Hobut CT105F-250/5-2.5/1 Class 1, 2.5VA 250 Amp, 5 Amp Output, 3 Phase Current Transformer, With Feet Mount
Features
Built In Sealable Terminal Covers
Mounting Feet Supplied
Self Powered
Rated System Voltage 0.72/3kV
IEC185, BS 7626, BSEN 60044-1 and IEC 60044-1
Applications
Metering Equipment
Energy Monitoring
AC Power Control Systems
Power Factor Correction
Power Quality Measurements
Specification
Hobut Part Number
CT105F-250/5-2.5/1
Technology
AC Current Transformer
Ratio
250/5
Aperture Size
21 x 25mm
VA Rating
2.5VA
Accuracy Class
Class 1
Output
5 Amp AC (+20%)
Isolation
3kV (AC, 50Hz, 1 min)
Bandwidth
50-60Hz
Mounting Style
Panel Mount/Din Rail Mount
Operating Temperature Range
-30°C / 85°C
Over Current (max)
250 Amp x 1.2
Termination Style
Screw
Unit Weight
450g
Factory Pack Qty
9
Datasheet
Product Datasheet
Schurter, 4430.2050 TA45-A624F160C0, 2 Pole Thermal Circuit Breaker Rocker Switch for Electrical Appliance, 240VAC/28VDC, 16 Amp
Thermal Circuit Breakers are used for over-current (overload and short-circuit) protection of electrical appliances, and as a disconnector in case of equipment failure/malfunction
Description
Rocker Switch
Thermal circuit breaker
2-pole - Power tools
Manual ON/OFF type
Quick connect terminals 6.3 x 0.8 mm
Features :
< 3mS Trip Delay Time
1 Pole Disconnect
1kA Short Circuit Rating
Suitable for 500VDC Isolation
Applications:
Power Tools
Household Equipment
Power Supplies and Chargers
Industrial Appliances
Standards :
IEC 60934
2 x Ir: 5000 Cycles
500VDC Insulation Resistance
1.5kV (50Hz) Dielectric Strength
Overload @ 6 x Ir Cos φ 0.6 IEC: min 40 trip
@ 1.5 x Ir, cos φ 0.75 Allowable UL / CSA: min. 50 trips
Specification
Schurter Part Number
4430.2050 TA45-A624F160C0
Functions
2 Pole Rocker Switch with 1 Pole Thermal Circuit Breaker
Nominal Voltage
240VAC @ 50Hz or 28VDC
Nominal Current Range
16 Amp RMS
Trip Delay Time
< 3ms
Rated Frequency
50/60 Hz
Operating Temperature
-25 to 55 Deg C
Illumination
Transparent Green
Insulation Resistance
500VDC
Dielectric Strength
1.5kV (50Hz)
Short Circuit Current
1kA
Approvals
UL, CSA
Standards
IEC 6094
Weight
100g
Enclosure Material
UL94
Factory Pack Qty
1
Datasheet
Product Datasheet
Vishay VSKL91/16, Dual Thyristor Module, Common Cathode 91 Amp, 1600V
Features
Thyristor for line frequency
Solder - Solder Bonded
Electrically insulated base plate
Industrial standard package
3600V Isolation
22mm Base Width
Applications
Power Converter
Line rectifying 50/60 Hz
Controlled Rectifiers
Softstart AC motor control
AC power control
Lighting and temperature control
Specification
Vishay Part Number
VSKL91/16
Vrrm
1600V
Diode Configuration
Dual Thyristor Module, Common cathode
IF(av) @ 85 Deg C
95 Amp
Package Size
W:22mm L:93mm D:30mm TO-240AA
Itsm
2.0 kA
VF(to)
1.1V
Tj(max)
125°C
rF
2.38mΩ
I(gt) @ 25 Deg C
150mA
Terminals
M5 Screw
Hole Centres
80mm (M6)
Gate Terminals
Faston A2.8 x 0.8mm
R th(j-c)
0.22°C/W
R th(c-h)
0.1°C/W
Weight
75g
Mounting Torque
4 Nm (3 Nm Terminals)
Factory Pack Qty
10
Certification
UL Listed, ROHS
Country of Origin
India
Datasheet
OLD Product Datasheet
2018 Product Datasheet
Alternatives
See TT92N16K or TT104N14K for Infineon Pressure Contact Alternative, or for IXYS solder bonded Alternative MCC95-16
Fastron Electronics SCT-F36-600-5A, 5 Amp, 600Amp measurement Split Core CT's
Features
Quick Release Split Core System
Cable Mount
5 Amp Output
Self Powered
Rated System Voltage 0.60/3kV
0.9M Flying Leads
Applications
US Based Metering Equipment
Energy Monitoring
AC Power Control Systems
Power Factor Correction
Power Quality Measurements
Specification
Fastron Part Number
SCT-F36-600-5A
Technology
Split Core AC Current Transformer
Ratio
600/5 Amp
Aperture Size
ø 35 mm
VA Rating
N/A
Accuracy Class
Class 1
Output
5 Amp (+20%)
Isolation
3kV (AC, 50Hz, 1 min)
Bandwidth
50-60Hz
Mounting Style
Cable Mount/Busbar Mount
Operating Temperature Range
-15°C / 45°C
Continuous Current (max)
600Amp x 1.2
Termination Style
0.9M Flying leads
Unit Weight
400g
Factory Pack Qty
9
Datasheet
Product Datasheet
Stocked Split Core CT's Listing
Application Notes
Installation Guide
Types of Current Transformers - Blog
Cable Losses and CT's
High Accuracy or High Burden Requirements for CT's
Fastron Electronics SCT-F36-600, 0.333V, 600Amp measurement Split Core CT's Class 1, 35mm Aperture
Features
Quick Release Split Core System
Cable Mount
0.333V Output
Self Powered
Rated System Voltage 0.60/3kV
0.9M Flying Leads
Applications
US Based Metering Equipment
Energy Monitoring
AC Power Control Systems
Power Factor Correction
Power Quality Measurements
Specification
Fastron Part Number
SCT-F36-600
Technology
Split Core AC Current Transformer
Ratio
600/0.333V
Aperture Size
ø 35 mm
VA Rating
N/A
Accuracy Class
Class 1
Output
0.333V (+20%)
Isolation
3kV (AC, 50Hz, 1 min)
Bandwidth
50-60Hz
Mounting Style
Cable Mount/Busbar Mount
Operating Temperature Range
-15°C / 45°C
Continuous Current (max)
600Amp x 1.2
Termination Style
0.9M Flying leads
Unit Weight
400g
Factory Pack Qty
9
Datasheet
Product Datasheet
Stocked Split Core CT's Listing
Application Notes
Installation Guide
Types of Current Transformers - Blog
Cable Losses and CT's
High Accuracy or High Burden Requirements for CT's
Crydom 84140900, Dual Solid State Relay, Two Pole 4-15VDC Control, 2 x 40A, 24-280VAC Load
Features
Ratings from 2 x 25A to 2 x 40 Amp @ 24-530 VAC
SCR output for heavy industrial loads
Zero voltage or instantaneous turn-on outputs
UL/CSA/VDE Approved, CE Compliant to EN60950-1
Improved SEMS screw and washer
Redesigned housing with anti-rotation barriers
AC & DC control types
Direct bond copper substrate
EMC compliant to Level 3
Direct power lead frame
Epoxy free design
Spec
Crydom Part Number
84140900
Switching Type
Zero Crossing (Dual)
ROHS
Yes (Details)
Control Voltage
4-15VDC
Load Current
2 x 40 Amp (rms)
Surge Capability
597 Amp (peak)
Special Feature
Dual SSR
Mounting Style
Panel Mount
Load Voltage Range
24-280VAC
EMC Compliant
Level 3
Termination Style
Screw
Unit Weight
75g
Factory Pack Qty
20
Datasheet
Product Datasheet
Notifications
Please note Changes from Gen 3 to Gen 4 (current) package design here
App Notes
Why Use SSR's?
The inside story
Selecting a SSR
DC Output SSR's
Selecting a Suitable Heatsink
Use of Thermal Interface Material
How to Verify the Proper Heatsink
Effect of Forced Air Cooling
Fuse Protection of SSR's
Overvoltage Protection "P" Option MOV
SSR Reliability Whitepaper
3 Phase Motors and Heating Applications
3 Phase Motor Reversing
How to test a SSR
SSR Precautions
SSR Life Expectancy MTBF
ROHS & Reach Statement
Heatsink
SSR and Heatsink Assemblies
Schurter, 4430.2027 TA45-ABLTM120U3, 2 Pole Pushbutton Switch, Non Latched, 12 AMP, 240VAC, 1 Pole Thermal Overload Protection, Undervoltage Release, Faston Connection, No Illumination, IP40
Thermal Circuit Breakers are used for over-current (overload and short-circuit) protection of electrical appliances, and as a disconnector in case of equipment failure/malfunction
Description
Pushbutton Switch
Undervoltage release
Thermal circuit breaker
2-pole - Power tools
Manual ON/OFF type
Quick connect terminals 6.3 x 0.8 mm
Features :
< 3mS Trip Delay Time
1 Pole Disconnect
1kA Short Circuit Rating
Suitable for 500VDC Isolation
Applications:
Power Tools
Household Equipment
Power Supplies and Chargers
Industrial Appliances
Standards :
IEC 60934
2 x Ir: 5000 Cycles
500VDC Insulation Resistance
1.5kV (50Hz) Dielectric Strength
Overload @ 6 x Ir Cos φ 0.6 IEC: min 40 trip
@ 1.5 x Ir, cos φ 0.75 Allowable UL / CSA: min. 50 trips
Specification
Schurter Part Number
4430.2027 (TA45-ABLTM120U3)
Functions
2 Pole Rocker Switch with 1 Pole Thermal Circuit Breaker and Undervoltage release (230VAC)
Nominal Voltage
240VAC @ 50Hz or 28VDC
Nominal Current Range
12 Amp RMS
Trip Delay Time
< 3ms
Rated Frequency
50/60 Hz
Operating Temperature
-25 to 55 Deg C
Insulation Resistance
500VDC
Illumination
Transparent Green
Dielectric Strength
1.5kV (50Hz)
Short Circuit Current
1kA
Approvals
UL, CSA
Standards
IEC 6094
Weight
100g
Enclosure Material
UL94
Factory Pack Qty
1
Datasheet
Product Datasheet
Schurter 4732.0000, IEC Appliance Inlet Type E(C14)/M, Black, Rewirable for 3 x 1.5m sqr/14AWG Maximum wire size 8.5mm Type
Features
Panel Mount : Snap-in Mounting from Front Side
Appliance Inlet Type E/C14 Male Plug acc to IEC 60320-1
Screw On Mounting
70 °C pin Temperature
Characteristics
UL 60320-1, CSA C22.2 no. 60320-1 (for hot conditions) pin-temperature 120 °C, 10A, Protection Class I
Other Pin versions available on request
Types for enhanced glow wire test requirements acc. IEC 60695-2- 12 and -13 for the use in unattended household equipment acc. IEC 60335-1
Specification
Schurter Part Number
4732.0000
Rated Voltage
250V
Rated Current
10A (CE) 15A (UL/CSA)
Operating Temperature
-25°C to 70°C
Mounting
Wire Screw Mount/Inlet
Material
Thermoplastic, black, UL 94V-0
Termination Style
Type E(C14) Male to Screw Terminal Rewirable
Cable Diameter
8.5mm
Weight
40g
Factory Pack Qty
1
Protection Class
From front side IP30 acc. to IEC 60529
Isolation
2kV
VDE/UL/CSA/CE/ROHS
Yes