Fastron Electronics GTD-DAO(0-1)-D-11, Signal Conditioner/Current Transducer, 0-1 Amp AC input, 22-60VAC/DC aux, Dual 4-20mA Average RMS outputs
Adjustable Zero and Span Setting
250mS Response Time
PC 94 UL V0
Input signals can be converted to insulated 4 to 20 mA DC output (for direct current output type)
Each unit needs just 22.5 x 114 mm depth DIN Rail cabinet space
Specification
Fastron Electronics Part Number
GTD-DAO(0-1)-A-11
Conditioned Output
2 x 4-20mA (Average RMS)
Input
0 -1 Amp RMS
Over Range
x 1.5
Operating Temperature
0 - 60°C
Load Voltage
22-60VAC/DC
Span Adjustment Range
+/-10%
Zero Adjustment Range
+/-5%
Termination Style
Screw
Mounting Style
DIN Rail Mount
Case Material
PC - UL 94 V0
Weight
170g
Factory Pack Qty
1
Datasheet
Product Datasheet
Crydom DR2260A35V, Solid State Contactor SSR, Single Phase 90-280VAC Control, 35A, 48-600VAC Load, Din Rail Mount
Features
Ratings from 20A to 35 Amp @ 48-660 VAC
Contactor Style for retrofit
SCR output for heavy industrial loads
Zero voltage or instantaneous turn-on outputs
UL/CSA/VDE Approved, CE Compliant to EN60950-1
Improved SEMS screw and washer
Redesigned housing with anti-rotation barriers
AC & DC control types
Direct bond copper substrate
EMC compliant to Level 3
Direct power lead frame
Epoxy free design
Spec
Crydom Part Number
DR2260A35V
Switching Type
Zero Crossing
ROHS
Yes (Details)
Control Voltage
90-280VAC
Load Current (single unit)
35 Amp (rms) @ 40 Deg C Ambient, 30 Amp (rms) @ 50 Deg C Ambient
Load Current (multiple units)
25 Amp (rms) @ 40 Deg C Ambient, 20 Amp (rms) @ 50 Deg C Ambient
Surge Capability
1290 Amp (peak)
Special Feature
Contactor Style Terminals
Mounting Style
DIN Rail Mount
Load Voltage Range
48 - 660VAC
EMC Compliant
Level 3
Termination Style
Screw
Unit Weight
298g
Factory Pack Qty
20
Datasheet
Product Datasheet
Alternatives
SSR Style CKRD4830
App Notes
Why Use SSR's?
The inside story
Selecting a SSR
DC Output SSR's
Selecting a Suitable Heatsink
Use of Thermal Interface Material
How to Verify the Proper Heatsink
Effect of Forced Air Cooling
Fuse Protection of SSR's
Overvoltage Protection "P" Option MOV
SSR Reliability Whitepaper
3 Phase Motors and Heating Applications
3 Phase Motor Reversing
How to test a SSR
SSR Precautions
SSR Life Expectancy MTBF
ROHS & Reach Statement
Heatsink
SSR and Heatsink Assemblies
DC-0-5-420-1.0, Hall Effect DC Current Transducer, 0-5 Amp DC, 4-20mA Unipolar output, 24VDC supply
Compact and versatile Split Core DC current sensor, 0-5 Amp DC, 4-20 mA Unipolar Output
Other measurement ranges available on request
Features
⌀20mm Aperture
DC Unipolar Measurement
4-20mA analogue output
Busbar, or DIN Rail Mounting
Isolated plastic case recognised according to UL94-V0
Advantages
High isolation between primary and secondary circuits
Easy installation
DIN Rail Kit available
Applications
-Automation Systems
Analogue current reading for remote monitoring (e.g. Motor)
-Data Loggers
Self Powered. Will not drain data logger batteries
-Panel Meters
Simple connection displays power consumption
Specification
Fastron Part Number
DC-0-5-420-1.0
Technology
DC Hall Current Sensor with Process Output
ROHS
Yes
Supply Voltage
24VDC
Nominal Current (DC)
0-5 Amp
Response Time
< 1uS
Output
Unipolar 4-20mA
Isolation
2.5kV (AC, 50Hz, 1 min)
Bandwidth
DC
Mounting Style
DIN Rail Mount
Operating Temperature Range
-40°C / 85°C
Accuracy
1%
Termination Style
Elevator Terminals
Unit Weight
120g
Factory Pack Qty
6
Datasheet
Product Datasheet
Fastron F157FT 2PL 8A 24VDC + F157F-2Z-C3, Relay, DPDT 8 Amp Form C, 250VAC/30VDC Load, 24VDC Coil
Features
2 x SPDT 8 Amp @ 250VAC or 30VDC
DIN Rail Mount
Changeover Contact
Slim package
Compatible with Omron G2R-1-S Series
UL Approved
CE Compliant to IEC 60664
IP20
Suits F157F-1Z-C3 socket
Specification
Fastron Part Number
F157FT 2PL 8A 24VDC + F157F-1Z-C3
Switching Type
DPDT 30VDC/250VAC C/O Form C
Approvals
UL, CE
Coil Voltage
230VAC
Load Current
2 x 8 Amp (rms)
Special Feature
LED Status Indicator
Mounting Style
DIN Rail Mount
Load Voltage Range
0-250VAC, 0-30VDC
Isolation
2.5kV
Termination Style
PCB or Socket Mount
Unit Weight
60g
Factory Pack Qty
20
Datasheet
Relay Datasheet
Socket Replacement
F157F-1Z-C3
Relay Replacement
F157FT1PL 12A 24VDC
Fastron F157FT 2PL 8A 240VAC F157F-2Z-C3, Relay, DPDT 8 Amp Form C, 250VAC/30VDC Load, 240VAC Coil
Features
2 x 8 Amp @ 250VAC or 30VDC
DIN Rail Mount
Changeover Contact
Slim package
Compatible with Omron G2R-1-S Series
UL Approved
CE Compliant to IEC 60664
IP20
Suits F157F-1Z-C3 socket
Specification
Fastron Part Number
F157FT 2PL 8A 240VAC F157F-2Z-C3
Switching Type
DPDT 30VDC/250VAC C/O Form C
Approvals
UL, CE
Coil Voltage
240VAC
Load Current
2 x 8 Amp (rms)
Special Feature
LED Status Indicator
Mounting Style
DIN Rail Mount
Load Voltage Range
0-250VAC, 0-30VDC
Isolation
2.5kV
Termination Style
PCB or Socket Mount
Unit Weight
60g
Factory Pack Qty
20
??
Datasheet
Relay Datasheet
Socket Replacement
F157F-1Z-C3
Relay Replacement
F157FT-1PL 12A 240VAC
MBL43, Mechanical interlock for KNL80 to KNL110 Contactors
Features
Snap on
Safety interlock prevents contactor from turning on during maintenance
For Iskra KNL43 to KNL110 Contactors
RCS-1800-0400 Three-Phase Flexible Current Sensor System (Rogowski Coils):
The RCS-1800 three-phase flexible rope CT from Magnelab converts AC input current of up to 5000 amperes to an AC output of 0.333 volt.
A 9 to 36 VDC power supply is required to operate these coils. The RCS-1800 comes with an integrator which includes flexible strain relief cables.
Included is an 12 inch circumference rope CT with Integrator, and 8 feet of twisted pair (600V) output leads.
Magnelab Coils come with 10 year warranty
Suitable Alternative to Solar Edge CTRC-07500-0400
Specification
Magnelab Part Number
RCS-1800-0400
Function
AC Current Measurement
Nominal Measurement Current (Ipn)
400 Amp RMS
Measurement Range
10% - 130% if Ipn
Frequency Measuring Range
50-1500Hz (15th Harmonic)
Operating Voltage
9 - 36VDC
Accuracy
1% from 25 to 500 Amp
Phase Angle
< 0.5 Degrees
Coil Diameter (⌀)
6 Inch
Coil Circumference
18 Inch
Integrator to Coil Cable
8 Feet Shielded
Maximum Voltage
600V (on bare conductor)
Operating Temperature
-15°C to 65°C
Storage Temperature
-45°C to 80°C
Power Consumption
< 2VA
Overload
20,000 Amp (continuous)
Termination Style
Screw
Weight
1200g
Certification
CE
Factory Pack Qty
1
Certifications
UL Recognized E96927 to IEEE C57.13, CAN/CSA 60044-1
Meets UL STD 61010-1, CAN/CSA C22.2 No. 61010
CE
ROHS
Datasheet
Product Datasheet
Application Notes
RCS/RCT Series Installation Guide
Iskra BI463-2C-230VAC, Four Pole 2 x SPDT CO Bistable Switch/Latching Relay with Manual Control, 440VAC, 63 Amp 230VAC Coil Voltage (Resistive)
Features
63 Amp (rms) @ 440VAC
DIN Rail Mount
Changeover Contact
Zero Power Consumption in "ON State"
Slim package
CE Compliant to IEC 60664
IP20
Specification
Fastron Part Number
BI463-2C-230VAC
Switch/Latching Relay Type
2 x SPDT CO 440VAC/220VDC
Approvals
CE
Coil Voltage
230VAC
Load Current (RMS/DC)
63 Amp (rms) @ 440VAC
Special Feature
With Manual Control
Mounting Style
DIN Rail Mount
Load Voltage Range
63 Amp (rms) @ 440VAC
Isolation
4kV
Termination Style
Screw
Unit Weight
195g
Factory Pack Qty
20
Datasheet
Relay Datasheet
Fastron F1D40-220, Solid State Relay, DC 3.5-32VDC control, 40A, 20-220VDC Load
Features
Ratings from 7A to 100 Amp @ 1-480VDC
Mosfet output for reliable DC switching
Multiple modules can be wired in parallel for higher currents
UL/CSA/VDE Approved, CE Compliant to EN60950-1
Improved SEMS screw and washer
Redesigned housing with anti-rotation barriers
Direct bond copper substrate
EMC compliant to Level 3
Direct power lead frame
Epoxy free design
Spec
Fastron Part Number
F1D40-220
Switching Type
DC Load
Control Voltage
3.5-32VDC
Load Current
40 Amp DC
Surge Capability (10ms)
100 Amp DC
Special Feature
LED Indicator
Mounting Style
Panel Mount
Load Voltage Range
20 - 220VDC
EMC Compliant
Level 3
Termination Style
Screw
Unit Weight
75g
Factory Pack Qty
20
Datasheet
Product Datasheet
Equivalent
See alternative D1D40K with raised terminals for alternative or D1D80 for higher current alternative
App Notes
Why Use SSR's?
The inside story
Selecting a SSR
DC Output SSR's
Selecting a Suitable Heatsink
Use of Thermal Interface Material
How to Verify the Proper Heatsink
Effect of Forced Air Cooling
Fuse Protection of SSR's
Overvoltage Protection "P" Option MOV
SSR Reliability Whitepaper
3 Phase Motors and Heating Applications
3 Phase Motor Reversing
How to test a SSR
SSR Precautions
SSR Life Expectancy MTBF
ROHS & Reach Statement
Heatsink
SSR and Heatsink Assemblies
Iskra Doo RI61J C 50-10kA, 1 Pole DC Miniature Circuit Breaker Disconnect Switch C Curve 50 Amp, 220VDC, 10kA
Miniature Circuit Breakers are used for over-current (overload and short-circuit) protection of installations and devices, and as a disconnector in case of electric shock
Features :
< 50mS Trip Delay Time
1 Pole Disconnect
10kA Short Circuit Rating
Suitable for Isolation
Customised versions available
Type B, C, D Curve available
Standards :
IEC/EN 60898,60947-3
IP20 (IP40 Installed) IEC 61008
Specification
Iskra Doo Part Number
RI61J C50
Functions
1 Pole MCB - C Curve
Nominal Voltage
220VDC
Nominal Current Range
50 Amp RMS
Trip Delay Time
< 50ms
Rated Frequency
50/60 Hz
Operating Temperature
-25 to 55 Deg C
Rated Operations
10,000 Ops
Surge Current
220V
Short Circuit Current
10kA
Approvals
VDE, GOST-R
Standards
IEC/EN 60898,60947-1/2, IP20 (IP40 Installed) IEC 61008 ;
Weight
130g
Enclosure Material
UL94
Factory Pack Qty
1
Datasheet
Product Datasheet