Search results for "텔레@upcoin24``이더리움전송대행리플매입"
-
PFR-X+ 06R, Power Factor Regulator (Beluk BLR-CX 06RL), 6 Step, 110-480V 50/60HZ
PFR-X+ 06R, Power Factor Regulator (Beluk BLR-CX 06RL), 6 Step, 110-480V 50/60HZ Single CT Sensing Isolated Switching of Power Factor Correction Contactors Cos ϕ Setting 0.85 to 0.95 CAP Auto CT Secondary Selection Backlit LCD Display Various Program Combinations IP41 Up to 6 steps Measurement System - Automatic/Manual 230VAC Aux Supply Configurable Alarms Dual Password Protection Programmable Fan Control Programmable 1A/5A CT Ratio Specification Electronicon Part Number PFR-X+ 06R Function Reactive Power Correction Nominal Voltage (Un) 110-480VAC Line to Line Supply Voltage 90-300VAC (L-N), 15VA 45-65Hz Relay Rating 250VAC/10Amp Switch Delay Time 1s - 1200s User Adjustable Alarm 1 x Relay as above Temperature Alarm 1 x Relay as above Re-connection Delay Time 50 - 1200s User Adjustable Desired Power Factor 0.80 IND - 0.80 CAP Number of Output Relays 6 Smallest Capacitor Current 10mA CT Input Range 15mA - 6 Amp LCD Display Accuracy Voltage +/-0.5%, Frequency +/-0.1%, Power +/-1% Energy Class 1 Phase Angle Error +/- 1% at I > 3% of range Comms N/A Termination Style Screw Weight 700g Certification IEC 654-1 Factory Pack Qty 1 Material of housing PC/ABS Unflammable, according to UL 94 V-0 Enclosure protection IP50 for case, IP20 for terminals Safety According to EN 61 010-1, installation category III Pollution degree 2 Operating Temperature -20...60 °C Datasheet User Manual Modbus RS485 User Manual Iskra Quick Setup Guide Application Notes Discharge Resistor Usage Power Factor Correction Blog Quick Start Guide(Blog)
$569.00
$671.42 inclGST -
DK 100 B5, Split Core Hall Effect DC Current Transducer, 50, 75, 100A DC, 0-5V unipolar output, 20-50VDC supply
Free Aus Post Shipping for $300 SpendLEM DK 100 B5, Split Core Hall Effect DC Current Transducer, 50, 75, 100A DC, 0-5V unipolar output, 20-50VDC supply Compact and versatile Split Core DC current sensor, selectable 50, 75, 100 Amp DC. Choice of output types: 0-20mA, 4-20 mA, 0-5 V or 0-10 V Features Split Core DC Unipolar Measurement 0-5V voltage output Busbar, or panel mounting Isolated plastic case recognised according to UL94-V0 Advantages Large aperture for busbar/cable up to 21.7mm sqr High isolation between primary and secondary circuits Easy installation DIN Rail Kit available Applications -Automation Systems Analogue current reading for remote monitoring (e.g. Motor) -Data Loggers Self Powered. Will not drain data logger batteries -Panel Meters Simple connection displays power consumption Specification LEM Part Number DK 100 B5 Technology DC Current Transformer with Process Output ROHS Yes Supply Voltage 20-50VDC Nominal Current (RMS + DC) 50,75,100 Amp Selectable Response Time < 100ms Output 0-5V Analogue Isolation 3kV (AC, 50Hz, 1 min) Bandwidth DC Mounting Style Panel Mount Operating Temperature Range -40°C / 85°C Accuracy 2% Termination Style 2 x UNC8 Cylindric Head Unit Weight 120g Factory Pack Qty 6 Datasheet Product Datasheet Application Notes LEM Applications Manual 3rd Edition
-
D06D100, 3-32VDC Input, 1-48VDC Load, 100Amp DC Output Solid State Relay
Crydom D06D100, 3-32VDC Input, 1-48VDC Load, 100Amp DC Output Solid State Relay Features Ratings from 7A to 100 Amp @ 1-48VDCVDC Mosfet output for reliable DC switching Multiple modules can be wired in parallel for higher currents UL/CSA/VDE Approved, CE Compliant to EN60950-1 Improved SEMS screw and washer Redesigned housing with anti-rotation barriers Direct bond copper substrate EMC compliant to Level 3 Direct power lead frame Epoxy free design Spec Crydom Part Number D06D100 Switching Type DC Load ROHS Yes (Details) Control Voltage 3.5-32VDC Load Current 100 Amp DC Surge Capability (10ms) 1200 Amp DC Special Feature None Mounting Style Panel Mount Load Voltage Range 1 - 48VDC EMC Compliant Level 3 Termination Style Screw Unit Weight 85g Factory Pack Qty 20 Datasheet Product Datasheet Notifications Please note Changes from Gen 3 to Gen 4 (current) package design here App Notes Why Use SSR's? The inside story Selecting a SSR DC Output SSR's Selecting a Suitable Heatsink Use of Thermal Interface Material How to Verify the Proper Heatsink Effect of Forced Air Cooling Fuse Protection of SSR's Overvoltage Protection "P" Option MOV SSR Reliability Whitepaper 3 Phase Motors and Heating Applications 3 Phase Motor Reversing How to test a SSR SSR Precautions SSR Life Expectancy MTBF ROHS & Reach Statement Heatsink SSR and Heatsink Assemblies
$304.00
$358.72 inclGST -
CWD24125, Solid State Relay, Single Phase 4-32VDC Control, 125A, 24-280VAC Load. High surge w/LED Indicator
Free Aus Post Shipping for $300 SpendCrydom CWD24125, Solid State Relay, Single Phase 4-32VDC Control, 125A, 24-280VAC Load. High surge w/LED Indicator Ratings from 25A to 125 Amp @ 24-280VAC SCR output for heavy industrial loads Zero voltage or instantaneous turn-on outputs UL/CSA/VDE Approved, CE Compliant to EN60950-1 Improved SEMS screw and washer Redesigned housing with anti-rotation barriers AC & DC control types Direct bond copper substrate EMC compliant to Level 3 Direct power lead frame Epoxy free design Spec Crydom Part Number CWD24125 Switching Type Zero Crossing ROHS Yes (Details) Control Voltage 4-32VDC Load Current 125 Amp (rms) Surge Capability (16.6ms) 2000 Amp (peak) Special Feature LED Status Indicator, High Surge Mounting Style Panel Mount Load Voltage Range 24-280VAC EMC Compliant Level 3 Termination Style Screw Unit Weight 75g Factory Pack Qty 20 Datasheet Product Datasheet Notifications Please note Changes from Gen 3 to Gen 4 (current) package design here Equivalent D24125 App Notes Why Use SSR's? The inside story Selecting a SSR DC Output SSR's Selecting a Suitable Heatsink Use of Thermal Interface Material How to Verify the Proper Heatsink Effect of Forced Air Cooling Fuse Protection of SSR's Overvoltage Protection "P" Option MOV SSR Reliability Whitepaper 3 Phase Motors and Heating Applications 3 Phase Motor Reversing How to test a SSR SSR Precautions SSR Life Expectancy MTBF ROHS & Reach Statement Heatsink SSR and Heatsink Assemblies
-
BS1-ND102, Digital DC Voltmeter, 48x24mm, 85-265VAC, Range : 0-1.99VDC
BS1-ND102, Digital DC Voltmeter, 48x24mm, 85-265VAC, Range : 0-1.99VDC 3.5-digit displays suit most industries including Temperature, Humidity, Pressure (0.5s response) Drip-proof / Dust-proof IP66 (front panel only) UL/CE Approved Each unit needs just 100.2 mm depth panel space EC Compliant Specification Hanyoung Nux Part Number BS1-ND102 Input 0-1.99VDC Mounting Style 48 x 24mm Panel Mount Supply Voltage 85 - 265VAC Termination Style Screw Weight 250g Factory Pack Qty 1 ROHS Yes UL Yes CE Yes Datasheet BS1 Series Instruction Manual BS1 Series Wiring and Selection Tables Free Software Hanyoung Nux TCS Software Hanyoung Nux TCS Software User Manual VX Series SB Driver (Windows 7) Not required for Windows 10 or 11
$119.00
$140.42 inclGST -
KLV3224, 440 Kvar 1kV, 1401uF, 50Hz, Single Phase Power Factor Correction Capacitor
Heavy Item - No Free ShippingKLV3224, 440 Kvar 1kV, 1401uF, 50Hz, Single Phase Power Factor Correction Capacitor Characteristics and utility 440 kVar @ 1kV @ 50 Hz 50kvar Heavy Duty 100,000Hours Single Phase Capacitor with 4 bushings Reactive power factor correction Oil Type Clamp terminals Outdoor mounting Triple safety Overpressure disconnection system Protection by internal fuses Construction and materials Low losses metallized self-healing polypropylene film, high density, high temperature and greater dielectric resistance Volt/µ UL 94 V0 Resin Side mounting brackets Standards IEC 60831-1/2 EN 60831-1/2 Specification Iskra Part Number KLV3223, 440kvar 1401uF, 50Hz, 19.053kV Technology Oil Type, Low Loss, Self Healing Dimensions 175 x 1000 x 427mm (approx) Standards IEC 60831-1/2, EN 60831-1/2 Voltage 19.053kV @ 50Hz Kvar 440 Kvar Capacitance 1401uF Insulation level 38/95kV Indoor/Outdoor Version Outdoor Tolerance On Capacitance -5% + 10% (others on request) Current (In) 440 Amp No. Of Bushings 4 Mounting Clamps Side Overpressure Disconnection System YES Self Extinguishing Resin YES Internal Fuses YES Self Healing YES Operating Temperature Range 50°C Max, 30°C Mean(1 year), 40°C Mean(24 hrs) Lifetime 100,000 Hours Terminal Style Clamp Terminals Unit Weight 91kg Factory Pack Quantity 1 Datasheet Datasheet
-
CV 3-1000 Digital Voltage Transducer Flux Gate, Vpn = 700V, +/-15VDC, 10V output, 6kV Isolation
Free Aus Post Shipping for $300 SpendLEM CV 3-1000 Digital Voltage Transducer Flux Gate, Vpn = 700V, +/-15VDC, 10V output, 6kV Isolation Features Bandwidth DC to 500kHz Closed loop transducer using Flux Gate Compact and versatile Panel Mount Insulated plastic case recognized according to UL 94-V0 Advantages Very good linearity High accuracy Low temperature drift Wide frequency bandwidth Very low insertion losses High immunity to external interference Voltage overload capability Low power consumption Applications Railway substation or locomotive High Frequency Drives AC variable speed drives and servo motor drives Static converters for DC motor drives Battery supplied applications Uninterruptible Power Supplies (UPS) Switched Mode Power Supplies (SMPS) Power supplies for welding applications Water Treatment Electronics Specification LEM Part Number CV 3-1000 Technology Closed Loop Hall Effect Aperture No Aperture ROHS Yes Supply Voltage +/-15 VDC Bipolar, Isolated Primary Nominal Voltage (RMS + DC) +/- 700V Measurement Range +/- 1000V Output 10V @Vp(max) Isolation 6 kV Bandwidth DC-500 kHz Mounting Style Panel Mount Operating Temperature Range -25°C / 75°C Accuracy 1% Termination Style M5 Screw Unit Weight 650g Factory Pack Quantity 4 Datasheet Product Datasheet
-
HD48125G-10, Solid State Relay, Single Phase 4-32VDC Control, 125A, 48-530VAC Load, Random Crossing w/ Input status LED
Free Aus Post Shipping for $300 SpendCrydom HD48125G-10, Solid State Relay, Single Phase 4-32VDC Control, 125A, 48-530VAC Load, Random Crossing w/ Input status LED Features Ratings from 25A to 125 Amp @ 48-480VAC SCR output for heavy industrial loads Zero voltage or instantaneous turn-on outputs UL/CSA/VDE Approved, CE Compliant to EN60950-1 Improved SEMS screw and washer Redesigned housing with anti-rotation barriers AC & DC control types Direct bond copper substrate EMC compliant to Level 3 Direct power lead frame Epoxy free design Spec Crydom Part Number HD48125G-10 Switching Type Random Crossing ROHS Yes (Details) Control Voltage 4-32VDC Load Current 125 Amp (rms) Surge Capability 1670 Amp (peak) Special Feature LED Status Indicator Mounting Style Panel Mount Load Voltage Range 48-530VAC EMC Compliant Level 3 Termination Style Screw Unit Weight 75g Factory Pack Qty 20 Datasheet Product Datasheet Notifications Please note Changes from Gen 3 to Gen 4 (current) package design here Equivalent See HD48125-10 for version with No status LED App Notes Why Use SSR's? The inside story Selecting a SSR DC Output SSR's Selecting a Suitable Heatsink Use of Thermal Interface Material How to Verify the Proper Heatsink Effect of Forced Air Cooling Fuse Protection of SSR's Overvoltage Protection "P" Option MOV SSR Reliability Whitepaper 3 Phase Motors and Heating Applications 3 Phase Motor Reversing How to test a SSR SSR Precautions SSR Life Expectancy MTBF ROHS & Reach Statement Heatsink SSR and Heatsink Assemblies
-
KLV3221, 200 Kvar, 5.26uF, 50Hz, 11kV, Single Phase Power Factor Correction Capacitor
Heavy Item - No Free ShippingKLV3221, 200 Kvar, 5.26uF, 50Hz, 11kV, Single Phase Power Factor Correction Capacitor Characteristics and utility 200 kVar @ 11kV @ 50 Hz 50kvar Heavy Duty 100,000Hours Singel Phase Capacitor with two bushing Reactive power factor correction Oil Type Connector type - single sided terminal Indoor mounting Safety Protection by internal fuses Self Healing Construction and materials Low losses metallized self-healing polypropylene film, high density, high temperature and greater dielectric resistance Volt/µ UL 94 V0 Resin Side & Top mounting brackets Standards IEC 60831-1/2 EN 60831-1/2 Specification Iskra Part Number KLV3221, 200 Kvar, 5.26uF, 50Hz, 11kV Technology Oil Type, Low Loss, Self Healing Dimensions 427 x 145 x 735mm Standards IEC 60831-1/2, EN 60831-1/2 Voltage 11kV @ 50Hz Max Continuous Overvoltage 1.1 x In Kvar 200 Kvar Capacitance 5.26uF Insulation level 38/95kV Indoor/Outdoor Version Outdoor Tolerance On Capacitance -5% + 10% (others on request) Current (In) 18.2 Amp No. Of Bushings 2 Mounting Clamps Side & Bottom Overpressure Disconnection System NO Self Extinguishing Resin YES Internal Fuses YES Self Healing YES Operating Temperature Range 50°C Max, 30°C Mean(1 year), 40°C Mean(24 hrs) Lifetime 100,000 Hours TerminalStyle Clamp Terminals Unit Weight 39kg Factory Pack Quantity 1 Datasheet Product Datasheet
-
Estamat PFC-12N, Power Factor Controller, 12 Step, 90-690V 50/60HZ, See Rebadged PFR-X+ 12R
Free Aus Post Shipping for $300 SpendVishay Estamat PFC-12N, Power Factor Controller, 12 Step, 90-690V 50/60HZ, See Rebadged PFR-X+ 12R & Beluk BLR-CX12R Isolated Switching of Power Factor Correction Contactors Cos ϕ Setting 0.85 to 0.95 CAP Auto CT Secondary Selection Programmable Primary CT Ratio Backlit LCD Display Various Program Combinations IP41 Up to 12 steps Measurement System - Automatic/Manual 230VAC Aux Supply Configurable Alarms Dual Password Protection Programmable Fan Control Temperature Sensing via NTC Sensor Specification Vishay Part Number Estamat PFC-12N Function Reactive Power Correction Nominal Voltage (Un) 90-690VAC Line to Line (4 Wire) Supply Voltage 90-300VAC (L-N), 15VA 45-65Hz Relay Rating 250VAC/5Amp Switch Delay Time 1s - 6500s User Adjustable Alarm 1 x Relay as above Temperature Alarm 1 x Relay as above Re-connection Delay Time 50ms - 1200s User Adjustable Desired Power Factor 0.85 IND - 1.0 CAP Number of Output Relays 14 Smallest Capacitor Current 10mA CT Input Range 0 - 6 Amp LCD Display Accuracy Voltage +/-0.5%, Frequency +/-0.1%, Power +/-1% Energy Class 1 Phase Angle Error +/- 1% at I > 3% of range Comms N/A Termination Style Screw Weight 700g Certification IEC 654-1 Factory Pack Qty 1 Material of housing PC/ABS Unflammable, according to UL 94 V-0 Enclosure protection IP40 for case, IP20 for terminals Safety According to EN 61 010-1, installation category III Pollution degree 2 Operating Temperature -20...60 °C Datasheet Product Datasheet Modbus RS485 User Manual User Manual Original Beluk User manual (with PIN code) Application Notes Discharge Resistor Usage Power Factor Correction Blog Quick Start Guide(Blog) Alternative in Stock Beluk BLR-CX12R
-
MI454, Potentiometer and Tap Position Programmable Transducer, Class 0.5, Universal 20 - 300VDC/40 to 276VAC 40 to 70Hz, Aux Voltage 57.74V,100V,230V,400V,500VAC
Free Aus Post Shipping for $300 SpendIskra Doo MI 454, Potentiometer and Tap Position Programmable Transducer, Class 0.5, Universal 20 - 300VDC/40 to 276VAC 40 to 70Hz, Aux Voltage 57.74V,100V,230V,400V,500VAC Class 0.5 (EN 60688) Programable DC Voltage Output 0-1V to 0-10V @ 20mA Programmable DC Current Output 0-1mA to 0-5mA, 0-5mA to 0-20mA @ 15V Features : Measurement of up to 500VAC Universal Supply 20 - 300VDC/40 to 276VAC 40 to 70Hz Accuracy class 0.5 Input frequency 40-70Hz Specification Iskra Doo Part Number MI454 Functions Single Phase AC Voltage Transducer Supply Voltage Self Powered Nominal Measurement Range 0-500VAC Maximum Measurement Range 0-600VAC Output 0-20mA/0-5mA Tariff Input N/A Accuracy Class 0.5 Battery Backup N/A Real Time Clock 1min/month (30ppm) Isolation 3.5kV Comms N/ Weight 340g Enclosure Material UL94 Factory Pack Qty 1 EU Directives N/A Safety Protection Class II 600V rms, installation category II 300V rms, installation category III Pollution Degree 2 in compliance with SIST EN 61010-1:2002 Enclosure Material PC/ABS non combustable-self-extinguishability, complying with UL 94 V-0 Enclosure Protection IP20 Shock Withstand 300g 8ms Pulse . 6 Shocks in each of 3 axes Vibration Withstand 0.7g, 3...100Hz, 1oct/min 10 cycles in each of three axes Operating Temperature -20 →+70 °C Datasheet Product Datasheet
-
Rish Xmer 155/80 2500/5 SCCT Class 1 45VA, Series Split Core Current Transformer
Heavy Item - No Free ShippingRishabh Xmer CT Split 155/80 2500/5 SCCT Class 1 45VA Series Split Core Current Transformer Features Quick Release Split Core System Built In Sealable Terminal Covers Mounting Feet Supplied Self Powered Rated System Voltage 0.72/3kV IEC185, BS 7626, BSEN 60044-1 and IEC 60044-1 Applications Metering Equipment Energy Monitoring AC Power Control Systems Power Factor Correction Power Quality Measurements Specification Rishabh Part Number Rish Xmer 155/80 2500/5 SCCT Class 1 45VA Technology Split Core AC Current Transformer Ratio 2500/5 Aperture Size 85 x 125mm VA Rating 45VA Accuracy Class Class 0.5 Output 5 Amp AC (+20%) Isolation 3kV (AC, 50Hz, 1 min) Bandwidth 50-60Hz Mounting Style Panel Mount/Busbar Mount Operating Temperature Range -30°C / 85°C Continuous Current (max) 2500Amp x 1.2 Termination Style Screw Unit Weight 1000g Factory Pack Qty 9 Datasheet Product Datasheet