Crydom PMP2490WP, Phase/Burst control, 240VAC, 90 Amp, Selectable 0-5V,0-10V,4-20mA input, w/Overvoltage Protection
Features
Selectable Proportional Phase or Burst Control Input
Ratings from 25A to 90 Amp @ 170-600 VAC
SCR output for heavy industrial loads
Zero voltage or Instantaneous turn-on outputs
UL/CE/ROHS Compliant
Direct bond copper substrate
Direct power lead frame
Epoxy free design
Spec
Crydom Part Number
PMP2490WP
Switching Type
Phase Angle or Burst (Selectable)
ROHS/CE/UL
Yes
Control Voltage
0 - 10V/0 - 5V/4 - 20mA Proportional Input (Selectable)
Note Requires DC Power Supply for 0-5V/0-10V input modes
Load Current
90 Amp (rms)
Surge Capability
1290Amp (peak)
Special Feature
Proportional Controller + SSR
Mounting Style
Panel Mount
Load Voltage Range
170-280VAC
Dielectric Strength
4kV
Termination Style
Terminal Plug
Unit Weight
160g
Factory Pack Qty
20
Datasheet
Product Datasheet
Notifications
Please note Changes from Gen 3 to Gen 4 (current) package design here
Equivalent
FTY220D80P
Contact Us for Possible Replacement
PMP24 Installation/Wiring Guide
Heatsink
SSR and Heatsink Assemblies
App Notes
Why Use SSR's?
The inside story
Selecting a SSR
DC Output SSR's
Selecting a Suitable Heatsink
Use of Thermal Interface Material
How to Verify the Proper Heatsink
Effect of Forced Air Cooling
Fuse Protection of SSR's
Overvoltage Protection "P" Option MOV
SSR Reliability Whitepaper
3 Phase Motors and Heating Applications
3 Phase Motor Reversing
How to test a SSR
SSR Precautions
SSR Life Expectancy MTBF
ROHS & Reach Statement
LEM AI-P1A M2 Accessory Kit, Multi Stacking Connector for AI-P1A Integrator, LEM Part# 90.T8.98.001.0
Application
Cross Power Plug-in: side contacts to stack up to 3 Integrator modules and use only one power supply.
Note: Included in 3pcs coil and integrator package
Application Notes
User Notice
1) The Rogowski coil can measure any primary current as there is no saturation effect.
2) Not tested given that in the worst case (load = 0 Ohm i.e. short circuit on the output) the peak dissipated power remains low (< 2 Watts)
3) Frequency bandwidth and phase shift modelling schematic can be provided on request.
4) Referring to the main phase offset of 90 ° (a Rogowski coil is a derivative current transducer)
5) Considering a primary conductor of at least ⌀ 15 mm, perpendicular and in contact with the Rogowski coil.
6) Considering an external conductor of at least ⌀ 15 mm the same current level than internal conductor, perpendicular and in contact with the Rogowski coil.
PV10-30A1000VDCgPV, GpV Solar Fuse 30Amp, 1000VDC @ 10kA, UL2579, IEC 60269, GB13539
Features
Meets the new UL and IEC photovoltaic standards
UL Recognized for 1000 VDC
High breaking capacity of 10 kA @ 1000 VDC
Low min. interrupting rating of 1.35 x In
Meets the requirements of IEC 61730-2 for PV module safety
Applications
All photovoltaic applications
Inverters
Battery charge controllers
In-line protection
String fuses
Specification
Vicfuse Part Number
8020.2053
Fuse Type
I²t GpV Class Fast Blow
Nominal Voltage
1000VDC, 275VAC
I²t Rating (Pre-Arcing)
3150 A²/s
Nominal Current (DC)
30 Amp
Tested Breaking Capacity
10kA @1000VDC
Dimensions
10.3 x 38mm
Fuse Holder
FSO Fuse Holders, VCB10-30
Mounting Style
Requires fuse holder
Operating Temperature Range
-40°C / 125°C
Watt Loss
1.8W
DC Breaking Capacity
10kA
Unit Weight
8g
Factory Pack Qty
10
Datasheet
Product Datasheet
Compatible Fuse Holder
FSO Fuse Holders
VCB10-30
Fastron FTM1-A40-V4-W0, Single Phase, Phase Angle/Burst Controller for Primary Control of Transformer (Phase Angle mode only), Voltage/Current/Power Limit Modes, For Single Phase Loads, 400VAC, 32 Amps @ 50 Deg C, Modbus RTU
Features
Phase Angle, Distributed Burst, and Time Proportional Burst Control Functions
Made in China, Low cost
Single Phase, Angle/Burst Controller
4-20mA/0-10V/0-5V input Proportional Control
Phase Angle or Burst switching
Digital Display and Controls
Modbus RTU
Applications
Electrical Ovens, Kilns, or Furnaces
HVAC Heaters
Controlled Power Applications
Electric Boilers
Brewery Heating
Industrial Light Dimming
Suitable for HVAC or Industrial Environments
Specification
Fastron Part Number
FTM1-A40-V4-W0
Rated Operating Temperature
50°C
SCR Configuration
3 Phase AC Switch
Control Voltage
4-20mA/0-10V/0-5V/POT
Load Current
32 Amps Per Phase @ 50 Deg C
Derating
2% per 1 Deg C (approx)
Control Range
0-100%
Alarms
1 x NO Relay Contacts
Special Feature
Internal Fuse, Current Limit, Power Limit
Comms
Modbus RTU
Mounting Style
Panel Mount
Switching Voltage Range
400VAC +/-10%
Supply Voltage
230VAC +/-10%
Dimensions
H:260mm W:94mm D:187mm
Soft Start
N/A
Termination Style
Screw
Unit Weight
2.5kg (4kg Packed)
Factory Pack Qty
1
Technical Docs
User Manual
Brochure
Video for How to Set Current/Voltage/Power limit