Fastron Electronics AMB-A-V7-A-N, AC Voltage Panel Meter, 0-600VAC Input, 110-240VAC Supply, Large 4.1 Digit
Adjustable Zero and Span Setting
Adjustable Display Scaling
Large 4.1 Digit 20.3mm (8 Inch) LED Display
250mS Response Time
PC 94 UL V0
Each unit needs just 96 x 48mm Panel Space
90mm Depth
CE Approved
Specification
Fastron Electronics Part Number
AMB-A-V7-A-N
Transmission Output
N/A
Input
0-600VAC
Over Range
x 1.5
Operating Temperature
0 - 60°C
Supply Voltage
100 - 240VAC
Span Adjustment Range
+/-10%
Zero Adjustment Range
+/-5%
Termination Style
Screw
Display Type
4.1 Digit RED LED
Mounting Style
96 x 48mm Panel Mount
Case Material
PC - UL 94 V0
Weight
320g
Factory Pack Qty
1
Datasheet
Product Datasheet
Application Notes
Panel Meters Blog Articles
Gigavac G64B771, HV Relay, 50kVDC, 10A, SPST-NC, 12VDC Coil, 1,000,000 Cycles, 55kV Isolation, 72" Flying leads
Features
Hermetically Sealed (Patented) rated to 85 Deg C
High Efficiency DC Coils
Gas filled
Small and lightweight
Flexible package for installation
Specification
Gigavac Part Number
G64B771
Main Contact Type
SPST-NC
Auxiliary Contact Type
N/A
Coil Voltage
12VDC
Load Current
10 Amp
Mechanical Life @ 0 Amp
1,000,000 Operations
Nominal Load Voltage
50kV rms
Control Input Terminals
72" Flying Leads
Special Feature
N/A
Mounting Style
Panel Mount (M4)
Peak Voltage
55kVDC
Standards
UL508, NEC 690.11 and 690.12 DC
Termination Style
Screw
Unit Weight
335g
Factory Pack Qty
1
Datasheet
Product Datasheet
Trent 175BF, aR Semiconductor Fuse 690VAC 175Amp I²t Fuse BS88 Style
Features
Equivalent to Mersen 6.9 URGL 36/180 R097167, Bussmann 175FM ETI BS38UQ/83/180A/690V
British Standard Fuse Links Package
Wide Range of I²t
Ratings up to 1000 Amp
Busbar or Standoff Mounting
IEC Standard 60269.1 AND 4
690 V Voltage Rating complying with IEC 33
Applications
Protection of High Powered Semiconductors according to I²t
Short Circuit Protection
DC or AC Motor I²t Protection
Battery Fuse
Specification
Trent Part Number
175BF
Fuse Type
I²t aR Class
Nominal Voltage
690VAC @ 50Hz
I²t Rating
20000 A²/s
Nominal Current (RMS + DC)
175 Amp
Tested Breaking Capacity
200kA @ 690VAC
Dimensions
79.4 x 24 x 110mm
Hole Centers
75.2 x 93.6mm
Mounting Style
Busbar or Panel Mount with Standoff
Operating Temperature Range
-40°C / 125°C
Watt Loss
33.1W
Termination Style
M6
Unit Weight
220g
Factory Pack Qty
10
Datasheet
Product Datasheet
Cross Reference Chart
Schurter 0034.9856 Fuse Kit, 15pcs x 18 types FSF Series
Features
Meets UL and IEC standards
UL Recognized for 250VAC
High breaking capacity of 1.5 kA @ 250VAC
Meets the requirements of IEC 60127-2 for Industrial Medical, Aviation
Applications
Electrical Appliances
POwer Supply Adaptors
Switch Mode Power Supplies
Avionics
In-line protection
Specification
Schurter Part Number
0034.9856 Fuse Kit
Fuse Type
Various FSF Series
Nominal Voltage
250VAC
Nominal Current (AC rms)
2 Amp
Tested Breaking Capacity
1.5kA @250VAC
Dimensions
5 x 20mm
Fuse Holder
Fuse Holders
Mounting Style
Requires fuse holder
Operating Temperature Range
-40°C / 85°C
Unit Weight
350g
Factory Pack Qty
10
Datasheet
Product Datasheet
Fuse Holder
0031-2203 Shock Proof Fuse Holders
Infineon/Siemens BSM600GA120DLC, IGBT Single, 600Amp, 1200V
Features
IGBT for Low Frequency Inverter
Pressure Contact Technology
Electrically insulated base plate
Wide Temperature Range
Medium Switching Speed
2500V Isolation
61mm Base Width
Applications
Frequency Converter
Line rectifying 50/60 Hz
Deep Cycle Applications
Controlled Rectifiers
Softstart AC motor control
Low Frequency Inverter
Drives
Specification
Infineon/Siemens Part Number
BSM600GA120DLC
Vces
1200V
Transistor Configuration
Single IGBT Module
Ic(nom) @ 60 Deg C
600 Amp
Package Size
W:61.4mm L:106.4mm D:30mm
V(isol)
2.5 kV
Vf @ 25 Deg C
1.8 - 2.3V
Tj(max)
150°C
Td(on) @ 25 Deg C
0.09uS
Td(off) @ 25 Deg C
0.54uS
I(ces) @ 25 Deg C
400nA
Rcc
N/A
Terminals
M6 Screw
Hole Centres
93 x 48mm(M6)
Gate Terminals
Spade (A 2.8 - 0.5mm)
R th(j-c)
0.09°C/W
R th(c-h)
N/A
Weight
500g
Mounting Torque
4 Nm (4 Nm Terminals)
Factory Pack Qty
10
Certification
UL Listed, ROHS
Infineon Headquarters
Germany
Datasheet
Product Datasheet
Alternatives
, Obsolete. Contact Us for Possible Replacement for alternative
SDM630Modbus-MID-V2-CL1 (SDM630-M), DIN Rail Mount kWh Meter, 3 Phase, Class 1, 100 Amp Direct Connect input, w/ 2 x pulse outputs and RS485 Comms, MID Approved
3 x 100 amp Direct Connect
RS 485 communication up to 38,400 bit/s as standard
Optional Mbus Model available
True RMS values of currents and voltages
2 x Pulse Outputs (1 Configurable)
The meter is intended for measuring, and monitoring single-phase or electrical power network. The meter records TRMS value according to the principle of fast sampling of voltage and current signals. A built-in microprocessor calculates measurands (voltage, current, frequency, energy, power to the 30th Harmonic) from the measured signals.
Features :
Accuracy class 1
Measurement of Active and Reactive Power
Modbus RTU communication up to 38,400 bit/s communication
Pulse output as standard
Graphic LCD with illumination
Specification
Eastron Europe Part Number
SDM630Modbus-MID-V2-CL1 (SDM630-M)
Functions
Three Phase Energy Meter
Supply Voltage
NA
Nominal Measurement Range
415V L-L 230V L-N, 100 Amp
Maximum Measurement Range
480V L-L 230V L-N, 100 Amp
Nominal Current Input
Direct connect 3 x 100 Amp
Pulse Output
2 x Passive, (1 x Configurable 60/100/200ms)
Tariff Input
N/A
Accuracy
Class 1 (I,U,F,kW,kWh) Class 2 (Reactive)
Mounting
Din Rail
Real Time Clock
1min/month (30ppm)
Internal Memory
N/A
Dimensions
72mm x 100mm x 66mm (4 modules wide)
Isolation
4kV
RS485
2400-38400 b/s (400ms Response Time)
Weight
150g
Certification
EN 61010-1 Installation Category III
Factory Pack Qty
1
Safety
IP51(Indoor)
Enclosure Material
Noryl with fire protection to UL94-V-O. Self extinguishing
Enclosure Size
DIN 42880 4 Modules
Operating Temperature
-20 →+70 °C
Documents
Product Datasheet
User Manual
Modbus Protocol
Alternatives
WM3-6 230DB
Modbus Utility
EEM Meter Setting Software Utility
Eastron Europe SDM120Modbus, DIN Rail Mount kWh Meter, Single Phase, Class 1/Class B, 45Amp Direct Connect, w/ 2 x pulse outputs and RS485 Comms, MID Approved
45 amp Direct Connect
1 x Configurable Pule Output (via Modbus)
1 x Fixed Pulse Output (1000imp/kwh)
RS 485 communication up to 38,400 bit/s as standard
Optional Mbus Model available
True RMS values of currents and voltages
The meter is intended for measuring, and monitoring single-phase or electrical power network. The meter records TRMS value according to the principle of fast sampling of voltage and current signals. A built-in microprocessor calculates measurands (voltage, current, frequency, energy, power to the 30th Harmonic) from the measured signals.
Features :
Accuracy class1
Measurement of Active and Reactive Power
Modbus RTU communication up to 38,400 bit/s communication
Pulse output as standard
Graphic LCD with illumination
Specification
Eastron Europe Part Number
SDM120Modbus-MID
Functions
Single Phase Energy Meter
Supply Voltage
N/A
Nominal Measurement Range
230V L-L 230V L-N, 45 Amp
Maximum Measurement Range
276V L-L 230V L-N, 45 Amp
Nominal Current Input
Direct connect 45 Amp
Pulse Output
1 x 1000imp/kwh, 1 x Configurable via Modbus 60/100(default)/200ms
Accuracy
Class 1/Class B (I,U,F,kW,kWh) Class 2 (Reactive)
Mounting
Din Rail
Real Time Clock
1min/month (30ppm)
Internal Memory
N/A
Dimensions
24mm x 100mm x 66mm (1 module wide)
Isolation
4kV
RS485
2400-38400 b/s
Weight
150g
Certification
EN 61010-1 Installation Category III
Factory Pack Qty
1
Enclosure Material
Noryl with fire protection to UL94-V-O. Self extinguishing
Enclosure Size
DIN 42880 6 Modules
Operating Temperature
-20 →+70 °C
Datasheet
Product Datasheet
User Manual
Modbus Protocol
Setup Video
Alternatives
WM3-6 230DB
Modbus Utility
EEM Meter Setting Software Utility
Trent 80BF Series 690V 80Amp Semiconductor I²t Fuse BS88 Style, aR
Features
Equivalent to Mersen 6.9 URGL 36/110 P097165
British Standard Fuse Links Package
Wide Range of I²t
Ratings up to 1000 Amp
Busbar or Standoff Mounting
IEC Standard 60269.1 AND 4
690 V Voltage Rating complying with IEC 33
Applications
Protection of High Powered Semiconductors according to I²t
Short Circuit Protection
DC or AC Motor I²t Protection
Battery Fuse
Specification
Trent Part Number
80BF
Fuse Type
I²t aR Class
Nominal Voltage
690VAC @ 50Hz
I²t Rating (IP < 30IN)
4000 A²/s
Nominal Current (RMS + DC)
100 Amp
Tested Breaking Capacity
200kA @ 690VAC
Dimensions
79.4 x 24 x 110mm
Hole Centers
75.2 x 93.6mm
Mounting Style
Busbar or Panel Mount with Standoff
Operating Temperature Range
-40°C / 125°C
Watt Loss
50W
Termination Style
M6
Unit Weight
220g
Factory Pack Qty
10
Datasheet
Product Datasheet
Cross Reference Chart
Fastron FRT8-M2/W240, Multifunction Timer 12-240 V AC/DC, 0.1s - 10 Days, 2 x SPDT 16 Amp C/O Contacts Replaces Elko CRM-91H,CRM-93H,CRM-9S
Features :
Multi-range (0.1s - 10days)
Multi-voltage 12 →240 V AC/DC
LED status indicator
Possibility of external load connection in parallel to the control input
Suitable replacement to Elko CRM-91H,CRM-93H,CRM-9S
Multifunction Timers Includes The Following :
A: A pulse after power-on or after the rising edge of trigger pulse S.
B: Delay after power-on or after the rising edge of trigger pulse S.
C: A pulse after power-on or after the rising edge of trigger pulse S. Retriggerable.
D: Delay after power-on or after the rising edge of trigger pulse S. Retriggerable.
E: The first edge of trigger pulse S turns relay on while the second edge starts counting down till relay off. Additional trigger S before the process is finished prolongs the on-state.
F: Each rising edge of trigger S appends additional period T to the time of on-state.
G: Pulsating operating with a starting pulse or pause which depends on the state of trigger S at power-on.
H: Bistable operating. Each rising edge of trigger S swaps the relay into the opposite state.
I: Prolonged pulse after power-on. The presence of trigger S temporarily stops counting.
J: Prolonged pause after power-on. The presence of trigger S temporarily stops counting.
Specification
Fastron Part Number
FRT 8-M2/W240
Function
Multifunction Timer
Nominal Voltage
12 → 240 V AC/DC
Digital Output
2 x C/O (SPDT) (Changeover -Single Pole), 250VAC/DC @ 16 Amp
Min Breaking Current
10mA/12VDC
Timing Ranges
Selectable 1s - 10 Days
Minimum Pulse Duration
30ms/100ms with load
Repeatability
0.5%
Reset Time
120ms
Isolation
4kV
Repetition Accuracy
0.5%
Threshold Adjustment Range
10 → 100 % of the range
Termination Style
Screw
Weight
80g
Factory Pack Qty
1
Certification
CE, RoHS
Over Voltage Category
3 in accordance with IEC/EN 60664-1
Pollution Degree
2 in accordance with IEC/EN 61131-2
Protection rating
IP40 (Front), IP20 (Rear)
Mechanical Resistance
Immunity to vibrations IEC/EN 60068-2-6, test Fc
Immunity to shock IEC/EN 60068-2-27, test Ea
Resistance to HF Interference
Immunity to radiated electrostatic fields IEC/EN 61000-4-3 Immunity to fast transients (burst immunity) IEC/EN 61000-4-4, level 3 Immunity to shock waves IEC/EN 61000-4-5 Radio frequency in common mode IEC/EN 61000-4-6, level 3 Voltage dips and breaks (AC) IEC/EN 61000-4-11 Immunity to damped oscillatory waves IEC/EN 61000-4-12
Conducted and radiated emissions
Class B (*) in accordance with EN 55022, EN 55011 (CISPR22, CISPR11) group 1 (*) Except configuration (88 970 1.1 or 88 970 1.2) + (88 970 250 or 88 970 270) + 88 970 241 class A (class B in a metal enclosure)
Operating Temperature
-20 →+70 °C except CB and XB versions in VDC : -30 →+70 °C (+40 °C in a non-ventilated enclosure) in accordance with IEC/EN 60068-2-1 and IEC/EN 60068-22
Datasheet
Product Datasheet
Fastron Monitoring/Time Relays Catalogue
For items in our catalogue which are not listed online please Contact Us for Possible Replacement
LEM ART-B22-D70-SP3 + AI-P1A, 3 Phase Rogowski Coils & Universal Multi Range Integrator with Signal Conditioner
The universal Rogowski coil integrator AI-P1A complements LEM’s flexible clip-around coil ART and ARU range. The design is based on digital processing to give combined dynamic range, accuracy and versatility of use. It offers a wide range of output signals both RMS and instantaneous. AI-P1A is DIN rail mounted and can be stacked for multiphase application without spacing thanks to its low power dissipation.
Input signal
Accuracy Class 1 (IEC 61869-2) [1].
Linearity error ≤ 0.10 %. Protection degree IP2X.
35 mm DIN rail mounted.
Push-in terminals.
1 Amp instantaneous output.
6 selectable sensitivities depending on Rogowski coil: 22.5, 70, 80, 85, 100, 120 mV/kA at 50 Hz.
12 selectable ranges: 100, 200, 300, 400, 500, 600, 800, 1000, 1500, 2000, 4000, 5000 A.
Ambient operating temperature −25...+70 °C.
Advantages
Compact design for DIN rail assembly
High accuracy Class 1 (IEC 61869-2)
Setup by user via Select / Edit buttons
Clear status indication via bi-color led
Applications
MV/LV substations on LV side: Transformer Condition Monitoring
Power metering: current measurement for active power calculation
Building sub-metering: energy efficiency monitoring, consumption analysis and cost allocation
Power quality monitoring: electrical loads and distribution system equipment
Fault Detection, Isolation and Repair (FDIR): isolate the site of the fault
Remote Terminal Units (RTU)
Phasor Measurement Units (PMU)
Standards
IEC 61010-1: 2010
UL
EMC: IEC 61326-1:2012
Included Options
Cross Power Plug-in: side contacts to stack up to 3 Integrator modules and use only one power supply.
Specification
LEM Part Number
AI-P1A + ART-B22-D70 (3Pcs)
Function
3 Phase AC Current Measurement
Measuring Range
Selectable 5000,4000,2000,1500,1000,800,600,500,400,300,200,100Amp
Sensitivity
Selectable 22.5,70,80,85,100,120mV/kA @ 50 Hz
Output
1 Amp output
Frequency Measuring Range
50-1500Hz (15th Harmonic)
Operating Voltage
10-32VDC
Accuracy
1% from 25 to 5000 Amp
Current Consumption
100mA (max)
Dimensions
100mm x 78mm x 15mm (Integrator), 7cm Diameter (Coils)
Mounting
Din Rail Mount
Integrator to Coil cable
3M Twisted and Screened
Integrator to Meter cable
User Supplied Shielded cable 1.5mm sqr, up to 6m long
Operating Temperature
-25°C - 70°C
Storage Temperature
-45°C to 80°C
Isolation (50Hz, 1 min)
1.5kV
True RMS Response Time
160-190ms
Termination Style
Push-in for 1.5mm sqr wire
Weight
58g
Factory Pack Qty
1
Certifications
UL, ROHS
Datasheet
AI-P1A Datasheet
ART Series Datasheet
Applicaton Notes
User Notice
1) The Rogowski coil can measure any primary current as there is no saturation effect.
2) Not tested given that in the worst case (load = 0 Ohm i.e. short circuit on the output) the peak dissipated power remains low (< 2 Watts)
3) Frequency bandwidth and phase shift modelling schematic can be provided on request.
4) Referring to the main phase offset of 90 ° (a Rogowski coil is a derivative current transducer)
5) Considering a primary conductor of at least ⌀ 15 mm, perpendicular and in contact with the Rogowski coil.
6) Considering an external conductor of at least ⌀ 15 mm the same current level than internal conductor, perpendicular and in contact with the Rogowski coil.
Fastron FDV-300-V05-12, DC Voltage Transducer, Din Rail Mount, 0-300VDC, 0-5V output, 12VDC Supply Voltage, 150mS Response
150mS Response Time
PC 94 UL V0
Input signals can be converted to insulated 5V DC output (for voltage output type)
Each unit needs just 22.5 x 114 mm depth DIN Rail cabinet space
Specification
Fastron Part Number
FDV-300-V05-12
Analogue Output
0-5V
Input
0 - 300VDC
Measurement Range
120%
Overload
150% Continuous
Operating Temperature
-30 - 70°C
Operating Voltage
12VDC +/-15%
Voltage Isolation (1 min)
2.5kV
Accuracy
1%
Response Time
150mS
Termination Style
Screw
Mounting Style
DIN Rail Mount
Safety
CE, UL94V0
Weight
170g
Factory Pack Qty
1
Datasheet
Product Datasheet