DVL 750 UI, Digital Voltage Transducer 750V Input, 4-20mA output, +/- 15V…24VDC, 8.5kV Isolation
LEM DVL 750 UI, Digital Voltage Transducer 750V Input, 4-20mA output, +/- 15V…24VDC, 8.5kV Isolation Features Bandwidth DC to 14kHz Multi Range through pin selection Closed loop transducer using Hall effect Compact and versatile Panel Mount Insulated plastic case recognized according to UL 94-V0 Advantages Very good linearity High accuracy Low temperature drift Wide frequency bandwidth Very low insertion losses High immunity to external interference Voltage overload capability Low power consumption Applications Railway substation or locomotive AC variable speed drives and servo motor drives Static converters for DC motor drives Battery supplied applications Uninterruptible Power Supplies (UPS) Switched Mode Power Supplies (SMPS) Power supplies for welding applications Water Treatment Electronics Specification LEM Part Number DVL 750 UI Technology Closed Loop Hall Effect Aperture No Aperture ROHS Yes Supply Voltage +/-15..24 VDC Bipolar, Isolated Primary Nominal Voltage (RMS + DC) +/- 750V Measurement Range +/- 1125V Output 4 - 20mA Isolation 8.5 kV Bandwidth DC-14 kHz Mounting Style Panel Mount Operating Temperature Range -40°C / 70°C Accuracy 1% Termination Style M5 Screw Unit Weight 270g Factory Pack Quantity 4 Datasheet Product Datasheet Application Notes LEM Applications Manual 3rd Edition
$661.00
$779.98 inclGST -
FTCK Series Type K Thermocouples MIMS Class A, Standard Sizes and Lengths 3mm or 5mm Shaft, Braided SS/Fibreglass/Teflon Tail, 304 Stainless Steel Sheath, CE ANSI ROHS Approved, -20 to 700 Deg C
Fastron FTCK Series Type K Thermocouples MIMS Class A, Standard Sizes and Lengths 3mm or 5mm Shaft, Braided SS/Fibreglass/Teflon Tail, 304 Stainless Steel Sheath, CE ANSI ROHS Approved, -20 to 800 Deg C Class A Accuracy CE, ANSI, ROHS Approved Kink proof Fiberglass Reinforced SS Braided Cable Low Long Term Drift Rated for -20 to 800 Deg C Max Spring Cable Connection 50 - 500mm or custom Sheath Thickness 3/5/9mm or custom MIMS Recommended to use BSP Fitting for mounting Specification Fastron Part Number FTCK Series Sensor Type Type K Thermocouple No of Wires 2 Probe Length 50-500mm or custom Sheath Thickness 3/6/9mm or custom Sheath Material SS 304 Stainless Steel Aprovals CE, ANSI, ROHS Accuracy Class A Cable length 3 Meters (Standard) or custom Cable Type Teflon/Fibreglass/Braided Stainless Steel Temperature Range -20 to 800 Deg C Special Feature Spring Cable Strain Relief Mounting Style BSP Bayonet or Flange Fitting Recommended Weight 300-500g Factory Pack Qty 1 Datasheet Type K Datasheet Type K 100mm Datasheet Type K 50mm Datasheet
$56.00 - $76.00
-
PSDH70/16, 3 Phase Half Controlled Bridge, 70 Amp, 1600V, Spade Connections
Powersem PSDH70/16, 3 Phase Half Controlled Bridge, 70 Amp, 1600V, Spade Connections, Can Replace Semikron SKCH28, SKCH43 or SI S3PHBD70 series Features Half Controlled Braking/Freewheeling Diode Package with DCB ceramic base plate Isolation voltage 3000 V∼ Planar glass passivated chips Low forward voltage drop Leads suitable for PC board soldering UL registered, E 148688 Applications Lift Motor Control with Braking Heat and temperature control for industrial furnaces and chemical processes Lighting control Motor control Power converter Advantages Easy to mount with two screws Space and weight savings Improved temperature and power cycling capability High power density Specification Powersem Part Number PSFD70/16 AC Line voltage 533V Device Configuration Three Phase Half Controlled Rectifier Bridge DC Output @ 85 Deg C 70 Amp Package Size W:29mm L:68mm D:17mm Itsm 550 A VF(to) 0.85V Tj(max) 125°C rF 11mΩ Terminals Faston (6.3mm) Hole Centres 68mm (M5) Gate Terminals M3 (1.5Nm) R th(j-c) 0.9°C/W R th(c-h) 0.20°C/W Weight 100g Isolation 3kV Factory Pack Qty 10 Certification UL Listed Powersem Headquarters Germany Datasheet Product Datasheet Alternatives See PSDF70/16 for alternative with freewheeling diode
$75.49
$89.08 inclGST -
F930 Series Programmable True RMS AC or DC Versions, Various Ranges 100mA - 250 Amp AC/DC Current Transducer with 4 Digit LED Display, Selectable Process Level Outputs, Optional RS485 and/or 2 x Relay Outputs
F930 Series Programmable True RMS AC or DC Versions, Various Ranges 100mA - 250 Amp AC/DC Current Transducer with 4 Digit LED Display, Selectable Process Level Outputs, Optional RS485 and/or 2 x Relay Outputs Features Following on from the success of F916,F921,F920,F922,,F923 Series AC/DC Current Transducers & Trip Modules. We designed a new microcontroller based transducer to take advantage of modern digital methods and the latest generation of LEM ASIC based current sensors. Our transducer can adjust zero, span, and optional Alarms, including dual flasher outputs in both Traditional Relay or Solid State types. Ultimately, there will also be a Power Transducer with one or two analogue outputs & RS485 Comms for import export control applications. Our Transducers are widely used in rail and several other industrial control and automation industries. Datasheet Product Datasheet
$375.00
$442.50 inclGST -
LF 2010-S, C/L Hall Effect Sensor, 2000 Amp, +/-400mA Output, 60.5mm Aperture, +/-15..24V Supply, Panel Mount
LEM LF 2010-S, C/L Hall Effect Sensor, 2000 Amp, +/-400mA Output, 60.5mm Aperture, +/-15..24V Supply, Panel Mount Features Bipolar and insulated current measurement up tp 2700 Amp Current output Bandwidth DC to 100kHz Closed loop (compensated) current transducer Panel mounting Insulated plastic case recognized according to UL 94-V0 Advantages Very good linearity High accuracy Low offset drift over temperature Wide frequency bandwidth Very low insertion losses High immunity to external interference Current overload capability Low power consumption Applications Windmill Inverters Test and Measurement Substations AC variable speed drives and servo motor drives Static converters for DC motor drives Battery supplied applications Uninterruptible Power Supplies (UPS) Switched Mode Power Supplies (SMPS) Power supplies for welding applications Application Domain Industrial Standards EN 50178:1997 IEC61010-1:2010 UL 508:2010 Specification LEM Part Number LF 2010-S Technology Closed Loop Hall Effect Aperture ø60.5mm ROHS Yes Supply Voltage +/- 15 VDC to +/- 24 VDC Bipolar, Isolated Load Current (RMS + DC) 2000 Amp Measurement Range +/- 3000 Amp Output 400 mA Isolation 6 kV Bandwidth DC-150 kHz Mounting Style Panel Mount Operating Temperature Range -10°C / 85°C Accuracy 0.2% Termination Style Molex 6410 Unit Weight 503g Factory Pack Quantity 9 Datasheet Product Datasheet Application Notes LEM Applications Manual 3rd Edition
$437.78
$516.58 inclGST -
MTC400-36-415F3D, Dual Thyristor Module, 400 Amp, 3600V, 60mm package
MTC400-36-415F3D, Dual Thyristor Module, 400 Amp, 3600V, 60mm package Features Thyristor for line frequency Pressure Contact Technology Electrically insulated base plate Industrial standard package Long-term stability 3600V Isolation 50mm Base Width Applications Power Converter Line rectifying 50/60 Hz Deep Cycle Applications Controlled Rectifiers Softstart AC motor control AC power control Lighting and temperature control Specification Techsem Part Number MTC400-36-415F3D Vrrm 3600V Diode Configuration Dual Thyristor Module IF(av) @ 85 Deg C 400 Amp Package Size W:60mm L:115mm D:52mm Itsm 12.5 kA VF(to) 0.98V Tj(max) 125°C rF 0.88mΩ I(gt) @ 25 Deg C 30-200mA Terminals M10 Screw Hole Centres 112mm x 48mm(M6) Gate Terminals Spade (A 2.8 - 0.8 DIN 46244) R th(j-c) 0.054°C/W R th(c-h) 0.024°C/W Weight 1500g Mounting Torque 5 Nm (12 Nm Terminals) Factory Pack Qty 8 Certification UL Listed, ROHS Techsem Headquarters China Datasheet Product Datasheet
$645.00
$761.10 inclGST -
CT 150/5 Class 0.5 3.75VA 62/30 (40) Current Transformer
Rishabh CT 150/5 Class 0.5 3.75VA 62/30 (40) Series Current Transformer Features DIN Rail Mounting Clip Included Built In Sealable Terminal Covers Mounting Feet Supplied Narrow Width (45mm) Self Powered Rated System Voltage 0.72/3kV IEC185, BS 7626, BSEN 60044-1 and IEC 60044-1 Applications Metering Equipment Energy Monitoring AC Power Control Systems Power Factor Correction Power Quality Measurements Specification Rishabh Part Number CT 150/5 Class 0.5 3.75VA 62/30 (40) Technology AC Current Transformer Ratio 150/5 Aperture Size ⌀ 30mm or 26x10mm Busbar VA Rating 3.75VA Accuracy Class Class 0.5 Output 5 Amp AC (+20%) Isolation 3kV (AC, 50Hz, 1 min) Bandwidth 50-60Hz Mounting Style Panel Mount/Din Rail Mount Operating Temperature Range -30°C / 85°C Continuous Current (max) 150Amp x 1.2 Termination Style Screw Unit Weight 300g Factory Pack Qty 9 Datasheet Product Datasheet
$38.00
$44.84 inclGST -
CT 60/5 Class 0.5 1.5VA 50/21 (50) Current Transformer
Rishabh CT 60/5 Class 0.5 1.5VA 50/21 (50) Series Current Transformer Features DIN Rail Mounting Clip Included Built In Sealable Terminal Covers Mounting Feet Supplied Narrow Width (45mm) Self Powered Rated System Voltage 0.72/3kV IEC185, BS 7626, BSEN 60044-1 and IEC 60044-1 Applications Metering Equipment Energy Monitoring AC Power Control Systems Power Factor Correction Power Quality Measurements Specification Rishabh Part Number CT 60/5 Class 0.5 1.5VA 50/21 (50) Technology AC Current Transformer Ratio 6/5 Aperture Size ⌀ 21mm or 20x10mm Busbar VA Rating 1.5VA Accuracy Class Class 0.5 Output 5 Amp AC (+20%) Isolation 3kV (AC, 50Hz, 1 min) Bandwidth 50-60Hz Mounting Style Panel Mount/Din Rail Mount Operating Temperature Range -30°C / 85°C Continuous Current (max) 60Amp x 1.2 Termination Style Screw Unit Weight 300g Factory Pack Qty 9 Datasheet Product Datasheet
$36.00
$42.48 inclGST -
FESCT-19-050-0.333V, 50Amp measurement Split Core CT's, Class 1, w/1M Flying leads, 19x19mm Aperture
Fastron Electronics FESCT-19-050-0.333V, 50Amp measurement Split Core CT's, w/1M Flying leads, 19x19mm Aperture, Class 1 Features Quick Release Split Core System 1m Flying Leads Mounting Feet Supplied Self Powered Rated System Voltage 0.60/3kV Applications US Based Metering Equipment Energy Monitoring AC Power Control Systems Power Factor Correction Power Quality Measurements Specification Fastron Part Number FESSCT-19-050-0.333V Technology Split Core AC Current Transformer Ratio 50/0.333V Aperture Size 19 x 19mm VA Rating N/A Accuracy Class Class 1 Output 0.333VAC (+20%) Isolation 3kV (AC, 50Hz, 1 min) Bandwidth 50-60Hz Mounting Style Cable Mount/Busbar Mount Operating Temperature Range -15°C / 55°C Continuous Current (max) 50Amp x 1.2 Termination Style 1M Twisted Pair 0.34mm^2 Unit Weight 350g Factory Pack Qty 9 Datasheet Product Datasheet Application Notes Installation Guide
$69.00
$81.42 inclGST -
DSTO-C14-5F-R-N-N-H, Distribution Unit with IEC Inlet C14 to 5 x F/C13 Outlet, 240VAC @ 10 Amp with Rocker Switch, Rear Mounted with plastic hooks, MOQ = 10pcs
Trent DSTO-C14-5F-R-N-N-H, Distribution Unit with IEC Inlet C14 to 5 x F/C13 Outlet, 240VAC @ 10 Amp with Rocker Switch, Rear Mounted with plastic hooks, MOQ = 10pcs (If not in stock) Features 1 x C14 in 5 x F/C13 out, Ganged Distribution Outlet C14 Socket acc to IEC 60320-1 70 °C pin Temperature Rocker Switch Protected Suitable for use in equipment according to IEC/UL 60950 OTHER SIZES CAN BE MADE TO ORDER Characteristics UL 60320-1, CSA C22.2 no. 60320-1 (for hot conditions) pin-temperature 70 °C, 10A, Protection Class I Types for enhanced glow wire test requirements acc. IEC 60695-2- 12 and -13 for the use in unattended household equipment acc. IEC 60335-1 Specification Trent Part Number DSTO-C14-5F-R-N-N-H Rated Voltage 250V Rated Current 10A No of Outlets 5 Operating Temperature -25°C to 120°C Filter Type N/A Overload Protection YES Line Switch Rocker Switch - 10 Amp (red Illumination) Mounting Rear Mounted with Plastic Hooks Material Powder Coated Metal black Termination Style 1 x C14 Inlet, 5 x F/C13 Outlet Weight 2000g Factory Pack Qty 1 Protection Class From front side IP30 acc. to IEC 60529 Isolation 2kV (L-N, L/N-E) VDE/CE/ROHS YES Datasheet Product Datasheet
$95.00
$112.10 inclGST -
GA5-A-V7-D-N, 96x48mm 5 DIGIT Digital Ammeter 0-600VAC input, 22-60VAC/DC Supply, Large 5 Digit
Fastron Electronics GA5-A-V7-D-N, 96x48mm 5 DIGIT Digital Ammeter 0-600VAC input, 22-60VAC/DC Supply, Large 5 Digit Adjustable Zero and Span Setting Adjustable Display Scaling Large 5 Digit 20.3mm (8 Inch) LED Display 250mS Response Time PC 94 UL V0 Input signals can be converted to insulated 4 to 20 mA DC output (for direct current output type) Each unit needs just 96 x 48mm Panel Space 90mm Depth Specification Fastron Electronics Part Number GA5-A-V7-D-N Conditioner Output N/A Input 4-20mA Over Range x 1.5 Operating Temperature 0 - 60°C Load Voltage 22-60VAC/DC Span Adjustment Range +/-10% Zero Adjustment Range +/-5% Termination Style Screw Mounting Style 96 x 48mm Panel Mount (60mm depth) Case Material PC - UL 94 V0 Weight 320g Factory Pack Qty 1 Datasheet Product Datasheet Application Notes Panel Meters Blog Articles
$195.00
$230.10 inclGST -
FGM6S-3P-630H 630A, 3 Pole Moulded Case Circuit Breaker (MCCB) Thermal, Adjustable Type ICS=75kA 630 Amp, 400/690VAC
Trent FGM6S-3P-630H 630A, 3 Pole Moulded Case Circuit Breaker (MCCB) Thermal, Adjustable Type 75kA 630 Amp, 400/690VAC Miniature Circuit Breakers are used for over-current (overload and short-circuit) protection of installations and devices, and as a disconnector in case of electric shock Features : Disconnect 75kA Short Circuit Rating @400VAC Suitable for Main Incoming Breaker Standards : IEC/EN 60898,60947-3 IP20 (IP40 Installed) IEC 61008 AS/NZ 61009-1 Specification Trent Part Number FGM6S-3P-630H 630A Functions MCCB Nominal Voltage 400/690VAC @ 50/60Hz Nominal Current Range 630 Amps RMS Trip Delay Time < 50ms Rated Impulse Voltage 8kV Operating Temperature -25 to 50 Deg C Mechanical Operations 20,000 Ops Insulation Voltage 800V Short Circuit Current 75kA Approvals KEMA EUR, CE Standards IEC/EN 60898-1,IEC/EN 60947-3, IP20 (IP40 Installed) IEC 61008 ; AS/NZ 61009-1 Weight 6.9kg Enclosure Material UL94 Factory Pack Qty 1 Datasheet Product Datasheet
$969.00
$1,143.42 inclGST