Search results for "가전제품렌탈내구제 탤ㄺ램 banonpi 기대출연체자소액대출 바넌피선불유심내구제 목포시 무직자백수 소액급전 작업대출 안전비대면소액급전문의"
-
MCT 250/5 Class 0.5 5VA 50-30 (30), Series Current Transformer, Revenue Grade
Secure MCT 250/5 Class 0.5 5VA 50-30 (30), Series Current Transformer, Revenue Grade Features DIN Rail Mounting Clip Included Built In Sealable Terminal Covers Mounting Feet Supplied Narrow Width (45mm) Self Powered Rated System Voltage 0.72/3kV IEC185, BS 7626, BSEN 60044-1 and IEC 60044-1 Applications Metering Equipment Energy Monitoring AC Power Control Systems Power Factor Correction Power Quality Measurements Specification Secure Part Number MCT 250/5 Class 0.5 5VA 50-30 (30) Technology AC Current Transformer Ratio 250/5 Aperture Size ⌀ 26mm or 34x10mm Busbar VA Rating 5VA Accuracy Class Class 0.5 Output 5 Amp AC (+20%) Isolation 3kV (AC, 50Hz, 1 min) Bandwidth 50-60Hz Mounting Style Panel Mount/Din Rail Mount Operating Temperature Range -30°C / 85°C Continuous Current (max) Ipn x 1.2 Termination Style Screw Certifications CE / ILAC Certified for Billing Unit Weight 300g Factory Pack Qty 9 Datasheet Product Datasheet
$109.00
$128.62 inclGST -
FBT Y PVM 1500 RM, 1500VDC Surge Protection Device for Photovoltaic Systems, Type 2 (Class II) 40kA WITH REMOTE C/O CONTACTS
FBT Y PVM 1500 RM, 1500VDC Surge Protection Device for Photovoltaic Systems, Type 2 (Class II) 40kA WITH REMOTE C/O CONTACTS Specifications Trent part number FBT Y PVM 1500 RM Nominal Voltage 1500VDC No of Poles 3 Category IEC / EN / VDE Type 2 (Class II) Location of use String Box, Inverter Protection modes (+)-PE,(-)-PE,(+)-(-) PE Additional Remote Contacts YES NO/NC/COM Protective element MOV No Fault/Fault Indication Green Flag / Not Green Flag Surge discharge rating Per pole 40kA (8/20uS)9KA) Max, 20kA (8/20uS)9KA) Nominal Internal protection and safety Thermal disconnector in each MOV Weight 420g Standards IEC50539-11 (TUV Approved) Datasheet Product Datasheet GDT/MOV/TVS Tester SPD Tester
$149.00
$175.82 inclGST -
DR2260A20V, Solid State Contactor SSR, Single Phase 90-280VAC Control, 20A, 48-600VAC Load, Din Rail Mount
Free Aus Post Shipping for $300 SpendCrydom DR2260A20V, Solid State Contactor SSR, Single Phase 90-280VAC Control, 20A, 48-600VAC Load, Din Rail Mount Features Ratings from 20A to 35 Amp @ 48-660 VAC Contactor Style for retrofit SCR output for heavy industrial loads Zero voltage or instantaneous turn-on outputs UL/CSA/VDE Approved, CE Compliant to EN60950-1 Improved SEMS screw and washer Redesigned housing with anti-rotation barriers AC & DC control types Direct bond copper substrate EMC compliant to Level 3 Direct power lead frame Epoxy free design Spec Crydom Part Number DR2260A20V Switching Type Zero Crossing ROHS Yes (Details) Control Voltage 90-280VAC Load Current (single unit) 20 Amp (rms) @ 40 Deg C Ambient, 16 Amp (rms) @ 50 Deg C Ambient Load Current (multiple units) 20 Amp (rms) @ 40 Deg C Ambient, 16 Amp (rms) @ 50 Deg C Ambient Surge Capability 286 Amp (peak) Special Feature Contactor Style Terminals Mounting Style DIN Rail Mount Load Voltage Range 48 - 660VAC EMC Compliant Level 3 Termination Style Screw Unit Weight 298g Factory Pack Qty 20 Datasheet Product Datasheet Alternatives SSR Style CKRD4830 App Notes Why Use SSR's? The inside story Selecting a SSR DC Output SSR's Selecting a Suitable Heatsink Use of Thermal Interface Material How to Verify the Proper Heatsink Effect of Forced Air Cooling Fuse Protection of SSR's Overvoltage Protection "P" Option MOV SSR Reliability Whitepaper 3 Phase Motors and Heating Applications 3 Phase Motor Reversing How to test a SSR SSR Precautions SSR Life Expectancy MTBF ROHS & Reach Statement Heatsink SSR and Heatsink Assemblies
-
DCBM LEM DC kWh Meter, Class B, DIN Rail Mount, 1000VDC, with 400 or 600 Amp Shunt, IP Enabled, OCMF, DHCP Protocols, PTB Approved for Billing Purposes
Free Aus Post Shipping for $300 SpendDCBM LEM DC kWh Meter, Class B, DIN Rail Mount, 1000VDC, with 400 or 600 Amp Shunt, IP Enabled, OCMF, DHCP Protocols. PTB Germany Approved, or MID Approved for Billing 0-400/600 Amp Shunt Measurement Options (Included) Bi-Directional DC Measurement Voltage Measurement Range 150V to 1150V Backlit LCD 12VDC to 24VDC Supply Voltage Meter Operating Temperature -25°C to 70°C Sensor Operating temperature -40°C to 85°C Busbar Operating temperature 105°C max IP Enabled with DHCP 12 - 24VDC Supply Accuracy Class B The meter is intended for measuring, and monitoring DC electrical power and in particular EV charger networks. The meter records DC power according to the principle of fast sampling of voltage and current signals and is approved for billing purposes. A built-in microprocessor calculates measurands. Features : Measurement of DC kWh Power Graphic LCD with illumination Specification LEM Part Number DCBM400, DCBM600 Functions DC Energy Meter Supply Voltage 12-24VDC Nominal Measurement Range 150VDC to 1000VDC Maximum Measurement Range 150 - 1150VDC Nominal Current Input Shunt Provided IP Conficguration Fixed or DHCP Accuracy Class B Mounting Din Rail Mount Real Time Clock NTP Time Sync over HTTPS/REST Dimensions 96 x 96 x 82mm (2 DIN) Pulse Output Optional Isolation 1000VDC Reinforced (4.4kV Vrms Isolation test), PD2, OVC2, Impulse Withstand Voltage 1.2/50uS at 8kV, Altitude = 2000m Comms HTTPS/REST, Ethernet IP, OCMF/SAFE Signed Data Weight 5/6kg Certification PTB, VDE-AR-E-2418-3-100 Factory Pack Qty 1 Enclosure Material PC/ABS non combustable-self-extinguishability, complying with UL 94 V-0 Enclosure Protection IP20 Operating Temperature -25 →+70°C (Meter), -40 →+85 °C (Busbar 105°C ) Datasheet Product Datasheet Leaflet