Search results for "tg탤 banonpi 신용불량자소액작업대출 바넌피유심내구제 군산시기초수급자비대면소액대출 kt소액급전내구제대출 휴대폰내구제비대면"
-
ACSP-400-010, Self Powered Split Core AC Current Transducer, 400 Amp AC, 0-10V Average RMS Output, 31mm aperture
ACSP-400-010, Self Powered Split Core AC Current Transducer, 400 Amp AC, 0-10V Average RMS Output, 31mm aperture Compact and versatile Self Powered Split Core AC Current Transducer, Comes with 0-10V/0-5V, or 4-20mA Average RMS Analogue Output Features ⌀31mm Aperture Split Core AC Average RMS Measurement +/-10V analogue output Busbar, or panel mounting Isolated plastic case recognised according to UL94-V0 Advantages High isolation between primary and secondary circuits Easy installation DIN Rail Mount Applications -Automation Systems Analogue current reading for remote monitoring (e.g. Motor) -Data Loggers Self Powered. Will not drain data logger batteries -Panel Meters Simple connection displays power consumption Specification Fastron Part Number ACSP-400-010 Technology AC Hall Effect Current Transducer with Process Output ROHS Yes Supply Voltage Self Powered Nominal Current (DC) 400 Amp RMS Response Time < 200mS Output 0-10VDC Analogue Isolation 2.5kV (AC, 50Hz, 1 min) Bandwidth 50/60Hz Mounting Style DIN Rail Mount Operating Temperature Range -40°C / 85°C Accuracy 1% Termination Style Elevator Screw Unit Weight 120g Factory Pack Qty 6 Datasheet Product Datasheet
$249.00
$293.82 inclGST -
ACSP-50-050, Self Powered Split Core AC Current Transducer, 50 Amp AC, 0-5V Average RMS Output, 31mm aperture
ACSP-50-050, Self Powered Split Core AC Current Transducer, 50 Amp AC, 0-5V Average RMS Output, 31mm aperture Compact and versatile Self Powered Split Core AC Current Transducer, Comes with 0-5V/0-5V, or 4-20mA Average RMS Analogue Output Features ⌀31mm Aperture Split Core AC Average RMS Measurement +/-10V analogue output Busbar, or panel mounting Isolated plastic case recognised according to UL94-V0 Advantages High isolation between primary and secondary circuits Easy installation DIN Rail Mount Applications -Automation Systems Analogue current reading for remote monitoring (e.g. Motor) -Data Loggers Self Powered. Will not drain data logger batteries -Panel Meters Simple connection displays power consumption Specification Fastron Part Number ACSP-50-050 Technology AC Hall Effect Current Transducer with Process Output ROHS Yes Supply Voltage Self Powered Nominal Current (DC) 50 Amp RMS Response Time < 200mS Output 0-5VDC Analogue Isolation 2.5kV (AC, 50Hz, 1 min) Bandwidth 50/60Hz Mounting Style DIN Rail Mount Operating Temperature Range -40°C / 85°C Accuracy 1% Termination Style Elevator Screw Unit Weight 120g Factory Pack Qty 6 Datasheet Product Datasheet
$249.00
$293.82 inclGST -
DCM230 1-4-1-1 V1, DIN Rail Mount DC kWh Meter, 85-265VAC, 85-265VAC aux, Class 1, 45/60/75mV Shunt Connect, w/ 1 x pulse outputs and RS485 Modbus RTU Comms, Single Tariff, MID Approved
DCM230 1-4-1-1 V1, DIN Rail Mount DC kWh Meter, 85-265VAC, 85-265VAC aux, Class 1, 45/60/75mV Shunt Connect, w/ 1 x pulse outputs and RS485 Modbus RTU Comms, Single Tariff, MID Approved 45/60/75mV Shunt Connect RS 485 communication up to 38,400 bit/s as standard 1 x Pulse Outputs (1 Configurable) Bidirectional Measurement The meter is intended for measuring, and monitoring single-phase or electrical power network. The meter records DC Current and Voltage (DC Power) value according to the principle of fast sampling of voltage and current signals. A built-in microprocessor calculates measurands (voltage, current, energy, power) from the measured signals. Features : Accuracy class 1 Measurement of Active and Reactive Power Modbus RTU communication up to 38,400 bit/s communication Pulse output as standard Graphic LCD with illumination Specification Eastron Europe Part Number DCM230 1-4-1-1 V1 Functions DC Energy Meter Supply Voltage 85-265VAC Nominal Measurement Range 5-60VDC Maximum Measurement Range 5-60VDC Nominal Current Input Shunt up to 2000Amp See our DC Current Shunt Section for Suitable Shunt Pulse Output 1 x Configurable 60/100/200ms Tariff Input N/A Accuracy Class 1 (I,U,kW,kWh) Mounting Din Rail Real Time Clock 1min/month (30ppm) Internal Memory N/A Dimensions 36mm x 100mm x 66mm (2 modules wide) Isolation 4kV RS485 2400-38400 b/s Weight 250g Certification EN 61010-1 Installation Category III Factory Pack Qty 1 Safety IP51(Indoor) Enclosure Material Noryl with fire protection to UL94-V-O. Self extinguishing Enclosure Size DIN 42880 4 Modules Operating Temperature -20 →+70 °C Documents Product Datasheet User Manual Modbus Utility EEM Meter Setting Software Utility
$249.00
$293.82 inclGST -
FP030080P/1A, 300/1 Amp Split Core CT, Class 1, 1.5VA Clip On AC Current Transformer, 50 x 80mm Aperture, Dimension 145 x 159 x 37mm
FP030080P/1A, 300/1 Amp Split Core CT, Class 1, 1.5VA Clip On AC Current Transformer, 50 x 80mm Aperture, Dimension 145 x 159 x 37mm Features Quick Release Split Core System Built In Sealable Terminal Covers Mounting Feet Supplied Self Powered Rated System Voltage 0.72/3kV IEC185, BS 7626, BSEN 60044-1 and IEC 60044-1 Applications Metering Equipment Energy Monitoring AC Power Control Systems Power Factor Correction Power Quality Measurements Specification Fastron Part Number FP030080P/1A Technology Split Core AC Clip On Current Transformer Ratio 300/1 Aperture Size 50 x 80mm VA Rating 1.5VA Accuracy Class Class 1 Output 1 Amp AC (+20%) Isolation 3kV (AC, 50Hz, 1 min) Bandwidth 50-60Hz Mounting Style Panel Mount/Busbar Mount Operating Temperature Range -10°C / 50°C Continuous Current (max) 300Amp x 1.2 Termination Style Screw Approvals CE Unit Weight 1150g Factory Pack Qty 1 Datasheet Product Datasheet Installation Guide
$112.00
$132.16 inclGST -
VA720, Portable RTD Calibrator For PT10,PT50,PT100,PT200,PT500,PT1000(385),PT100(JIS) or Ohms, To Measure and Simulate RTD
Free Aus Post Shipping for $300 SpendVA Instruments VA720, Portable RTD Calibrator For PT10,PT50,PT100,PT200,PT500,PT1000(385),PT100(JIS) or Ohms, To Measure and Simulate RTD For Testing of: Volt and mA Calibrator For; Type K, J, E, T, N, S, R, B Thermocouples (see table) Input/Output Voltage Range -10mV to 100mV Voltage Resolution 0.01mV Voltage Accuracy +/-(0.025%+2) 6 x AAA Batteries 205 x 97 x 45mm Optional External AC Adaptor Specification Datasheet Datasheet
-
LTC 350-SF C/L Hall Effect Current Sensor, 350 Amp, 175mA Output, +/-15..24V, ø27.5mm, Panel Mount, w/ feet X = 0.3%
Free Aus Post Shipping for $300 SpendLEM LTC 350-SF Open Loop AC/DC Hall Effect Sensor Features Bipolar and insulated current measurement up tp 1200 Amp Current output Bandwidth DC to 100kHz Closed loop (compensated) current transducer Panel mounting Insulated plastic case recognized according to UL 94-V0 With Busbar and Feet Kit Advantages Very good linearity High accuracy Low offset drift over temperature Wide frequency bandwidth Very low insertion losses High immunity to external interference Current overload capability Low power consumption Applications Railway Equipment Windmill Inverters Test and Measurement Substations AC variable speed drives and servo motor drives Static converters for DC motor drives Battery supplied applications Uninterruptible Power Supplies (UPS) Switched Mode Power Supplies (SMPS) Power supplies for welding applications Application Domain Industrial Standards EN 50178:1997 IEC61010-1:2010 UL 508:2010 Specification LEM Part Number LTC 350-TF Technology Closed Loop Hall Effect Aperture ø27.5mm ROHS Yes Supply Voltage +/- 15 VDC to +/- 24 VDC Bipolar, Isolated Load Current (RMS + DC) 350 Amp Measurement Range +/- 1200 Amp Output 175 mA Isolation 12 kV Bandwidth DC-100 kHz Mounting Style Panel Mount (with feet) Operating Temperature Range -10°C / 85°C Accuracy 0.5% Termination Style Faston 45° 6.3 x 0.8mm and M5 threaded studs Unit Weight 650g Factory Pack Quantity 6 Datasheet Product Datasheet Application Notes LEM Applications Manual 3rd Edition Accessories For Feet Kit or Busbar Kit see datasheet or LEM accessories for more details
-
DPM48F150-2, 48mm x 96mm LCD Digital Frequency Meter, 57.5-250VAC Input, 0.5% Accuracy, 40 to 300VAC/DC Supply, IP54 (IP65 Optional)
Free Aus Post Shipping for $300 SpendSecure Meters DPM48F150-2, 48mm x 96mm LCD Digital Frequency Meter, 57.5-250VAC Input 45-65 Hz, 0.5% Accuracy, 40 to 300VAC/DC Supply, IP54 (IP65 Optional) Features LCD Dual Display 250mS Response Time PC 94 UL V0 Each unit needs just 96 x 48mm Panel Space 52mm Depth CE Approved ROHS and REACH Specification Cewe Part Number DPM48F150-2 Frequency Range 45-65 Hz Accuracy 0.1Hz Input 57.5-250VAC Over Range x 1.5 Operating Temperature 0 - 60°C Supply Voltage 40 to 300VAC/DC Termination Style Screw Mounting Style 96 x 48mm Panel Mount Case Material PC - UL 94 V0 Standards IEC / EN 61010-1; IEC / EN 61010-2-030 Protection Degree IP54 (IP65 Optional) Weight 280g Factory Pack Qty 1 Datasheet Product Datasheet Manual DPM Series User Manual Application Notes Panel Meters Blog Articles
-
FTCK-3-6000INC-100-M8x1x35, Type K Thermocouple, Class A Inconel 600, 6000 x 3mm Probe, M8x1mm Threaded 35mm SS304 Potted Junction, w/ 100mm PFA Twisted Wire, ANSI
Free Aus Post Shipping for $300 SpendFastron FTCK-3-6000INC-100-M8x1x35Type K Thermocouple, Class A Inconel 600, 6000 x 3mm Probe, M8x1mm Threaded 35mm SS304 Potted Junction, w/ 100mm PFA Twisted Wire, ANSI Type K Class A Accuracy PFA Screened Cable Low Long Term Drift Rated for 0 to 1100 Deg C Max Spring Cable Connection 6000 x 3mm (M8x1Pitch x 35mm Threaded Joint for direct mounting) MIMS Specification Fastron Part Number FTCK-3-6000INC-100-M8x1x35 Sensor Type Type K - Thermocouple Class A No of Wires 2 Shaft Length 6000mm Shaft Thickness 3mm (M8x1 Pitchx35mm Potted Joint) Accuracy Class A Cable length 750mm Cable Type Teflon/Screened/Teflon Temperature Range 0 to 1100 Deg C Special Feature Spring Cable Strain Relief Mounting Style M8 x 1Pitch 30mm Thread Weight 2000g Factory Pack Qty 1 Datasheet FTCK-3-6000INC-100-M8x1x35
-
ACSP-100-010, Self Powered Split Core AC Current Transducer, 100 Amp AC, 0-10V Average RMS Output, 31mm aperture
ACSP-100-010, Self Powered Split Core AC Current Transducer, 100 Amp AC, 0-10V Average RMS Output, 31mm aperture Compact and versatile Self Powered Split Core AC Current Transducer, Comes with 0-10V/0-5V, or 4-20mA Average RMS Analogue Output Features ⌀31mm Aperture Split Core AC Average RMS Measurement +/-10V analogue output Busbar, or panel mounting Isolated plastic case recognised according to UL94-V0 Advantages High isolation between primary and secondary circuits Easy installation DIN Rail Mount Applications -Automation Systems Analogue current reading for remote monitoring (e.g. Motor) -Data Loggers Self Powered. Will not drain data logger batteries -Panel Meters Simple connection displays power consumption Specification Fastron Part Number ACSP-100-010 Technology AC Hall Effect Current Transducer with Process Output ROHS Yes Supply Voltage Self Powered Nominal Current (DC) 100 Amp RMS Response Time < 200mS Output 0-10VDC Analogue Isolation 2.5kV (AC, 50Hz, 1 min) Bandwidth 50/60Hz Mounting Style DIN Rail Mount Operating Temperature Range -40°C / 85°C Accuracy 1% Termination Style Elevator Screw Unit Weight 120g Factory Pack Qty 6 Datasheet Product Datasheet
$249.00
$293.82 inclGST -
H-15-2-24, Split Core Hall Effect DC Current Transducer, 0-15 Amp DC, 4-20mA unipolar output, 31mm aperture, 24VDC supply
Free Aus Post Shipping for $300 SpendH-15-2-24, Split Core Hall Effect DC Current Transducer, 0-15 Amp DC, 4-20mA unipolar output, 31mm aperture, 24VDC supply Compact and versatile Split Core DC current sensor, 0-100 Amp DC, 4-20mA Unipolar Output Features ⌀31mm Aperture Split Core DC Unipolar Measurement 4-20mA analogue output Busbar, or DIN Rail Mounting Isolated plastic case recognised according to UL94-V0 Advantages High isolation between primary and secondary circuits Easy installation DIN Rail Mount Applications -Automation Systems Analogue current reading for remote monitoring (e.g. Motor) -Data Loggers Self Powered. Will not drain data logger batteries -Panel Meters Simple connection displays power consumption Specification Fastron Part Number H-15-2-24 Technology DC Hall Effect Current Transducer with Process Output ROHS Yes Supply Voltage 24VDC Nominal Current (DC) 0-15 Amp Response Time < 200mS Output Unipolar 4-20mA Analogue Isolation 2.5kV (AC, 50Hz, 1 min) Bandwidth DC Mounting Style DIN Rail Mount Operating Temperature Range -40°C / 85°C Accuracy 1% Termination Style Elevator Screw Unit Weight 120g Factory Pack Qty 6 Datasheet Product Datasheet
-
FTCK-CLIP-2000-PLUG-C, Type K, Clamp Probe for 60mm Product inside oven w/ 2000mm Steel Insulated Cable, 0 to 650 Deg C
Free Aus Post Shipping for $300 SpendFastron FTCK-CLIP-2000-PLUG-C, Type K, Clamp Probe for 60mm Product inside oven w/ 2000mm Steel Insulated Cable, 0 to 650 Deg C Class A Accuracy Steel Insulated Cable Low Long Term Drift Rated for 0 to 650 Deg C Max Ceramic K Plug 60mm Jaw Clip Specification Fastron Part Number FTCK-CLIP-2000-PLUG-C Sensor Type Type K Thermocouple No of Wires 2 Shaft Length N/A Shaft Thickness N/A Approvals CE, ANSI, ROHS Accuracy Class A Cable length 2 Meter Cable Type Teflon/Screen/Teflon Temperature Range 0 to 650 Deg C Special Feature Clamp Jaw 60mm with Insulated steeel wire and Ceramic K Plug Mounting Style Clamp Jaw 60mm Weight 900g Factory Pack Qty 1
-
Rish Xmer 86-40 (45) 50/5 Class 1 1.5VA ⌀ 51mm or 61 x 12mm Busbar
Heavy Item - No Free ShippingRishabh Rish Xmer 86-40 (45) 50/5 Class 1 1.5VA ⌀ 51mm or 61 x 12mm Busbar, Currentr Transformer Features Built In Sealable Terminal Covers Mounting Feet Supplied Self Powered Rated System Voltage 0.72/3kV IEC185, BS 7626, BSEN 60044-1 and IEC 60044-1 Applications Metering Equipment Energy Monitoring AC Power Control Systems Power Factor Correction Power Quality Measurements Specification Rishabh Part Number Rish Xmer 86-40 (45) 50/5 Class 1 1.5VA Technology AC Current Transformer Ratio 50/5 Aperture Size ⌀ 51mm or 61 x 12mm Busbar VA Rating 1.5VA Accuracy Class Class 1 Output 5 Amp AC (+20%) Isolation 3kV (AC, 50Hz, 1 min) Bandwidth 50-60Hz Mounting Style Panel Mount/Busbar Mount Operating Temperature Range -30°C / 85°C Continuous Current (max) 50Amp x 1.2 Termination Style Screw Unit Weight 0.9kg Factory Pack Qty 9 Datasheet Product Datasheet