Search results for "비대면유심개통문의 gora43430aa 소액대출50만원내구제 고라통신 선불유심 현금화 정식업체 무서류간편대출 은평구 24시 당일소액급전대출"
-
CV 4-4000/SP1 Digital Voltage Transducer, Vpn = 2800V, +/-24VDC, 10V output, 9kV Isolation
Free Aus Post Shipping for $300 SpendLEM CV 4-4000/SP1 Digital Voltage Transducer, Vpn = 2800V, +/-24VDC, 10V output, 9kV Isolation Features Bandwidth DC to 6kHz Closed loop transducer using Flux Gate Compact and versatile Panel Mount Insulated plastic case recognized according to UL 94-V0 Advantages Very good linearity High accuracy Low temperature drift Wide frequency bandwidth Very low insertion losses High immunity to external interference Voltage overload capability Low power consumption Applications Railway substation or locomotive High Frequency Drives AC variable speed drives and servo motor drives Static converters for DC motor drives Battery supplied applications Uninterruptible Power Supplies (UPS) Switched Mode Power Supplies (SMPS) Power supplies for welding applications Water Treatment Electronics Specification LEM Part Number CV 4-4000/SP1 Technology Closed Loop Hall Effect Aperture No Aperture ROHS Yes Supply Voltage +/-15 VDC Bipolar, Isolated Primary Nominal Voltage (RMS + DC) +/- 2800V Measurement Range +/- 4000V Output 10V @Vp(max) Isolation 9 kV Bandwidth DC-6 kHz Mounting Style Panel Mount Operating Temperature Range -25°C / 75°C Accuracy 0.4% Termination Style M5 Screw Unit Weight 650g Factory Pack Quantity 4 Datasheet Product Datasheet
-
DV 1000 Digital Voltage Transducer, Vpn = 1000V, +/-15...24VDC, 50mA output, 18.5kV Isolation
LEM DV 1000 Digital Voltage Transducer, Vpn = 1000V, +/-15...24VDC, 50mA output, 18.5kV Isolation Features Bandwidth DC to 12kHz Closed loop transducer using Hall effect Digital Transducer (ASIC based) Compact and versatile Panel Mount Insulated plastic case recognized according to UL 94-V0 Advantages Very good linearity High accuracy Low temperature drift Wide frequency bandwidth Very low insertion losses High immunity to external interference Voltage overload capability Low power consumption Applications Railway substation or locomotive AC variable speed drives and servo motor drives Static converters for DC motor drives Battery supplied applications Uninterruptible Power Supplies (UPS) Switched Mode Power Supplies (SMPS) Power supplies for welding applications Water Treatment Electronics Drop in replacement for LV100-2000 Specification LEM Part Number DV 1000 Technology Closed Loop Hall Effect Aperture No Aperture ROHS Yes Supply Voltage +/-15..24 VDC Bipolar, Isolated Primary Nominal Voltage (RMS + DC) +/- 1000V Measurement Range +/- 1500V Output 50 mA @Vpn Isolation 18.5 kV Bandwidth DC-13 kHz Mounting Style Panel Mount Operating Temperature Range -40°C / 85°C Accuracy 1% Termination Style M5 Screw Unit Weight 1000g Factory Pack Quantity 4 Datasheet Product Datasheet Application Notes LEM Applications Manual 3rd Edition
$1,564.00
$1,845.52 inclGST -
GX23CAB, Contactor SPST-NO, 350+ AMP, 12-800VDC, 24VDC Coil, 38cm Flying leads, SPST-NO Auxiliary Contact, IP67, IP69K
Free Aus Post Shipping for $300 SpendGigavac GX23CAB, Contactor SPST-NO, 350+ AMP, 12-800VDC, 24VDC Coil, 38cm Flying leads, SPST-NO Auxiliary Contact, IP67, IP69K Features Hermetically Sealed (Patented) rated to 175 Deg C UL1604 for Class I & II Div 2 and Class III for use in hazardous locations IP67 & IP69K SAE J1171 External ignition protection ISO8846 Protection against ignition around flammable gasses CE Approved High Efficiency Dual DC Coils - Very low 12,24,48VDC continuous coil power with no EMI emissions or cross-talk on your system control power Ideal for battery powered systems or where low power is needed PWM option provides additional drive control flexibility Built in Coils suppression for all DC Coils Flexible package for installation Chassi level power terminals Salt Fog MIL-STD-810 Specification Gigavac Part Number GX23CAB Main Contact Type SPST-NO Auxiliary Contact Type SPST-NO Coil Voltage 24VDC Load Current 350+ Amp Mechanical Life @ 0 Amp 1,000,000 Operations Dielectric at Sea Level (leakage <1mA) 2.2kV rms Control Input Terminals 38cm Flying Leads Aux Contact Terminals 38cm Flying Leads Special Feature Hermetically Seal rated to 175 Deg C Mounting Style Panel Mount (M5) Load Voltage Range 12-800VDC Standards UL1604, IP67, IP69K, SAE J1171, ISO8846 Termination Style M8 Unit Weight 580g Factory Pack Qty 1 Datasheet Product Datasheet
-
GV142FAX, Contactor SPST-NO, 400+ AMP, 12-100VDC, 48VDC Coil, 38cm Flying leads, IP67, SIDE MOUNTING
Free Aus Post Shipping for $300 SpendGigavac GV142FAX, Contactor SPST-NO, 400+ AMP, 12-100VDC, 48VDC Coil, 38cm Flying leads, IP67, SIDE MOUNTING Features Hermetically Sealed UL1604 for Class I & II Div 2 and Class III for use in hazardous locations IP67 - Temporary water immersion (30 Min) SAE J1171 External ignition protection ISO8846 Protection against ignition around flammable gasses CE Approved High Efficiency Dual DC Coils - Very low 12,24,48VDC continuous coil power with no EMI emissions or cross-talk on your system control power Ideal for battery powered systems or where low power is needed PWM option provides additional drive control flexibility Built in Coils suppression for all DC Coils Flexible package for installation Specification Giagavac Part Number GV142FAX Main Contact Type SPST-NO Auxiliary Contact Type None Coil Voltage 48VDC Load Current 400+ Amp Mechanical Life @ 0 Amp 1,000,000 Operations Dielectric at Sea Level (leakage <1mA) 2.5kV rms Control Input Terminals 38cm Flying Leads Special Feature None Mounting Style Side Panel Mount (M5) Load Voltage Range 12 - 100VDC Standards CE, UL1604, IP67, SAEJ1171 Termination Style M8 Unit Weight 450g Factory Pack Qty 1 Datasheet Product Datasheet
-
D53TP25D, Solid State Relay, 3 Phase 4-32VDC Control, 25A, 48-530VAC Load, LED Status Indicator
Free Aus Post Shipping for $300 SpendCrydom D53TP25D, Solid State Relay, 3 Phase 4-32VDC Control, 25A, 48-530VAC Load, LED Status Indicator Features Ratings from 25A to 50 Amp @ 70-480 VAC SCR output for heavy industrial loads Zero voltage or Instantaneous turn-on outputs UL/CE/ROHS Approved IP20 Cover Available AC & DC control types Direct bond copper substrate Direct power lead frame Epoxy free design Spec Crydom Part Number D53TP25D Switching Type Zero Crossing ROHS/CE/UL Yes Control Voltage 4-32VDC Load Current 25 Amp (rms) per Phase Surge Capability 239 Amp (peak) Special Feature LED Status Indicator Mounting Style Panel Mount Load Voltage Range 48-530VAC EMC Compliant Level 3 Termination Style Screw Unit Weight 315g Factory Pack Qty 10 Datasheet Product Datasheet Equivalent Contact Us for Possible Replacement App Notes Why Use SSR's? The inside story Selecting a SSR DC Output SSR's Selecting a Suitable Heatsink Use of Thermal Interface Material How to Verify the Proper Heatsink Effect of Forced Air Cooling Fuse Protection of SSR's Overvoltage Protection "P" Option MOV SSR Reliability Whitepaper 3 Phase Motors and Heating Applications 3 Phase Motor Reversing How to test a SSR SSR Precautions SSR Life Expectancy MTBF ROHS & Reach Statement Heatsink SSR and Heatsink Assemblies
-
CV 3-1500 Digital Voltage Transducer, Flux Gate, Vpn = 1000V, +/-15VDC, 10V output, 6kV Isolation
Free Aus Post Shipping for $300 SpendLEM CV 3-1500 Digital Voltage Transducer Flux Gate, Vpn = 1000V, +/-15VDC, 10V output, 6kV Isolation Features Bandwidth DC to 800kHz Closed loop transducer using Flux Gate Compact and versatile Panel Mount Insulated plastic case recognized according to UL 94-V0 Advantages Very good linearity High accuracy Low temperature drift Wide frequency bandwidth Very low insertion losses High immunity to external interference Voltage overload capability Low power consumption Applications Railway substation or locomotive High Frequency Drives AC variable speed drives and servo motor drives Static converters for DC motor drives Battery supplied applications Uninterruptible Power Supplies (UPS) Switched Mode Power Supplies (SMPS) Power supplies for welding applications Water Treatment Electronics Specification LEM Part Number CV 3-1500 Technology Closed Loop Hall Effect Aperture No Aperture ROHS Yes Supply Voltage +/-15 VDC Bipolar, Isolated Primary Nominal Voltage (RMS + DC) +/- 1000V Measurement Range +/- 1500V Output 10V @Vp(max) Isolation 6 kV Bandwidth DC-800 kHz Mounting Style Panel Mount Operating Temperature Range -25°C / 75°C Accuracy 1% Termination Style M5 Screw Unit Weight 650g Factory Pack Quantity 4 Datasheet Product Datasheet
-
GFIN/100M-DR + PMP6050WP, DIN Mount, Proportional Controller, 480-600VAC 50 Amp @ 40 Deg C, Selection for Burst/Phase Angle, 4-20mA, 0-10V, 0-5V Input, Din Rail Mount, with Overvoltage Protection
Free Aus Post Shipping for $300 SpendGFIN/100M-DR + PMP6050WP, DIN Mount, Proportional Controller, 480-600VAC 50 Amp @ 40 Deg C, Selection for Burst/Phase Angle, 4-20mA, 0-10V, 0-5V Input, Din Rail Mount, with Overvoltage Protection Selectable Proportional Phase or Burst Control Input Ratings from 25A to 90 Amp @ 170-600 VAC SCR output for heavy industrial loads Zero voltage or Instantaneous turn-on outputs UL/CE/ROHS Compliant Direct bond copper substrate Direct power lead frame Epoxy free design Specification Crydom Part Number GFIN/100M-DR + PMP6050WP Switching Type Phase Angle or Burst (Selectable) ROHS/CE/UL Yes Control Voltage 0 - 10V/0 - 5V/4 - 20mA Proportional Input (Selectable) Note Requires DC Power Supply for 0-5V/0-10V input modes Load Current 50 Amp (rms) Surge Capability 597 Amp (peak) Special Feature Proportional Controller + SSR + Overvoltage Protection Mounting Style Panel Mount Load Voltage Range 420-600VAC Dielectric Strength 4kV Termination Style Terminal Plug Unit Weight 1000g Factory Pack Qty 20 Datasheet PMP24 Series Datasheet PMP24 Installation/Wiring Guide GFIN Equivalent Parts Contact Us for Possible Replacement
-
SDM630MCT-3L-TCP, Tri 3 Phase DIN Rail Mount kWh Meter with Easyclick, 3 x 3 Phase or 9 x Single Phase, 240VAC aux, Class 1, 100mA RJ12 CT Connect, w/RS485 Modbus RTU Comms
Eastron SDM630MCT-3L-TCP, Tri 3 Phase DIN Rail Mount kWh Meter with Easyclick, 3 x 3 Phase or 9 x Single Phase, 240VAC aux, Class 1, 100mA RJ12 CT Connect, w/RS485 Modbus RTU Comms 100mA RJ12 CT 3 x 3 Phase Connect 100mA RJ12 9 x Single Phase RJ12 CT with adapter RS 485 communication up to 38,400 bit/s as standard True RMS values of currents and voltages Easyclick CT system reduces installation costs Dual Metering System Reduces Cost and saves space The meter is intended for measuring, and monitoring 3 x three phase or 9 x single-phase or electrical power network. The meter records TRMS value according to the principle of fast sampling of voltage and current signals. A built-in microprocessor calculates measurands (voltage, current, frequency, energy, power to the 30th Harmonic) from the measured signals. Features : System Accuracy Class B/Class1 Measurement of Active and Reactive Power Modbus RTU communication up to 38,400 bit/s communication Graphic LCD with illumination Specification Eastron Europe Part Number SDM630MCT-3L-TCP Functions Tri Three Phase Energy Meter/ 9 x Single Phase Energy Meter Supply Voltage 230V L-N +/-15% < 5VA Nominal Measurement Range 415V L-L 230V L-N, 1/5 Amp +/-15% Maximum Measurement Range 480V L-L 230V L-N, 1/5 Amp Nominal CT Current Input 100mA via RJ12 Easyclick CT's Pulse Output N/A Tariff Input N/A System Accuracy Class 1 (I,U,F,kW,kWh) Class 2 (Reactive) Mounting Din Rail Real Time Clock 1min/month (30ppm) Internal Memory N/A Dimensions 72mm x 100mm x 66mm (4 modules wide) Isolation 4kV RS485 2400-38400 b/s (400ms Response Time) Weight 600g Certification EN 61010-1 Installation Category III Factory Pack Qty 1 Safety IP51(Indoor) Enclosure Material Noryl with fire protection to UL94-V-O. Self extinguishing Enclosure Size DIN 42880 4 Modules Operating Temperature -20 →+70 °C Documents Product Datasheet User Manual Modbus Protocol Suitable RJ12 CT's Three Phase J12 Connected CT's Split Core Single Phase CT's for RJ12 Connected Meters Modbus Utility EEM Meter Setting Software Utility
$409.00
$482.62 inclGST -
11.212.935 AMJ5265 MAHLE - Letrika Unidirectional CW 12VDC Motor, 1.6kW, 2600rpm
Heavy Item - No free ShippingISKRA LETRIKA (MAHLE) 11.212.935 AMJ5265 MAHLE - Letrika Unidirectional CW 12VDC Motor, 1.6kW, 2600rpm MAHLE Part # MM 191 11212.958 11212958 IM0055 Specification ISKRA (MAHLE) Part Number 11.212.935 AMJ5265 MAHLE ISKRA/LETRIKA/MAHLE IM0050, 11212935, AMJ5265, MM273, 11212112, AMJ5669, 11212082, AMJ5646, 11212075, AMJ5641 Voltage 12VDC Power 1.6kW Rotation Unidirectional Clockwise Rotation Speed 2600 rpm Unit Weight 6.9kg Factory Pack Qty 1 Cross Reference FLUITRONICS (BERENDSEN) 1240247, 9000566912 LUCAS 47044608 MAHLE LETRIKA (ISKRA) IM0050, 11212935, AMJ5265, MM273, 11212112, AMJ5669, 11212082, AMJ5646, 11212075, AMJ5641 SPX FLUID POWER (FENNER) MF4034 MAKE MODEL TYPE ENGINE POWER YEARS BUCHER HYDRAULICS (HIDROIRMA) PEDRO ROQET SPX FLUID POWER (FENNER) WEBER Spare Parts Spare Parts Page
-
CV 4-6000, Digital Voltage Transducer, Vpn = 4242V, +/-15VDC, 10V output, 9kV Isolation
Free Aus Post Shipping for $300 SpendLEM CV 4-6000 Digital Voltage Transducer, Vpn = 4242V, +/-15VDC, 10V output, 9kV Isolation Features Bandwidth DC to 11kHz Closed loop transducer using Flux Gate Compact and versatile Panel Mount Insulated plastic case recognized according to UL 94-V0 Advantages Very good linearity High accuracy Low temperature drift Wide frequency bandwidth Very low insertion losses High immunity to external interference Voltage overload capability Low power consumption Applications Railway substation or locomotive High Frequency Drives AC variable speed drives and servo motor drives Static converters for DC motor drives Battery supplied applications Uninterruptible Power Supplies (UPS) Switched Mode Power Supplies (SMPS) Power supplies for welding applications Water Treatment Electronics Specification LEM Part Number CV 4-6000 Technology Closed Loop Hall Effect Aperture No Aperture ROHS Yes Supply Voltage +/-15 VDC Bipolar, Isolated Primary Nominal Voltage (RMS + DC) +/- 4242V Measurement Range +/- 6000V Output 10V @Vp(max) Isolation 9 kV Bandwidth DC-11 kHz Mounting Style Panel Mount Operating Temperature Range -25°C / 75°C Accuracy 1% Termination Style M5 Screw Unit Weight 650g Factory Pack Quantity 4 Datasheet Product Datasheet
-
PCM 30-P/SP2, Pointsenz Railway Bipolar DC Current Sensor, 30 Amp, Bipolar 4-20mA Output
Free Aus Post Shipping for $300 SpendLEM PCM 30-P/SP2 Series Closed Loop Bipolar DC Hall Effect Sensor for Point System Monitoring, Bipolar 4-20mA Output Features Closed loop sensor using Hall Effect Panel mounting Split core design for easy installation Insulated plastic case to UL 94-V0 Water resistant design rated to IP 67 Reverse polarity protected 3M screened cable connection Advantages Very good linearity Excellent accuracy Current overload capability No insertion losses. Non - contact measurement (does not need a safety case) Applications Railway equipment Points condition monitoring Signal light indication Battery supplied applications Uninterruptable Power Supplies (UPS). Specification LEM Part Number PCM 30-P/SP2 Technology Closed Loop Hall Effect ROHS Yes Supply Voltage 24V Aperture ø15.6mm Load Current (RMS + DC) 30 Amp Measuring Range +/- 60 Amp Overload Capacity (Ampere Turns) 30000 Amp Output 4-20mA Standards EN 50121-59EMC),EN 50155(temperature and humidity),EN61010-1/2 (safety) Bandwidth DC-1000Hz Mounting Style Panel Mount Operating Temperature Range -25°C / 70°C (55°C Continuous) Accuracy 0.5% Termination Style 4 Core Screened Cable 3M Unit Weight 120g Factory Pack Qty 4 Datasheet Product Datasheet Application Notes FAQ
-
G61B741, HV Relay, 30kVDC, 10A, SPST-NC, 24VDC Coil, 1,000,000 Cycles, 40kV Isolation, 12" Flying Leads
Free Aus Post Shipping for $300 SpendGigavac G61B741, HV Relay, 30kVDC, 10A, SPST-NC, 24VDC Coil, 1,000,000 Cycles, 40kV Isolation, 12" Flying Leads Features Hermetically Sealed (Patented) rated to 85 Deg C High Efficiency 3 x Form C DC Coils Gas filled Small and lightweight Flexible package for installation Specification Gigavac Part Number G61B741 Main Contact Type SPST-NC (1 Pole Normally Closed) Auxiliary Contact Type N/A Coil Voltage 24VDC Load Current 10 Amp Mechanical Life @ 0 Amp 1,000,000 Operations Impulse Withstand 30kV rms Control Input Terminals M20 Screw Mounting Style Panel Mount (M4) Load Voltage Range 40kVDC Standards UL508, NEC 690.11 and 690.12 DC Termination Style Screw Unit Weight 335g Factory Pack Qty 1 Datasheet Product Datasheet