Crydom 84140900, Dual Solid State Relay, Two Pole 4-15VDC Control, 2 x 40A, 24-280VAC Load
Features
Ratings from 2 x 25A to 2 x 40 Amp @ 24-530 VAC
SCR output for heavy industrial loads
Zero voltage or instantaneous turn-on outputs
UL/CSA/VDE Approved, CE Compliant to EN60950-1
Improved SEMS screw and washer
Redesigned housing with anti-rotation barriers
AC & DC control types
Direct bond copper substrate
EMC compliant to Level 3
Direct power lead frame
Epoxy free design
Spec
Crydom Part Number
84140900
Switching Type
Zero Crossing (Dual)
ROHS
Yes (Details)
Control Voltage
4-15VDC
Load Current
2 x 40 Amp (rms)
Surge Capability
597 Amp (peak)
Special Feature
Dual SSR
Mounting Style
Panel Mount
Load Voltage Range
24-280VAC
EMC Compliant
Level 3
Termination Style
Screw
Unit Weight
75g
Factory Pack Qty
20
Datasheet
Product Datasheet
Notifications
Please note Changes from Gen 3 to Gen 4 (current) package design here
App Notes
Why Use SSR's?
The inside story
Selecting a SSR
DC Output SSR's
Selecting a Suitable Heatsink
Use of Thermal Interface Material
How to Verify the Proper Heatsink
Effect of Forced Air Cooling
Fuse Protection of SSR's
Overvoltage Protection "P" Option MOV
SSR Reliability Whitepaper
3 Phase Motors and Heating Applications
3 Phase Motor Reversing
How to test a SSR
SSR Precautions
SSR Life Expectancy MTBF
ROHS & Reach Statement
Heatsink
SSR and Heatsink Assemblies
Schurter, 4430.2027 TA45-ABLTM120U3, 2 Pole Pushbutton Switch, Non Latched, 12 AMP, 240VAC, 1 Pole Thermal Overload Protection, Undervoltage Release, Faston Connection, No Illumination, IP40
Thermal Circuit Breakers are used for over-current (overload and short-circuit) protection of electrical appliances, and as a disconnector in case of equipment failure/malfunction
Description
Pushbutton Switch
Undervoltage release
Thermal circuit breaker
2-pole - Power tools
Manual ON/OFF type
Quick connect terminals 6.3 x 0.8 mm
Features :
< 3mS Trip Delay Time
1 Pole Disconnect
1kA Short Circuit Rating
Suitable for 500VDC Isolation
Applications:
Power Tools
Household Equipment
Power Supplies and Chargers
Industrial Appliances
Standards :
IEC 60934
2 x Ir: 5000 Cycles
500VDC Insulation Resistance
1.5kV (50Hz) Dielectric Strength
Overload @ 6 x Ir Cos φ 0.6 IEC: min 40 trip
@ 1.5 x Ir, cos φ 0.75 Allowable UL / CSA: min. 50 trips
Specification
Schurter Part Number
4430.2027 (TA45-ABLTM120U3)
Functions
2 Pole Rocker Switch with 1 Pole Thermal Circuit Breaker and Undervoltage release (230VAC)
Nominal Voltage
240VAC @ 50Hz or 28VDC
Nominal Current Range
12 Amp RMS
Trip Delay Time
< 3ms
Rated Frequency
50/60 Hz
Operating Temperature
-25 to 55 Deg C
Insulation Resistance
500VDC
Illumination
Transparent Green
Dielectric Strength
1.5kV (50Hz)
Short Circuit Current
1kA
Approvals
UL, CSA
Standards
IEC 6094
Weight
100g
Enclosure Material
UL94
Factory Pack Qty
1
Datasheet
Product Datasheet
Schurter 4732.0000, IEC Appliance Inlet Type E(C14)/M, Black, Rewirable for 3 x 1.5m sqr/14AWG Maximum wire size 8.5mm Type
Features
Panel Mount : Snap-in Mounting from Front Side
Appliance Inlet Type E/C14 Male Plug acc to IEC 60320-1
Screw On Mounting
70 °C pin Temperature
Characteristics
UL 60320-1, CSA C22.2 no. 60320-1 (for hot conditions) pin-temperature 120 °C, 10A, Protection Class I
Other Pin versions available on request
Types for enhanced glow wire test requirements acc. IEC 60695-2- 12 and -13 for the use in unattended household equipment acc. IEC 60335-1
Specification
Schurter Part Number
4732.0000
Rated Voltage
250V
Rated Current
10A (CE) 15A (UL/CSA)
Operating Temperature
-25°C to 70°C
Mounting
Wire Screw Mount/Inlet
Material
Thermoplastic, black, UL 94V-0
Termination Style
Type E(C14) Male to Screw Terminal Rewirable
Cable Diameter
8.5mm
Weight
40g
Factory Pack Qty
1
Protection Class
From front side IP30 acc. to IEC 60529
Isolation
2kV
VDE/UL/CSA/CE/ROHS
Yes
Datasheet
Product Datasheet
C100N+100R-Lugged, RC Snubber Network 275VAC, Class X2, 100uF 100 Ohm Lugged for SSR or SCR Terminal Mounting
These snubber neworks are suitable for transient supression in small contactors, bridge rectifers, or solid state relays switching AC or DC Loads. Easily connected or lugged to solid stage relay or power module terminals. See EMC filters, and Metal Oxide Varistors sections for additional supression components.
As and added bonus, these Snubber Networks Improve the Power Factor of switched loads.
Datasheet
Product Datasheet
Trent F150M1000-250, 250 Amp, 1000VAC/590VDC 100kA Semiconductor I²t Fuse Size 70 aR to replace Mersen PC70UD13C250D1A
Features
Square Body Size 70 aR
Wide Range of I²t
Ratings up to 2000 Amp
Fuse Holder Mounted
IEC Standard 60269.1 AND 4
500 V Voltage Rating complying with IEC 33
Applications
Protection of High Powered Semiconductors according to I²t
Short Circuit Protection
DC or AC Motor I²t Protection
Battery Fuse
DC Rectifier Output Fuse
Specification
Trent Part Number
F150M1000-250
Fuse Type
I²t AR Class HRC
Nominal Voltage
1000VAC @ 50Hz, 590VDC
I²t Rating (660V)
Nominal Current (RMS + DC)
250 Amp
Tested Breaking Capacity
100kA @ 1000VAC/590VDC
Dimensions
140 x 45 x 60mm(80mm with microswitch)
Indicator
Tag + Microswitch
Mounting Style
Fuse Holder
Operating Temperature Range
-40°C / 125°C
Watts Dissipation
90W
Termination Style
Size 70 aR (110MM Hole centres)
Unit Weight
400g
Factory Pack Qty
3
Datasheet
Product Datasheet
Crydom HDC200D120, 3.5-32VDC Input, 7-150V, 120Amp DC Output Solid State Relay
Features
Ratings from 100A to 160 Amp @ 7-150VDC
Mosfet output for reliable DC switching
Multiple modules can be wired in parallel for higher currents
UL/CSA/VDE Approved, CE Compliant to EN60950-1
Improved SEMS screw and washer
Redesigned housing with anti-rotation barriers
Direct bond copper substrate
EMC compliant to Level 3
Direct power lead frame
Epoxy free design
Spec
Crydom Part Number
HDC200D120
Switching Type
DC Load
ROHS
Yes (Details)
Control Voltage
3.5-32VDC
Load Current
120 Amp DC
Surge Capability (10ms)
360 Amp DC
Special Feature
High Current Stud Terminals
Mounting Style
Panel Mount
Load Voltage Range
7 - 150VDC
EMC Compliant
Level 3
Termination Style
Screw
Unit Weight
345g
Factory Pack Qty
20
Datasheet
Product Datasheet
App Notes
Why Use SSR's?
The inside story
Selecting a SSR
DC Output SSR's
Selecting a Suitable Heatsink
Use of Thermal Interface Material
How to Verify the Proper Heatsink
Effect of Forced Air Cooling
Fuse Protection of SSR's
Overvoltage Protection "P" Option MOV
SSR Reliability Whitepaper
3 Phase Motors and Heating Applications
3 Phase Motor Reversing
How to test a SSR
SSR Precautions
SSR Life Expectancy MTBF
ROHS & Reach Statement
Heatsink
SSR and Heatsink Assemblies
Crydom HDC100D160, 3.5-32VDC Input, 7-100V, 160Amp DC Output Solid State Relay
Features
Ratings from 100A to 160 Amp @ 7-150VDC
Mosfet output for reliable DC switching
Multiple modules can be wired in parallel for higher currents
UL/CSA/VDE Approved, CE Compliant to EN60950-1
Improved SEMS screw and washer
Redesigned housing with anti-rotation barriers
Direct bond copper substrate
EMC compliant to Level 3
Direct power lead frame
Epoxy free design
Spec
Crydom Part Number
HDC100D160
Switching Type
DC Load
ROHS
Yes (Details)
Control Voltage
3.5-32VDC
Load Current
160 Amp DC
Surge Capability (10ms)
470 Amp DC
Special Feature
High Current Stud Terminals
Mounting Style
Panel Mount
Load Voltage Range
7 - 100VDC
EMC Compliant
Level 3
Termination Style
Screw
Unit Weight
345g
Factory Pack Qty
20
Datasheet
Product Datasheet
App Notes
Why Use SSR's?
The inside story
Selecting a SSR
DC Output SSR's
Selecting a Suitable Heatsink
Use of Thermal Interface Material
How to Verify the Proper Heatsink
Effect of Forced Air Cooling
Fuse Protection of SSR's
Overvoltage Protection "P" Option MOV
SSR Reliability Whitepaper
3 Phase Motors and Heating Applications
3 Phase Motor Reversing
How to test a SSR
SSR Precautions
SSR Life Expectancy MTBF
ROHS & Reach Statement
Heatsink
SSR and Heatsink Assemblies
Fastron Electronics HF121-12/0.4-25-14%K, 25kVar 400VAC 14% Detuned Reactor for Power Factor Correction Capacitor Banks, 3.07mH(400VAC) 4.914mH(525VAC)
Specification
Technical Features
HF121-12/0.4-25-14%K
Electrical
Voltage
400V System/525V Capacitor
Network Frequency
50/60Hz
Nominal Power
12.5,25,40,50kvar
Inductance
3.07mH(400VAC) 4.914mH(525VAC)
Value of p%
14% (134 / 160Hz)
Type of Conductor
Aluminium/Copper(optional)
Tolerance L
5%
Linearity (5% L)
1.8 x In
Isolation Voltage
kV
Maximum Room Temperature
-10 to 45 Deg C
Internal isolation
Class F(155°C), Class H (180°C Optional)
Maximum Overload
Permanent
1.17 x In
Temporary
2 x In
Safety
Protection Thermostat
Opens at 90 °C
Degree Protection
IP00
Installation
Indoor
Standards
EN-60289, IEC60076
Weight
21kg
Datasheet
Product Datasheet
Installation Guide
HF121 Series Installation Guide