Risbabh LM1360-MA4L-4-3-01-02-R-H-2, Panel Mount kWh Meter, Class 0.2S, 1/5Amp input, 2 Pulse Outputs, RS485 Comms, Three Section LCD Display
2 Pulse Outputs
Nominal current up to 1.2/6 A (For 1/5A CT Input) and nominal voltage up to 240V L-N
Three Section Display
RS 485 communication up to 19,200 bit/s
RMS values of currents and voltages
Measurements of active, reactive, apparent power and power factor
THD up to 31sth Harmonic
85 Parameter Measurement
The meter is intended for measuring, analysing and monitoring single-phase or three-phase electrical power network. The meter records TRMS value according to the principle of fast sampling of voltage and current signals. A built-in microprocessor calculates measurands (voltage, current, frequency, energy, power, power factor, phase angles, etc.) from the measured signals.
Features :
96 x 96mm Panel Mount
Accuracy class 0.2
Simple Menu
RS 485 communication up to 19,200 bit/s
MODBUS communication protocol
240V AC power supply
Specification
Rishabh Part Number
LM1360-MA4L-4-3-01-02-R-H-2
Functions
kWh Meter, Energy Meter
Supply Voltage
240VAC < 5VA
Nominal Measurement Range
600V L-L 350V L-N, 5 Amp
Maximum Measurement Range
600V L-L 350V L-N, 6 Amp
Display
Three Line LCD
Pulse Output
2 (input or output)
Accuracy
Class 0.2S (kW,kWh) Class 0.5(Active) Class 2(kVar,PF)
Battery Backup
N/A
Real Time Clock
1min/month (30ppm)
Isolation
3.5kV
Ethernet
Modbus RTU Over TCP/IP 2400-19200 b/s
Weight
450g
Certification
EN 61010-1 Installation Category III
Factory Pack Qty
1
Environment
IP54
Safety
Protection Class II
Enclosure Material
Mablex with fire protection to UL94-V-O. Self extinguishing
EnclosureSize
96 x 96mm x 83.5mm (72mm behind panel)
Terminals
Rising Cage 4mm² (12 AWG) cable max
Humidity
< 75% Non Condensing
Operating Temperature
-20 →+70 °C
Datasheet
Product Datasheet
Software
Software User Manual
Software Download Link
Application Notes
1)Reading Data from Registers -> Download file
2)Maximum Memory Size -> Read below
Max Available Memory Locations in 8MB Size = 273030
Actual parameter stored in Each log (Memory locations used) = Date +time+Number of parameter selected by user
Considering your example for 2 parameters:
Number of parameter selected by user = 2 (kwh & kVA)
Actual parameter stored in Each log = 1(Date) +1(time)+ 2 (Parameters) = 4 (memory locations used per log)
Maximum log that can be stored = Max Memory Location/Actual parameter stored in Each log =273030/4= 68257
Timelog Interval setting = 15 minutes
Log in one day = (60 /Timelog Interval setting) * 24 =(60/15)*24 = 96 Logs
Max Days = Maximum log that can be stored / log in one day = 68257 / 96 = 711 days = 1 Year & 11 Months = 23 Months.
LEM DVC 1000-B, C/L Voltage Transducer, 1000V AC/DC Measurement, +/-15...24VDC Supply, Vsn= +/-6.66V, Panel Mount, or Din Rail Mount with Optional Clip
Features
Bandwidth DC to 47kHz
Wago 2061 Connections
+/-15...24VDC Bipolar Supply
Closed loop transducer using Hall Effect
Compact and versatile
Panel Mount or Din Rail Mount with Optional Clip (93.30.R2.000.0)
Insulated plastic case recognized according to UL 94-V0
Advantages
Very good linearity
High accuracy
Low temperature drift
Wide frequency bandwidth
Very low insertion losses
High immunity to external interference
Voltage overload capability
Low power consumption
Applications
AC variable speed drives and servo motor drives
Single and Three Phase Inverters
Static converters for DC motor drives
Battery supplied applications
Uninterruptible Power Supplies (UPS)
Switched Mode Power Supplies (SMPS)
Power supplies for welding applications
Water Treatment Electronics
Specification
LEM Part Number
DVC 1000-B
Technology
Closed Loop Hall Effect
Aperture
No Aperture
ROHS
Yes
Supply Voltage
+/-15...24VDC
Primary Nominal Voltage
+/-1000V AC/DC
Measurement Range
+/-1500V AC/DC
Output
+/-6.66 VDC Instantaneous (+/-10VDC over range)
Isolation
4.2 kV
Bandwidth
DC-37 kHz
Mounting Style
Panel Mount or Din Rail Mount with Optional Clip (93.30.R2.000.0)
Operating Temperature Range
-40°C / 85°C
Accuracy
1%
Termination Style
WAGO 2016 Connectors
Unit Weight
57g
Factory Pack Quantity
25
Datasheet
Product Datasheet
Application Notes
LEM Applications Manual 3rd Edition
Trent NBR-A15QS3000-128, Amp Trap Semiconductor Fuse, 3000 Amp, 150V, Capsule Style, 100kA
Features
Capsule Style
Low I²t
Ratings up to 6000 Amp
Busbar Mounted
Form 101
150 V Voltage Rating complying with IEC 33
Applications
Protection of High Powered Semiconductors according to I²t
Short Circuit Protection
DC or AC Motor I²t Protection
Battery Fuse
Specification
Trent Part Number
NBR-A15QS3000-128
Fuse Type
I²t Amp Trap Form 101
Nominal Voltage
150VAC @ 50Hz /150VDC
I²t Rating (660V)
640000A²/s
Nominal Current (RMS + DC)
3000 Amp
Tested Breaking Capacity
100kA @ 150VAC/DC
Dimensions
⌀41.4 x 47.8
Hole Centers
38.1mm
Mounting Style
Busbar Mount
Operating Temperature Range
-40°C / 125°C
Watts Dissipation
Termination Style
1/2" 20 UNF, 1/2" Deep
Unit Weight
500g
Factory Pack Qty
3
Datasheet
Product Datasheet
Fastron Electronics FAT300D420, AC Current Transducer, 300Amp Measurement, 24mm Split Core, 4-20mA Average RMS Output, Accuracy = 1%
Features
Quick Release 24mm Split Core System
Cale Mount
4-20mA Output
24VDc Aux
Rated System Voltage 0.60/2.5kV
0.5M Flying Leads
Applications
US Based Metering Equipment
Energy Monitoring
AC Power Control Systems
Power Factor Correction
Power Quality Measurements
Specification
Fastron Part Number
FAT300D420
Technology
24mm Split Core AC Current Transformer
Ratio
300/4-20mA
Aperture Size
ø 24 mm
VA Rating
N/A
Accuracy Class
Class 1
Output
4-20mA (+20%)
Isolation
2.5kV (AC, 50Hz, 1 min)
Bandwidth
50-60Hz
Mounting Style
Cable Mount/Busbar Mount
Operating Temperature Range
-15°C / 45°C
Continuous Current (max)
300Amp x 1.2
Termination Style
0.5M Flying leads
Unit Weight
300g
Factory Pack Qty
9
Datasheet
Product Datasheet
Application Notes
Installation Guide
Rishabh DS96/100A/75mVDC Direct Connect Moving Coil Ammeter
Features
Adjustable Display Scaling
PC 94 UL V0
For robust Measurement
Each unit needs just 72 x 72mm Panel Space
65mm Depth
Specification
Rishabh Part Number
DS96/100A/75mV
Nominal Measurement Range
0 - 100 Amp DC
Shunt Input
0-75mV Unipolar
Maximum Measurement Range
100 AmpDC
Over Range
Ipn x 2
Operating Temperature
0 - 50°C
Frequency
15...100Hz
Safety Rating
IP52 case, IP20 terminals wiht back cover
Termination Style
Screw
Mounting Style
72 x 72mm Panel Mount
Case Material
PC - UL 94 V0
Weight
320g
Factory Pack Qty
1
Datasheet
Product Datasheet
Rishabh DS96/400A/75mV DC Direct Connect Moving Coil Ammeter
Features
Adjustable Display Scaling
PC 94 UL V0
For robust Measurement
Each unit needs just 72 x 72mm Panel Space
65mm Depth
Specification
Rishabh Part Number
DS96/400A/75mV
Nominal Measurement Range
0 - 400 Amp AC
Shunt Input
0-75mV Unipolar
Maximum Measurement Range
400 Amp
Over Range
Ipn x 2
Operating Temperature
0 - 50°C
Frequency
15...100Hz
Safety Rating
IP52 case, IP20 terminals wiht back cover
Termination Style
Screw
Mounting Style
72 x 72mm Panel Mount
Case Material
PC - UL 94 V0
Weight
320g
Factory Pack Qty
1
Datasheet
Product Datasheet
Rishabh DS72/500A/75mV, Moving Coil Ammeter 500Amp DC for 500A/75mV Shunt Connect
Features
Adjustable Display Scaling
PC 94 UL V0
For robust Measurement
Each unit needs just 72 x 72mm Panel Space
65mm Depth
Specification
Rishabh Part Number
DS72/500A/75mV
Nominal Measurement Range
0 - 500 Amp AC
Shunt Input
0-75mV Unipolar
Maximum Measurement Range
500 Amp
Over Range
Ipn x 2
Operating Temperature
0 - 50°C
Frequency
15...100Hz
Safety Rating
IP52 case, IP20 terminals with back cover
Termination Style
Screw
Mounting Style
72 x 72mm Panel Mount
Case Material
PC - UL 94 V0
Weight
320g
Factory Pack Qty
1
Datasheet
Product Datasheet
LEM ART-B22-D70-SP3 + AI-PMUL - 3Pcs, 3 Phase Rogowski Coils & Universal Multi Range Integrator with Signal Conditioner
The universal Rogowski coil integrator AI-PMUL complements LEM’s flexible clip-around coil ART and ARU range. The design is based on digital processing to give combined dynamic range, accuracy and versatility of use. It offers a wide range of output signals both RMS and instantaneous. AI-PMUL is DIN rail mounted and can be stacked for multiphase application without spacing thanks to its low power dissipation.
Input signal
Accuracy Class 1 (IEC 61869-2) [1].
Linearity error ≤ 0.10 %. Protection degree IP2X.
35 mm DIN rail mounted.
Push-in terminals.
4 selectable true RMS output signals: 0…20 mA, 4…20 mA, 0…5 V, 0…10 V.
2 selectable instantaneous output signals: 225 mV, 333 mV.
6 selectable sensitivities depending on Rogowski coil: 22.5, 70, 80, 85, 100, 120 mV/kA at 50 Hz.
12 selectable ranges: 100, 200, 300, 400, 500, 600, 800, 1000, 1500, 2000, 4000, 5000 A.
Ambient operating temperature −25...+70 °C.
Advantages
Compact design for DIN rail assembly
High accuracy Class 1 (IEC 61869-2)
Setup by user via Select / Edit buttons
Clear status indication via bi-color led
Applications
MV/LV substations on LV side: Transformer Condition Monitoring
Power metering: current measurement for active power calculation
Building sub-metering: energy efficiency monitoring, consumption analysis and cost allocation
Power quality monitoring: electrical loads and distribution system equipment
Fault Detection, Isolation and Repair (FDIR): isolate the site of the fault
Remote Terminal Units (RTU)
Phasor Measurement Units (PMU)
Standards
IEC 61010-1: 2010
UL
EMC: IEC 61326-1:2012
Included Options
Cross Power Plug-in: side contacts to stack up to 3 Integrator modules and use only one power supply.
Specification
LEM Part Number
ART-B22-D70-SP3 + AI-PMUL - 3Pcs
Function
3 Phase AC Current Measurement
Measuring Range
Selectable 5000,4000,2000,1500,1000,800,600,500,400,300,200,100Amp
Sensitivity
Selectable 22.5,70,80,85,100,120mV/kA @ 50 Hz
Output
Selectable; Signal Conditioned True RMS 0-20mA, True RMS 4-20mA, True RMS 5V, True RMS 10V or 225mV, 333mV Direct Output (1 Amp output coming soon)
Frequency Measuring Range
50-1500Hz (15th Harmonic)
Operating Voltage
10-32VDC
Accuracy
1% from 25 to 5000 Amp
Current Consumption
100mA (max)
Dimensions
100mm x 78mm x 15mm (Integrator), 7cm Diameter (Coils)
Mounting
Din Rail Mount
Integrator to Coil cable
3M Twisted and Screened
Integrator to Meter cable
User Supplied Shielded cable 1.5mm sqr, up to 6m long
Operating Temperature
-25°C - 70°C
Storage Temperature
-45°C to 80°C
Isolation (50Hz, 1 min)
1.5kV
True RMS Response Time
160-190ms
Termination Style
Push-in for 1.5mm sqr wire
Weight
58g
Factory Pack Qty
1
Certifications
UL, ROHS
Datasheet
AI-PMUL Datasheet
ART Series Datasheet
Applicaton Notes
User Notice
1) The Rogowski coil can measure any primary current as there is no saturation effect.
2) Not tested given that in the worst case (load = 0 Ohm i.e. short circuit on the output) the peak dissipated power remains low (< 2 Watts)
3) Frequency bandwidth and phase shift modelling schematic can be provided on request.
4) Referring to the main phase offset of 90 ° (a Rogowski coil is a derivative current transducer)
5) Considering a primary conductor of at least ⌀ 15 mm, perpendicular and in contact with the Rogowski coil.
6) Considering an external conductor of at least ⌀ 15 mm the same current level than internal conductor, perpendicular and in contact with the Rogowski coil.
Fastron Electronics F41F-1Z-C4-1-12VDC, Slim Relay & Socket with Spring Terminals 12VDC Input, 6 Amp @ 30VDC/250VAC
Features
Multirange input 12VDC Nominal
Load Rating 6 Amp @ 30VDC/250VAC
DIN Rail Mount
Changeover Contact
Ultra slim package
UL Listed (Hongfa make)
CE Compliant to IEC 60664
IP67
Specification
Fastron Part Number
F41F-1Z-C4-1-12VDC
Switching Type
250VAC or 30VDC Load
Control Input
12V DC+/-10%
Current @ Rated Voltage
6 Amp
Contact Arrangement
1 C/O (Single Pole Changeover)
Approvals
UL, CE
Dimensions
76.6 x 94.7 x 6.2
Ingress Protection
IP20
Coils Power
12mA
Relay Type
Fastron F41F-24Z
Termination Style
Spring Terminals
Unit Weight
60g
Factory Pack Qty
100
Datasheet
Datasheet
Fastron/Hongfa F41F-12Z, Slimline Relay, 12VDC Coil, 6 Amp
Features
Output 6Amp @ 30VDC or 250VAC
12DC Control input
DIN Rail Mount
Changeover Contact
Ultra slim package
CE Compliant to IEC 60664
IP67
Specification
Fastron Part Number
F41F-12Z
Switching Type
250VAC, 30VDC Load C/O Relay Contact
Approvals
UL, CE
ROHS
Yes (Details)
Control Voltage
12VDC Nominal
Load Current
6 Amp (rms)
Special Feature
LED Status Indicator
Mounting Style
Socket Mount (F41F-1Z-C2-5 12-24VAC/DC)
Load Voltage Range
250VAC, 30VDC Load
EMC Compliant
Level 3
Termination Style
PCB or Socket Mount
Unit Weight
6g
Factory Pack Qty
20
Datasheet
Relay & Base Datasheet
F41F-1Z-C2-5 12-14VAC/DC Socket
Fastron Electronics Slimline Relay & Socket with Screw Terminals, UL, CE Approved F41F-1Z-C2-1-12VDC, Slim Relay & Socket with Screw Terminals 12VDC Coil, 6 Amp @ 30VDC/250VAC
Features
Multirange input 12VDC Nominal
Load Rating 6 Amp @ 30VDC/250VAC
DIN Rail Mount
Changeover Contact
Ultra slim package
UL Listed (Hongfa make)
CE Compliant to IEC 60664
IP67
Specification
Fastron Part Number
F41F-1Z-C2-1-12VDC
Switching Type
250VAC or 30VDC Load
Control Input
12VDC +/-10%
Current @ Rated Voltage
6 Amp
Contact Arrangement
1 C/O (Single Pole Changeover)
Approvals
UL, CE
Dimensions
76.6 x 94.7 x 6.2
Ingress Protection
IP20
Coils Power
12mA
Relay Type
Fastron F41F-24Z
Termination Style
Screw
Unit Weight
60g
Factory Pack Qty
100
Datasheet
Datasheet
Crydom CWU4890P, Solid State Relay, Single Phase 20-48VDC or 20-280VAC Control, 90A, 48-530VAC Load, High Surge Rating w/status LED + Overvoltage Protection
Features
Ratings from 25A to 125 Amp @48-600VAC
SCR output for heavy industrial loads
Zero voltage or instantaneous turn-on outputs
UL/CSA/VDE Approved, CE Compliant to EN60950-1
Improved SEMS screw and washer
Redesigned housing with anti-rotation barriers
AC & DC control types
Direct bond copper substrate
EMC compliant to Level 3
Direct power lead frame
Epoxy free design
Spec
Crydom Part Number
CWU4890P
Switching Type
Zero Crossing
ROHS
Yes (Details)
Control Voltage
20-48VDC or 20-280VAC
Load Current
90 Amp (rms)
Surge Capability
1290 Amp (peak)
Special Feature
LED Status Indicator, High Surge, Internal Over Voltage Protection
Mounting Style
Panel Mount
Load Voltage Range
48-660VAC
EMC Compliant
Level 3
Termination Style
Screw
Unit Weight
75g
Factory Pack Qty
20
Datasheet
Product Datasheet
Notifications
Please note Changes from Gen 3 to Gen 4 (current) package design here
Equivalent
See CWA2450P, CWD2450P, CWA4890P CWD4890H for stocked equivalent (no overvoltage protection).
App Notes
Why Use SSR's?
The inside story
Selecting a SSR
DC Output SSR's
Selecting a Suitable Heatsink
Use of Thermal Interface Material
How to Verify the Proper Heatsink
Effect of Forced Air Cooling
Fuse Protection of SSR's
Overvoltage Protection "P" Option MOV
SSR Reliability Whitepaper
3 Phase Motors and Heating Applications
3 Phase Motor Reversing
How to test a SSR
SSR Precautions
SSR Life Expectancy MTBF
ROHS & Reach Statement
Heatsink
SSR and Heatsink Assemblies