Fastron GPH2048ZA3, Solid State Contactor SSR, Single Phase 90-280VAC Control, 20A, 70-480VAC Load, Din Rail Mount
Ratings from 10A to 100 Amp @ 70-480 VAC
Contactor Style for retrofit
SCR output for heavy industrial loads
Zero voltage or instantaneous turn-on outputs
CE Compliant to EN60950-1
IP20
AC & DC control types
Direct bond copper substrate
EMC compliant to Level 3
Direct power lead frame
Spec
Fastron Part Number
GPH2048ZA3
Switching Type
Zero Crossing
ROHS
Yes (Details)
Control Voltage
90-280VAC
Load Current (single unit)
20 Amp (rms) @ 25 Deg C Ambient, 17 Amp (rms) @ 40 Deg C Ambient
Surge Capability
300 Amp (peak)
Special Feature
Contactor Style IP20 Terminals
Mounting Style
DIN Rail Mount
Load Voltage Range
70 - 480VAC
EMC Compliant
Level 3
Termination Style
Screw
Unit Weight
298g
Factory Pack Qty
20
Datasheet
Product Datasheet
Alternatives
SSR Style CKRA4830
App Notes
Why Use SSR's?
The inside story
Selecting a SSR
DC Output SSR's
Selecting a Suitable Heatsink
Use of Thermal Interface Material
How to Verify the Proper Heatsink
Effect of Forced Air Cooling
Fuse Protection of SSR's
Overvoltage Protection "P" Option MOV
SSR Reliability Whitepaper
3 Phase Motors and Heating Applications
3 Phase Motor Reversing
How to test a SSR
SSR Precautions
SSR Life Expectancy MTBF
ROHS & Reach Statement
Heatsink
SSR and Heatsink Assemblies
IXYS VHF28-16io5, Single Phase Half Controlled Rectifier Bridge, 32 Amp, 480VAC Line
Features
For AC or DC Variable Voltage Output Up to 15KW
Electrically insulated base plate
Industrial standard package
2500V Isolation
UL Recognized E72445
Applications
Power Supplies
Rectifier for drives applications
Rectifiers for UPS
Battery Chargers
Spec
Crydom Part Number
VHF28-16io5
AC Line voltage
480V
Device Configuration
Single Phase Half Controlled Rectifier Bridge
DC Output @ 85 Deg C
32 Amp
Package Size
W:31.7mm L:63.5mm D:19.7mm
Itsm
330 A
VF
1.6V
Tj(max)
125°C
rF
15m Ohm
Terminals
Faston (6.3mm)
Hole Centres
48.2mm (M5)
Gate Terminals
Faston (6.3mm)
R th(j-c)
1.4°C/W
R th(c-h)
2.0°C/W
Weight
50g
Isolation
2.5kV
Factory Pack Qty
20
Certification
UL Listed
IXYS Headquarters
United States
Datasheet
Product Datasheet
Alternatives
See B614F-2T or PSD51/18 for higher rated equivalent
App Notes
Why Use SSR's?
The inside story
Selecting a SSR
DC Output SSR's
Selecting a Suitable Heatsink
Use of Thermal Interface Material
How to Verify the Proper Heatsink
Effect of Forced Air Cooling
Fuse Protection of SSR's
Overvoltage Protection "P" Option MOV
SSR Reliability Whitepaper
3 Phase Motors and Heating Applications
3 Phase Motor Reversing
How to test a SSR
SSR Precautions
SSR Life Expectancy MTBF
ROHS & Reach Statement
Heatsink
SSR and Heatsink Assemblies
ST5593D, Surge Protection Device (SPD), 400VAC, Panel Mount with PE Wire, for Direct Lightning strikes
Specifications
Fastron part number
ST5593D
Category IEC / EN / VDE
Class II / Type 2 / A
Location of use
Substation
Protection modes
L/N-PE
Protective element
Back to Back Diodes
Surge discharge rating
Imax up to 200 kA
Internal protection and safety
N/A Diode fails to short or open ciruit
Standards
IEC/EN 61643-11
Crydom DC60S3-B, NORMALLY CLOSED Solid State Relay, DC 3-32VDC control, 3A, 60VDC Load
Features
Ratings from 3A to 40 Amp @ 3-60VDC
Transistor output
UL/CSA/VDE Approved, CE Compliant to EN60950-1
Improved SEMS screw and washer
Redesigned housing with anti-rotation barriers
Direct bond copper substrate
EMC compliant to Level 3
Direct power lead frame
Epoxy free design
Spec
Crydom Part Number
DC60S3-B
Switching Type
DC Load
ROHS
Yes (Details)
Control Voltage
3-32VDC
Load Current
3 Amp DC
Surge Capability (10ms)
6 Amp DC
Special Feature
Normally Closed
Mounting Style
Panel Mount
Load Voltage Range
3 - 60VDC
EMC Compliant
Level 3
Termination Style
Screw
Unit Weight
75g
Factory Pack Qty
20
Datasheet
Product Datasheet
Notifications
Please note Changes from Gen 3 to Gen 4 (current) package design here
Equivalent
See D1D40K with raised terminals (Gen 3) for alternative or DC60S7, D1D20, D1D40, D1D80 for higher current alternatives
App Notes
Why Use SSR's?
The inside story
Selecting a SSR
DC Output SSR's
Selecting a Suitable Heatsink
Use of Thermal Interface Material
How to Verify the Proper Heatsink
Effect of Forced Air Cooling
Fuse Protection of SSR's
Overvoltage Protection "P" Option MOV
SSR Reliability Whitepaper
3 Phase Motors and Heating Applications
3 Phase Motor Reversing
How to test a SSR
SSR Precautions
SSR Life Expectancy MTBF
ROHS & Reach Statement
Heatsink
SSR and Heatsink Assemblies
Fastron Electronics GT-AV(0-230)-D-1, Signal Isolator/AC Voltage Transducer, -0-230V AC input, 22-60VAC/DC aux, 4-20mA Average RMS output
Adjustable Zero and Span Setting
250mS Response Time
PC 94 UL V0
Input signals can be converted to insulated 4 to 20 mA DC output (for direct current output type)
Each unit needs just 22.5 x 114 mm depth DIN Rail cabinet space
Specification
Fastron Electronics Part Number
GT-AV(0-230)-D-1
Control Output
4-20mA Average RMS
Input
0-230VAC
Over Range
x 1.5
Operating Temperature
0 - 60°C
Load Voltage
22 - 60VDC
Span Adjustment Range
+/-10%
Zero Adjustment Range
+/-5%
Termination Style
Screw
Mounting Style
DIN Rail Mount
Case Material
PC - UL 94 V0
Weight
170g
Factory Pack Qty
1
Datasheet
Product Datasheet
Advanced Energy 8.000.006.763, Din Rail Mount Adaptor for Thyro A1A, Thyro S1S, 16 Amp and 30 Amp models only
Optional Din Rail Adaptor for Din Rail Mounting of 16 A,mp and 30 Amp THyro A1A and Thyro S1S Models
Datasheet
Product Datasheet
Iskra Doo 110VAC SQ0214 L 110V RC S2SA Synchroscope (Synchronoscope)
Measurement of phase difference between bus bar and generator
Five instruments in one (SQ 0x14)
Circular display of ∆ phase difference
Magnifield display of phase difference ∆ = ±20
Microprocessor processing
Simple synchronization conditions setting
Output relay for synchronisation (pulse or continuous)
''Dead busbar or generator'' functionality
Power supply from bus bar or generator
Standard 96x96 mm or 144x144 mm din housing
LCD with backlight for voltage, frequency and/or ∆ monitoring (SQ 0x14 only)
High immunity to EMC disturbances
Special functions set with three jumpers inside the instruments Status output
Green led for indication of both voltages
Ship version (Bureau veritas certificate - SQ 02x4)
Specification
Iskra Doo Part Number
SQ0214 L 110V RC S2SA
Function
Phase Difference (∆ϕ) Measurement
Nominal Voltage (Un)
100VAC ± 20 % Line to Line (UL-N = 400 VMAX) @ 40-70Hz
Digital Output
Relay 250 V, 1 A, 50 Hz, 250 VA
Status Output
Open-Collector 24 Vdc + 20% @30mA
Switch On Delay Time Range
0,1 ... 1 s +/-10%
Phase Difference Setting Range
2 ... 20 °el ± 3 °el
Voltage Difference Setting Range
1 ... 10 % +/-2.5%
Dead Busbar Noise Rejection Range
10%, 20%, 30% or 40%
Power Consumption
< 4VA
Short Term Overload
2 x Un for 3 seconds
LCD Display Accuracy
Voltage 1.5%, Frequency 0.5%, Phase Difference +/-3 °el
Synchronisation Accuracy
+/- 10%
Termination Style
Screw
Weight
530g
Certification
CE
Factory Pack Qty
1
Enclosure Version
Standard Version
Material of housing
PC/ABS Unflammable, according to UL 94 V-0
Enclosure protection
IP52 for case, IP20 for terminals with protective cover
Safety
According to EN 61 010-1 400 V, installation category III Pollution degree 2
Operating Temperature
-20...55 °C
Datasheet
Product Datasheet
User Manual
Application Notes & Software Downloads
The following parameters can be set via internal jumper see User Manual for more details.
Dead Busbar Generator Function
Over and Under Frequency Synchronising
Adjustable Lenght of a Sync Pulse
The following parameters Can be set via MIPack Comms Module & SQset Setting Software
Relay - 300mS/Continuous/Programmable
Dead Busbar - Active DB/Active DB + DG & % Threshold
MIPack User Manual
Download SQSet Settign Software
Fastron H31/110M + FTH6053ZA4, 3 Phase Solid State Relay, with Heatsink, 9-280VAC Control, 48-530VAC Load, IP20 Cover, Panel Mount, 34 Amps Per Phase @ 40 Deg C, with IP20 Cover
Ratings from 25 to 120 Amp @ 70-480 VAC
SCR output for heavy industrial loads
Zero voltage or Instantaneous turn-on outputs
IP20 Cover Included
AC & DC control types
Direct bond copper substrate
Direct power lead frame
Included IP20 Cover
Specification
Fastron Part Number
H31/110M + FTH6053ZA4
Switching Type
Zero Crossing
ROHS/CE/UL
Yes
Control Voltage
90-280VAC
Load Current
3 x 34 Amp (rms)
Surge Capability
597 Amp (peak)
Special Feature
LED Status Indicator, with IP20 Cover
Mounting Style
Panel Mount
Dimensions
L:110 x W:125 x D:180mm
Load Voltage Range
70-530VAC
EMC Compliant
Level 3
Termination Style
Screw
Unit Weight
2kg
Factory Pack Qty
10
Datasheet
Product Datasheet
H31 Datasheet
Equivalent Parts
Contact Us for Possible Replacement
Gigavac GV241CAC, Contactor SPST-NO, 400+ AMP, 100-800VDC, 24VDC Coil, 38cm Flying leads, SPST-NC Auxiliary Contact, IP67
Features
Hermetically Sealed
UL1604 for Class I & II Div 2 and Class III for use in hazardous locations
IP67 - Temporary water immersion (30 Min)
SAE J1171 External ignition protection
ISO8846 Protection against ignition around flammable gasses
CE Approved
High Efficiency Dual DC Coils - Very low 12,24,48VDC continuous coil power with no EMI emissions or cross-talk on your system control power
Ideal for battery powered systems or where low power is needed
PWM option provides additional drive control flexibility
Built in Coils suppression for all DC Coils
Flexible package for installation
Specification
Gigavac Part Number
GV241CAC
Main Contact Type
SPST-NO
Auxiliary Contact Type
SPST-NC
Coil Voltage
24VDC
Load Current
400+ Amp
Mechanical Life @ 0 Amp
1,000,000 Operations
Dielectric at Sea Level (leakage <1mA)
2.5kV rms
Control Input Terminals
38cm Flying Leads
Special Feature
N/A
Mounting Style
Panel Mount (M5)
Load Voltage Range
100 - 800VDC
Standards
CE, UL1604, IP67, SAEJ1171, UL508
Termination Style
M8
Unit Weight
450g
Factory Pack Qty
1
Datasheet
Product Datasheet
Fastron TC5-H-W-2-G-2, 100-240VAC PID Controller with 2 3 Amp Relay Alarms, E,J,N,T,S,R,B Thermocouple, Linear Current/Voltage and PT100/Cu20 RTD Input, 48x96mm,Relay + 12VDC Output
4-digit displays (0.5s response)
Drip-proof / Dust-proof IP66 (front panel only)
Input signals can be converted to insulated -0-10V, Relay, 12VDC (SSR) and 4 to 20 mA DC outputs available
Each unit needs just 75 mm depth panel space
Now available will full Multirange input (K,E,J,N,T,S,R,B Thermocouple, Linear Current/Voltage and PT100/Cu20 RTD Input, 96x48mm,4-20mA Output)
Specification
Fastron Part Number
TC5-H-W-2-G-2
Control Output
Relay 3A(Resistive), 1A(Inductive load cos Ѳ=0.4)/12VDC @ 20mA
Input
Multirange Type,K,E,J, Pt100, Cu50/(Optional)Linear Current 4(0)-20mA/(Optional)Linear Voltage 0-10(5)V
Option 1
2 3 Amp Relay Alarms standard (Excludes 48x96mm with SSR/Relay output)
Mounting Style
48x96mm Panel Mount
Supply Voltage
100 - 240VAC +/-10%
Termination Style
Screw
Sampling Time
100ms
Weight
150-270g
Factory Pack Qty
10
Approvals
CE
Datasheet
TC5 Datasheet and User Manual