Gigavac GV241BAC, Contactor SPST-NO, 400+ AMP, 100-800VDC, 12VDC Coil, 38cm Flying leads, IP67, SPST-NC Aux Contact
Features
Hermetically Sealed
UL1604 for Class I & II Div 2 and Class III for use in hazardous locations
IP67 - Temporary water immersion (30 Min)
SAE J1171 External ignition protection
ISO8846 Protection against ignition around flammable gasses
CE Approved
High Efficiency Dual DC Coils - Very low 12,24,48VDC continuous coil power with no EMI emissions or cross-talk on your system control power
Ideal for battery powered systems or where low power is needed
PWM option provides additional drive control flexibility
Built in Coils suppression for all DC Coils
Flexible package for installation
Specification
Gigavac Part Number
GV241BAC
Main Contact Type
SPST-NO
Auxiliary Contact Type
SPST-NC
Coil Voltage
12VDC
Load Current
400+ Amp
Mechanical Life @ 0 Amp
1,000,000 Operations
Dielectric at Sea Level (leakage <1mA)
2.5kV rms
Control Input Terminals
38cm Flying Leads
Special Feature
N/A
Mounting Style
Panel Mount (M5)
Load Voltage Range
100 - 800VDC
Standards
CE, UL1604, IP67, SAEJ1171, UL508
Termination Style
M8
Unit Weight
450g
Factory Pack Qty
1
Datasheet
Product Datasheet
Schurter FMBD-B92A-1612, 2 Stage EMC (RFI) Line Filter for 3-phase 4 wire systems, 16 Amp, 520VAC
Features
3 phase 4 wire line filter with standard attenuation
Available as high voltage filter (up to 520 VAC)
Applications
Voltage rating 520 VAC for world wide acceptance
Protection against interference voltage from the mains
For industrial applications
Suitable for use in equipment according to IEC/UL 60950
Medical Version Available
Specification
Schurter Part Number
FMBD-B92A-1612
Rated Voltage
520V
Rated Current
16A
Filter Stages
2 Stage (3 Phase)
Operating Temperature
-25°C to 100°C
Filter Type
Excellent Attenuation
Leakage Current
11.1mA
Mounting
Panel Mount
Material
Metal
Termination Style
Screw
Weight
1.2kg
Factory Pack Qty
1
Protection Class
From front side IP 40 acc. to IEC 60529
Isolation
2.2kV
VDE/UL/CSA/ROHS
Yes
Datasheet
Product Datasheet
Schurter 3-103-675, Din Rail Mount 2 Stage EMC (RFI) Line Filter, 6Amp, 250VAC, Very High Broadband Attenuation
Features
Line filter in standard and medical version
1-stage - standard attenuation
Characteristics
Designed for standard applications
Protection against interference voltage from the mains Possible interferences generated in the equipment are strongly attenuated
Universal line filter for standard applications
Suitable for use in equipment according to IEC/UL 60950
Other Versions on Request
Version with wire connection
Version with varistor for overvoltage protection
Specification
Schurter Part Number
3-103-675
Rated Voltage
250V
Rated Current
6A
Filter Stages
1 Stage
Operating Temperature
-40°C to 100°C
Filter Type
Very High Broadband Attenuation
Leakage Current
0.5mA
Mounting
DIn Rail Mount Mount - Case RI
Material
Metal
Termination Style
Screw
Weight
140g
Factory Pack Qty
10
Protection Class
Suitable for appliances with protection class I acc. to IEC 61140
Isolation
1.7kV L-N
VDE/UL/CSA/ROHS
Yes
Datasheet
Product Datasheet
Schurter 3-103-678, Din Rail Mount 2 Stage EMC (RFI) Line Filter, 16Amp, 250VAC, Very High
Features
Line filter in standard and medical version
1-stage - standard attenuation
Characteristics
Designed for standard applications
Protection against interference voltage from the mains Possible interferences generated in the equipment are strongly attenuated
Universal line filter for standard applications
Suitable for use in equipment according to IEC/UL 60950
Other Versions on Request
Version with wire connection
Version with varistor for overvoltage protection
Specification
Schurter Part Number
3-103-678
Rated Voltage
250V
Rated Current
16A
Filter Stages
1 Stage
Operating Temperature
-40°C to 100°C
Filter Type
Very High Broadband Attenuation
Leakage Current
0.5mA
Mounting
DIn Rail Mount Mount - Case RI
Material
Metal
Termination Style
Screw
Weight
140g
Factory Pack Qty
10
Protection Class
Suitable for appliances with protection class I acc. to IEC 61140
Isolation
1.7kV L-N
VDE/UL/CSA/ROHS
Yes
Datasheet
Product Datasheet
Iskra BI480-40-230VAC, Configuration_4 x SPST (4 x NO) Bistable Switch/Latching Relay with Manual Control, 440VAC, 80 Amp 230VAC Coil Voltage (Resistive)
Features
80 Amp (rms) @ 440VAC
DIN Rail Mount
Changeover Contact
Zero Power Consumption in "ON State"
Slim package
CE Compliant to IEC 60664
IP20
Specification
Fastron Part Number
BI480-40-230VAC
Switch/Latching Relay Type
4 x SPST NO
Approvals
CE
Coil Voltage
230VAC
Load Current (RMS/DC)
80 Amp (rms) @ 440VAC
Special Feature
With Manual Control
Mounting Style
DIN Rail Mount
Load Voltage Range
80 Amp (rms) @ 440VAC
Isolation
4kV
Termination Style
Screw
Unit Weight
390g
Factory Pack Qty
20
Datasheet
Relay Datasheet
Iskra IKA40-31-R-24VAC/DC, 4 Pole Configuration_SPST (1 x NC), 3 x SPST NO Modular Contactor 440VAC 40 Amp, 24VAC/DC Control Voltage, with Manual Overide
Features
40 Amp (rms) @ 440VAC
DIN Rail Mount
Changeover Contact
Slim package
CE Compliant to IEC 60664
IP20
Specification
Fastron Part Number
IKA40-31-R-24VAC
Switching Type
3 x SPST NO, Configuration_SPST (1 x NC)
Approvals
CE
Coil Voltage
24VAC/DC
Load Current (RMS/DC)
40 Amp (rms) @ 440VAC
Special Feature
Manual Overide
Mounting Style
DIN Rail Mount
Load Voltage Range
440VAC
Isolation
4kV
Termination Style
Screw
Unit Weight
295g
Factory Pack Qty
20
Datasheet
Contactor Datasheet
Iskra BI463-31-230VAC, Four Pole 3 x SPST NO Configuration_SPST (1 x NC) Bistable Switch/Latching Relay with Manual Control, 440VAC, 63 Amp 230VAC Coil Voltage (Resistive)
Features
63 Amp (rms) @ 440VAC
DIN Rail Mount
Changeover Contact
Zero Power Consumption in "ON State"
Slim package
CE Compliant to IEC 60664
IP20
Specification
Fastron Part Number
BI463-31-230VAC
Switch/Latching Relay Type
3 x SPST NO Configuration_SPST (1 x NC) 440VAC/220VDC
Approvals
CE
Coil Voltage
230VAC
Load Current (RMS/DC)
63 Amp (rms) @ 440VAC
Special Feature
With Manual Control
Mounting Style
DIN Rail Mount
Load Voltage Range
63 Amp (rms) @ 440VAC
Isolation
4kV
Termination Style
Screw
Unit Weight
195g
Factory Pack Qty
20
Datasheet
Relay Datasheet
Crouzet Automation 84872140, Single Phase Voltage Control Relay Under/Over Voltage Detection - 17.5 mm MUS, 15-600VAC/DC Measurement, 12VDC Supply, 1 x C/O Relays, 250VAC/DC @ 5 Amp
For under and over voltage monitoring of Single phase AC or DC Voltages 65 to 260V
Features:
Control of AC and DC voltages
Automatic recognition of AC/DC
Measurement ranges from 65 V to 260 V
Choice between under and over voltage
True RMS measurement
Selectable latching (memory) function
Specification
Crouzet Part Number
84872140 (Single Phase MUS Voltage Monitoring Relay With Non-Latching SPDT Contacts)
Function
Undervoltage/Overvoltage
Supply Voltage
12VDC
Measurement Voltage
1 x 15 - 600 VAC/DC
Digital Outputs
1 x C/O Relays, 250VAC/DC @ 5 Amp
Min Breaking Current
10mA/5VDC
Delay on Threshhold Crossing
0.1 → 3s (0, +10%)
Delay on Pickup
600ms
Alarm Delay on Time (max)
200ms
Reset Time
1500ms
Adjustable Hysteresis
5 - 50% of Threshhold
Maximum Measurement Cycle Time
30ms/True RMS Measurement
Measurement Accuracy
1%
Supply Voltage Range
Same as Measurement
Termination Style
Screw
Weight
170g
Certification
CE, UL, CSA, GL, ROHS
Factory Pack Qty
1
Over Voltage Category
3 in accordance with IEC/EN 60664-1
Pollution Degree
2 in accordance with IEC/EN 61131-2
Protection rating
IP40 (Front), IP20 (Rear)
Mechanical Resistance
Immunity to vibrations IEC/EN 60068-2-6, test Fc
Immunity to shock IEC/EN 60068-2-27, test Ea
Resistance to HF Interference
Immunity to radiated electrostatic fields IEC/EN 61000-4-3 Immunity to fast transients (burst immunity) IEC/EN 61000-4-4, level 3 Immunity to shock waves IEC/EN 61000-4-5 Radio frequency in common mode IEC/EN 61000-4-6, level 3 Voltage dips and breaks (AC) IEC/EN 61000-4-11 Immunity to damped oscillatory waves IEC/EN 61000-4-12
Conducted and radiated emissions
Class B (*) in accordance with EN 55022, EN 55011 (CISPR22, CISPR11) group 1 (*) Except configuration (88 970 1.1 or 88 970 1.2) + (88 970 250 or 88 970 270) + 88 970 241 class A (class B in a metal enclosure)
Operating Temperature
-20 →+70 °C except CB and XB versions in VDC : -30 →+70 °C (+40 °C in a non-ventilated enclosure) in accordance with IEC/EN 60068-2-1 and IEC/EN 60068-22
Datasheet
Product Datasheet
Iskra IKA232-20-R-230VAC, Iskra Two Pole 2 x SPST NO Modular Contactor 240VAC 32 Amp, 230VAC Control Voltage, with Manual Overide
Features
32 Amp (rms) @ 240VAC
DIN Rail Mount
Changeover Contact
Slim package
CE Compliant to IEC 60664
IP20
Specification
Fastron Part Number
IKA232-20-R-230VAC
Switching Type
2 x SPST NO
Approvals
CE
Coil Voltage
230/240VAC
Load Rating
32 Amp
Special Feature
Manual Overide
Mounting Style
DIN Rail Mount
Load Voltage Range
240VAC
Isolation
4kV
Termination Style
Screw
Unit Weight
295g
Factory Pack Qty
20
Datasheet