Fastron Electronics SCT-F24-200-1A, Amp, 200/1Amp measurement Split Core CT's
Features
Quick Release Split Core System
Cable Mount
1 Amp Output
Self Powered
Rated System Voltage 0.60/3kV
0.9M Flying Leads
Applications
US Based Metering Equipment
Energy Monitoring
AC Power Control Systems
Power Factor Correction
Power Quality Measurements
Specification
Fastron Part Number
SCT-F24-200-1A
Technology
Split Core AC Current Transformer
Ratio
200/1 Amp
Aperture Size
ø 24 mm
VA Rating
N/A
Accuracy Class
Class 1
Output
5 Amp (+20%)
Isolation
3kV (AC, 50Hz, 1 min)
Bandwidth
50-60Hz
Mounting Style
Cable Mount/Busbar Mount
Operating Temperature Range
-15°C / 45°C
Continuous Current (max)
200Amp x 1.2
Termination Style
0.9M Flying leads
Unit Weight
100g
Factory Pack Qty
9
Datasheet
Product Datasheet
Application Notes
Installation Guide
Gigavac GX11LCB, Contactor SPST-NO, 150+ AMP, 12-800VDC, 240VAC Coil, 122cm Flying leads, SPST-NO Auxiliary Contact, IP67, IP69K
Features
Hermetically Sealed (Patented) rated to 175 Deg C
UL1604 for Class I & II Div 2 and Class III for use in hazardous locations
IP67 & IP69K
SAE J1171 External ignition protection
ISO8846 Protection against ignition around flammable gasses
CE Approved
High Efficiency Dual DC Coils - Very low 12,24,48,72,120VDC, or 120,240VAC continuous coil power with no EMI emissions or cross-talk on your system control power
Ideal for battery powered systems or where low power is needed
PWM option provides additional drive control flexibility
Built in Coils suppression for all DC Coils
Flexible package for installation
Chassi level power terminals
Salt Fog MIL-STD-810
Specification
Gigavac Part Number
GX11LCB
Main Contact Type
SPST-NO
Auxiliary Contact Type
SPST-NO
Coil Voltage
240VAC
Load Current
150+ Amp
Mechanical Life @ 0 Amp
1,000,000 Operations
Dielectric at Sea Level (leakage <1mA)
2.2kV rms
Control Input Terminals
122cm Flying Leads
Special Feature
Hermetically Seal rated to 175 Deg C
Mounting Style
Panel Mount (M5)
Load Voltage Range
12-800VDC
Standards
UL1604, IP67, IP69K, SAE J1171, ISO8846
Termination Style
M8
Unit Weight
440g
Factory Pack Qty
1
Datasheet
Product Datasheet
Equivalent Parts
Gigavac GX11LAB, Contactor SPST-NO, 150+ AMP, 12-800VDC, 240VAC Coil, 38cm Flying leads, SPST-NO Auxiliary Contact, IP67, IP69K
Features
Hermetically Sealed (Patented) rated to 175 Deg C
UL1604 for Class I & II Div 2 and Class III for use in hazardous locations
IP67 & IP69K
SAE J1171 External ignition protection
ISO8846 Protection against ignition around flammable gasses
CE Approved
High Efficiency Dual DC Coils - Very low 12,24,48,72,120VDC, or 120,240VAC continuous coil power with no EMI emissions or cross-talk on your system control power
Ideal for battery powered systems or where low power is needed
PWM option provides additional drive control flexibility
Built in Coils suppression for all DC Coils
Flexible package for installation
Chassi level power terminals
Salt Fog MIL-STD-810
Specification
Gigavac Part Number
GX11LAB
Main Contact Type
SPST-NO
Auxiliary Contact Type
SPST-NO
Coil Voltage
240VAC
Load Current
150+ Amp
Mechanical Life @ 0 Amp
1,000,000 Operations
Dielectric at Sea Level (leakage <1mA)
2.2kV rms
Control Input Terminals
38cm Flying Leads
Special Feature
Hermetically Seal rated to 175 Deg C
Mounting Style
Panel Mount (M5)
Load Voltage Range
12-800VDC
Standards
UL1604, IP67, IP69K, SAE J1171, ISO8846
Termination Style
M8
Unit Weight
440g
Factory Pack Qty
1
Datasheet
Product Datasheet
Equivalent Parts
Fastron Electronics GT-DVO(5-15V)A-1, Signal Isolator/DC Voltage Transducer, 5-15VDC input for Battery Voltage Monitoring, 100 - 240VAC/DC aux, 4-20mA output
Adjustable Zero and Span Setting
250mS Response Time
PC 94 UL V0
Input signals can be converted to insulated 4 to 20 mA DC output (for direct current output type)
Each unit needs just 22.5 x 114 mm depth DIN Rail cabinet space
Specification
Fastron Electronics Part Number
GT-DVO(5-15V)A-1
Control Output
4-20mA
Input
5-15VDC
Over Range
x 1.5
Operating Temperature
0 - 60°C
Load Voltage
100 - 240VAC/DC
Span Adjustment Range
+/-10%
Zero Adjustment Range
+/-5%
Termination Style
Screw
Mounting Style
DIN Rail Mount
Case Material
PC - UL 94 V0
Weight
170g
Factory Pack Qty
1
Datasheet
Product Datasheet
Fastron Electronics GT-DVO(5-15V)D-1, Signal Isolator/DC Voltage Transducer, 5-15VDC input, 22-60VAC/DC aux, 4-20mA output
Adjustable Zero and Span Setting
250mS Response Time
PC 94 UL V0
Input signals can be converted to insulated 4 to 20 mA DC output (for direct current output type)
Each unit needs just 22.5 x 114 mm depth DIN Rail cabinet space
Specification
Fastron Electronics Part Number
GT-DVO(5-15V)D-1
Control Output
4-20mA
Input
5-15VDC
Over Range
x 1.5
Operating Temperature
0 - 60°C
Load Voltage
100 - 240VAC/DC
Span Adjustment Range
+/-10%
Zero Adjustment Range
+/-5%
Termination Style
Screw
Mounting Style
DIN Rail Mount
Case Material
PC - UL 94 V0
Weight
170g
Factory Pack Qty
1
Datasheet
Product Datasheet
Fastron Electronics SCT-F24-75-5A-CL2, 5 Amp, 75Amp measurement Split Core CT's CLASS 2 Series Current Transformer
Features
Quick Release Split Core System
Cable Mount
5 Amp Output
Self Powered
Rated System Voltage 0.60/3kV
0.9M Flying Leads
Applications
US Based Metering Equipment
Energy Monitoring
AC Power Control Systems
Power Factor Correction
Power Quality Measurements
Specification
Fastron Part Number
SCT-F24-75-5A-CL2
Technology
Split Core AC Current Transformer
Ratio
75/5 Amp
Aperture Size
ø 24 mm
VA Rating
N/A
Accuracy Class
Class 2
Output
5 Amp (+20%)
Isolation
3kV (AC, 50Hz, 1 min)
Bandwidth
50-60Hz
Mounting Style
Cable Mount/Busbar Mount
Operating Temperature Range
-15°C / 45°C
Continuous Current (max)
75Amp x 1.2
Termination Style
0.9M Flying leads
Unit Weight
100g
Factory Pack Qty
9
Datasheet
Product Datasheet
Application Notes
Installation Guide
Gigavac HXNC241CAB, Normally Closed Contactor SPST-NC 200 Amp 1500VDC, 24VDC Coil, 38cm Flying leads, with SPST-NO Auxiliary Contact Continuous Duty, IP67, IP69K
Features
Hermetically Sealed (Patented) rated to 175 Deg C
UL1604 for Class I & II Div 2 and Class III for use in hazardous locations
IP67 & IP69K
SAE J1171 External ignition protection
ISO8846 Protection against ignition around flammable gasses
CE Approved
High Efficiency Dual DC Coils - Very low 12,24,48VDC continuous coil power with no EMI emissions or cross-talk on your system control power
Ideal for battery powered systems or where low power is needed
PWM option provides additional drive control flexibility
Built in Coils suppression for all DC Coils
Flexible package for installation
Chassi level power terminals
Salt Fog MIL-STD-810
Specification
Gigavac Part Number
HXNC241CAB
Main Contact Type
SPST-NC
Auxiliary Contact Type
SPST-NO
Coil Voltage
24VDC
Load Current
200 Amp
Mechanical Life @ 0 Amp
1,000,000 Operations
Dielectric at Sea Level (leakage <1mA)
5.375kV rms
Control Input Terminals
38cm Flying Leads
Aux Contact Terminals
38cm Flying Leads
Special Feature
Hermetically Seal rated to 175 Deg C
Mounting Style
Panel Mount (M5)
Load Voltage Range
1500VDC
Standards
UL1604, IP67, IP69K, SAE J1171, ISO8846, CE
Termination Style
M8
Unit Weight
440g
Factory Pack Qty
1
Datasheet
Product Datasheet
Fastron Electronics CJ19-95A, Capacitor Duty Contactor 240/480/530VAC @ 27, 50, 50 kVar, 100,000 Operations, AC-6B
Capacitor duty contactors are designed to meet the requirements of capacitor duty applications. Contactors are fitted with a block of three auxiliary contacts connected in series with six quick discharge damping resistors, two per each phase. Peak current is limited to the value within the contactor making capacity.
Features :
Capacitor Duty
Discharge Resistors
Three-pole contactors
Seven ratings from 12,5 kVAr to 60 kVAr
IEC 60947-4-1 for AC-6b utilization category
UL Approved
Advantages :
Conforms to utilization category AC-6b
Saves costs of expensive replacement
Long electrical life
Reduces watt losses during “ON” condition, saves energy
High safety
No risk of dangerous voltage
Switching of capacitor bank in parallel without de-rating
Less maintenance and downtime
Standard control voltages: 24 V 50/60 Hz, 220 V 50/60 Hz, 230 V 50/60 Hz, 415 V 50/60 Hz
Specification
Fastron Part Number
CJ19-95A
Functions
3 Pole Capacitor Duty Contactor
Nominal Voltage
230/480/530VAC @ 50Hz
Current Carrying Capacity as per UL
27kVar/Amp @230VAC, 50kVar/Amp@480VAC, 50kVar/Amp@530VAC, AC-6B
Auxiliary Contacts
2 x NO and 2 x NC
Trip Delay Time
2-10ms
Electrical Life
100,000 Ops
Operating Temperature
-25 to 40 Deg C
Mechanical Operations
1,000,000 Ops
Control Voltage
230VAC
Power Dissipation
5.1W
Approvals
UL
Standards
IEC/EN 60947-4-1, AS/NZ 61009-1, AC-6B
Weight
200g
Enclosure Material
UL94
Factory Pack Qty
1
Datasheet
Product Datasheet
Application Notes
Discharge Resistor Usage
Power Factor Correction Blog
LEM HO 200-S-0100, O/L Hall Effect AC/DC Current Sensor, 200 Amp, 15 x 8mm Aperture, Vref = 2.5V, Panel Mount
Features
Open loop current transducer
Voltage output
Single power supply +5 V
Overcurrent detect 2.93 × IP N (peak value)
Galvanic separation between primary and secondary circuit
Low power consumption
Factory calibrated
Compact design for panel mounting
Aperture: 15 × 8 mm
Factory calibrated
Repositionabel mounting foot
Dedicated parameter settings available on request
Advantages
Low offset drift
Over-drivable Vref
Creepage / clearance > 8 mm
Fast response
Applications
AC variable speed and servo motor drives
Static converters for DC motor drives
Battery supplied applications
Uninterruptible Power Supplies (UPS)
Switched Mode Power Supplies (SMPS)
Power supplies for welding applications
Combiner box
Solar inverter on DC side of the inverter (MPPT).
Standards
IEC 61800-1: 1997
IEC 61800-2: 2015
IEC 61800-3: 2004
IEC 61800-5-1: 2007
IEC 62109-1: 2010
UL 508: 2013.
Application Domain
Industrial.
Specification
LEM Part Number
HO 200-S-0100
Technology
Open Loop Hall Effect
Aperture
15 x 8mm
ROHS
Yes
Supply Voltage
5 VDC
Load Current (RMS + DC)
200 Amp
Measurement Range
+/-500 Amp
Output
2.5 Vref
Isolation
4.3 kV
Bandwidth
DC-100 kHz
Mounting Style
Panel Mount
Operating Temperature Range
-40°C / 105°C
Accuracy
1%
Termination Style
JST B5B-PH type
Unit Weight
32g
Factory Pack Quantity
25
Datasheet
Product Datasheet
Application Notes
LEM Applications Manual 3rd Edition
Westcode-IXYS-Littlefuse W3270NC160, Diode PUK, 2670 Amp @ 85 Deg C, 2200V, 74/26
Features
Very low forward voltage drop
Very low leakage current
International standard package
74/26 Package
Press Mounted
Double or Single Sided Cooling
Applications
Replaces ABB # 5SDA 24F2303
Power Supplies
Rectifier for drives applications
Controlled Rectifiers
AC Switch
Battery Chargers
Phase Controllers
Water Cooled AC switches
Power Factor Correction
Specification
Westcode Part Number
W3270NC160,
Vrrm
1600V
SCR Configuration
Diode Capsule PUK
IF(av) @ 100 Deg C
2670 Amp
Package Size
ø74 x 26mm
Itsm
27.6 kA
VF(to)
0.818V
Tj(max)
175°C
rF
0.108mΩ
Gate Terminals
N/A
R th(j-k) (double sided cooled 180°sin)
0.022°C/W
R th(c-h) (double sided cooled)
Weight
510g
Clamping Force
19 - 26kN
Factory Pack Qty
2
Certification
ROHS
Westcode-IXYS-Littlefuse Headquarters
USA
Datasheet
Product Datasheet
Alternatives
Contact Us for Possible Replacement
Heatsink
Heatsink Profiles
Fastron Electronics BTCR/R-M1-A2-DS-C5, PID Controller 48x96mm, 15-50VDC, Relay Output 2 Alarms, SSR Cooling, RS485 Modbus Comms, Multirange TC/RTD/4-20mA Input
4-digit displays suit most industries including Temperature, Humidity, Pressure (0.5s response)
Dust-proof IP56 (front panel only)
Optional 32-step pattern (for SV and time) is a standard feature
CE Approved
Each unit needs just 80 mm depth panel space
Specification
Fastron Electronics Part Number
BTCR/R-M1-A2-DS-C5
Control Output
Relay 3 Amp (Resistive)
Input
Multirange TC/RTD/4-20mA (Optional Linear voltage/current other than 4-20mA. Refer to datasheet)
Option 1
2nd Alarm
Option 2
RS485 Modbus RTU, SSR Cooling
Mounting Style
48 x 96mm Panel Mount
Load Voltage Range
15-50VDC
Termination Style
Screw
Weight
450g
Factory Pack Qty
1
Yes
UL
Yes
CE
Yes
Datasheet
BTC Series Brochure
BTC Series User Manual
BTC Series RS485 Comms Manual
Fine Tuning PID Adjustments
Fastron Electronics BTCR/R-M-A2-DR, PID Controller 48x96mm, 85-265VAC, Relay Output, Relay Cooling Output, 2 Alarms, Multirange TC/RTD/4-20mA Input
4-digit displays suit most industries including Temperature, Humidity, Pressure (0.5s response)
Dust-proof IP56 (front panel only)
Optional 32-step pattern (for SV and time) is a standard feature
CE Approved
Each unit needs just 80 mm depth panel space
Specification
Fastron Electronics Part Number
BTCR/R-M-A2-DR
Control Output
Relay 3 Amp (Resistive)
Input
Multirange TC/RTD/4-20mA (Optional Linear voltage/current other than 4-20mA. Refer to datasheet)
Option 1
2nd Alarm
Option 2
Relay Cooling
Mounting Style
48 x 96mm Panel Mount
Load Voltage Range
100-240VAC
Termination Style
Screw
Weight
450g
Factory Pack Qty
1
Yes
UL
Yes
CE
Yes
Datasheet
BTC Series Brochure
BTC Series User Manual
BTC Series RS485 Comms Manual
Fine Tuning PID Adjustments