TRB-22D-Y-240, 22mm Pushbutton Momentary AMBER 240VAC, Plastic, IEC60947-5-1
Pushbutton Switches will activate while the contacts are connected. Widely Used for Rugged Industrial Applications Including Critical Machinery requiring safe operation by the user.
Features :
240VAC or 24VAC/DC (400VAC Special Orders)
1 Pole Momentary
Rated for 6 Amp @ 230VAC, or 0.3 Amp @ 230VDC
Ø 22.5mm Cutout
Standards :
IP40
IEC60947-5-1
CE
Specification
TRENT Part Number
TRB-22D-Y-240
Colour
Black Body, Red Button
Functions
Momentary
Nominal Voltage
230VAC @ 50/60Hz
Impulse Voltage Wear Resistance
6kV
Short Circuit Protection (Fuse)
Recommend 10A gG Fuse
Nominal Current Range AC
6 Amp @240VAC
Nominal Current Range DC
0.3 Amp @ 230VDC
Mechanical Compression Force at Closing
20N
Mechanical Compression Force at Closing
8N
Humidity
35-85%
Approvals
CE
Standards
IP40, IEC60947-5-1
Weight
Enclosure Material
UL94V0
Factory Pack Qty
1
TRENT(Fastron) Head Office
Australia
Datasheet
Product Datasheet
TGLW30-3R100, 3 Pole Rotary/CAM Switch RED, 100 Amp 400VAC, Plastic, Direct Type, IEC60947-5-1
Rotary CAM Switches are used to Isolate or Switch under load. Widely Used for Rugged Industrial Applications Including Critical Machinery requiring safe operation by the user.
Features :
400VAC in various Ratings
3 Pole 2 Postion
64mm x 64mm Cutout
Standards :
IP40 Front, IP20 Terminals
IEC 60947-1,-3
IEC 60204
Specification
TRENT Part Number
TGLW30-3R100
Functions
3 Pole AC Disconnect CAM Switch
Nominal Voltage
400VAC @ 50/60Hz
Rated Impulse Voltage
6kV
Nominal Current Range AC
100 Amp @400VAC
Rated Insulation Voltage
690VAC
Humidity
10-85%
Approvals
CE
Standards
IEC 60947-1,-3, IEC 60204, IP20 (IP40 Installed)
Weight
470g
Enclosure Material
UL94V0
Factory Pack Qty
1
TRENT(Fastron) Head Office
Australia
Datasheet
Datasheet
TGB2-ES542G, 40MM Emergency Stop Button, 1 Pos, Twist Release, 1 x NC, IEC60947-5-1
Emergency Stop Buttons are used to Isolate Control Power. Widely used for Rugged Industrial Applications Including Critical Machinery requiring safe operation by the user.
Features :
600V Insulation Rating
240VAC @ 3 Amp
22mm Cutout
30mm,40mm,60mm Button Sizes
Twist or Key Release Types
Standards :
IP20
IEC60947-5-1
CE
Specification
TRENT Part Number
TGB2-ES442G
Functions
1 Pole Emergency Stop 40MM
Switch Type
Twist Release 1 x NC
Nominal Voltage
240VAC @ 50/60Hz
Rated Impulse Voltage
6kV
Nominal Current Range AC
3 Amp @240VAC
Rated Insulation Voltage
600VAC
Humidity
35-85%
Approvals
CE
Standards
IEC60947-5-1, IP20 (IP40 Installed)
Weight
80g
Enclosure Material
UL94V0
Factory Pack Qty
1
TRENT(Fastron) Head Office
Australia
Datasheet
Product Datasheet
TGB2-ES642G, 60MM Emergency Stop Button, 1 Pos, Twist Release, 1 x NC, IEC60947-5-1
Emergency Stop Buttons are used to Isolate Control Power. Widely used for Rugged Industrial Applications Including Critical Machinery requiring safe operation by the user.
Features :
600V Insulation Rating
240VAC @ 3 Amp
22mm Cutout
30mm,40mm,60mm Button Sizes
Twist or Key Release Types
Standards :
IP20
IEC60947-5-1
CE
Specification
TRENT Part Number
TGB2-ES642G
Functions
1 Pole Emergency Stop 60MM
Switch Type
Twist Release 1 x NC
Nominal Voltage
240VAC @ 50/60Hz
Rated Impulse Voltage
6kV
Nominal Current Range AC
3 Amp @240VAC
Rated Insulation Voltage
600VAC
Humidity
35-85%
Approvals
CE
Standards
IEC60947-5-1, IP20 (IP40 Installed)
Weight
80g
Enclosure Material
UL94V0
Factory Pack Qty
1
TRENT(Fastron) Head Office
Australia
Datasheet
Product Datasheet
Schurter 0034.3119, FST 5x20mm Time Lag Fuse 1.6Amp, 250VAC, 10 x In, IEC 60127-2
Features
Meets UL and IEC standards
UL Recognized for 250VAC
High breaking capacity of 10 x In @ 250VAC
Meets the requirements of IEC 60127-2 for Industrial Medical, Aviation
Applications
Electrical Appliances
Power Supply Adapters
Switch Mode Power Supplies
Avionics
In-line protection
Specification
Schurter Part Number
0034.3119
Fuse Type
I²t Time lag
Nominal Voltage
250VAC
I²t Rating (Pre-Arcing)
3.3 A²/s
Nominal Current (AC rms)
1 Amp
Tested Breaking Capacity
10 x In @250VAC
Dimensions
5 x 20mm
Fuse Holder
0031-2203 Fuse Holders
Mounting Style
Requires fuse holder
Operating Temperature Range
-55°C / 125°C
Watt Loss
0.2W
Unit Weight
1.2g
Factory Pack Qty
10
Datasheet
Product Datasheet
Fuse Holder
0031-2203 Shock Proof Fuse Holders
Fastron FDV-1000-V05-24, DC Voltage Transducer, Din Rail Mount, 0-1000VDC, 0-5V output, 24VDC Supply Voltage, 150mS Response
150mS Response Time
PC 94 UL V0
Input signals can be converted to insulated 5V DC output (for voltage output type)
Each unit needs just 22.5 x 114 mm depth DIN Rail cabinet space
Specification
Fastron Part Number
FDV-1000-V05-24
Analogue Output
0-5V
Input
0 - 1000VDC
Measurement Range
120%
Overload
150% Continuous
Operating Temperature
-30 - 70°C
Operating Voltage
24VDC +/-15%
Accuracy
1%
Response Time
150mS
Voltage Isolation (1 min)
2.5kV
Termination Style
Screw
Mounting Style
DIN Rail Mount
Safety
CE, UL94V0
Weight
170g
Factory Pack Qty
1
Datasheet
Product Datasheet
Fastron FDV-50-V05-24, DC Voltage Transducer, Din Rail Mount, 0-100VDC, 0-5V output, 24VDC Supply Voltage, 150mS Response
150mS Response Time
PC 94 UL V0
Input signals can be converted to insulated 5V DC output (for voltage output type)
Each unit needs just 22.5 x 114 mm depth DIN Rail cabinet space
Specification
Fastron Part Number
FDV-50-V05-24
Analogue Output
5V
Input
0 - 50VDC
Measurement Range
120%
Overload
150% Continuous
Operating Temperature
-30 - 70°C
Operating Voltage
24VDC +/-15%
Voltage Isolation (1 min)
2.5kV
Accuracy
1%
Response Time
150mS
Termination Style
Screw
Mounting Style
DIN Rail Mount
Safety
CE, UL94V0
Weight
170g
Factory Pack Qty
1
Datasheet
Product Datasheet
Iskra Doo UMT540-HSHFNAAAA, Multifunction Power Transducer, Class 0.5S, 4 Wire, 600V L-N, 5A AC Input 50/60Hz, 24-300VDC or 40-276VAC Aux Input, 4 Programmable analogue outputs, USB, Ethernet, RS485 Comms
(U)MT version = Ring type terminal block
Class 0.5S Active, Class 0.2 Reactive (EN 60688) , Class 0.1 on Comms
RS485 Comms as standard
Up to 4 I/O Modules (analogue output, Multiple break point, non-linear characterstics
Automatic range of nominal current up to 12.5 A (Includes 5A/1A CT Input) and nominal voltage up to 600 V L-N
Adjustable tariff clock, display of electric energy consumption in optional currency
RMS values of currents and voltages
Measurements of active, reactive, apparent power and power factor
Measurements of energy in all 4 quadrants Average values of measurands per interval
Certified ship version available
The Power Transducer is intended for measuring, analysing and monitoring single-phase or three-phase electrical power network. The meter records TRMS value according to the principle of fast sampling of voltage and current signals. A built-in microprocessor calculates measurands (voltage, current, frequency, energy, power, power factor, phase angles, etc.) from the measured signals.
Features :
Measurement of instantaneous values of more than 140 quantities (U, I, P, Q, S, PF, PA, f, f, MD, etc.).
Accuracy Class 0.5s Active, Class 0.2 Reactive (EN 60688), Class 0.1 on Comms
32 Adjustable Alarms
Input frequency 50/60 Hz or 400 Hz
RS 232/RS485 communication up to 115,200 bit/s (Optional) or USB communication as standard
MODBUS RTU communication protocol
Up to 4 inputs or outputs (pulse outputs, alarm outputs, tariff inputs)
Universal Supply 24-300VDC or 40-276VAC
Automatic range of nominal current up to 12.5 A and nominal voltage up to 600 V
User-friendly PC MiQen software
Optional Remote Display Support
Specification
Iskra Doo Part Number
UMT540-HSHFNAAAA
Functions
3 Phase Power Transducer
Supply Voltage
24-300VDC or 40-276VAC
Nominal Measurement Range
600V L-N, 5 Amp
Maximum Measurement Range
600V L-N, 12.5 Amp
Alarm
N/A
Tariff Input
N/A
Output(s)
4 x Analogue
Accuracy
Class 0.2 (I,U,F,PF,θ,THD) Class 0.5s(Active), Class 0.2 (Reactive)
Battery Backup
N/A
Real Time Clock
1min/month (30ppm)
Terminations
Ring Type Terminal Block
Isolation
3.5kV
Comms
USB (standard) RS232 2400-115200 b/s (RS485 Optional)
Weight
900g
Enclosure Material
UL94,
Factory Pack Qty
1
EU Directives
EN61010, EN60688,EN61326-1,60529,60068-2-1/-2/-6/-27/-30
Safety
Protection Class II
600V rms, installation category II
300V rms, installation category III
Pollution Degree 2 in compliance with SIST EN 61010-1:2002
Enclosure Material
PC/ABS non combustable-self-extinguishability, complying with UL 94 V-0
Enclosure Protection
IP20
Shock Withstand
300g 8ms Pulse . 6 Shocks in each of 3 axes
Vibration Withstand
0.7g, 3...100Hz, 1oct/min 10 cycles in each of three axes
Operating Temperature
-20 →+70 °C
Datasheet
Product Datasheet
Software
MiQen Setting Software
TRI-22-Y240, 22mm LED Indicator AMBER 240VAC, Plastic, IP65, IEC60947-5-1
LED indicator Series will activate while the contacts are connected to the rated voltage. Widely Used for Rugged Industrial Applications Including Critical Machinery requiring safe operation and visual Indication by the user.
Features :
240VAC or 24VAC/DC (400VAC Special Orders)
LED Illumination
Ø 22.5mm Cutout
Long Life
Replacement Beads Available
Standards :
IP65
IEC60947-5-1
CE
Specification
TRENT Part Number
TRI-22-Y240
Functions
LED Indicator Only
Nominal Voltage
230VAC @ 50/60Hz
Impulse Voltage Wear Resistance
6kV
Illumination Type
Amber LED
Short Circuit Protection (Fuse)
Recommend 10A gG Fuse
Mechanical Compression Force at Closing
20N
Mechanical Compression Force at Closing
8N
Humidity
35-85%
Approvals
CE
Standards
IP65, IEC60947-5-1
Weight
Enclosure Material
UL94V0
Factory Pack Qty
1
TRENT(Fastron) Head Office
Australia
Datasheet
Product Datasheet
TRI-22-W240, 22mm LED Indicator WHITE 240VAC, Plastic, IP65, IEC60947-5-1
LED indicator Series will activate while the contacts are connected to the rated voltage. Widely Used for Rugged Industrial Applications Including Critical Machinery requiring safe operation and visual Indication by the user.
Features :
240VAC or 24VAC/DC (400VAC Special Orders)
LED Illumination
Ø 22.5mm Cutout
Long Life
Replacement Beads Available
Standards :
IP65
IEC60947-5-1
CE
Specification
TRENT Part Number
TRI-22-W240
Functions
LED Indicator Only
Nominal Voltage
230VAC @ 50/60Hz
Impulse Voltage Wear Resistance
6kV
Illumination Type
White/Clear LED
Short Circuit Protection (Fuse)
Recommend 10A gG Fuse
Mechanical Compression Force at Closing
20N
Mechanical Compression Force at Closing
8N
Humidity
35-85%
Approvals
CE
Standards
IP65, IEC60947-5-1
Weight
Enclosure Material
UL94V0
Factory Pack Qty
1
TRENT(Fastron) Head Office
Australia
Datasheet
Product Datasheet