MBL43, Mechanical interlock for KNL80 to KNL110 Contactors
Features
Snap on
Safety interlock prevents contactor from turning on during maintenance
For Iskra KNL43 to KNL110 Contactors
RCS-1800-0250 Three-Phase Flexible Current Sensor System (Rogowski Coils):
The RCS-1800 three-phase flexible rope CT from Magnelab converts AC input current of up to 5000 amperes to an AC output of 0.333 volt.
A 9 to 36 VDC power supply is required to operate these coils. The RCS-1800 comes with an integrator which includes flexible strain relief cables.
Included is an 12 inch circumference rope CT with Integrator, and 8 feet of twisted pair (600V) output leads.
Magnelab Coils come with 10 year warranty
Suitable Alternative to Solar Edge CTRC-07500-0250
Specification
Magnelab Part Number
RCS-1800-0250
Function
AC Current Measurement
Nominal Measurement Current (Ipn)
250 Amp RMS
Measurement Range
10% - 130% if Ipn
Frequency Measuring Range
50-1500Hz (15th Harmonic)
Operating Voltage
9 - 36VDC
Accuracy
1% from 25 to 500 Amp
Phase Angle
< 0.5 Degrees
Coil Diameter (⌀)
6 Inch
Coil Circumference
18 Inch
Integrator to Coil Cable
8 Feet Shielded
Maximum Voltage
600V (on bare conductor)
Operating Temperature
-15°C to 65°C
Storage Temperature
-45°C to 80°C
Power Consumption
< 2VA
Overload
20,000 Amp (continuous)
Termination Style
Screw
Weight
1200g
Certification
CE
Factory Pack Qty
1
Certifications
UL Recognized E96927 to IEEE C57.13, CAN/CSA 60044-1
Meets UL STD 61010-1, CAN/CSA C22.2 No. 61010
CE
ROHS
Datasheet
Product Datasheet
Application Notes
RCS/RCT Series Installation Guide
Risbabh EMDC 6002-1000-HA-C-2R, 4 Channel DC kWh Meter, Class 0.5, 150-150mV Shunt input, 201-1000VDC, 2 Alarm/Pulse Outputs, RS485 & USB Comms, 4 Line LCD Display, 60-300VAC/DC Aux Supply, Internal Logging
2 Pulse/Alarm Outputs
50-150mV Shunt Input, and nominal voltage 201-1000VDC
RS 485 communication up to 57,600 bit/s
USB Port
8MB Internal Storage
DC Measurement Only
The meter is intended for measuring, analysing and monitoring DC Power. The meter records TRMS value according to the principle of fast sampling of voltage and current signals. A built-in microprocessor calculates measurands (voltage, current,, energy, power.) from the measured signals.
Features :
96 x 96mm Panel Mount
Accuracy class 0.5
Simple Menu
RS 485 communication up to 57,600 bit/s
USB Comms
8MB Internal Logger
60-300VAC/DC power supply
Specification
Rishabh Part Number
EMDC 6002-1000-HA-C-2R
Functions
4 Channel DC kWh Meter, Energy Meter
Supply Voltage
60-300VAC/DC
Nominal Measurement Range
201-1000VDC
Maximum Measurement Range
201-1000VDC
Display
Single Line LCD
Pulse/Relay Output
2
Accuracy
Class 0.5 (Energy)
USB
YES
Real Time Clock
1min/month (30ppm)
Isolation
3.5kV
RS485 Modbus RTU
YES 57,600bps
Weight
450g
Certification
EN 61010-1 Installation Category III
Factory Pack Qty
1
Environment
IP54
Safety
Protection Class II
Enclosure Material
Mablex with fire protection to UL94-V-O. Self extinguishing
Enclosure Size
96 x 96mm x 83.5mm (72mm behind panel)
Terminals
Rising Cage 4mm² (12 AWG) cable max
Humidity
< 75% Non Condensing
Operating Temperature
-20 →+70 °C
Datasheet
Product Datasheet
Software
Software User Manual
Software Download Link
Application Notes
1)Reading Data from Registers -> Download file
2)Maximum Memory Size -> Read below
Max Available Memory Locations in 8MB Size = 273030
Actual parameter stored in Each log (Memory locations used) = Date +time+Number of parameter selected by user
Considering your example for 2 parameters:
Number of parameter selected by user = 2 (kwh & kVA)
Actual parameter stored in Each log = 1(Date) +1(time)+ 2 (Parameters) = 4 (memory locations used per log)
Maximum log that can be stored = Max Memory Location/Actual parameter stored in Each log =273030/4= 68257
Timelog Interval setting = 15 minutes
Log in one day = (60 /Timelog Interval setting) * 24 =(60/15)*24 = 96 Logs
Max Days = Maximum log that can be stored / log in one day = 68257 / 96 = 711 days = 1 Year & 11 Months = 23 Months.
Iskra Doo RI62J C 32-10kA, 2 Pole DC Miniature Circuit Breaker Disconnect Switch C Curve 32 Amp, 440VDC, 10kA
Miniature Circuit Breakers are used for over-current (overload and short-circuit) protection of installations and devices, and as a disconnector in case of electric shock
Features :
< 50mS Trip Delay Time
1 Pole Disconnect
10kA Short Circuit Rating
Suitable for Isolation
Customised versions available
Type B, C, D Curve available
Standards :
IEC/EN 60898,60947-3
IP20 (IP40 Installed) IEC 61008
Specification
Iskra Doo Part Number
RI62J C32
Functions
2 Pole MCB - C Curve
Nominal Voltage
440VDC
Nominal Current Range
32 Amp RMS
Trip Delay Time
< 50ms
Rated Frequency
50/60 Hz
Operating Temperature
-25 to 55 Deg C
Rated Operations
10,000 Ops
Surge Current
500V
Short Circuit Current
10kA
Approvals
VDE, GOST-R
Standards
IEC/EN 60898,60947-1/2, IP20 (IP40 Installed) IEC 61008 ;
Weight
200g
Enclosure Material
UL94
Factory Pack Qty
1
Datasheet
Product Datasheet
Keysolu KS32 24-24Z2 & F41F-1Z-C2-1, Slim Solid State Relay & Socket with Screw Terminals 24VDC Input, 2 Amp @ 240VAC
Features
Multirange input 12-24VAC/DC Nominal
Load Rating 2 Amp @ 240VAC
DIN Rail Mount
Ultra slim package
UL Listed (Hongfa make)
CE Compliant to IEC 60664
IP67
Specification
Fastron Part Number
KS32 24-24Z2 & F41F-1Z-C2-1
Switching Type
240VAC
Control Input
24VDC+/-10%
Current @ Rated Voltage
2 Amp
Contact Arrangement
1 x Slim SSRSPST
Approvals
UL,CE
Dimensions
76.6 x 94.7 x 6.2
Ingress Protection
IP20
Control Input Power
25mA
Relay Type
Keysolu KS32 24-24Z2
Termination Style
Screw Terminals
Unit Weight
60g
Factory Pack Qty
100
Datasheet
Relay Base Datasheet
Relay Datasheet
Fastron Electronics GT-AV(0-415)-A-4, AC Voltage Transducer, 0-415V AC input, 100-240VAC/DC aux, 0-10V Average RMS output
Adjustable Zero and Span Setting
250mS Response Time
PC 94 UL V0
Input signals can be converted to insulated 0-10V DC output (for direct current output type)
Each unit needs just 22.5 x 114 mm depth DIN Rail cabinet space
Specification
Fastron Electronics Part Number
GT-AV(0-415-A-4
Control Output
0-10V Average RMS
Input
0-415VAC
Over Range
x 1.5
Operating Temperature
0 - 60°C
Load Voltage
100-240VAC/DC
Span Adjustment Range
+/-10%
Zero Adjustment Range
+/-5%
Termination Style
Screw
Mounting Style
DIN Rail Mount
Case Material
PC - UL 94 V0
Weight
170g
Factory Pack Qty
1
Datasheet
Product Datasheet
Fastron Electronics GT-AV(0-415)-D-4, AC Voltage Transducer, 0-415V AC input, 22-60VAC/DC aux, 0-10V Average RMS output
Adjustable Zero and Span Setting
250mS Response Time
PC 94 UL V0
Input signals can be converted to insulated 0-10V DC output (for direct current output type)
Each unit needs just 22.5 x 114 mm depth DIN Rail cabinet space
Specification
Fastron Electronics Part Number
GT-AV(0-415)-D-1
Control Output
0-10V Average RMS
Input
0-415VAC
Over Range
x 1.5
Operating Temperature
0 - 60°C
Load Voltage
22-60VAC/DC
Span Adjustment Range
+/-10%
Zero Adjustment Range
+/-5%
Termination Style
Screw
Mounting Style
DIN Rail Mount
Case Material
PC - UL 94 V0
Weight
170g
Factory Pack Qty
1
Datasheet
Product Datasheet
Schurter FMAC-0953-6410, 1 Stage EMC (RFI) Line Filter for 3-Phase 3 Wire Solar or Industrial Systems, 64 Amp, 480VAC
Features
3 phase line filter with standard attenuation
Available as high voltage filter (up to 520 VAC)
Applications
Voltage rating 480 and 520 VAC for world wide acceptance
Protection against interference voltage from the mains
For photovoltaic systems and industrial applications
Suitable for use in equipment according to IEC/UL 60950
Specification
Schurter Part Number
FMAC-0953-6410
Rated Voltage
480V
Rated Current
64A
Filter Stages
1 Stage (3 Phase)
Operating Temperature
-25°C to 85°C
Connection
3 Wire + Earth
Filter Type
Excellent Attenuation
Leakage Current
5mA
Mounting
Panel Mount - Case 32-7
Material
Metal
Termination Style
Screw
Weight
4kg
Factory Pack Qty
1
Protection Class
From front side IP 40 acc. to IEC 60529
Isolation
2.2kV
VDE/UL/CSA/ROHS
Yes
Datasheet
Product Datasheet
DT04-08PA Kit, Deutsch Connector for Gigavac MX, GX Auto Contactors with Deutsch Connection, Comes with 4 Pins
Specification
Part Number:
DT04-08PA
Series:
DT Series
Insulation:
.088-.145 [2.24-3.68]
Wire Size:
14, 16, 18, 20
Required Wedgelock:
W8P
Keyed:
Yes, A key
Color:
Gray
Material:
Plastic
Shape:
Rectangular
Connector Style:
Receptacle
Cavities:
8
Contact Size:
16
Rating:
13
Holds Pin/Socket:
Pin
Flange/In-line/PCB Mount:
In-line
Features
Product Type Features
Connector Style : Housing for male terminals
Connector System : Wire-to-Wire
Sealable : Yes
Hybrid Connector : No
Primary Locking Feature : Integrated in Housing
Connector & Contact Terminates To : Wire & Cable
Strain Relief : Add By Accessory
Row-to-Row Spacing : 45.45 mm [ .175 in ]
Configuration Features
Number of Positions : 8
Number of Rows : 2
Blank Cavity Position : 0
Electrical Characteristics
Nominal Voltage Architecture (V): 12, 24, 48
Operating Voltage (VAC): 250
Operating Voltage (VDC): 250
Body Features
Color : Gray
Connector Code : A
Cable Exit Angle : 180°
Body Material : PA GF
Contact Features
Mating Pin Diameter : 1.59 mm [ .0625 in ]
Contact Rating (Max) (A): 13
Mechanical Attachment
Connector Mounting Type : Cable Mount (Free-Hanging), Fixing Screw
Mounting Feature : With
Terminal Position Assurance : Yes
Polarized : Yes
Housing Features
Centerline (Pitch) : 9.12 mm [ .359 in ]
Dimensions
Width : 36.45 mm [ 1.435 in ]
Height : 23.88 mm [ .94 in ]
Length : 45.67 mm [ 1.798 in ]
Usage Conditions
Operating Temperature Range : -55 – 125 °C [ -67 – 257 °F ]
Operation/Application
Circuit Application : Power & Signal
Industry Standards
Degree of Protection : IP68, IP6K9K
UL Flammability Rating : 12mm Flame Test per Standard UL-94
Agency/Standard : SAE J2030
Packaging Features
Packaging Method : Box
Packaging Quantity : 350
Other
Connector Position Assurance Capable : No
Datasheet
https://www.te.com/commerce/DocumentDelivery/DDEController?Action=showdoc&DocId=Customer+Drawing%7FDT04-08PX%7FB%7Fpdf%7FEnglish%7FENG_CD_DT04-08PX_B.pdf%7FDT04-08PA
SKU
A03306
Brand
Deutsch/TE
Gigavac GX46FD, Contactor SPST-NO, 600+ AMP, 12-800VDC, 48VDC Coil, M4 Coil Screw, SPST-NO Auxiliary Contact, IP67, IP69K
Features
Hermetically Sealed (Patented) rated to 175 Deg C
UL1604 for Class I & II Div 2 and Class III for use in hazardous locations
IP67 & IP69K
SAE J1171 External ignition protection
ISO8846 Protection against ignition around flammable gasses
CE Approved
High Efficiency Dual DC Coils - Very low 12,24,48VDC continuous coil power with no EMI emissions or cross-talk on your system control power
Ideal for battery powered systems or where low power is needed
PWM option provides additional drive control flexibility
Built in Coils suppression for all DC Coils
Flexible package for installation
Chassi level power terminals
Salt Fog MIL-STD-810
Specification
Gigavac Part Number
GX46FD
Main Contact Type
SPST-NO
Auxiliary Contact Type
None
Coil Voltage
48VDC
Load Current
600+ Amp
Mechanical Life @ 0 Amp
1,000,000 Operations
Dielectric at Sea Level (leakage <1mA)
2.2kV rms
Control Input Terminals
M4 Screw
Aux Contact Terminals
M4 Coil Screw
Special Feature
Hermetically Seal rated to 175 Deg C
Mounting Style
Panel Mount (M5)
Load Voltage Range
12-800VDC
Standards
UL1604, IP67, IP69K, SAE J1171, ISO8846
Termination Style
M8
Unit Weight
900g
Factory Pack Qty
1
Datasheet
Product Datasheet
Fastron Electronics AM5S-C-N2-D-N, 48x24mm Digital Totaliser 7kHz, NPN 12VDC, 22-60VAC/DC supply
Large 5 Digit 0.4 Inch LED Display
250mS Response Time
PC 94 UL V0
Input signals can be NPN, PNP, or 24VDC Pulses depending on the model used
Each unit needs just 48 x 24mm Panel Space
86.2mm Depth
Specification
Fastron Electronics Part Number
AM5S-C-N2-D-N
Input
NPN 12VDC
Measurement Range
0 - 7kHz
Operating Temperature
0 - 60°C
Load Voltage
22-60VAC/DC
Termination Style
Screw
Mounting Style
48 x 24mm Panel Mount
Case Material
PC - UL 94 V0
Safety Approvals
CE
Weight
320g
Factory Pack Qty
1
Datasheet
Product Datasheet
Application Notes
Panel Meters Blog Articles