RISHABH DMM 616 Digital Multimeter Basic Accuracy: 0.4%, TRUE RMS, Dual display Measurement
Features
Ultra Safe Design
True RMS Measurement
0.4% Accuracy
0.1% Resolution
0.05% Resolution
Hand Held
UL Listed
Auto Power Off
Measurement Parameters
Voltage : 100uV to 1000V AC/DC
Current : 10uA to 10Amp AC/DC
Higher Currents with various CT's
Capacitance from 1pF to 40mF
Resistance form 100mΩ to 66 MΩ
Diode measurement and continuity testing
Hold Measurement
Relative Measurement
Duty Cycle % Measurement
Temperature Measurement with Type K Thermocouple
Peak Value Measurement
Specification
RISHABH Part Number
RISHABH DMM 616
Voltage Measurement Range
0.0001 - 1000 VAC/DC Average RMS
Impedance Measurement Range
100mΩ - 66MΩ
Current Measurement Range
0.00001 - 10 Amp AC/DC Average RMS
Isolation
4.26kV
Bandwidth
DC & 20Hz to 2kHz
Battery Voltage
3VDC
Temp Measurement Range
1 - 1300 Deg C
Frequency Measurement Range
0.01Hz to 10kHz
Weight
500g
Factory Pack Qty
1
EMC
EN61326: 2002 Class B
Safety Standards
IEC 61010-1-2010 and IEC 61557, 1000V CAT III/600V CAT IV
Datasheet
Datasheet
User Manual
Fastron H31/110M + FTH2553ZD3, 3 Phase Solid State Relay, with Heatsink, IP20 Cover, Panel Mount, 25 Amps Per Phase @ 50 Deg C, 530VAC Load, with IP20 Cover
Ratings from 25 to 120 Amp @ 70-480 VAC
SCR output for heavy industrial loads
Zero voltage or Instantaneous turn-on outputs
IP20 Cover Included
AC & DC control types
Direct bond copper substrate
Direct power lead frame
Includes IP20 Cover
Specification
Fastron Part Number
H31/110M + FTH2553ZD3
Switching Type
Zero Crossing
ROHS/CE/UL
Yes
Control Voltage
3-32VDC
Load Current
3 x 25 Amp (rms) @ 50 Deg C
Surge Capability
350 Amp (peak)
Special Feature
LED Status Indicator, with IP20 Cover
Mounting Style
Panel Mount
Load Voltage Range
70-530VAC
Dimensions
L:110 x W:125 x D:180mm
EMC Compliant
Level 3
Termination Style
Screw
Unit Weight
2kg
Factory Pack Qty
10
Datasheet
Product Datasheet
H31 Datasheet
Equivalent Parts
Contact Us for Possible Replacement
Fastron H31/110M & FCR-400-60R, Three Phase Proportional Phase Control Module with Heatsink, 4-20mA,0-10V,500K POT Input, 400VAC, 25 Amp Per Phase @ 50 Deg C
4-20mA,0-10V, or 500K POT Proportional Phase Control Input
Ratings from 25A to 80 Amp @ 180-280 VAC
SCR output for heavy industrial loads
Instantaneous turn-on output
Direct bond copper substrate
Direct power lead frame
Epoxy free design
Specification
Trent part Number
H31/110M & FCR-400-60R
Switching Type
Phase Angle (Random Crossing)
Control Voltage
4-20mA,0-10V,500K POT Proportional Input
Load Current
25 Amp (rms) @ 50 Deg C, 30 Amp Per phase @ 40 Deg C
Surge Capability
500Amp (peak)
Special Feature
3 Phase Proportional Controller + SSR/3 Phase Voltage Regulator
Mounting Style
Panel Mount
Load Voltage Range
180-400VAC +10%
Max Non Repetitive Peak Voltage
600 Vp
Termination Style
Barrier Strip Screw
Dimensions
L:110 x W:125 x D:180mm
Unit Weight
2kg
Factory Pack Qty
20
Datasheet
FCR-400-60R
Product Notifications
Please note Changes from Gen 3 to Gen 4 (current) package design here
Timer Chronos2 MAR1 Mono Timer 20-30VDC & 20- 264 VAC, Function A and Function At
MAR1 Timers Syrline 17.5 mm - 1 C/O Relay 8A :
Multi-range (0.1s - 100hrs)
Multi-voltage 12 →240 V AC/DC
LED status indicator
Possibility of external load connection in parallel to the control input
3-wire PNP sensor compatible
Multifunction Timers Includes The Following :
Function A Delay on energisation 1 relay
Function At Timing on energisation with memory 1 relay
Specification
Crouzet Part Number
88827135 (Syr-Line Timer Single Pole Double Throw 1 x 8A, 12 - 240VAC/DC, 17.5 mm)
Function
Single Function A or At
Nominal Voltage
12 → 240 V AC/DC
Digital Output
1 x C/O (DPDT) (Changeover -Single Pole Double Throw-), 250VAC/DC @ 8 Amp
Min Breaking Current
10mA/12VDC
Timing Ranges
Selectable 0.1s - 1s - 10s - 1 min - 10min - 1h, 10h, 100h
Minimum Pulse Duration
30ms/100ms with load
Repeatability
0.5%
Reset Time
120ms
Isolation
4kV
Repetition Accuracy
0.5%
Threshold Adjustment Range
10 → 100 % of the range
Termination Style
Screw
Weight
80g
Certification
CE, cULus,CCC, ROHS, Reach, WEEE
Factory Pack Qty
1
Over Voltage Category
3 in accordance with IEC/EN 60664-1
Pollution Degree
2 in accordance with IEC/EN 61131-2
Protection rating
IP40 (Front), IP20 (Rear)
Mechanical Resistance
Immunity to vibrations IEC/EN 60068-2-6, test Fc
Immunity to shock IEC/EN 60068-2-27, test Ea
Resistance to HF Interference
Immunity to radiated electrostatic fields IEC/EN 61000-4-3 Immunity to fast transients (burst immunity) IEC/EN 61000-4-4, level 3 Immunity to shock waves IEC/EN 61000-4-5 Radio frequency in common mode IEC/EN 61000-4-6, level 3 Voltage dips and breaks (AC) IEC/EN 61000-4-11 Immunity to damped oscillatory waves IEC/EN 61000-4-12
Conducted and radiated emissions
Class B (*) in accordance with EN 55022, EN 55011 (CISPR22, CISPR11) group 1 (*) Except configuration (88 970 1.1 or 88 970 1.2) + (88 970 250 or 88 970 270) + 88 970 241 class A (class B in a metal enclosure)
Operating Temperature
-20 →+70 °C except CB and XB versions in VDC : -30 →+70 °C (+40 °C in a non-ventilated enclosure) in accordance with IEC/EN 60068-2-1 and IEC/EN 60068-22
Datasheet
Product Datasheet
Cross Reference
frt8-m2-w240
Electronicon 275.186-709600/221K02 25kvar 525V 50Hz, Power Factor Correction Capacitor, 3 Phase, 116 x 230(+32 +5/-2)mm Gas Filled, 3 x 96.2uF, DOUBLE SIDED TERNINALS Replaces 275.186-809600
Characteristics and utility
25kVar @ 525V @ 50 Hz 10.0kvar 10kvar
Three phase capacitor DUAL WINDING internally delta connected
Discharge resistors Incorporated
Reactive power factor correction
Gas Filled Lightweight Construction
Connector type - single sided terminal
Indoor mounting
Triple safety
Overpressure disconnection system
Protection by internal fuses
Self Healing
Construction and materials
Low losses metallized self-healing polypropylene film, high density, high temperature and greater dielectric resistance Volt/µ
Aluminium case with bottom fixing M12x16
Standards
IEC 60831-1/2
EN 60831-1/2
Specification
Electronicon Part Number
275.186-709600/221K02 25kvar 525V 50Hz
Technology
Gas Filled, Low Loss, Self Healing
Dimensions
116 x 230(+32)mm
Standards
IEC 60831-1/2, EN 60831-1/2
Voltage
525V @ 50Hz
Kvar
25 Kvar
Capacitance
3 x 96.2uF
Discharge Resistors (Not Included)
275.105-10120 & 275-100-10180
Tolerance On Capacitance
-5% + 10% (others on request)
Current (In)
3 x 45 Amp
Overpressure Disconnection System
YES
Self Extinguishing Resin
YES
Internal Fuses
YES
Self Healing
YES
Mounting
M12 x 16mm (Indoor)
Operating Temperature Range
50°C Max, 30°C Mean(1 year), 40°C Mean(24 hrs)
Lifetime
120,000 Hours
Termination Style
Filter Type Terminal
Approvals
UL 810, CSA C22.2 No.90
Unit Weight
2.3kg
Factory Pack Quantity
25
Datasheet
Product Datasheet
Replaces Part# 275.189-714301-221702 which is now obsolete
Application Notes
Discharge Resistor Usage
Power Factor Correction Blog
Iskra ISPRO-K BSR 75/440 (3+0), Class I,II / Type 1,2 / B,C, Surge Protection Device (SPD) with Remote Contact, 3 Pole 75kA,440VAC, DIN Rail Mount
Specifications
Iskra Doo part number
ISPRO-K BSR 75/440 (3+0)
Nominal Voltage
440VAC
No of Poles
3
Category IEC / EN / VDE
Class I,II / Type 1,2 / B,C
Location of use
Main Distribution Boards
Protection modes
L/N-PE, L-PEN, L-N, N-PE High Energy MOV and GDT
Protective element
MOV + GDT
Surge discharge rating
Imax up to 75 kA, or 25kA per pole
Internal protection and safety
Thermal disconnector in each MOV
Standards
IEC/EN 61643-11
Datasheet
Product Datasheet
Iskra ISPRO BSR 25/440, Class I, II / Type 1,2 / B, C, Surge Protection Device (SPD) with Remote Contacts, 3 Pole 37.5kA,440VAC, DIN Rail Mount, L/N-PE, L-PEN, L-N, N-PE High Energy MOV and GDT
Specifications
Iskra Doo part number
ISPRO BSR 25/440
Nominal Voltage
440VAC
No of Poles
3
Category IEC / EN / VDE
Class I,II / Type 1,2 / B,C
Location of use
Main Distribution Boards
Protection modes
L/N-PE, L-PEN, L-N, N-PE High Energy MOV and GDT
Additional Remote Contacts
YES
Protective element
MOV + GDT
Surge discharge rating
Imax up to 25 kA
Internal protection and safety
Thermal disconnector in each MOV
Standards
IEC/EN 61643-11
Datasheet
Product Datasheet
Fastron Electronics SCT-F16-100, 0.333V Output, 100Amp measurement Split Core Current Transformer, 16mm Aperture
Features
Quick Release Split Core System
Cable Mount
0.333V Output
Self Powered
Rated System Voltage 0.60/3kV
0.5M Flying Leads
Applications
US Based Metering Equipment
Energy Monitoring
AC Power Control Systems
Power Factor Correction
Power Quality Measurements
Specification
Fastron Part Number
SCT-F16-100
Technology
Split Core AC Current Transformer
Ratio
100/0.333V
Aperture Size
ø 15 mm
VA Rating
N/A
Accuracy Class
Class 1
Output
0.333V (+20%)
Isolation
3kV (AC, 50Hz, 1 min)
Bandwidth
50-60Hz
Mounting Style
Cable Mount/Busbar Mount
Operating Temperature Range
-15°C / 45°C
Continuous Current (max)
100Amp x 1.2
Termination Style
0.5M Flying leads
Unit Weight
100g
Factory Pack Qty
9
Datasheet
Product Datasheet
Application Notes
Installation Guide
Fastron Electronics SCT-F16-150, 0.333V Output, 150Amp measurement Split Core Current Transformer, 16mm Aperture
Features
Quick Release Split Core System
Cable Mount
0.333V Output
Self Powered
Rated System Voltage 0.60/3kV
0.5M Flying Leads
Applications
US Based Metering Equipment
Energy Monitoring
AC Power Control Systems
Power Factor Correction
Power Quality Measurements
Specification
Fastron Part Number
SCT-F16-150
Technology
Split Core AC Current Transformer
Ratio
150/0.333V
Aperture Size
ø 15 mm
VA Rating
N/A
Accuracy Class
Class 1
Output
0.333V (+20%)
Isolation
3kV (AC, 50Hz, 1 min)
Bandwidth
50-60Hz
Mounting Style
Cable Mount/Busbar Mount
Operating Temperature Range
-15°C / 45°C
Continuous Current (max)
150Amp x 1.2
Termination Style
0.5M Flying leads
Unit Weight
100g
Factory Pack Qty
9
Datasheet
Product Datasheet
Application Notes
Installation Guide
Fastron FCR-400-60R, Three Phase Proportional Phase Control Module, 4-20mA,0-10V,500K POT Input, 400VAC, 60 Amp Per Phase, Also referred to as 3 Phase Voltage Regulator
4-20mA,0-10V, or 500K POT Proportional Phase Control Input
Ratings from 25A to 120 Amp @ 180-280 VAC
SCR output for heavy industrial loads
Instantaneous turn-on output
Direct bond copper substrate
Direct power lead frame
Epoxy free design
Specification
Trent part Number
FCR-400-60R
Switching Type
Phase Angle (Random Crossing)
Control Voltage
4-20mA,0-10V,500K POT Proportional Input
Load Current
60 Amp (rms) @ 40 Deg C
Surge Capability
597Amp (peak)
Special Feature
3 Phase Proportional Controller + SSR/3 Phase Voltage Regulator
Mounting Style
Panel Mount
Load Voltage Range
180-400VAC +10%
Max Non Repetitive Peak Voltage
600 Vp
Termination Style
Barrier Strip Screw
Dimensions
105 x 80 x 55mm
Unit Weight
400g
Factory Pack Qty
20
Datasheet
FCR-400-60R
Fastron FCR-400-120R, Three Phase Proportional Phase Control Module, 4-20mA,0-10V,500K POT Input, 400VAC, 120 Amp Per Phase, Also referred to as 3 Phase Voltage Regulator
4-20mA,0-10V, or 500K POT Proportional Phase Control Input
Ratings from 25A to 120 Amp @ 180-280 VAC
SCR output for heavy industrial loads
Instantaneous turn-on output
Direct bond copper substrate
Direct power lead frame
Epoxy free design
Specification
Trent part Number
FCR-400-120R
Switching Type
Phase Angle (Random Crossing)
Control Voltage
4-20mA,0-10V,500K POT Proportional Input
Load Current
120 Amp (rms) @ 40 Deg C
Surge Capability
1100Amp (peak)
Special Feature
3 Phase Proportional Controller + SSR/3 Phase Voltage Regulator
Mounting Style
Panel Mount
Load Voltage Range
180-400VAC +10%
Max Non Repetitive Peak Voltage
600 Vp
Termination Style
Barrier Strip Screw
Dimensions
105 x 80 x 55mm
Unit Weight
400g
Factory Pack Qty
20
Datasheet
FCR-400-120R