Search results for "텔레@bitcoinsyri$`핑믹싱문화상품권테더구매"
-
LA 55-TP C/L Hall Effect Current Sensor, 50 Amp, 50mA Output, PCB Mount, No Aperture, +/-12..15V Supply, X = 0.65%
Free Aus Post Shipping for $300 SpendLEM LA 55-TP Series Closed Loop AC/DC Hall Effect Sensor Features Bandwidth DC to 200kHz Closed loop transducer using Hall effect Compact and versatile PCB Mount Insulated plastic case recognized according to UL 94-V0 Advantages Very good linearity High accuracy Low temperature drift Wide frequency bandwidth Very low insertion losses High immunity to external interference Current overload capability Low power consumption Applications AC variable speed drives and servo motor drives Static converters for DC motor drives Battery supplied applications Uninterruptible Power Supplies (UPS) Switched Mode Power Supplies (SMPS) Power supplies for welding applications Water Treatment Electronics Specification LEM Part Number LA55-TP/SP1 Technology Closed Loop Hall Effect Aperture No Aperture ROHS Yes Supply Voltage +/-12..15 VDC Bipolar, Isolated Load Current (RMS + DC) 50 Amp Measurement Range +/-70 Amp Output 50 mA Isolation 2.5 kV Bandwidth DC-200 kHz Mounting Style PCB Mount Operating Temperature Range -10°C / 85°C Accuracy 0.65% Termination Style Through Hole PCB Unit Weight 18g Factory Pack Quantity 25 Datasheet Product Datasheet Application Notes LEM Applications Manual 3rd Edition
-
HMS 20-P, O/L Hall Effect Current Sensor, 20 Amp, 5VDC Supply, PCB Mount, MOQ = 150pcs
Free Aus Post Shipping for $300 SpendLEM HMS 20-P Series Open Loop AC/DC Hall Effect Sensor Features Open loop multi-range current transducer Single supply +5 V Galvanic separation between primary and secondary circuit Low power consumption SMT PCB mounting Factory calibrated Advantages Small Size and space saving Singe paclage for wide current ranges 5 -> 20 Amp High Immunity to external interference Low offset drift Over-drivable VREF Applications AC variable speed and servo motor drives Static converters for DC motor drives Battery supplied applications Uninterruptible Power Supplies (UPS) Switched Mode Power Supplies (SMPS) Power supplies for welding applications Standards IEC 61010-1 EN50178 Application Domain Industrial Specification LEM Part Number HMS 20-P Technology Open Loop Hall Effect Aperture None ROHS Yes Supply Voltage 5 VDC Load Current (RMS + DC) 20 Amp Measurement Range +/-60 Amp Output 2W RS422 Manchester Isolation 4.3 kV Bandwidth DC-50 kHz Mounting Style PCB Mount Operating Temperature Range -40°C / 85°C Accuracy 1% Termination Style PCB Unit Weight 6g Factory Pack Quantity 25 Datasheet Product Datasheet Application Notes LEM Applications Manual 3rd Edition
-
IN 1000-S High Precision Hall Effect Current Sensor, 1000 Amp, 1000mA Output, 38.2mm Aperture, +/-15V Supply
Free Aus Post Shipping for $300 SpendIN 1000-S High Precision Hall Effect Current Sensor, 1000 Amp, 1000mA Output, 38.2mm Aperture, +/-15V Supply Features Closed loop (compensated) current transducer using an extremely accurate zero flux detector 9-pin D-Sub male secondary connector Status signal to indicate the transducer state LED indicator confirms normal operation Metal housing to improve immunity to EMC & power dissipation Operating temperature −40 °C to 85 °C. Advantages Very high accuracy Excellent linearity Extremely low temperature drift Wide frequency bandwidth High immunity to external fields No insertion losses Very low noise on output signal Low noise feedback to primary conductor. Applications Feedback element in high performance gradient amplifiers for MRI Feedback element in high-precision, high-stability power supplies Calibration unit Energy measurement Medical equipment. Standards EN 61000-6-2: 2005 EN 61000-6-3: 2007 EN 61010-1: 2010. Application Domain Industrial Laboratory Medical. Specification Insulation coordination Parameter Symbol Unit Value Comment RMS voltage for AC insulation test, 50 Hz, 1 min UdkV 4.2 Between primary and secondary + shield Impulse withstand voltage 1.2/50 μs ÛWkV 8 Clearance (pri. - sec.) dCImm 11.5 Shortest distance through air Creepage distance (pri. - sec.) dCpmm 11.9 Shortest path along device body Comparative tracking index CTI600 Rated insulation RMS voltage UNmV 1000 Basic insulation according to IEC 61010-1 CAT III, PD2 Rated insulation RMS voltage 1000 Reinforced insulation according to IEC 61010-1 CAT II, PD2 Environmental and mechanical characteristics Parameter Symbol Unit Min Typ Max Comment Ambient operating temperature TA°C −40 85 Ambient storage temperature TS°C −40 85 Relative humidity RH% 20 80 Dimensions See drawing in page 8 Mass mkg 1.3 Electrical data At TA = 25 °C, ±UC = ±15 V DC, unless otherwise noted. Lines with a * in the comment column apply over the −40 … 85 °C ambient temperature range. Parameter Symbol Unit Min Typ Max Comment Primary continuous direct current DC IP NA −1000 1000 * Primary nominal RMS current AC IP NA −1000 1000 * Peak primary current, measuring range ÎP MA −1500 1500 * Measuring resistance RMΩ 0 1 See graph page 5 for other value Secondary current nominal IS NA −0.666 0.666 * Number of secondary turns NS1500 Resistance of secondary winding RSΩ 8 Overload capability 1)ÎPkA −5 5 @ pulse of 100 ms Supply voltage DC +UCV 14.25 15 15.75 −UC−14.25 −15 −15.75 Current consumption positive DC +ICA 0.12 @ IP = 0 1.12 Current consumption positive DC −ICA 0.07 @ IP= 0 1.07 Output RMS noise current 0 … 10 Hz 2) Inoppm 0.05 0.1 Output RMS noise current 0 … 10 kHz 2)1.5 4 Output RMS noise current 0 … 160 kHz 2)3.5 10 Output peak-to-peak noise current 2)Ino ppppm 18 34 Electrical offset current + self magnetization + effect of earth magnetic field 2) IO Eppm −10 10 * Temperature coefficient of IO E@ IP = 0 A TCIO Eppm/K −0.3 0.3 Linearity error 2)εLppm −2 1 2 −3 1 3 * Step response time to 90 % of IPN DCtrµs 1 di/dt of 100 A/μs Frequency bandwidth (±1 dB) BWkHz 230 Small-signal bandwidth, 1.5 % of IP NFrequency bandwidth (±3 dB) BWkHz 440 Start-up time tstarts 15 Notes: 1) Single pulse only, not AC. The transducer may require a few seconds to return to normal operation when autoreset system is running 2) All ppm figures refer to full-scale which corresponds to a secondary nominal RMS current. Datasheet Product Datasheet
-
LAC 300-S C/L Hall Effect Current Sensor, 300 Amp, 100mA Output, 30 x 13mm Aperture, +/-15V Supply, Panel Mount, X = 0.9%
Free Aus Post Shipping for $300 SpendLEM LAC 300-S Series Closed Loop AC/DC Hall Effect Sensor Features Bandwidth DC to 50kHz Closed loop transducer using Hall effect Compact and versatile PCB Mounted with Strain Relief Insulated plastic case recognized according to UL 94-V0 Advantages Very good linearity High accuracy Low temperature drift Wide frequency bandwidth Very low insertion losses High immunity to external interference Current overload capability Low power consumption Applications AC variable speed drives and servo motor drives Static converters for DC motor drives Battery supplied applications Uninterruptible Power Supplies (UPS) Switched Mode Power Supplies (SMPS) Power supplies for welding applications Water Treatment Electronics Specification LEM Part Number LAC300-S Technology Closed Loop Hall Effect Aperture 13 x 11mm ROHS Yes Supply Voltage +/-15 VDC Bipolar, Isolated Load Current (RMS + DC) 300 Amp Measurement Range +/-700 Amp Output 100mA Isolation 5.5 kV Bandwidth DC-50 kHz Mounting Style PCB Mount Operating Temperature Range -10°C / 85°C Accuracy 0.9% Termination Style Molex series 70543-0003 Unit Weight 137g Factory Pack Quantity 25 Datasheet Product Datasheet Application Notes LEM Applications Manual 3rd Edition
-
AKR 5 B420L, Split Core AC Current Sensor, selectable 2, 5 Amp, True RMS 4-20mA output, 21.7mm sqr aperture
Free Aus Post Shipping for $300 SpendLEM AKR 5 B420L Series True RMS Solid Core AC Current Sensor with Process Outputs Compact and versatile Split Core AC current sensor, selectable 2 or 5 Amp True RMS. Choice of output types: 4-20 mA, 0-5 V or 0-10 V Features Split Core True RMS output 4-20mA current output Busbar, or panel mounting Isolated plastic case recognised according to UL94-V0 Advantages Large aperture for busbar/cable up to 21.7mm sqr High isolation between primary and secondary circuits Easy installation DIN Rail Kit available Applications -Automation Systems Analogue current reading for remote monitoring (e.g. Motor) -Data Loggers Self Powered. Will not drain data logger batteries -Panel Meters Simple connection displays power consumption Specification LEM Part Number AK 50 B420L, Technology AC Current Transformer with Process Output ROHS Yes Supply Voltage 24VDC Loop Powered Nominal Current (RMS + DC) 2, 5 Amp Selectable Maximum Measurement Current (Peak) 3.4, 10.1 Amp Output 4-20mA True RMS Aperture 21.7mm sqr Isolation 3kV (AC, 50Hz, 1 min) Bandwidth 50-60Hz Mounting Style Panel Mount Operating Temperature Range -40°C / 85°C Accuracy 1% Termination Style 2 x UNC8 Cylindric Head Unit Weight 120g Factory Pack Qty 6 Datasheet Product Datasheet Application Notes LEM Applications Manual 3rd Edition
-
Thyro S 3S Series Three Phase SCR Controller 16 - 1500Amp 400VAC +10/-15%, Phase(VAR), Burst(TAKT) Fire, SWITCH Operating Modes
Advanced Energy Thyro S 3S Series Three Phase SCR Power Controller, 16-1500Amp, 400VAC, Phase(VAR), Burst(TAKT), SWITCH Operating Modes. Compatible Replacement for Eurotherm Features 400VAC +10/-57% Line to Line Voltage, Current or Power Control Smallest footprint on the market Built in Fuses 3 Phase, Phase Angle & Burst Controller with SWITCH operation mode SWITCH between Phase(VAR) or Burst(TAKT) control modes (0)4-20mA, 0(1)-5V, 0(2)-10V or POT input Proportional Control Removable Cover USB Configuration/Bias Setting Potentiometer Adjustments Synchronisation Function for Multiple TAKT Sync Applications Electrical Ovens, Kilns, or Furnaces Primary Control of Transformer Loads in Phase or Burst Fire mode Resistive Loads up to 6:1 Hot/Cold Ratio AC Soft Starter (VAR Mode Combined with PLC) Power Regulation Applications Electric Boilers Brewery Heating Industrial Light Dimming Suitable for extreme environments such as mining Series Optional Features For HRL Current Control/Feedback Programmable Relay Alarm Output Load Monitoring Analogue Output For HRLP As above with Power Control Feedback Communication Options Standard Thyro Bus Module BasicBus Module Specification Advanced Energy Part Number Thyro S 3S 400VAC or Thyro S 3S 500VAC Approvals CE, UL508A, EU Directive 2014/35/EU & 2004/108/EC Control Accuracy 3% at rated voltage Rated Operating Temperature 45°C Temperature Derating 0.9 x Inom @ 50 Deg C, 1.1 x Inom @ 35 Deg C SCR Configuration Single Phase AC Switch Control Modes Phase(VAR), Burst(TAKT), QUick TAKT(QTM), Hybrid(VT on request) Control Input 4(0)-20mA, 0(1)-5V, 0(2)-10V, POT Load Current 16 to 1500 Amp @ 45 Deg C (110% @ 35 Deg C Max) Control Range 0-100% Options Conformal Coating for Gas or High Humidity Environments Mounting Style Panel Mount Supply Voltage Range 400VAC +10/-15% (-57% with 24VDC Aux Supply) Soft Start Via PLC input Termination Style Screw Unit Weight 2.1 to 74kg Factory Pack Qty 1 Technical Docs Brochure User Manual 2 Leg Control Application Blog Thyro A Series Quick Installtion Guide Setting Up Comms on Thyro A Series Controllers Anybus Device Ethernet IP Setup Guide
$2,154.91 - $10,967.22
-
HX 10-NP Hall Effect Current Sensor, 10 Amp, +/-4V output, no aperture, +/-15V Supply, PCB Mount, X = 1%
Free Aus Post Shipping for $300 SpendLEM HXN 10-NP Series Open Loop AC/DC Hall Effect Sensor Features Open loop current transducer Voltage output Single supply +5 V Galvanic separation between primary and secondary circuit For PCB mounting No Aperture Advantages Small size and space saving Same package for wide primary current range High immunity to external interference Fast response High insulation capability Applications AC variable speed and servo motor drives Static converters for DC motor drives Battery supplied applications Uninterruptible Power Supplies (UPS) Switched Mode Power Supplies (SMPS) Power supplies for welding applications Combiner box Solar inverter on DC side of the inverter (MPPT). Standards EN 50178: 1997 IEC 61010-1: 2010 IEC 61326-1: 2012 UL 508: 2010 Application Domain Industrial. Specification LEM Part Number HX 10-NP Technology Open Loop Hall Effect Aperture None ROHS Yes Supply Voltage 5 VDC Load Current (RMS + DC) 10 Amp Measurement Range +/-20 Amp Output 2.5 Vref Isolation 3 kV Bandwidth DC-50 kHz Mounting Style PCB Mount Operating Temperature Range -40°C / 105°C Accuracy 1.35% Termination Style PCB Through Hole Unit Weight 8g Factory Pack Quantity 25 Datasheet Product Datasheet Application Notes LEM Applications Manual 3rd Edition
-
LA 150-TP/SP1, C/L Hall Effect Current Sensor, 100 Amp, 75mA Out, No Aperture, X = 0.5%, PCB Mount
Free Aus Post Shipping for $300 SpendLEM LA 150-TP/SP1 Closed Loop AC/DC Hall Effect Sensor Features Bandwidth DC to 150kHz Closed loop transducer using Hall effect Compact and versatile PCB Mounted with Strain Relief Insulated plastic case recognized according to UL 94-V0 Advantages Very good linearity High accuracy Low temperature drift Wide frequency bandwidth Very low insertion losses High immunity to external interference Current overload capability Low power consumption Applications AC variable speed drives and servo motor drives Static converters for DC motor drives Battery supplied applications Uninterruptible Power Supplies (UPS) Switched Mode Power Supplies (SMPS) Power supplies for welding applications Water Treatment Electronics Specification LEM Part Number LA150-TP/SP1 Technology Closed Loop Hall Effect Aperture No Aperture ROHS Yes Supply Voltage +/-12..15 VDC Bipolar, Isolated Load Current (RMS + DC) 150 Amp Measurement Range +/-212 Amp Output 75mA Isolation 5 kV Bandwidth DC-150 kHz Mounting Style PCB Mount Operating Temperature Range -10°C / 85°C Accuracy 0.5% Termination Style Through Hole PCB Unit Weight 35g Factory Pack Quantity 10 Datasheet Product Datasheet Application Notes LEM Applications Manual 3rd Edition
-
HASS 400-S O/L Hall Effect Current Sensor, Panel Mount, 400 Amp, 5 VDC Supply, 2.5 Vref Output, PCB Mount 10.4 x 20.4mm sqr
Free Aus Post Shipping for $300 SpendLEM HASS 400-S Series Open Loop AC/DC Hall Effect Sensor Features 5VDC Unipolar Supply Bandwidth DC to 50kHz Open loop transducer using Hall effect Compact and versatile Panel mounting-Horizontal or Vertical Insulated plastic case recognized according to UL 94-V0 Advantages Very good linearity Very good accuracy Low temperature drift Wide frequency bandwidth Very low insertion losses High immunity to external interference Current overload capability Low power consumption Wide dynamic range, 50 to 600 A in one package. Applications AC variable speed drives and servo motor drives Static converters for DC motor drives Battery supplied applications Uninterruptible Power Supplies (UPS) Switched Mode Power Supplies (SMPS) Power supplies for welding applications. Specification LEM Part Number HASS 400-S Technology Open Loop Hall Effect Aperture 20.4 x 10.4mm Square ROHS Yes Supply Voltage 5 VDC Load Current (RMS + DC) 400 Amp Measurement Range +/-900 Amp Output 2.5 Vref Isolation 3.3 kV Bandwidth DC-50 kHz Mounting Style Panel Mount Operating Temperature Range -40°C / 85°C Accuracy 1% Termination Style Molex 5045-04A Unit Weight 60g Factory Pack Quantity 10 Datasheet Product Datasheet Application Notes LEM Applications Manual 3rd Edition
-
ITZ 2000-S FLEX ULTRASTAB High Precision Hall Effect Current Sensor, 2000 Amp peak, 1000mA Output, 50mm Aperture, 100-240VAC Supply
Heavy item - No Free ShippingITZ 2000-S FLEX ULTRASTAB High Precision Hall Effect Current Sensor, 2000 Amp peak, 1000mA Output, 50mm Aperture, 100-240VAC Supply Datasheet Product Datasheet
-
LF 305-S C/L Hall Effect Current Sensor, 300 Amp, 150mA Output, 20.1mm Aperture, +/-15..24V Supply, Panel Mount, X = 0.5%
Free Aus Post Shipping for $300 SpendLEM LF 305-S Series Open Loop AC/DC Hall Effect Sensor Features Bipolar and insulated current measurement up tp 500 Amp Current output Bandwidth DC to 100kHz Closed loop (compensated) current transducer Panel mounting Insulated plastic case recognized according to UL 94-V0 Advantages Very good linearity High accuracy Low offset drift over temperature Wide frequency bandwidth Very low insertion losses High immunity to external interference Current overload capability Low power consumption Applications Windmill Inverters Test and Measurement Substations AC variable speed drives and servo motor drives Static converters for DC motor drives Battery supplied applications Uninterruptible Power Supplies (UPS) Switched Mode Power Supplies (SMPS) Power supplies for welding applications Application Domain Industrial Standards EN 50178:1997 IEC61010-1:2010 UL 508:2010 Specification LEM Part Number LF 305-S Technology Closed Loop Hall Effect Aperture ø20.1mm ROHS Yes Supply Voltage +/- 12 VDC to +/- 20 VDC Bipolar, Isolated Load Current (RMS + DC) 300 Amp Measurement Range +/- 500 Amp Output 150 mA Isolation 3.8 kV Bandwidth DC-100 kHz Mounting Style Panel Mount Operating Temperature Range -10°C / 85°C Accuracy 0.5% Termination Style Molex 5054-03/AG Unit Weight 95g Factory Pack Quantity 60 Datasheet Product Datasheet Application Notes LEM Applications Manual 3rd Edition
-
HXN 05-P Hall Effect Current Sensor, 5 Amp, +/-4V output, no aperture, +/-15V Supply, PCB Mount, X = 1%
Free Aus Post Shipping for $300 SpendLEM HXN 05-P Series Open Loop AC/DC Hall Effect Sensor Features Open loop current transducer Voltage output Single supply +5 V Galvanic separation between primary and secondary circuit For PCB mounting No Aperture Advantages Small size and space saving Same package for wide primary current range High immunity to external interference Fast response High insulation capability Applications AC variable speed and servo motor drives Static converters for DC motor drives Battery supplied applications Uninterruptible Power Supplies (UPS) Switched Mode Power Supplies (SMPS) Power supplies for welding applications Combiner box Solar inverter on DC side of the inverter (MPPT). Standards EN 50178: 1997 IEC 61010-1: 2010 IEC 61326-1: 2012 UL 508: 2010 Application Domain Industrial. Specification LEM Part Number HXN 05-P Technology Open Loop Hall Effect Aperture None ROHS Yes Supply Voltage 5 VDC Load Current (RMS + DC) 5 Amp Measurement Range +/-15 Amp Output 2.5 Vref Isolation 3 kV Bandwidth DC-50 kHz Mounting Style PCB Mount Operating Temperature Range -40°C / 105°C Accuracy 1.35% Termination Style PCB Through Hole Unit Weight 8g Factory Pack Quantity 25 Datasheet Product Datasheet Application Notes LEM Applications Manual 3rd Edition