement accuracy at low primary currents. Advantages Thin, flexible, and light weight solution Very low positioning error Quick, non-intrusive and easy setup A single sensor for a large current range without overload Less influenced by external fields Adaptable for a large range of cable diameters Applications MV/LV substations on LV side: Transformer Condition Monitoring Power metering: current measurement for active power calculation Building sub-metering: energy efficiency monitoring, consumption analysis and cost allocation Power quality monitoring: electrical loads and distribution system equipment Fault Detection, Isolation and Repair (FDIR): isolate the site of the fault Remote Terminal Units (RTU) Phasor Measurement Units (PMU) Standards IEC 61010-1: 2010; IEC 61010-2-32 ed.3: 2012 1) IEC 61869-1 ed1.0: 2007; IEC 61869-2: ed1.0: 2012 1) IEC 61869-6: draft 2016; IEC 61869-10: draft 2016 UL Specification LEM Part Number ART-B22-D300-SP4 Function AC Current Measurement Measuring Range 0 - 5,000 Amp RMS (Contact Us for Possible Replacement for wider range) Secondary Voltage (Sensitivity) 22.5mV Frequency Measuring Range 50-300kHz Operating Voltage Self Powered Accuracy 0.5% from 25 to 5000 Amp Phase Angle < 0.004 Coil Diameter (⌀) 30cm Coil Circumference 95cm Integrator to Coil Cable 4.5M Twisted Pair / Coax Maximum Voltage 1000V Reinforced insulation according to EN 61010-1 Operating Temperature -15°C to 65°C Storage Temperature -45°C to 80°C Isolation (50Hz, 1 min) 7.4kV Overload 300,000 Amp Termination Style 2 Stripped Wires Weight 155g Factory Pack Qty 1 Certifications UL, ROHS Datasheet Product Datasheet Application Notes 1) The Rogowski coil can measure any primary current as there is no saturation effect. 2) Not tested given that in the worst case (load = 0 Ohm i.e. short circuit on the output) the peak dissipated power remains low (< 2 Watts) 3) Frequency bandwidth and phase shift modeling schematic can be provided on request. 4) Referring to the main phase offset of 90 ° (a Rogowski coil is a derivative current transducer) 5) Considering a primary conductor of at least ⌀ 15 mm, perpendicular and in contact with the Rogowski coil. 6) Considering an external conductor of at least ⌀ 15 mm the same current level than internal conductor, perpendicular and in contact with the Rogowski coil.
$215.00
$253.70 inclGST -
BI232-20-230VAC, Two Pole 2 x NO SPST, 230VAC @ 32 Amp (Resistive), 24VDC @ 32 Amp Bistable Switch/Latching Relay with Manual Control, with 230VAC Coil Voltage
Iskra BI232-20-230VAC, Two Pole 2 x NO SPST, 230VAC @ 32 Amp (Resistive), 24VDC @ 32 Amp Bistable Switch/Latching Relay with Manual Control, with 230VAC Coil Voltage Features 32 Amp (rms) @ 250VAC/18 Amp @ 24VAC/DC/10 Amp @ 48VDC/4 Amp @ 60VDC/1.2 Amp @ 110VDC/0.3 Amp @ 220VDC DIN Rail Mount Zero Power Consumption in "ON State" Slim package CE Compliant to IEC 60664 IP20 Specification Fastron Part Number BI232-20-230VAC Switch/Latching Relay Type 2 x SPST 440VAC/220VDC Approvals CE Coil Voltage 230VAC Load Current (RMS/DC) 32 Amp (rms) @ 440VAC/32 Amp @ 24VDC/18 Amp @ 48VDC/14 Amp @ 60VDC/5 Amp @ 110VDC/0.8 Amp @ 220VDC Special Feature Manual and Impulse Controlled Mounting Style DIN Rail Mount Load Voltage Range 32 Amp (rms) @ 440VAC/32 Amp @ 24VDC/18 Amp @ 48VDC/14 Amp @ 60VDC/5 Amp @ 110VDC/0.8 Amp @ 220VDC Isolation 4kV Termination Style Screw Unit Weight 60g Factory Pack Qty 20 Datasheet Relay Datasheet
$49.00
$57.82 inclGST -
SDM230Modbus-MID-V2 (SLX), DIN Rail Mount kWh Meter, Single Phase, 240VAC aux, Class 1, 100Amp Direct Connect, w/ 2 x pulse outputs and RS485 Modbus RTU Comms, MID Approved,SAA212516
Free Aus Post Shipping for $300 SpendEastron Europe SDM230Modbus-MID-V2 (SLX), DIN Rail Mount kWh Meter, Single Phase, 240VAC aux, Class 1, 100Amp Direct Connect, w/ 2 x pulse outputs and RS485 Modbus RTU Comms, MID Approved,SAA212516 Fast CPU for 100ms Communication response time For Solaxx or Growatt Inverters. Can be used for any 100 Amp Direct Connect application RS 485 communication up to 38,400 bit/s as standard Optional Mbus Model available True RMS values of currents and voltages 1 x Configurable Pule Output (via Display Menu or Modbus) 1 x Fixed Pulse Output (1000imp/kwh) SAA Approved The meter is intended for measuring, and monitoring single-phase or electrical power network. The meter records TRMS value according to the principle of fast sampling of voltage and current signals. A built-in microprocessor calculates measurands (voltage, current, frequency, energy, power to the 30th Harmonic) from the measured signals. Features : Accuracy Class 1 Measurement of Active and Reactive Power Modbus RTU communication up to 38,400 bit/s communication Pulse output as standard Graphic LCD with illumination Specification Eastron Europe Part Number SDM230Modbus-MID-V2 (SLX) Functions Single Phase Energy Meter Supply Voltage 230V L-N +/-15% < 5VA Nominal Measurement Range 230V L-N 230V L-N, 100 Amp Maximum Measurement Range 276 L-N 230V L-N,100 Amp Nominal Current Input Direct connect 100 Amp Pulse Output 2 x Passive, (1 x Configurable 60/100/200ms) Tariff Input N/A Accuracy Class 1 (I,U,F,kW,kWh) Class 2 (Reactive) Mounting Din Rail Real Time Clock 1min/month (30ppm) Internal Memory N/A Dimensions 36mm x 100mm x 66mm (2 modules wide) Isolation 4kV RS485 2400-38400 b/s (100ms Response) Weight 250g Certification EN 61010-1 Installation Category III, SAA212516 Factory Pack Qty 1 Safety IP51(Indoor) Enclosure Material Noryl with fire protection to UL94-V-O. Self extinguishing Enclosure Size DIN 42880 4 Modules Operating Temperature -20 →+70 °C Documents Product Datasheet User Manual Modbus Protocol Alternatives WM3-6 230DB Modbus Utility EEM Meter Setting Software Utility
Free Aus Post Shipping for $300 Spend$184.00
$217.12 inclGST -
D2425DE, Dual Solid State Relay, Two Pole 15-32VDC Control, 2 x 25A, 24-280VAC Load
Crydom D2425DE, Dual Solid State Relay, Two Pole 15-32VDC Control, 2 x 25A, 24-280VAC Load Features Ratings from 2 x 25A to 2 x 40 Amp @ 24-530 VAC SCR output for heavy industrial loads Zero voltage or instantaneous turn-on outputs UL/CSA/VDE Approved, CE Compliant to EN60950-1 Improved SEMS screw and washer Redesigned housing with anti-rotation barriers AC & DC control types Direct bond copper substrate EMC compliant to Level 3 Direct power lead frame Epoxy free design Spec Crydom Part Number D2425DE Switching Type Zero Crossing (Dual) ROHS Yes (Details) Control Voltage 15-32VDC Load Current 2 x 25 Amp (rms) Surge Capability 250 Amp (peak) Special Feature Dual SSR Mounting Style Panel Mount Load Voltage Range 24-280VAC EMC Compliant Level 3 Termination Style Screw Unit Weight 75g Factory Pack Qty 20 Datasheet Product Datasheet Notifications Please note Changes from Gen 3 to Gen 4 (current) package design here App Notes Why Use SSR's? The inside story Selecting a SSR DC Output SSR's Selecting a Suitable Heatsink Use of Thermal Interface Material How to Verify the Proper Heatsink Effect of Forced Air Cooling Fuse Protection of SSR's Overvoltage Protection "P" Option MOV SSR Reliability Whitepaper 3 Phase Motors and Heating Applications 3 Phase Motor Reversing How to test a SSR SSR Precautions SSR Life Expectancy MTBF ROHS & Reach Statement Heatsink SSR and Heatsink Assemblies
$151.00
$178.18 inclGST -
IKD225-20-230VAC, Two Pole 2 x NO Modular Contactor 240VAC 25 Amp, 230VAC/220VDC 40-500Hz Control Voltage, Hum Free
Iskra IKD225-20-230VAC, Two Pole 2 x NO Modular Contactor 240VAC 25 Amp, 230VAC/220VDC 40-500Hz Control Voltage, Hum Free, Can Replace MC-25-24-2NO Features 25 Amp (rms) @ 240VAC DIN Rail Mount Changeover Contact Slim package CE Compliant to IEC 60664 IP20 Specification Fastron Part Number IKD225-20-230VAC 40-500Hz Switching Type 2 x SPST NO Approvals CE Coil Voltage 230/240VAC/220VDC 40-500Hz Load Rating 25 Amp Special Feature Hum Free Mounting Style DIN Rail Mount Load Voltage Range 240VAC 40-500Hz Isolation 4kV Termination Style Screw Unit Weight 295g Factory Pack Qty 20 Datasheet Contactor Datasheet
$35.00
$41.30 inclGST -
IK63-40-230VAC, 4 Pole 4 x SPST NO, Modular Contactor 440VAC 63 Amp, 230VAC/220VDC 40-500Hz Control Voltage, Hum Free
Iskra IK63-40-230VAC, 4 Pole 4 x SPST NO, Modular Contactor 440VAC 63 Amp, 230VAC/220VDC 40-500Hz Control Voltage, Hum Free, Can Replace MC-63-240-4NO Features 63 Amp (rms) @ 440VAC DIN Rail Mount Changeover Contact Slim package CE Compliant to IEC 60664 IP20 Specification Fastron Part Number IK63-40-230VAC Switching Type 4 x SPST NO Approvals CE Coil Voltage 230VAC/220VDC, 40-500Hz Load Current (RMS/DC) 63 Amp (rms) @ 440VAC Special Feature Hum Free Mounting Style DIN Rail Mount Load Voltage Range 440VAC, 40-500Hz Isolation 4kV Termination Style Screw Unit Weight 295g Factory Pack Qty 20 Datasheet Contactor Datasheet
$74.00
$87.32 inclGST -
IK40-40-230VAC, 4 Pole 4 x SPST NO, Modular Contactor 440VAC 40 Amp, 230VAC/220VDC 40-500Hz Control Voltage, Hum Free
Iskra IK40-40-230VAC, 4 Pole 4 x SPST NO, Modular Contactor 440VAC 40 Amp, 230VAC/220VDC Control Voltage, Can Replace MC-40-240-4NO Features 40 Amp (rms) @ 440VAC DIN Rail Mount Changeover Contact Slim package CE Compliant to IEC 60664 IP20 Specification Fastron Part Number IK40-40-230VAC Switching Type 4 x SPST NO Approvals CE Coil Voltage 230VAC/220VDC 40-500Hz Load Current (RMS/DC) 40 Amp (rms) @ 440VAC Special Feature Hum Free Mounting Style DIN Rail Mount Load Voltage Range 440VAC 40-500Hz Isolation 4kV Termination Style Screw Unit Weight 295g Factory Pack Qty 20 Datasheet Contactor Datasheet
$59.00
$69.62 inclGST