Fastron TC5-L-1A-2-T/R-2 PID Controller, 100-240VAC with 2 3 Amp Relay Alarms, K,E,J Thermocouple, Pt100 or Cu20, Optional Linear Current/Voltage, 96x96mm,4-20mA Output
4-digit displays (0.5s response)
Drip-proof / Dust-proof IP66 (front panel only)
Input signals can be converted to insulated -0-10V, Relay, 12VDC (SSR) and 4 to 20 mA DC outputs available
Each unit needs just 75 mm depth panel space
Now available will full Multirange input (K,E,J,N,T,S,R,B Thermocouple, Linear Current/Voltage and PT100/Cu20 RTD Input, 96x48mm,4-20mA Output)
Fastron Part Number
TC5-L-1A-2-T/R-2
Control Output
4-20mA
Input
Multirange Type,K,E,J, Pt100, Cu50/(Optional)Linear Current 4(0)-20mA/(Optional)Linear Voltage 0-10(5)V
Option 1
2 3 Amp Relay Alarms standard (Excludes 96x96mm with SSR/Relay output)
Mounting Style
96x96mm Panel Mount
Supply Voltage
100 - 240VAC +/-10%
Termination Style
Screw
Sampling Time
100ms
Weight
150-270g
Factory Pack Qty
10
Datasheet
TC5 Datasheet and User Manual
Fastron TC5-S-1U-2-G-2, PID Controller, 100-240VAC with 2 3 Amp Relay Alarms, K,E,J,N,T,S,R,B Thermocouple, Linear Current/Voltage and PT100/Cu20 RTD Input, 0-10VDC Ouput
4-digit displays (0.5s response)
Drip-proof / Dust-proof IP66 (front panel only)
Input signals can be converted to insulated -0-10V, Relay, 12VDC (SSR) and 4 to 20 mA DC outputs available
Each unit needs just 75 mm depth panel space
Specification
Fastron Part Number
TC5-S-1U-2-G-2
Control Output
0-10V
Input
Multirange Type,K,E,J, Pt100, Cu50/(Optional)Linear Current 4(0)-20mA/(Optional)Linear Voltage 0-10(5)V
Option 1
2 3 Amp Relay Alarms standard (Excludes 48x48mm with SSR/Relay output)
Mounting Style
48 x 48mm Panel Mount
Supply Voltage
100 - 240VAC +/-10%
Termination Style
Screw
Sampling Time
100ms
Weight
150-270g
Factory Pack Qty
10
Datasheet
TC5 Datasheet and User Manual
Fastron TC5-S-S-2-G-2 PID Controller, 100-240VAC with 2 3 Amp Relay Alarms, Multirange Type K,E,J,N,T,S,R,B Thermocouple, Linear Current/Voltage and PT100/Cu20 RTD Input, Pt100 or Cu20, 48x48mm,12VDC Output
4-digit displays (0.5s response)
Drip-proof / Dust-proof IP66 (front panel only)
Input signals can be converted to insulated -0-10V, Relay, 12VDC (SSR) and 4 to 20 mA DC outputs available
Each unit needs just 75 mm depth panel space
Specification
Fastron Part Number
TC5-S-S-2-G-2
Control Output
12VDC
Input
Multirange Multirange Type K,E,J,N,T,S,R,B Thermocouple, Linear Current/Voltage and PT100/Cu20 RTD Input
Option 1
2 3 Amp Relay Alarms standard (Excludes 48x48mm with SSR/Relay output)
Mounting Style
48 x 48mm Panel Mount
Supply Voltage
100 - 240VAC +/-10%
Termination Style
Screw
Sampling Time
100ms
Weight
150-270g
Factory Pack Qty
10
Datasheet
TC5 Datasheet and User Manual
Fastron TC5-L-1U-2-G-2 PID Controller, 100-240VAC with 2 3 Amp Relay Alarms, K,E,J,N,T,S,R,B Thermocouple, Linear Current/Voltage and PT100/Cu20 RTD Input, 96x96mm,0-10V Output
4-digit displays (0.5s response)
Drip-proof / Dust-proof IP66 (front panel only)
Input signals can be converted to insulated -0-10V, Relay, 12VDC (SSR) and 4 to 20 mA DC outputs available
Each unit needs just 75 mm depth panel space
Specification
Fastron Part Number
TC5-L-1U-2-G-2
Control Output
0-10V
Input
Multirange Type K, J, E,S,T,R, Pt100, Cu50/Linear Current 4(0)-20mA/Linear Voltage 0-10(5)V
Option 1
2 3 Amp Relay Alarms standard (Excludes 96x96mm with SSR/Relay output)
Mounting Style
96x96mm Panel Mount
Supply Voltage
100 - 240VAC +/-10%
Termination Style
Screw
Sampling Time
100ms
Weight
150-270g
Factory Pack Qty
10
Datasheet
TC5 Datasheet and User Manual
Fastron FJTY220D80P, Single Phase Intelligent Phase or Burst Control Module with 2 second Soft Start, 4-20mA,0-10V,0-5V,10K POT Input, 220VAC, 80 Amp Per Phase, Voltage Regulator
4-20mA,0-10V, 0-5V or 10K POT Proportional Phase Control Input
Ratings from 25A to 80 Amp @ 180-280 VAC
SCR output for heavy industrial loads
Instantaneous turn-on output
Direct bond copper substrate
Direct power lead frame
Epoxy free design
Specification
Trent part Number
FJTY220D80P
Switching Type
Phase Angle (Random Crossing)/ Burst Fire (10 cycles)
Control Voltage
4-20mA,0-10V,0-5V,10K POT Proportional Input
Load Current
80 Amp (rms)
Surge Capability
690Amp (peak)
Special Feature
Single Phase Proportional Controller + 2 Second Soft Start + Selectable Half Wave control
Mounting Style
Panel Mount
Load Voltage Range
170-220VAC +15% (253VAC Max)
Max Non Repetitive Peak Voltage
600 Vp
Termination Style
Barrier Strip Screw
Dimensions
105 x 80 x 55mm
Unit Weight
400g
Factory Pack Qty
20
Datasheet
FJTY Series Voltage Regulators
Rishabh DS96/150A/75mV, Moving Coil Ammeter 150Amp DC for 150A/75mV Shunt Connect
Features
Adjustable Display Scaling
PC 94 UL V0
For robust Measurement
Each unit needs just 96 x 96mm Panel Space
65mm Depth
Specification
Rishabh Part Number
DS96/150A/75mV
Nominal Measurement Range
0 - 150 Amp AC
Shunt Input
0-75mV Unipolar
Maximum Measurement Range
150 Amp
Over Range
Ipn x 2
Operating Temperature
0 - 50°C
Frequency
15...100Hz
Safety Rating
IP52 case, IP20 terminals wiht back cover
Termination Style
Screw
Mounting Style
96 x 96mm Panel Mount
Case Material
PC - UL 94 V0
Weight
320g
Factory Pack Qty
1
Datasheet
Product Datasheet
Crydom D2D40, Solid State Relay, DC 3-32VDC control, 40A, 200VDC Load
Features
Ratings from 7A to 100 Amp @ 100-500VDC
Mosfet output for reliable DC switching
Multiple modules can be wired in parallel for higher currents
UL/CSA/VDE Approved, CE Compliant to EN60950-1
Improved SEMS screw and washer
Redesigned housing with anti-rotation barriers
Direct bond copper substrate
EMC compliant to Level 3
Direct power lead frame
Epoxy free design
Spec
Crydom Part Number
D2D40
Switching Type
DC Load
ROHS
Yes (Details)
Control Voltage
3.5-32VDC
Load Current
40 Amp DC
Surge Capability (10ms)
106 Amp DC
Special Feature
None
Mounting Style
Panel Mount
Load Voltage Range
0 - 200VDC (max) 0-144VDC (Nominal)
EMC Compliant
Level 3
Termination Style
Screw
Unit Weight
75g
Factory Pack Qty
20
Datasheet
Product Datasheet
Notifications
Please note Changes from Gen 3 to Gen 4 (current) package design here
Equivalent
See alternative DC500D60 with raised terminals for alternative or D1D80 for higher current alternative
App Notes
Why Use SSR's?
The inside story
Selecting a SSR
DC Output SSR's
Selecting a Suitable Heatsink
Use of Thermal Interface Material
How to Verify the Proper Heatsink
Effect of Forced Air Cooling
Fuse Protection of SSR's
Overvoltage Protection "P" Option MOV
SSR Reliability Whitepaper
3 Phase Motors and Heating Applications
3 Phase Motor Reversing
How to test a SSR
SSR Precautions
SSR Life Expectancy MTBF
ROHS & Reach Statement
Heatsink
SSR and Heatsink Assemblies
Crydom MCPC2425C, Solid Sate Relay based Phase Angle Controller,170-280VAC, 25 Amp, 0-10V Input
Features
Selectable Proportional Burst Control Input
Ratings from 25A to 90 Amp @ 180-530 VAC
SCR output for heavy industrial loads
Zero voltage turn-on outputs
UL/CE/ROHS Compliant
Direct bond copper substrate
Direct power lead frame
Epoxy free design
Spec
Crydom Part Number
MCPC2425C
Switching Type
Phase Angle
ROHS/CE/UL
Yes
Control Voltage
0-10V Proportional Input Requires DC Power Supply
Load Current
25 Amp (rms)
Surge Capability
397Amp (peak)
Special Feature
Proportional Controller + SSR
Mounting Style
Panel Mount
Load Voltage Range
170-280VAC
Overvoltage Vpk
1200V
Termination Style
Terminal Plug & Screws
Unit Weight
87g
Factory Pack Qty
10
Datasheet
Product Datasheet
Notifications
Please note Changes from Gen 3 to Gen 4 (current) package design here
Equivalent
Crydom PMP2450W or Contact Us for Possible Replacement
App Notes
Why Use SSR's?
The inside story
Selecting a SSR
DC Output SSR's
Selecting a Suitable Heatsink
Use of Thermal Interface Material
How to Verify the Proper Heatsink
Effect of Forced Air Cooling
Fuse Protection of SSR's
Overvoltage Protection "P" Option MOV
SSR Reliability Whitepaper
3 Phase Motors and Heating Applications
3 Phase Motor Reversing
How to test a SSR
SSR Precautions
SSR Life Expectancy MTBF
ROHS & Reach Statement
HS151DR-D2475, Din Rail Mount Solid State Relay with Heatsink, 4-32VDC Control Input, 24-280VAC Output, 42 Amps @ 40 Deg C ambient
4-20mA Proportional Phase Control Input
Ratings from 25A to 100 Amp @ 70-280 VAC
SCR output for heavy industrial loads
Instantaneous turn-on outputs
UL/CE/ROHS Compliant
Includes Plastic IP20 Terminal Cover
Direct bond copper substrate
Direct power lead frame
Epoxy free design
Specification
Crydom Part Number
HS151DR + D2475
Switching Type
Zero Crossing
ROHS/CE/UL
Yes
Control Voltage
4 - 32VDC
Load Current @ 40 Deg C
42 Amp
Surge Capability
910 Amp (peak)
Special Feature
N/A
Mounting Style
Din Rail Mount
Load Voltage Range
24-280VAC
Max Non Repetitive Peak Voltage
850 Vp
Termination Style
Screw
Dimensions
L:105mm x W:67.5mm x D:132mm
Unit Weight
1050g
Factory Pack Qty
20
Datasheets
HS151DR Datasheet
Series 1
Product Notifications
Please note Changes from Gen 3 to Gen 4 (current) package design here
FP025080P, 250/5 Amp Split Core CT, Class 1, 1.5VA Series Clip On Current Transformer
Features
Quick Release Split Core System
Built In Sealable Terminal Covers
Mounting Feet Supplied
Self Powered
Rated System Voltage 0.72/3kV
IEC185, BS 7626, BSEN 60044-1 and IEC 60044-1
Applications
Metering Equipment
Energy Monitoring
AC Power Control Systems
Power Factor Correction
Power Quality Measurements
Specification
Fastron Part Number
FP025080P
Technology
Split Core AC Clip On Current Transformer
Ratio
250/5
Aperture Size
50 x 80mm
VA Rating
1.5VA
Accuracy Class
Class 1
Output
5 Amp AC (+20%)
Isolation
3kV (AC, 50Hz, 1 min)
Bandwidth
50-60Hz
Mounting Style
Panel Mount/Busbar Mount
Operating Temperature Range
-10°C / 50°C
Continuous Current (max)
250Amp x 1.2
Termination Style
Screw
Approvals
CE
Unit Weight
1150g
Factory Pack Qty
1
Datasheet
Product Datasheet
Installation Guide
FP050125P, 500/5 Amp Split Core CT, Class 0.5 2.5VA Series Clip On Current Transformer
Features
Quick Release Split Core System
Built In Sealable Terminal Covers
Mounting Feet Supplied
Self Powered
Rated System Voltage 0.72/3kV
IEC185, BS 7626, BSEN 60044-1 and IEC 60044-1
Applications
Metering Equipment
Energy Monitoring
AC Power Control Systems
Power Factor Correction
Power Quality Measurements
Specification
Fastron Electronics Part Number
FP050125P
Technology
Split Core AC Clip On Current Transformer
Ratio
500/5
Aperture Size
85 x 120mm
VA Rating
2.5VA
Accuracy Class
Class 0.5
Output
5 Amp AC (+20%)
Isolation
3kV (AC, 50Hz, 1 min)
Bandwidth
50-60Hz
Mounting Style
Panel Mount/Busbar Mount
Operating Temperature Range
-10°C / 50°C
Continuous Current (max)
500Amp x 1.2
Termination Style
Screw
Approvals
CE
Unit Weight
1150g
Factory Pack Qty
1
Datasheet
Product Datasheet
Installation Guide
FP120125P, 1200/5 Amp Split Core CT, Class 0.5, 7.5VA Series Clip On Current Transformer
Features
Quick Release Split Core System
Built In Sealable Terminal Covers
Mounting Feet Supplied
Self Powered
Rated System Voltage 0.72/3kV
IEC185, BS 7626, BSEN 60044-1 and IEC 60044-1
Applications
Metering Equipment
Energy Monitoring
AC Power Control Systems
Power Factor Correction
Power Quality Measurements
Specification
Fastron Electronics Part Number
FP120125P
Technology
Split Core AC Clip On Current Transformer
Ratio
1200/5
Aperture Size
85 x 120mm
VA Rating
7.5VA
Accuracy Class
Class 0.5
Output
5 Amp AC (+20%)
Isolation
3kV (AC, 50Hz, 1 min)
Bandwidth
50-60Hz
Mounting Style
Panel Mount/Busbar Mount
Operating Temperature Range
-10°C / 50°C
Continuous Current (max)
1200Amp x 1.2
Termination Style
Screw
Approvals
CE
Unit Weight
1150g
Factory Pack Qty
1
Datasheet
Product Datasheet
Installation Guide