DV 4200/SP3 Digital Voltage Transducer, Vpn = 4200V, +/-15...24VDC, 50mA output, 18.5kV Isolation
LEM DV 4200/SP3 Digital Voltage Transducer, Vpn = 4200V, +/-15...24VDC, 50mA output, 18.5kV Isolation, SP3 has extra long thread terminals Features Bandwidth DC to 12kHz Closed loop transducer using Hall effect Digital Transducer (ASIC based) Compact and versatile Panel Mount Insulated plastic case recognized according to UL 94-V0 Advantages Very good linearity High accuracy Low temperature drift Wide frequency bandwidth Very low insertion losses High immunity to external interference Voltage overload capability Low power consumption Applications Railway substation or locomotive AC variable speed drives and servo motor drives Static converters for DC motor drives Battery supplied applications Uninterruptible Power Supplies (UPS) Switched Mode Power Supplies (SMPS) Power supplies for welding applications Water Treatment Electronics Specification LEM Part Number DV 4200/SP3 Technology Closed Loop Hall Effect Aperture No Aperture ROHS Yes Supply Voltage +/-15..24 VDC Bipolar, Isolated Primary Nominal Voltage (RMS + DC) +/- 4200V Measurement Range +/- 6000V Output 50 mA @Vpn Isolation 18.5 kV Bandwidth DC-13 kHz Mounting Style Panel Mount Operating Temperature Range -40°C / 85°C Accuracy 1% Termination Style M5 Screw Unit Weight 1000g Factory Pack Quantity 4 Datasheet Product Datasheet Application Notes LEM Applications Manual 3rd Edition
$1,642.00
$1,937.56 inclGST -
N1159NC400, Thyristor(SCR) PUK, 1159Amp, 4200V, 74/26
Free Aus Post Shipping for $300 SpendWestcode-IXYS-Littlefuse N1159NC400, Thyristor(SCR) PUK, 1159Amp, 4200V, 74/26 Features Very low forward voltage drop Very low leakage current International standard package 74/26 Package Press Mounted Double or Single Sided Cooling Applications Power Supplies Rectifier for drives applications Uncontrolled Rectifiers Rectifiers for UPS Battery Chargers Field Supply for DC Motors Water Cooled Rectifiers DC Substation Blocking Diode Large Generators Specification Westcode-IXYS-Littlefuse Part Number N1159NC400 Vrrm 4000V Diode Configuration Thyristor Capsule (PUK) IF(av) @ 60 Deg C 1159 Amp Package Size ø74 x 26mm Itsm 14.5 kA VF(to) 1.1V Tj(max) 125°C rF 0.574mΩ Gate Terminals Faston R th(j-c) (double sided cooled 180°sin) 0.022°C/W R th(c-h) (double sided cooled) 0.044°C/W Weight 510g Clamping Force 19 - 26kN Factory Pack Qty 6 Certification ROHS Westcode-IXYS-Littlefuse Headquarters UK Datasheet Product Datasheet Alternatives DCR1260F42 Contact Us for Possible Replacement Heatsink Heatsink Profiles
-
MG73BQ 3 Phase 4 Wire or Single Phase Voltage Monitoring Relay With DPDT Contacts, Undervoltage, Selectable Overvoltage, 3 x 120-240 VAC
Free Aus Post Shipping for $300 SpendGIC Controls MG73BQ 3 Phase 4 Wire or Single Phase Voltage Monitoring Relay With DPDT Contacts, Undervoltage, Selectable Overvoltage, 3 x 120-240 VAC Relay control, on 3-phase networks : Overvoltage between phases, Undervoltage between phases Overvoltage between phases and neutral, Undervoltage between phases and neutral, Loss of neutral Multi-voltage Products Controls its own supply voltage True RMS measurement LED status indication 3-phase voltage controllers which monitor : Undervoltage, adjustable from -20 to -2 % of Un Overvoltage, adjustable from 2 to 20 % of Un Measurements are taken between neautral and Phases for MG73BQ MG73BQ and between Phases and Neutral for the H3USN Faults are signalled via LEDs, distinguishing the origin of the fault (one LED for the upper threshold, one LED for the lower threshold). Set the selector switch to the 3-phase network voltage Un. The position of this selector switch is only taken into account when the unit is powered up. If the switch position changes while the unit is operating, all the LEDs flash but the product continues to work normally with the voltage selected on energisation prior to the change of position. The LEDs return to their normal state if the switch is reset to its initial position defined before the last energisation. Specification GIC Controls Part Number MG73BQ (3 Phase 4 Wire/Single Phase Monitoring Relay With DPDT Contacts) Function Undervoltage/Overvoltage between phases Nominal Voltage 3 x 120 → 3 x 240 V ∿ Digital Outputs 2 x C/O Relays, 250VAC/DC @ 5 Amp Min Breaking Current 10mA/5VDC Timing Range 0.3 → 30s (0, +10%) Delay on Pickup 500ms Alarm Delay on Time (max) 200ms Reset Time 1500ms Fixed Hysteresis 2% of Un Maximum Measurement Cycle Time 150ms/True RMS Measurement Measurement Accuracy 1% Supply Voltage Range Same as Measurement 3 x 220 → 3 x 480 V ∿ Termination Style Screw Weight 170g Certification CE, UL, CSA, GL, ROHS Factory Pack Qty 1 Over Voltage Category 3 in accordance with IEC/EN 60664-1 Pollution Degree 2 in accordance with IEC/EN 61131-2 Protection rating IP40 (Front), IP20 (Rear) Mechanical Resistance Immunity to vibrations IEC/EN 60068-2-6, test Fc Immunity to shock IEC/EN 60068-2-27, test Ea Resistance to HF Interference Immunity to radiated electrostatic fields IEC/EN 61000-4-3 Immunity to fast transients (burst immunity) IEC/EN 61000-4-4, level 3 Immunity to shock waves IEC/EN 61000-4-5 Radio frequency in common mode IEC/EN 61000-4-6, level 3 Voltage dips and breaks (AC) IEC/EN 61000-4-11 Immunity to damped oscillatory waves IEC/EN 61000-4-12 Conducted and radiated emissions Class B (*) in accordance with EN 55022, EN 55011 (CISPR22, CISPR11) group 1 (*) Except configuration (88 970 1.1 or 88 970 1.2) + (88 970 250 or 88 970 270) + 88 970 241 class A (class B in a metal enclosure) Operating Temperature -20 →+70 °C except CB and XB versions in VDC : -30 →+70 °C (+40 °C in a non-ventilated enclosure) in accordance with IEC/EN 60068-2-1 and IEC/EN 60068-22 Datasheet Product Datasheet
-
MSKP964C_A26, Thyristor(SCR) PUK 964 Amp, 2600V, 80/16
Free Aus Post Shipping for $300 SpendMS Power MSKP964C_A26, Thyristor(SCR) PUK 964 Amp, 2600V, 80/16 Features Very low forward voltage drop Very low leakage current International standard package 80/16 unique and hard to find Package Press Mounted Double or Single Sided Cooling Applications Power Supplies Rectifier for drives applications Controlled Rectifiers AC Switch Field Supply for DC Motors Water Cooled Rectifiers Phase Controllers Power Factor Correction Specification MS Power Part Number MSKP964C_A26 Vrrm 2600V Diode Configuration Diode Capsule (PUK) IF(av) @ 68 Deg C 964 Amp Package Size ø80 x 16.5mm Itsm 16.5 kA VF(to) 1.05V Tj(max) 125°C rF 0.5mΩ Gate Terminals Faston 4.8 x 0.8mm & 2.8 x 0.8mm R th(j-c) (double sided cooled 180°sin) 0.027°C/W R th(c-h) (double sided cooled) 0.0031°C/W Weight 520g Clamping Force 22 - 24kN Factory Pack Qty 12 MS Power Headquarters China Datasheet Product Datasheet Heatsink Note this item requires a special clamp. Heatsink Profiles
-
11.212.935 AMJ5265 MAHLE - Letrika Unidirectional CW 12VDC Motor, 1.6kW, 2600rpm
Heavy Item - No free ShippingISKRA LETRIKA (MAHLE) 11.212.935 AMJ5265 MAHLE - Letrika Unidirectional CW 12VDC Motor, 1.6kW, 2600rpm MAHLE Part # MM 191 11212.958 11212958 IM0055 Specification ISKRA (MAHLE) Part Number 11.212.935 AMJ5265 MAHLE ISKRA/LETRIKA/MAHLE IM0050, 11212935, AMJ5265, MM273, 11212112, AMJ5669, 11212082, AMJ5646, 11212075, AMJ5641 Voltage 12VDC Power 1.6kW Rotation Unidirectional Clockwise Rotation Speed 2600 rpm Unit Weight 6.9kg Factory Pack Qty 1 Cross Reference FLUITRONICS (BERENDSEN) 1240247, 9000566912 LUCAS 47044608 MAHLE LETRIKA (ISKRA) IM0050, 11212935, AMJ5265, MM273, 11212112, AMJ5669, 11212082, AMJ5646, 11212075, AMJ5641 SPX FLUID POWER (FENNER) MF4034 MAKE MODEL TYPE ENGINE POWER YEARS BUCHER HYDRAULICS (HIDROIRMA) PEDRO ROQET SPX FLUID POWER (FENNER) WEBER Spare Parts Spare Parts Page
-
84870700, Liquid Level Control Relay, 240VAC or 24VAC/DC Aux Supply, DPDT 5 Amp, 2 Level Control, With time delay adjustments, HNM 24-240V AC/DC
Crouzet 84870700, Liquid Level Control Relay, 240VAC or 24VAC/DC Aux Supply, DPDT 5 Amp, 2 Level Control, With time delay adjustments, HNM 24-240V AC/DC Level Switch, 110/240VAC or 24VAC/DC Aux Supply 2 x 5 Amp changeover/SPDT (AgNi / Silver Alloy) Relay Features : 1. one-level switch of conductive liquids 2. two-level switch of conductive liquids ! One-state device monitors one level, two-state device monitors two levels (switches on one level and switches off on another level) Choice of function PUMP UP, PUMP DOWN Adjustable time delay on the output (0.5 - 10 s) Sensitivity adjustable by a potentiometer (5-100 kÙ) Measuring frequency 10Hz prevents polarization of liquid and raising oxidation of measuring probes Galvanically separated supply voltage UNI 24.. 240 VAC/DC Output contact 1xchangeover/SPDT 8A/250V AC1 1-module type, mounting onto a DIN rail Specification Crouzet Part Number 84870210 Voltage Range 110/240VAC or 24VAC/DC Sensitivity (Input resistance) 50kOhm to 1MOhm Electrode Voltage 3.5 max Trip Adjustment Potentiometer Setting Accuracy 5 % Burden max. 12 VA Repeatability 1 % Temperature Drift 0.1%/°C Peak Overload (10s) 100 Amp Time delay T1 max. 400 ms Time delay T2 adjustable 0.1-10 s Control Type 1 or 2 Level Number of contacts 2 x changeover/ SPDT (AgNi / Silver Alloy) Rating 2 x 5 A / AC1 Breaking capacity 2500 VA / AC1, 250 W / DC Inrush current (3s) 10 A Switching voltage 250 V AC1 / 24 V DC Min. breaking capacity DC 500 mW Indication of state red LED Mechanical life 1 x 107 Electrical life (AC1) 1 x 105 Other information Operating temperature -20 ... +55 °C Storage temperature -30 ... +70 °C Electrical strength 4 kV (supply - output) Operating position any Mounting DIN rail EN 60715 Protection degree IP 40 from front panel / IP 10 terminals Overvoltage cathegory III. Pollution degree 2 Max. cable size (mm )2 solid wire max. 2x2.5 or 1x4 ; with sleeve max. 1x2.5 or 2x1.5 Dimensions 90 x 17,6 x 64 mm Weight 109 g Standards EN 60255-6, EN 61010-1 Datasheet Product Datasheet Sensors for use with PLT Series Tank Level Sensors
$189.00
$223.02 inclGST -
HS211 + MCBC2425CF, Single Phase Proportional Burst Controller with Heatsink, 10 Cycles, 0-10VDC Input, 90-280VAC, 24 Amps
Free Aus Post Shipping for $300 SpendCrydom HS211 + MCBC2425CF, Single Phase Proportional Burst Controller with Heatsink, 10 Cycles, 0-10VDC Input, 90-280VAC, 24 Amps Features Proportional Phase Control Input Ratings from 25A to 90 Amp @ 180-280 VAC SCR output for heavy industrial loads Zero voltage or instantaneous turn-on outputs UL/CE/ROHS Compliant Direct bond copper substrate Direct power lead frame Epoxy free design Panel Mount Din Rail Mount Spec Part Number HS211 + MCBC2425CF Switching Type Burst Fire (Zero Crossing) ROHS/CE/UL Yes Control Voltage 0-10V Proportional Input Load Current 24 Amp (rms) @ 40 Deg C Surge Capability 239 Amp (peak) Special Feature Proportional Controller + SSR Mounting Style Din Rail or Panel Mount Load Voltage Range 180-280VAC Max Non Repetitive Peak Voltage 600 Vp Termination Style Screw Terminals Dimensions L:81mm x W:45mm x D:73.4mm Unit Weight 296g Factory Pack Qty 20 Datasheet HS211 MCBC Series Notifications Please note Changes from Gen 3 to Gen 4 (current) package design here App Notes Why Use SSR's? The inside story Selecting a SSR DC Output SSR's Selecting a Suitable Heatsink Use of Thermal Interface Material How to Verify the Proper Heatsink Effect of Forced Air Cooling Fuse Protection of SSR's Overvoltage Protection "P" Option MOV SSR Reliability Whitepaper 3 Phase Motors and Heating Applications 3 Phase Motor Reversing How to test a SSR SSR Precautions SSR Life Expectancy MTBF ROHS & Reach Statement Heatsink SSR and Heatsink Assemblies
-
SDM630MCT-LORAWAN-MID-AU915, DIN Rail Mount kWh Meter, 3 Phase, 240VAC aux, Class 1, 1/5 Amp CT Connect, w/ 2 x pulse outputs and LoRaWaN AU915 Wireless Comms
SDM630MCT-LORAWAN-MID-AU915, DIN Rail Mount kWh Meter, 3 Phase, 240VAC aux, Class 1, 1/5 Amp CT Connect, w/ 2 x pulse outputs and LoRaWaN AU915 Wireless Comms 1/5 Amp CT Input LoRaWaN AU915 Optional Mbus Model available True RMS values of currents and voltages 1 x Configurable Pule Output (via Display Menu or Modbus) 1 x Fixed Pulse Output (1000imp/kwh) The meter is intended for measuring, and monitoring single-phase or 3 phase electrical power network. The meter records TRMS value according to the principle of fast sampling of voltage and current signals. A built-in microprocessor calculates measurands (voltage, current, frequency, energy, power to the 30th Harmonic) from the measured signals. Features : Accuracy class 1 Measurement of Active and Reactive Power Modbus RTU communication up to 38,400 bit/s communication Pulse output as standard Graphic LCD with illumination Specification Eastron Europe Part Number SDM630MCT-LORAWAN-MID-AU915 Functions Three Phase Energy Meter Supply Voltage 230V L-N +/-15% < 5VA Nominal Measurement Range 415V L-L 230V L-N, 1/5 Amp +/-15% Maximum Measurement Range 480V L-L 230V L-N, 1/5 Amp Nominal CT Current Input 1/5 Amp Pulse Output 2 x Passive, (1 x Configurable 60/100/200ms) Tariff Input N/A Accuracy Class 1 (I,U,F,kW,kWh) Class 2 (Reactive) Mounting Din Rail Real Time Clock 1min/month (30ppm) Internal Memory N/A Dimensions 72mm x 100mm x 66mm (4 modules wide) Isolation 4kV Comms LoRaWaN AS915 Weight 150g Certification EN 61010-1 Installation Category III Factory Pack Qty 1 Safety IP51(Indoor) Enclosure Material Noryl with fire protection to UL94-V-O. Self extinguishing Enclosure Size DIN 42880 4 Modules Operating Temperature -20 →+70 °C Documents Product Datasheet User Manual Modbus Protocol Setup Video - CT Ratio Unlock Modbus Utility EEM Meter Setting Software Utility
$339.00
$400.02 inclGST -
SSC1000-25-12, 8-16VDC Input, 1kV, 25Amp DC Output SSR
Free Aus Post Shipping for $300 SpendCrydom SSC1000-25-12, 8-16VDC Input, 1kV, 25Amp DC Output SSR Features Ratings from 20 Amp @ 1-1000VDC Mosfet output for reliable DC switching Multiple modules can be wired in parallel for higher currents UL/CSA/VDE Approved, CE Compliant to EN60950-1 Improved SEMS screw and washer Redesigned housing with anti-rotation barriers Direct bond copper substrate EMC compliant to Level 3 Direct power lead frame Epoxy free design Spec Crydom Part Number SSC1000-25-12 Switching Type DC Load ROHS Yes (Details) Control Voltage 8-16VDC Load Current 25 Amp DC Surge Capability (10ms) 75 Amp DC Special Feature None Mounting Style Panel Mount Load Voltage Range 0 - 1000VDC EMC Compliant Level 3 Termination Style Screw Unit Weight 82g Factory Pack Qty 20 Datasheet Product Datasheet Notifications Please note Changes from Gen 3 to Gen 4 (current) package design here App Notes Why Use SSR's? The inside story Selecting a SSR DC Output SSR's Selecting a Suitable Heatsink Use of Thermal Interface Material How to Verify the Proper Heatsink Effect of Forced Air Cooling Fuse Protection of SSR's Overvoltage Protection "P" Option MOV SSR Reliability Whitepaper 3 Phase Motors and Heating Applications 3 Phase Motor Reversing How to test a SSR SSR Precautions SSR Life Expectancy MTBF ROHS & Reach Statement Heatsink SSR and Heatsink Assemblies
-
HS211 + MCBC4825DL, Single Phase Proportional Burst Controller with Heatsink, 20 Cycles, 4-20mA Input, 90-530VAC, 24 Amps
Free Aus Post Shipping for $300 SpendCrydom HS211 + MCBC4825DL, Single Phase Proportional Burst Controller with Heatsink, 20 Cycles, 4-20mA Input, 90-530VAC, 24 Amps Features Proportional Phase Control Input Ratings from 25A to 90 Amp @ 380-530 VAC SCR output for heavy industrial loads Zero voltage or instantaneous turn-on outputs UL/CE/ROHS Compliant Direct bond copper substrate Direct power lead frame Epoxy free design Panel Mount Din Rail Mount Spec Part Number HS211 + MCBC4825DL Switching Type Burst Fire (Zero Crossing) ROHS/CE/UL Yes Control Voltage 4-20mA Proportional Input Load Current 24 Amp (rms) @ 40 Deg C Surge Capability 239 Amp (peak) Special Feature Proportional Controller + SSR Mounting Style Din Rail or Panel Mount Load Voltage Range 380-530VAC Max Non Repetitive Peak Voltage 600 Vp Termination Style Screw Terminals Dimensions L:81mm x W:45mm x D:73.4mm Unit Weight 296g Factory Pack Qty 20 Datasheet HS211 MCBC Series Notifications Please note Changes from Gen 3 to Gen 4 (current) package design here App Notes Why Use SSR's? The inside story Selecting a SSR DC Output SSR's Selecting a Suitable Heatsink Use of Thermal Interface Material How to Verify the Proper Heatsink Effect of Forced Air Cooling Fuse Protection of SSR's Overvoltage Protection "P" Option MOV SSR Reliability Whitepaper 3 Phase Motors and Heating Applications 3 Phase Motor Reversing How to test a SSR SSR Precautions SSR Life Expectancy MTBF ROHS & Reach Statement Heatsink SSR and Heatsink Assemblies
-
Thyro-A-3A-400-350-HF-RL3, Three Phase SCR Controller 350 Amp 400VAC +10/-57%, Phase(VAR), Burst(TAKT) Fire, SWITCH Operating Modes, Voltage Control, Current Feedback Option
Advanced Energy Thyro-A-3A-400-350-HF-RL3, Three Phase SCR Controller 350 Amp 400VAC +10/-57%, Phase(VAR), Burst(TAKT) Fire, SWITCH Operating Modes, Voltage Control, Current Feedback Option Features 400VAC +10/-57% Line to Line Voltage, Current or Power Control Smallest footprint on the market Built in Fuses 3 Phase, Phase Angle & Burst Controller with SWITCH operation mode SWITCH between Phase(VAR) or Burst(TAKT) control modes (0)4-20mA, 0(1)-5V, 0(2)-10V or POT input Proportional Control Removable Cover USB Configuration/Bias Setting Potentiometer Adjustments Synchronisation Function for Multiple TAKT Sync Applications Electrical Ovens, Kilns, or Furnaces Primary Control of Transformer Loads in Phase or Burst Fire mode Resistive Loads up to 6:1 Hot/Cold Ratio AC Soft Starter (VAR Mode Combined with PLC) Power Regulation Applications Electric Boilers Brewery Heating Industrial Light Dimming Suitable for extreme environments such as mining Series Optional Features For HRL Current Control/Feedback Programmable Relay Alarm Output Load Monitoring Analogue Output For HRLP As above with Power Control Feedback Communication Options Standard Thyro Bus Module BasicBus Module Specification Advanced Energy Part Number Thyro-A-3A-400-350-HF-RL3 Approvals CE, UL508A, EU Directive 2014/35/EU & 2004/108/EC Control Accuracy 3% at rated voltage Rated Operating Temperature 45°C Temperature Derating 0.9 x Inom @ 50 Deg C, 1.1 x Inom @ 35 Deg C SCR Configuration Three Phase AC Switch Control Modes Phase(VAR), Burst(TAKT), QUick TAKT(QTM), Hybrid(VT on request) Control Input 4(0)-20mA, 0(1)-5V, 0(2)-10V, POT Load Current 16 to 1500 Amp @ 45 Deg C (110% @ 35 Deg C Max) Control Range 0-100% Options Conformal Coating for Gas or High Humidity Environments Mounting Style Panel Mount Supply Voltage Range 400VAC +10/-57% (-57% with 24VDC Aux Supply) Soft Start Via PLC input Termination Style Screw Unit Weight 2.1 to 74kg Factory Pack Qty 1 Technical Docs Brochure User Manual 2 Leg Control Application Blog Thyro A Series Quick Installation Guide Setting Up Comms on Thyro A Series Controllers Anybus Device Ethernet IP Setup Guide
$8,964.45
$10,578.05 inclGST -
DV 6400, Digital Voltage Transducer, Vpn = 6400V, +/-15...24VDC, 50mA output, 18.5kV Isolation
LEM DV 6400, Digital Voltage Transducer, Vpn = 6400V, +/-15...24VDC, 50mA output, 18.5kV Isolation Features Bandwidth DC to 12kHz Closed loop transducer using Hall effect Digital Transducer (ASIC based) Compact and versatile Panel Mount Insulated plastic case recognized according to UL 94-V0 Advantages Very good linearity High accuracy Low temperature drift Wide frequency bandwidth Very low insertion losses High immunity to external interference Voltage overload capability Low power consumption Applications Railway substation or locomotive AC variable speed drives and servo motor drives Static converters for DC motor drives Battery supplied applications Uninterruptible Power Supplies (UPS) Switched Mode Power Supplies (SMPS) Power supplies for welding applications Water Treatment Electronics Specification LEM Part Number DV 6400 Technology Closed Loop Hall Effect Aperture No Aperture ROHS Yes Supply Voltage +/-15..24 VDC Bipolar, Isolated Primary Nominal Voltage (RMS + DC) +/- 6400V Measurement Range +/- 9500V Output 50 mA @Vpn Isolation 18.5 kV Bandwidth DC-13 kHz Mounting Style Panel Mount Operating Temperature Range -40°C / 85°C Accuracy 1% Termination Style M5 Screw Unit Weight 1000g Factory Pack Quantity 4 Datasheet Product Datasheet Application Notes LEM Applications Manual 3rd Edition
$2,806.00
$3,311.08 inclGST