Eastron Europe CRJ-31, Converter for 3 x HY-2.0 to 3 Phase RJ12 kWh Meter Connection
Features
Quick Release Split Core System
Cable Mount
100mAmp or 100mV input and Output
Applications
Eastron Modular Metering Equipment
Accessories
RJ12cable-1SW
Specification
Fastron Part Number
CRJ-31
Technology
Splitter for HY2.0 Split Core AC Current Transformers
Rating
100mV/100mA
Bandwidth
50-60Hz
Operating Temperature Range
-15°C / 45°C
Termination Style
1M Flying leads with RJ12 Connector
Unit Weight
50g
Factory Pack Qty
10
Application Notes
Installation Guide
CRJ-31 Connector User Guide
Schurter 0034.3120, FST Glass 5x20mm Time Lag Fuse 2.5Amp, 250VAC, 10 x In, IEC 60127-2
Features
Meets UL and IEC standards
UL Recognized for 250VAC
High breaking capacity of 10 x In @ 250VAC
Meets the requirements of IEC 60127-2 for Industrial Medical, Aviation
Applications
Electrical Appliances
POwer Supply Adaptors
Switch Mode Power Supplies
Avionics
In-line protection
Specification
Schurter Part Number
0034.3120
Fuse Type
I²t Time lag
Nominal Voltage
250VAC
I²t Rating (Pre-Arcing)
16 A²/s
Nominal Current (AC rms)
2.5 Amp
Tested Breaking Capacity
10 x In @250VAC
Dimensions
5 x 20mm
Fuse Holder
0031-2203 Fuse Holders
Mounting Style
Requires fuse holder
Operating Temperature Range
-55°C / 125°C
Watt Loss
0.3W
Unit Weight
1.2g
Factory Pack Qty
10
Datasheet
Product Datasheet
Fuse Holder
0031-2203 Shock Proof Fuse Holders
Crydom PMP6050WP, Phase/Burst control, 600VAC, 50 Amp, Selectable 0-5V,0-10V,4-20mA Input, w/Overvoltage Protection
Features
Selectable Proportional Phase or Burst Control Input
Ratings from 25A to 90 Amp @ 170-600 VAC
SCR output for heavy industrial loads
Zero voltage or Instantaneous turn-on outputs
UL/CE/ROHS Compliant
Direct bond copper substrate
Direct power lead frame
Epoxy free design
Spec
Crydom Part Number
PMP6050WP
Switching Type
Phase Angle or Burst (Selectable)
ROHS/CE/UL
Yes
Control Voltage
0 - 10V/0 - 5V/4 - 20mA Proportional Input (Selectable)
Note Requires DC Power Supply for 0-5V/0-10V input modes
Load Current
50 Amp (rms)
Surge Capability
716Amp (peak)
Special Feature
Proportional Controller + SSR, Overvoltage protection
Mounting Style
Panel Mount
Load Voltage Range
420-600VAC
Dielectric Strength
4kV
Termination Style
Terminal Plug
Unit Weight
160g
Factory Pack Qty
20
Datasheet
Product Datasheet
PMP24 Installation/Wiring Guide
Equivalent
Crydom PMP2425W or Contact Us for Possible Replacement
App Notes
Why Use SSR's?
The inside story
Selecting a SSR
DC Output SSR's
Selecting a Suitable Heatsink
Use of Thermal Interface Material
How to Verify the Proper Heatsink
Effect of Forced Air Cooling
Fuse Protection of SSR's
Overvoltage Protection "P" Option MOV
SSR Reliability Whitepaper
3 Phase Motors and Heating Applications
3 Phase Motor Reversing
How to test a SSR
SSR Precautions
SSR Life Expectancy MTBF
ROHS & Reach Statement
Crydom HS072 + PMP6050WP, Panel Mount Single Phase Proportional Phase Controller with Heatsink, Selectable Input, 480-600VAC, 50 Amps @ 40 Deg C, with Overvoltage Protection
Features
Selectable Proportional Phase or Burst Control Input
Ratings from 25A to 90 Amp @ 170-600 VAC
SCR output for heavy industrial loads
Zero voltage or Instantaneous turn-on outputs
UL/CE/ROHS Compliant
Direct bond copper substrate
Direct power lead frame
Epoxy free design
Spec
Crydom Part Number
HS072 + PMP6050WP
Switching Type
Phase Angle or Burst (Selectable)
ROHS/CE/UL
Yes
Control Voltage
0 - 10V/0 - 5V/4 - 20mA Proportional Input (Selectable)
Note Requires DC Power Supply for 0-5V/0-10V input modes
Load Current
50 Amp (rms)
Surge Capability
716Amp (peak)
Special Feature
Proportional Controller + SSR + Overvoltage Protection
Mounting Style
Panel Mount
Load Voltage Range
420-600VAC
Dielectric Strength
4kV
Termination Style
Terminal Plug
Dimensions
L:139.7 x W:120.1 x 66.8mm
Unit Weight
560g
Factory Pack Qty
20
Datasheet
Product Datasheet
PMP24 Installation/Wiring Guide
HS072
App Notes
Why Use SSR's?
The inside story
Selecting a SSR
DC Output SSR's
Selecting a Suitable Heatsink
Use of Thermal Interface Material
How to Verify the Proper Heatsink
Effect of Forced Air Cooling
Fuse Protection of SSR's
Overvoltage Protection "P" Option MOV
SSR Reliability Whitepaper
3 Phase Motors and Heating Applications
3 Phase Motor Reversing
How to test a SSR
SSR Precautions
SSR Life Expectancy MTBF
ROHS & Reach Statement
Heatsink
SSR and Heatsink Assemblies
Crydom HS259DR + PMP6050WP, DIN Mount, Proportional Controller, 480-600VAC 25 Amp @ 40 Deg C, Selection for Burst/Phase Angle, 4-20mA, 0-10V, 0-5V Input, Din Rail Mount, with Overvoltage Protection
Selectable Proportional Phase or Burst Control Input
Ratings from 25A to 90 Amp @ 90-600 VAC
SCR output for heavy industrial loads
Zero voltage or Instantaneous turn-on outputs
UL/CE/ROHS Compliant
Direct bond copper substrate
Direct power lead frame
Epoxy free design
Specification
Crydom Part Number
HS259DR + PMP6050WP
Switching Type
Phase Angle or Burst (Selectable)
ROHS/CE/UL
Yes
Control Voltage
0 - 10V/0 - 5V/4 - 20mA Proportional Input (Selectable)
Note Requires DC Power Supply for 0-5V/0-10V input modes
Load Current
25 Amp (rms)
Surge Capability
597 Amp (peak)
Special Feature
Proportional Controller + SSR + Overvoltage Protection
Mounting Style
Panel Mount
Load Voltage Range
420-600VAC
Dielectric Strength
4kV
Termination Style
Terminal Plug
Unit Weight
0.4kg
Factory Pack Qty
20
Datasheet
PMP24 Series Datasheet
PMP24 Installation/Wiring Guide
GFIN
Equivalent Parts
Contact Us for Possible Replacement
TRENT TG-63H 1P/40/C/10kA, 1 Pole Miniature Circuit Breaker C Curve 40 Amp, 10kA, 400VAC
Miniature Circuit Breakers are used for over current (overload and short circuit) protection of installations and devices, and as a disconnector in case of electric shock
Features :
< 50mS Trip Delay Time
1 Pole Disconnect
10kA Short Circuit Rating
Suitable for Isolation
Customised versions available
Type B, C, D Curve available
Standards :
IEC/EN 60898
IEC/EN/AS60898-1
IP20 (IP40 Installed) IEC 61008
CE,CB
Specification
TRENT Part Number
TG-63H 1P/40/C/10kA,
Functions
1 Pole MCB - C Curve
Nominal Voltage
400VAC @ 50/60Hz
Nominal Current Range
40 Amps RMS
Trip Delay Time
< 50ms
Rated Impulse Voltage
6kV
Operating Temperature
-25 to 40 Deg C
Mechanical Operations
10,000 Ops
Insulation Voltage
690V
Breaking Capacity
10kA
Approvals
CE,CB
Standards
IEC/EN/AS60898-1, IP20 (IP40 Installed) IEC 61008 ;
Weight
350g
Enclosure Material
UL94
Factory Pack Qty
1
TRENT Headquarters
Australia
Datasheet
Product Datasheet
TRENT TG-63H 1P/16/C/10kA, 1 Pole Miniature Circuit Breaker C Curve 16 Amp, 10kA, 400VAC
Miniature Circuit Breakers are used for over current (overload and short circuit) protection of installations and devices, and as a disconnector in case of electric shock
Features :
< 50mS Trip Delay Time
1 Pole Disconnect
10kA Short Circuit Rating
Suitable for Isolation
Customised versions available
Type B, C, D Curve available
Standards :
IEC/EN 60898
IEC/EN/AS60898-1
IP20 (IP40 Installed) IEC 61008
CE,CB
Specification
TRENT Part Number
TG-63H 1P/16/C/10kA
Functions
1 Pole MCB - C Curve
Nominal Voltage
400VAC @ 50/60Hz
Nominal Current Range
16 Amps RMS
Trip Delay Time
< 50ms
Rated Impulse Voltage
6kV
Operating Temperature
-25 to 40 Deg C
Mechanical Operations
10,000 Ops
Insulation Voltage
690V
Breaking Capacity
10kA
Approvals
CE,CB
Standards
IEC/EN/AS60898-1, IP20 (IP40 Installed) IEC 61008 ;
Weight
350g
Enclosure Material
UL94
Factory Pack Qty
1
TRENT Headquarters
Australia
Datasheet
Product Datasheet
Schurter 5120.2207.0, IEC Appliance Inlet, C14/M with 1 Stage EMC (RFI) Line Filter, 15 Amp, Front Side Mounting, Snap On
Features
Panel Mount : Screw-on or snap-in mounting from front side
2 Functions : Appliance Inlet Protection class II, Line filter in standard and medical version
Solder terminals or quick connect terminals
Characteristics
Compact high performance filter
Suitable for use in equipment according to IEC/UL 60950
Suitable for use in medical equipment according to IEC/UL 60601-1
Other versions on request
Standard version without X-capacitor
Polarized C8 connector
Specification
Schurter Part Number
5120.2207.0
Rated Voltage
250V
Rated Current
15A
Filter Stages
1 Stage Standard
Operating Temperature
-25°C to 85°C
Filter Type
Differential and Common Mode
Fuse Holder
N/A
Line Switch
N/A
Mounting
Panel Mount - Screw in
Material
Thermoplastic, black, UL 94V-0
Termination Style
C14 Male to Quick Connects
Weight
60g
Factory Pack Qty
1
Protection Class
From front side IP 40 acc. to IEC 60529
Isolation
1.7kV
VDE/UL/CSA/ROHS
Yes
Datasheet
Product Datasheet
Alternatives
version without line filter 2576; 2578
TRB-22D-B-240, 22mm Pushbutton Momentary BLUE 240VAC, Plastic, IEC60947-5-1
Pushbutton Switches will activate while the contacts are connected. Widely Used for Rugged Industrial Applications Including Critical Machinery requiring safe operation by the user.
Features :
240VAC or 24VAC/DC (400VAC Special Orders)
1 Pole Momentary
Rated for 6 Amp @ 230VAC, or 0.3 Amp @ 230VDC
Ø 22.5mm Cutout
Standards :
IP40
IEC60947-5-1
CE
Specification
TRENT Part Number
TRB-22D-B-240
Functions
Momentary
Nominal Voltage
230VAC @ 50/60Hz
Impulse Voltage Wear Resistance
6kV
Short Circuit Protection (Fuse)
Recommend 10A gG Fuse
Nominal Current Range AC
6 Amp @240VAC
Nominal Current Range DC
0.3 Amp @ 230VDC
Mechanical Compression Force at Closing
20N
Mechanical Compression Force at Closing
8N
Humidity
35-85%
Approvals
CE
Standards
IP40, IEC60947-5-1
Weight
Enclosure Material
UL94V0
Factory Pack Qty
1
TRENT(Fastron) Head Office
Australia
Datasheet
Product Datasheet
Crouzet 87622061, Totalizer/Counter with orange Backlit Display CTR24 4-30VDC, Lithium Battery Powered 8 year battery Life
Counter with two totalizers with Common Input
IP65
4-30VDC, 10-260VAC Aux Supply
6 Digit Display (8mm)
7.5kHz Maximum Frequency
50. x 24mm Cutout
Scaling Factor
Rest On Panel or External Inhibit
Suitable to replace 87622062 & 87610040
Datasheet
Product Datasheet
TRB-BD33-IP65, 1 x NO, 3 Position Toggle Switch BLACK, 3 Amp @ 240VACVAC, Plastic/Metal, IEC60947-5-1
Toggle Switches are used to Toggle between 2 or 3 Digital or Analogue Input Signals or to simply turn off control signals. Widely used for Rugged Industrial Applications Including Critical Machinery requiring safe and reliable repetitive operation by the user.
Features :
600V Insulation Rating
240VAC @ 3 Amp
22mm Cutout
Standards :
IP40
IEC60947-5-1
CE
Specification
TRENT Part Number
TRB-BD33-IP65
Functions
Latching 1 x NO (Right ON Postion 1), Centre = OFF, 1 x NO (Left ON Postion 2)
Switch Type
Latching 2 x NO
Nominal Voltage
240VAC @ 50/60Hz
Rated Impulse Voltage
6kV
Nominal Current Range AC
3 Amp @240VAC
Rated Insulation Voltage
600VAC
Humidity
35-85%
Approvals
CE
Standards
IEC60947-5-1, IP20 (IP40 Installed)
Weight
65g
Enclosure Material
UL94V0
Factory Pack Qty
1
TRENT(Fastron) Head Office
Australia
Datasheet
Product Datasheet
Fastron FDV-300-V05-24, DC Voltage Transducer, Din Rail Mount, 0-300VDC, 0-5V output, 24VDC Supply Voltage, 150mS Response
150mS Response Time
PC 94 UL V0
Input signals can be converted to insulated 5V DC output (for voltage output type)
Each unit needs just 22.5 x 114 mm depth DIN Rail cabinet space
Specification
Fastron Part Number
FDV-300-V05-24
Analogue Output
0-5V
Input
0 - 300VDC
Measurement Range
120%
Overload
150% Continuous
Operating Temperature
-30 - 70°C
Operating Voltage
24VDC +/-15%
Voltage Isolation (1 min)
2.5kV
Accuracy
1%
Response Time
150mS
Termination Style
Screw
Mounting Style
DIN Rail Mount
Safety
CE, UL94V0
Weight
170g
Factory Pack Qty
1
Datasheet
Product Datasheet