Search results for "텔레@coinsp24^^소액결제세탁trc20사는법"
-
Thyro-ECO-A2A-400-25 E L3, Thyro-A-2A-ECO Series 2 Leg 3 Phase Burst(TAKT) Controller 25 Amp Rating, Voltage Control only, Most Economical Configuration, Suitable for Transformer Loads and Resistive Loads with 6:1-Hot Cold Ratio
Advanced Energy Thyro-ECO-A2A-400-25 E L3, Thyro-A-2A-ECO Series 2 Leg 3 Phase Burst(TAKT) Controller 25 Amp Rating, Voltage Control only, Most Economical Configuration, Suitable for Transformer Loads and Resistive Loads with 6:1-Hot Cold Ratio Features 230VAC +10/-57% Voltage Control Smallest footprint on the market 3 Phase, Phase Angle & Burst Controller with SWITCH operation mode SWITCH between Phase(VAR) or Burst(TAKT) control modes (0)4-20mA, 0(1)-5V, 0(2)-10V or POT input Proportional Control Fully enclosed IP20 Phase Angle(VAR), and Burst Fire(TAKT) switching Removable Cover USB Configuration/Bias Setting Synchronisation Function Digital Alarm Output Load Monitoring Applications Electrical Ovens, Kilns, or Furnaces Primary Control of Transformer Loads in Phase or Burst Fire mode AC Soft Starter (Combined with PLC) Power Regulation Applications Electric Boilers Brewery Heating Industrial Light Dimming Suitable for extreme environments such as mining Special Features Economic Model Specification Advanced Energy Part Number Thyro-ECO-A2A-400-25 E L3 Approvals CE, UL508A, EU Directive 2014/35/EU & 2004/108/EC Control Accuracy 3% at rated voltage Rated Operating Temperature 45°C SCR Configuration 3 Phase AC Switch Control Input 4(0)-20mA, 0(1)-5V, 0(2)-10V, POT Load Current 25 to 125 Amp @ 45 Deg C (110% @ 35 Deg C Max) Control Range 0-100% Options Conformal Coating for Gas or High Humidity Environments Mounting Style Panel Mount Supply Voltage Range 400VAC +10/-57% (-57% 24VDC Aux) Soft Start Via PLC input Termination Style Screw Unit Weight 2.1 to 10kg Factory Pack Qty 1 Technical Docs Brochure User Manual 2 Leg Control Application Blog Thyro A Series Quick Installtion Guide Setting Up Comms on Thyro A Series Controllers Anybus Device Ethernet IP Setup Guide
$1,795.86
$2,119.11 inclGST -
88886516, Syr-Line Multirange Timer TMR 48 X, 11 Pin, Single Pole 5A CO (SPDT) Delay 0.02s - 300h, 12-240VDC, 24-240VAC, 48x48mm, Functions L, Li, G, Gi
Free Aus Post Shipping for $300 SpendCrouzet 88886516, Syr-Line Multirange Timer TMR 48 X, 11 Pin, Single Pole 5A CO (SPDT) Delay 0.02s - 300h, 12-240VDC, 24-240VAC, 48x48mm, Functions L, Li, G, Gi TMR 48 X Timers Syrline 48x48mm - 1 Relay 5A : Multi-Function Multi-range (0.02 s – 300 h) Multi-voltage (12-240VDC/24-240 V AC) 2 x CO relay outputs (Changeover) DIN Sized (48x48 mm) Housing Compact body (64.5 mm long) Water & Dust-proof (IP50) 11-Pin Multifunction Timers Include The Following : L, Li, G, Gi Specification Crouzet Part Number 88886516 Function Multifunction Timer L, Li, G, Gi Nominal Voltage 12 - 240VDC / 24 → 240 VAC Digital Output 2 x C/O (SPDT) (Changeover -Single Pole Double Throw), 250VAC/DC @ 5 Amp Min Breaking Current 10mA/12VDC Timing Ranges Selectable 0.02→300h Minimum Pulse Duration 30ms/100ms with load Repeatability 0.5% Reset Time 120ms Memory N/A Isolation 1kV Repetition Accuracy 0.5% Threshold Adjustment Range 10 → 100 % of the range Termination Style 11 Pin Base Weight 80g Certification CE, cULus,CCC, ROHS, Reach, WEEE Factory Pack Qty 1 Over Voltage Category 3 in accordance with IEC/EN 60664-1 Pollution Degree 2 in accordance with IEC/EN 61131-2 Protection rating IP50 (Front), IP40 (Rear) Mechanical Resistance Immunity to vibrations IEC/EN 60068-2-6, test Fc Immunity to shock IEC/EN 60068-2-27, test Ea Resistance to HF Interference Immunity to radiated electrostatic fields IEC/EN 61000-4-3 Immunity to fast transients (burst immunity) IEC/EN 61000-4-4, level 3 Immunity to shock waves IEC/EN 61000-4-5 Radio frequency in common mode IEC/EN 61000-4-6, level 3 Voltage dips and breaks (AC) IEC/EN 61000-4-11 Immunity to damped oscillatory waves IEC/EN 61000-4-12 Conducted and radiated emissions Class B (*) in accordance with EN 55022, EN 55011 (CISPR22, CISPR11) group 1 (*) Except configuration (88 970 1.1 or 88 970 1.2) + (88 970 250 or 88 970 270) + 88 970 241 class A (class B in a metal enclosure) Operating Temperature -20 →+70 °C except CB and XB versions in VDC : -30 →+70 °C (+40 °C in a non-ventilated enclosure) in accordance with IEC/EN 60068-2-1 and IEC/EN 60068-22 Datasheet Product Datasheet
-
88974031, Millenium 3 Essential CB20-12I/8O R, 12 x On/Off inputs, Incl 6 analogue inputs, 8 x Static relay outputs incl 4 x PWM output, 24 VDC Supply, Green Display
Free Aus Post Shipping for $300 SpendCrouzet 88974031, Millenium 3 Essential CB20-12I/8O R, 12 x On/Off inputs, Incl 6 analogue inputs, 8 x Static relay outputs incl 4 x PWM output, 24 VDC Supply, Green Display Highly visible blue LCD with 4 lines of 18 characters and configurable backlighting More cost effective solution Allow the use of the entire library of specific functions blocs of the software workshop Extended temperature range (-20 °C →+70 °C) Analogue inputs 0-10 VDC, Potentiometer, NTC, LDR (0-20 mA/Pt100 with converters) Open to XN network communication extensions, digital I/O, analogue, Pt100 extensions HMI Screens Available Specification Crouzet Part Number 88974031 (CB20-12I/8O R) Analogue Inputs 0-10VDC (x6) Digital Inputs 12/24VDC (4.4mA @ 12VDC) (x16) Digital Outputs Relay, 5-30VDC,24-250VAC @ 10mA minimum (x10) PWM SSR Output 12-24VDC @ 500mA (x4) Expandable Yes LCD Display None Mounting Style DIN Rail Mount (124.6mm) Supply Voltage Range 24VDC (21.6 - 28.8VDC) Termination Style Screw Weight 350g Certification CE, UL, CSA, GL Factory Pack Qty 1 Over Voltage Category 3 in accordance with IEC/EN 60664-1 Pollution Degree 2 in accordance with IEC/EN 61131-2 Protection rating IP40 (Front), IP20 (Rear) Mechanical Resistance Immunity to vibrations IEC/EN 60068-2-6, test Fc Immunity to shock IEC/EN 60068-2-27, test Ea Resistance to HF Interference Immunity to radiated electrostatic fields IEC/EN 61000-4-3 Immunity to fast transients (burst immunity) IEC/EN 61000-4-4, level 3 Immunity to shock waves IEC/EN 61000-4-5 Radio frequency in common mode IEC/EN 61000-4-6, level 3 Voltage dips and breaks (AC) IEC/EN 61000-4-11 Immunity to damped oscillatory waves IEC/EN 61000-4-12 Conducted and radiated emissions Class B (*) in accordance with EN 55022, EN 55011 (CISPR22, CISPR11) group 1 (*) Except configuration (88 970 1.1 or 88 970 1.2) + (88 970 250 or 88 970 270) + 88 970 241 class A (class B in a metal enclosure) Operating Temperature -20 →+70 °C except CB and XB versions in VDC : -30 →+70 °C (+40 °C in a non-ventilated enclosure) in accordance with IEC/EN 60068-2-1 and IEC/EN 60068-22 Datasheet Product Datasheet Selection Chart Software Crouzet Touch Soft V6.00.02.173 Software M3-soft-AC9-V3.1.2.0_ML Remote Control Software CVD_PC_V2_3_01_02 Crouzet Soft EVO EM4 1.12.01.14
-
11.216.506 AMK4656 MAHLE - Letrika Unidirectional 24VDC Motor, 3kW, 2600rpm
Heavy Item - No Free ShippingISKRA LETRIKA (MAHLE) 11.216.486 AMK5531 MAHLE - Letrika Unidirectional 24VDC Motor, 3kW, 2600rpm MAHLE Part # MM212 IM0229, 11216506, AMK4656, MM212, 11216425, AMK4653 Specification ISKRA (MAHLE) Part Number 11.216.506 AMK4656 MAHLE ISKRA/LETRIKA/MAHLE IM0229, 11216506, AMK4656, MM212, 11216425, AMK4653 Voltage 24VDC Power 2kW Rotation Biidirectional Clockwise Rotation Speed 2000 rpm Unit Weight 12kg Factory Pack Qty 1 Cross Reference LEWMAR MARINE 66200207 MAHLE LETRIKA (ISKRA) IM0229, 11216506, AMK4656, MM212, 11216425, AMK4653 Application MAKE MODEL TYPE ENGINE POWER YEARS BROC (OIL SISTEM) Spare Parts Spares Page
-
FBS RK SD 24, 24VDC 2 Pole Surge Protection Device for Balanced IT Systems, 5kA, LPZ 0 -2 or higher
FBS RK SD 24, 24VDC 2 Pole Surge Protection Device for Balanced IT Systems, 5kA, LPZ 0 -2 or higher Application Balanced IT Systems Coarse and FIne Protection Industrial Control System Measurement System Device Control Specifications Trent part number FBS RK SD 24 Nominal Voltage 24VDC No of Poles 2 Category IEC / EN / VDE LPZ 0 -2 or higher Location of use Balanced IT Communications Line/signals Protection modes L1+/L2+/GND Additional Remote Contacts N/A Protective element MOV No Fault/Fault Indication N/A Surge discharge rating Per pole 5kA (8/20uS)9KA) Max, 10kA (8/20uS)9KA) Nominal Internal protection and safety Thermal disconnector in each MOV Weight 50g Standards IEC61643-21; GB 18802.21 ; YD/T 1542 Datasheet Product Datasheet GDT/MOV/TVS Tester SPD Tester
$29.00
$34.22 inclGST -
SQ0214 L 110V RC S6SS, Synchroscope (Synchronoscope)
Free Aus Post Shipping for $300 SpendIskra Doo SQ0214 L 110V RC S6SS, Synchroscope (Synchronoscope) Measurement of phase difference between bus bar and generator Five instruments in one (SQ 0x14) Circular display of ∆ phase difference Magnifield display of phase difference ∆ = ±20 Microprocessor processing Simple synchronization conditions setting Output relay for synchronisation (pulse or continuous) ''Dead busbar or generator'' functionality Power supply from bus bar or generator Standard 96x96 mm or 144x144 mm din housing LCD with backlight for voltage, frequency and/or ∆ monitoring (SQ 0x14 only) High immunity to EMC disturbances Special functions set with three jumpers inside the instruments Status output Green led for indication of both voltages Ship version (Bureau veritas certificate - SQ 02x4) Specification Iskra Doo Part Number SQ0214 L 110V RC S6SS Function Phase Difference (∆ϕ) Measurement Nominal Voltage (Un) 110VAC ± 20 % Line to Line (UL-N = 400 VMAX) @ 40-70Hz Digital Output Relay 250 V, 1 A, 50 Hz, 250 VA Status Output Open-Collector 24 Vdc + 20% @30mA Switch On Delay Time Range 0,1 ... 1 s +/-10% Phase Difference Setting Range 2 ... 20 °el ± 3 °el Voltage Difference Setting Range 1 ... 10 % +/-2.5% Dead Busbar Noise Rejection Range 10%, 20%, 30% or 40% Power Consumption < 4VA Short Term Overload 2 x Un for 3 seconds LCD Display Accuracy Voltage 1.5%, Frequency 0.5%, Phase Difference +/-3 °el Synchronisation Accuracy +/- 10% Termination Style Screw Weight 530g Certification CE Factory Pack Qty 1 Enclosure Version Ship Version Material of housing PC/ABS Unflammable, according to UL 94 V-0 Enclosure protection IP52 for case, IP20 for terminals with protective cover Safety According to EN 61 010-1 400 V, installation category III Pollution degree 2 Operating Temperature -20...55 °C Datasheet Product Datasheet User Manual Application Notes & Software Downloads The following parameters can be set via internal jumper see User Manual for more details. Dead Busbar Generator Function Over and Under Frequency Synchronising Adjustable Length of a Sync Pulse The following parameters Can be set via MIPack Comms Module & SQset Setting Software Relay - 300mS/Continuous/Programmable Dead Busbar - Active DB/Active DB + DG & % Threshold MIPack User Manual Download SQSet Settign Software
-
DRD24D06, Dual Solid State Relay, 4-32VDC control, 2 x 6 Amp 24-280VAC Output, Slimline, Din Rail Mount, LED status Indicator
Crydom DRD24D06, Dual Solid State Relay, 4-32VDC control, 2 x 6 Amp 24-280VAC Output, Slimline, Din Rail Mount, LED status Indicator Features Ratings from 3 Amp, 6 Amp, 12 Amp 1-100VDC, 1-60VDC, 24-280VAC, 48-600VAC DIN Rail Mount SCR output for reliable AC switching, or Mosfet for DC Switching Ultra slim package UL/CSA/VDE Approved, CE Compliant to EN60950-1 EMC compliant to Level 3 Epoxy free design Spec Crydom Part Number DRD24D06 Switching Type DC ROHS Yes (Details) Control Voltage 4-32VDC Load Current 2 x 6 Amp (rms) Surge Capability (10ms) 285 Amp (rms) Special Feature LED Status Indicator Mounting Style DIN Rail Mount Load Voltage Range 24-280VAC EMC Compliant Level 3 Termination Style Screw Unit Weight 50g Factory Pack Qty 20 Datasheet Product Datasheet Equivalent Similar part ks32-60-24z2-f41f-1z-c2-4 App Notes Why Use SSR's? The inside story Selecting a SSR DC Output SSR's Selecting a Suitable Heatsink Use of Thermal Interface Material How to Verify the Proper Heatsink Effect of Forced Air Cooling Fuse Protection of SSR's Overvoltage Protection "P" Option MOV SSR Reliability Whitepaper 3 Phase Motors and Heating Applications 3 Phase Motor Reversing How to test a SSR SSR Precautions SSR Life Expectancy MTBF ROHS & Reach Statement Heatsink SSR and Heatsink Assemblies
$184.00
$217.12 inclGST -
FGS1-C/4-275-20, 275VAC 4 Pole Surge Protection Device for Sub Distribution Boards, Class II, Type 2, 40kA (max)
FGS1-C/4-275-20, 275VAC 4 Pole Surge Protection Device for Sub Distribution Boards, Class II, Type 2, 40kA Specifications Trent part number FGS1-C/4-275-20 Nominal Voltage 275VAC No of Poles 4 Category IEC / EN / VDE Class II, Type 2 Location of use Sub Distribution Board Protection modes L-N,L-L Additional Remote Contacts NO Protective element MOV No Fault/Fault Indication Green Flag / Not Green Flag Surge discharge rating Per pole 40kA (8/20uS)9KA) Max, 20kA (8/20uS)9KA) Nominal Internal protection and safety Thermal disconnector in each MOV Standards IEC50539-11 Datasheet Product Datasheet GDT/MOV/TVS Tester SPD Tester
$120.00
$141.60 inclGST -
DRH3P60A20, 20 Amp AC Semiconductor Motor Controller & Contactor, 90-280VAC Control, 48-600VAC Load, Configuration_Auxiliary 2 x SPST (2 x NO)
Free Aus Post Shipping for $300 SpendCrydom DRH3P60A20, 20 Amp AC Semiconductor Motor Controller & Contactor, 90-280VAC Control, 48-600VAC Load, Configuration_Auxiliary 2 x SPST (2 x NO) Features 20 Amp AC Semiconductor Motor Controller Load voltage range up to 600VAC Fits standard 35mm DIN Rail LED input status indicator AC or DC control Zero Voltage (resistive loads) or instantaneous (inductive loads) turn-on output C-UL-US Listed, CCC Certified, IEC Rated, CE & RoHS Compliant, Horsepower Rated Built-in Overvoltage Protection Ultra-efficient thermal management design (Patented) Spec Crydom Part Number DRH3P60A20 Switching Type Zero Crossing Approvals ROHS,CE,ULIEC Control Voltage 90-280VAC Transient Voltage 1200V Load Current (per phase) 20 Amp (rms) Surge Capability (10ms) 716 Amp (peak) Special Feature LED Status Indicator Mounting Style DIN Rail Mount Load Voltage Range 48-600VAC EMC Compliant Level 3 Termination Style Screw Unit Weight 197g Factory Pack Qty 20 Datasheet Product Datasheet App Notes Why Use SSR's? The inside story Selecting a SSR DC Output SSR's Selecting a Suitable Heatsink Use of Thermal Interface Material How to Verify the Proper Heatsink Effect of Forced Air Cooling Fuse Protection of SSR's Overvoltage Protection "P" Option MOV SSR Reliability Whitepaper 3 Phase Motors and Heating Applications 3 Phase Motor Reversing How to test a SSR SSR Precautions SSR Life Expectancy MTBF ROHS & Reach Statement Heatsink SSR and Heatsink Assemblies
-
AKR 5 B420L, Split Core AC Current Sensor, selectable 2, 5 Amp, True RMS 4-20mA output, 21.7mm sqr aperture
Free Aus Post Shipping for $300 SpendLEM AKR 5 B420L Series True RMS Solid Core AC Current Sensor with Process Outputs Compact and versatile Split Core AC current sensor, selectable 2 or 5 Amp True RMS. Choice of output types: 4-20 mA, 0-5 V or 0-10 V Features Split Core True RMS output 4-20mA current output Busbar, or panel mounting Isolated plastic case recognised according to UL94-V0 Advantages Large aperture for busbar/cable up to 21.7mm sqr High isolation between primary and secondary circuits Easy installation DIN Rail Kit available Applications -Automation Systems Analogue current reading for remote monitoring (e.g. Motor) -Data Loggers Self Powered. Will not drain data logger batteries -Panel Meters Simple connection displays power consumption Specification LEM Part Number AK 50 B420L, Technology AC Current Transformer with Process Output ROHS Yes Supply Voltage 24VDC Loop Powered Nominal Current (RMS + DC) 2, 5 Amp Selectable Maximum Measurement Current (Peak) 3.4, 10.1 Amp Output 4-20mA True RMS Aperture 21.7mm sqr Isolation 3kV (AC, 50Hz, 1 min) Bandwidth 50-60Hz Mounting Style Panel Mount Operating Temperature Range -40°C / 85°C Accuracy 1% Termination Style 2 x UNC8 Cylindric Head Unit Weight 120g Factory Pack Qty 6 Datasheet Product Datasheet Application Notes LEM Applications Manual 3rd Edition
-
DPM96W360-2, 96mm x 96mm LCD Active Power Meter, 3 Phase 100-500VAC, 0-6 Amp Inputs, 0.5% Accuracy, 40 to 300VAC/DC Supply, IP54 (Optional IP65)
Free Aus Post Shipping for $300 SpendSecure Meters DPM96W360-2, 96mm x 96mm LCD Active Power Meter, 3 Phase 100-500VAC, 0-6 Amp Inputs, 0.5% Accuracy, 40 to 300VAC/DC Supply, IP54 (Optional IP65) Features LCD Dual Display 250mS Response Time PC 94 UL V0 Each unit needs just 96 x 96mm Panel Space 52mm Depth CE Approved ROHS and REACH Specification Secure Part Number DPM96W360-2 Frequency Range 45-65 Hz Accuracy 0.5% Input 5/6 Amp 3 Phase CT inputs, 100-500VAC Over Range x 1.5 Operating Temperature 0 - 60°C Supply Voltage 40-300VAC/DC Termination Style Screw Mounting Style 96 x 96mm Panel Mount Case Material PC - UL 94 V0 Protection Degree IP54 (IP65 Optional) Standards IEC / EN 61010-1; IEC / EN 61010-2-030, IEC / EN 62053-21 Weight 450g Factory Pack Qty 1 Datasheet Product Datasheet Manual DPM Series User Manual Application Notes Panel Meters Blog Articles
-
DT9-216/D12001, Dual Digital Time Switch with 2 independant Daily Weekly, Monthly, Yearly, Astro, Random program, Universal 12VDC Power Supply/Control, 2 x 16 Amp SPST CO Relay
DT9-216/D12001, Dual Digital Time Switch with 2 independant Daily Weekly, Monthly, Yearly, Astro, Random program, Universal 12VDC Power Supply/Control, 2 x 16 Amp SPST CO Relay DT9-216/AD240001 UNI 12VDC - 2 Relay 16A : Dual Timer Multi-range (1 min - yearly) Astro Timer Function Random Timer Function Multi-voltage 24 →240 V AC/DC LED status indicator Possibility of external load connection in parallel to the control input Specification Assudum Part Number DT9-216/AD240001 Function Daily, Monthly, Yearly, Astronomical, Random Time Switch Nominal Voltage 24VDC Digital Output 2 x C/O (SPST) (Changeover -Single Pole), 250VAC/DC @ 16 Amp Min Breaking Current 10mA/12VDC Timing Ranges Minutes, Hours, Days, Weeks, Months, Years, Astronomical, Sunset, Random Minimum Pulse Duration 30ms/100ms with load Repeatability 0.5% Reset Time 120ms Isolation 4kV Repetition Accuracy 0.5% Threshold Adjustment Range 10 → 100 % of the range Termination Style Screw Weight 80g Factory Pack Qty 1 Over Voltage Category 3 in accordance with IEC/EN 60664-1 Pollution Degree 2 in accordance with IEC/EN 61131-2 Protection rating IP40 (Front), IP20 (Rear) Mechanical Resistance Immunity to vibrations IEC/EN 60068-2-6, test Fc Immunity to shock IEC/EN 60068-2-27, test Ea Resistance to HF Interference Immunity to radiated electrostatic fields IEC/EN 61000-4-3 Immunity to fast transients (burst immunity) IEC/EN 61000-4-4, level 3 Immunity to shock waves IEC/EN 61000-4-5 Radio frequency in common mode IEC/EN 61000-4-6, level 3 Voltage dips and breaks (AC) IEC/EN 61000-4-11 Immunity to damped oscillatory waves IEC/EN 61000-4-12 Conducted and radiated emissions Class B (*) in accordance with EN 55022, EN 55011 (CISPR22, CISPR11) group 1 (*) Except configuration (88 970 1.1 or 88 970 1.2) + (88 970 250 or 88 970 270) + 88 970 241 class A (class B in a metal enclosure) Operating Temperature -20 →+70 °C except CB and XB versions in VDC : -30 →+70 °C (+40 °C in a non-ventilated enclosure) in accordance with IEC/EN 60068-2-1 and IEC/EN 60068-22 Datasheet Product Datasheet
$79.00
$93.22 inclGST