DC-0-100-010-1.0, Hall Effect DC Current Transducer, 0-100 Amp DC, 0-10V Bipolar output, 24VDC supply
DC-0-100-010-1.0, Hall Effect DC Current Transducer, 0-100 Amp DC, 0-10V Bipolar output, 24VDC supply Compact and versatile Split Core DC current sensor, 0-100 Amp DC, 4-20 mA Bipolar Output Other measurement ranges available on request Features ⌀20mm Aperture DC Bipolar Measurement 0-10V analogue output Busbar, or DIN Rail Mounting Isolated plastic case recognised according to UL94-V0 Advantages High isolation between primary and secondary circuits Easy installation DIN Rail Kit available Applications -Automation Systems Analogue current reading for remote monitoring (e.g. Motor) -Data Loggers Self Powered. Will not drain data logger batteries -Panel Meters Simple connection displays power consumption Specification Fastron Part Number DC-0-100-010-1.0 Technology DC Hall Current Sensor with Process Output ROHS Yes Supply Voltage 24VDC Nominal Current (DC) 0-100 Amp Response Time < 1uS Output Bipolar 0-10V Isolation 2.5kV (AC, 50Hz, 1 min) Bandwidth DC Mounting Style DIN Rail Mount Operating Temperature Range -40°C / 85°C Accuracy 1% Termination Style Elevator Terminals Unit Weight 120g Factory Pack Qty 6 Datasheet Product Datasheet
$385.00
$454.30 inclGST -
FP040030P, 400/5 Amp Split Core CT, Class 0.5 2.5VA Clip On AC Current Transformer, 20 x 30mm Aperture, Dimension 90 x 40 x 110mm
Free Aus Post Shipping for $300 spendFastron FP040030P, 400/5 Amp Split Core CT, Class 0.5 2.5VA AC Clip On Current Transformer, 20 x 30mm Aperture, Dimension 90 x 40 x 110mm Features Quick Release Split Core System Built In Sealable Terminal Covers Mounting Feet Supplied Self Powered Rated System Voltage 0.72/3kV IEC185, BS 7626, BSEN 60044-1 and IEC 60044-1 Applications Metering Equipment Energy Monitoring AC Power Control Systems Power Factor Correction Power Quality Measurements Specification Fastron Part Number FP040030P Technology Split Core AC Clip On Current Transformer Ratio 400/5 Aperture Size 20 x 30mm VA Rating 1.5VA Accuracy Class Class 1 Output 5 Amp AC (+20%) Isolation 3kV (AC, 50Hz, 1 min) Bandwidth 50-60Hz Mounting Style Panel Mount/Busbar Mount Operating Temperature Range -10°C / 50°C Continuous Current (max) 400Amp x 1.2 Termination Style Screw Approvals CE Unit Weight 1150g Factory Pack Qty 1 Datasheet Product Datasheet Installation Guide
-
FP010030P/1A, 100/1 Amp Split Core CT, Class 1, 1VA Clip On AC Current Transformer, 20 x 30mm Aperture, Dimension 90 x 40 x 110mm
FP010030P/1A, 100/1 Amp Split Core CT, Class 1, 1VA Clip On AC Current Transformer, 20 x 30mm Aperture, Dimension 90 x 40 x 110mm Features Quick Release Split Core System Built In Sealable Terminal Covers Mounting Feet Supplied Self Powered Rated System Voltage 0.72/3kV IEC185, BS 7626, BSEN 60044-1 and IEC 60044-1 Applications Metering Equipment Energy Monitoring AC Power Control Systems Power Factor Correction Power Quality Measurements Specification Fastron Part Number FP010030P/1A Technology Split Core AC Clip On Current Transformer Ratio 100/1 Aperture Size 20 x 30mm VA Rating 1VA Accuracy Class Class 1 Output 1 Amp AC (+20%) Isolation 3kV (AC, 50Hz, 1 min) Bandwidth 50-60Hz Mounting Style Panel Mount/Busbar Mount Operating Temperature Range -10°C / 50°C Continuous Current (max) 100Amp x 1.2 Termination Style Screw Approvals CE Unit Weight 1150g Factory Pack Qty 1 Datasheet Product Datasheet Installation Guide
$92.00
$108.56 inclGST -
LT 4000-S, C/L Hall Effect current transducer, Ipn = 4000 Amp, Isn = 800mA, +/-15VDC Supply
Free Aus Post Shipping for $300 SpendLEM LT 4000-S, C/L Hall Effect current transducer, Ipn = 4000 Amp, Isn = 800mA, +/-15VDC Supply Features Bipolar and insulated current measurement up tp 6000 Amp Current output Bandwidth DC to 100kHz Closed loop (compensated) current transducer Panel mounting Insulated plastic case recognized according to UL 94-V0 Advantages Very good linearity High accuracy Low offset drift over temperature Wide frequency bandwidth Very low insertion losses High immunity to external interference Current overload capability Low power consumption Applications Windmill Inverters Test and Measurement Substations AC variable speed drives and servo motor drives Static converters for DC motor drives Battery supplied applications Uninterruptible Power Supplies (UPS) Switched Mode Power Supplies (SMPS) Power supplies for welding applications Application Domain Industrial Standards EN 50178:1997 IEC61010-1:2010 UL 508:2010 Specification LEM Part Number LT 4000-S Technology Closed Loop Hall Effect Aperture 102mm ROHS Yes Supply Voltage +/- 15 VDC to +/- 24 VDC Bipolar, Isolated Load Current (RMS + DC) 4000 Amp Measurement Range +/- 6000 Amp Output 800 mA Isolation 6 kV Bandwidth DC-100 kHz Mounting Style Panel Mount Operating Temperature Range -10°C / 85°C Accuracy 0.5% Termination Style M5 threaded studs Unit Weight 12.1kg Factory Pack Quantity 1 Datasheet Product Datasheet Application Notes LEM Applications Manual 3rd Edition
-
ITC 2000-S/SP1 High Precision Hall Effect Current Sensor, 2000 Amp, 800mA Output, 63mm Aperture, +/-24V Supply
Free Aus Post Shipping for $300 SpendITC 2000-S/SP1 High Precision Hall Effect Current Sensor, 2000 Amp, 800mA Output, 63mm Aperture, +/-24V Supply Datasheet Product Datasheet
-
DH 800 B420L B, Current Transducer, 800Amp Bipolar, 4-20mA output, 24V loop powered
Free Aus Post Shipping for $300 SpendDH 800 B420L B Current Transducer, 800Amp Bipolar, 4-20mA output, 24V loop powered Product Datasheet , Obsolete - No replacement in single package. Contact us for a solution
-
LTC 600-S, C/L Hall Effect Current Sensor, 400 Amp, 100mA Output, +/-15..24V, Panel Mount, ø42mm, X = 0.7%
Free Aus Post Shipping for $300 SpendLEM LTC 600-S Open Loop AC/DC Hall Effect Sensor Features Bipolar and insulated current measurement up tp 1500 Amp Current output Bandwidth DC to 100kHz Closed loop (compensated) current transducer Panel mounting Insulated plastic case recognized according to UL 94-V0 Advantages Very good linearity High accuracy Low offset drift over temperature Wide frequency bandwidth Very low insertion losses High immunity to external interference Current overload capability Low power consumption Applications Railway Equipment Windmill Inverters Test and Measurement Substations AC variable speed drives and servo motor drives Static converters for DC motor drives Battery supplied applications Uninterruptible Power Supplies (UPS) Switched Mode Power Supplies (SMPS) Power supplies for welding applications Application Domain Industrial Traction Standards EN 50178:1997 IEC61010-1:2010 UL 508:2010 Specification LEM Part Number LTC 600-S Technology Closed Loop Hall Effect Aperture ø42mm ROHS Yes Supply Voltage +/- 15 VDC to +/- 24 VDC Bipolar, Isolated Load Current (RMS + DC) 600 Amp Measurement Range +/- 1500 Amp Output 100 mA Isolation 13.4 kV Bandwidth DC-100 kHz Mounting Style Busbar Mount Operating Temperature Range -10°C / 85°C Accuracy 0.7% Termination Style Faston 45° 6.3 x 0.8mm and M5 threaded studs Unit Weight 750g Factory Pack Quantity 6 Datasheet Product Datasheet Application Notes LEM Applications Manual 3rd Edition Accessories For Feet Kit or Busbar Kit see datasheet or LEM accessories for more details
-
Elite E500R-51E2, Panel Mount Network Recorder & 4000A/140mm Rogowski Coils, with Harmonics (15th), Class 0.5S, 50..500VAC 50/60Hz, RS485 Modbus RTU, 35..300V DC/85..300VAC Aux, 16MB Dual Logger , TFT Touch Screen, 10 Years Warranty
Secure Elite E500R-51E2, Panel Mount Network Recorder & 4000A/140mm Rogowski Coils, with Harmonics (15th), Class 0.5S, 50..500VAC 50/60Hz, RS485 Modbus RTU, 35..300V DC/85..300VAC Aux, 16MB Dual Logger , TFT Touch Screen, 10 Years Warranty Automatic range of nominal current up to 6 A (Includes 5A/1A CT Input) and nominal voltage up to 500 V L-L, 300V L-N Dual Loggers, configurable for Instant or accumulated energy RMS values of currents and voltages Measurements of active, reactive, apparent power and power factor Measurements of energy in all 4 quadrants Average values of measurands per interval RS 485 communication up to 38400 bit/s as standard Optional Protocol Modules Modbus TCP, BACNet IP, Profinet, SCADA EC61850 Optional Modules for Analogue outputs and Relay Alarms The meter is intended for measuring, analysing and monitoring single-phase or three-phase electrical power network. The meter records TRMS value according to the principle of fast sampling of voltage and current signals. A built-in microprocessor calculates measurands (voltage, current, frequency, energy, power, power factor, phase angles, etc.) from the measured signals. Features : Measurement of instantaneous values and accumulated energy. Includes Harmonics to the 15th Accuracy class 0.5S Dual Internal Loggers Measurement of 20 minimal and maximal values in different time periods RS 232/RS 485 communication up to 38400 bit/s MODBUS communication protocol Optional Protocol Modules Modbus TCP, BACNet IP, Profinet, SCADA EC61850 Configurable 2 x Tariff Inputs or 2 x Pulse Outputs, or Alarm Outputs Universal or AC/DC power supply Graphic Colour TFT 320 x 240 pixels (53x70mm) Automatic range of nominal current up to 6 A and nominal voltage up to 500 V Multilingual support User-friendly Free ECon Configuration software Specification Secure Part Number E500R-51E2 Functions Power Quality Meter, Energy Meter Rogowski Coil Rating/Size 4000A/140mm Supply Voltage Universal 35..300V DC, 85..300VAC Nominal Measurement Range 240V L-N, 100mV/kA @ 50 Hz, 415V L-L Maximum Measurement Range 300V L-N, 100mV/kA @ 50 Hz, 500V L-L Alarm Optional Module 2 Relay/Pulse Outputs Tariff/Digital Inputs TOU Tarriff Clock Accuracy Class 0.5S (I,U,F,PF,θ,THD) Class 1(Active), Class 2 (Reactive) Analogue Output Optional Module 2 x Programmable Analogue Outputs Internal Memory 2 x 8MB Battery Backup N/A Real Time Clock 1min/month (30ppm) Isolation 3.5kV RS232/RS485 N/A Optional CT Termination Ring Terminals Weight 600g Certification CE, CSA, ROHS Warranty 10 Years from dispatch from Secure Warehouse Factory Pack Qty 1 EU Directives Degree on electrical equipment designed for use within certain voltage limits URLRS 53/00 (Directive 73/23/EEC on low voltage): SIST EN 61010-1:2002 Safety Requirement for electrical equipment for measurement, control and laboratory use, part1 : general requirement Decree on electromagnetic Compatibility (EMC) URLRS 61/00 (Directive 89/336/EEC on electromagnetic compatibility): SIST EN 61036 item 4.5: 1998 Meters for active energy (class 1 and 2) Safety Protection Class II 600V rms, installation category II 300V rms, installation category III Pollution Degree 2 in compliance with SIST EN 61010-1:2002 Enclosure Material PC/ABS non combustable-self-extinguishability, complying with UL 94 V-0 Enclosure Protection IP52 (IP00 for terminals) in compliance with SIST EN 60529:1997 Resistance to HF Interference Immunity to radiated electrostatic fields IEC/EN 61000-4-3 Immunity to fast transients (burst immunity) IEC/EN 61000-4-4, level 3 Immunity to shock waves IEC/EN 61000-4-5 Radio frequency in common mode IEC/EN 61000-4-6, level 3 Voltage dips and breaks (AC) IEC/EN 61000-4-11 Immunity to damped oscillatory waves IEC/EN 61000-4-12 Conducted and radiated emissions Class B (*) in accordance with EN 55022, EN 55011 (CISPR22, CISPR11) group 1 (*) Except configuration (88 970 1.1 or 88 970 1.2) + (88 970 250 or 88 970 270) + 88 970 241 class A (class B in a metal enclosure) Operating Temperature -20 →+70 °C Datasheet Product Datasheet Cross Reference The Following meters are close equivalents to Elite 500 Series. For further details please contact Fastron Sales Team Elite 500_400_300_100 series competition replacement for Schneider Siemens Accuenergy (RS485 +DNP3 default) Socomec Selec PM 5000 series PAC 2000 series ACCUVIM-CL + DNP3.0 DIRIS A-20 Selec MFM376 PM 5100 PAC 3200 ACCUVIM-CL + DNP3.0 DIRIS A-20 MFM384, CL-1, RS485 PM 5300 ACCUVIM-IIR DIRIS A-20 MFM383A PM 5500 PAC 4200 ACCUVIM-IIR(+ BACnet) DIRIS A-20 MFM384. RS485 PM 6463 Siemens 7KMPAC4200 ACCUVIM-IIR (+ Profibus) DIRIS A-30/ DIRIS - A60 (PQ Feature) MFM384-C-CE-CL05, RS485 PM 5650 ACCUVIM-IIR (+ IEC 61850) DIRIS A-30 + Profibus MFM384-C-CE-CL05, RS485 PM 5760 ACCUVIM-EL DIRIS A-30 +Ethernet MFM384-C-CE-CL05, RS485 PM5330 ACCUVIM-EL (+ BACnet) DIRIS A-30/ DIRIS A-60 PM 5560 ACCUVIM-EL (+ Profibus) DIRIS A-30/ DIRIS A-60 DM6200H ACCUVIM-EL (+ IEC 61850) PM2220 ACCUVIM-II R +Ethernet PM2230 / DM2120 (LED) PM 5350
$1,437.00
$1,695.66 inclGST -
LTC 600/SP02A(LA600-T), C/L Hall Effect Current Sensor, 600 Amp, 100mA Output, +/-15..24V, Panel Mount, w/ busbar, X = 0.7%
Free Aus Post Shipping for $300 SpendLEM LTC 600/SP02A(LA600-T) Open Loop AC/DC Hall Effect Sensor Features To replace LA 600-T Bipolar and insulated current measurement up tp 1500 Amp Current output Bandwidth DC to 100kHz Closed loop (compensated) current transducer Panel mounting Insulated plastic case recognized according to UL 94-V0 with Busbar and Feet Kit(not shown) Advantages Very good linearity High accuracy Low offset drift over temperature Wide frequency bandwidth Very low insertion losses High immunity to external interference Current overload capability Low power consumption Applications Railway Equipment Windmill Inverters Test and Measurement Substations AC variable speed drives and servo motor drives Static converters for DC motor drives Battery supplied applications Uninterruptible Power Supplies (UPS) Switched Mode Power Supplies (SMPS) Power supplies for welding applications Application Domain Industrial Traction Standards EN 50178:1997 IEC61010-1:2010 UL 508:2010 Specification LEM Part Number LTC 600/SP02A(LA600-T) Technology Closed Loop Hall Effect Aperture No Aperture ROHS Yes Supply Voltage +/- 15 VDC to +/- 24 VDC Bipolar, Isolated Load Current (RMS + DC) 600 Amp Measurement Range +/- 1500 Amp Output 100 mA Isolation 13.4 kV Bandwidth DC-100 kHz Mounting Style Busbar Mount (with feet) Operating Temperature Range -10°C / 85°C Accuracy 0.7% Termination Style Faston 45° 6.3 x 0.8mm and M5 threaded studs Unit Weight 750g Factory Pack Quantity 6 Datasheet Product Datasheet Application Notes LEM Applications Manual 3rd Edition Accessories For Feet Kit or Busbar Kit see datasheet or LEM accessories for more details
-
FRS 1000-SUIH, O/L Coreless Current Transducer, 1000 Amp, +12V...24VDC Supply, 111.4 x 18.7 Square Aperture, 4-20mA Unipolar Output, Traction Version
LEM FRS 1000-SUIH, O/L Coreless Current Transducer, 1000 Amp, +12V...24VDC Supply, 111.4 x 18.7 Square Aperture, 4-20mA Unipolar Output, Traction Version Features Bandwidth DC to 1000kHz Open loop transducer using Coresless Hall effect Compact and versatile Panel mounting-Horizontal or Vertical Insulated plastic case recognized according to UL 94-V0 Advantages Very good linearity Very good accuracy Low temperature drift Wide frequency bandwidth Very low insertion losses Low power consumption Applications Wind Turbines Electrolyser AC variable speed drives and servo motor drives Static converters for DC motor drives Battery supplied applications Uninterruptible Power Supplies (UPS) Switched Mode Power Supplies (SMPS) Power supplies for welding applications. Specification LEM Part Number FRS 1000-SUIH Technology Open Loop Coreless Hall Effect Aperture 111.4 x 18.7mm Square ROHS Yes Supply Voltage +12...24VDC, Isolated Load Current (RMS + DC) 1000 Amp Measurement Range +/-3000 Amp Overload Rating N/A Output 4-20mA Unipolar Isolation 18.5 kV Bandwidth DC-1000 kHz Mounting Style Panel Mount/Busbar Mount Operating Temperature Range -25°C / 85°C Accuracy 1% Termination Style Molex 5045-04A Unit Weight 1500g Factory Pack Quantity 4 Datasheet Product Datasheet Application Notes LEM Applications Manual 3rd Edition
$529.00
$624.22 inclGST -
MC740 S SFUNC, Panel Mount Measuring Center 3 Phase, Class 0.5 50-500VAC L-L 50/60Hz Measurement, 240VAC Supply, USB Comms, w/ Supercap
Free Aus Post Shipping for $300 SpendIskra Doo MC740 S SFUNC, Panel Mount Measuring Center 3 Phase, Class 0.5 50-500VAC L-L 50/60Hz Measurement, 240VAC Supply, USB Comms, w/ Supercap Smart Meter Automatic range of nominal current up to 12.5 A (Includes 5A/1A CT Input) and nominal voltage up to 750 V L-N Adjustable tariff clock, display of electric energy consumption in optional currency Optional RS 232/RS 485 communication up to 115,200 bit/s or Ethernet communication Usage The meter is intended for measuring, analysing and monitoring single-phase or three-phase electrical power network. The meter records TRMS value according to the principle of fast sampling of voltage and current signals. A built-in microprocessor calculates measurands (voltage, current, frequency, energy, power, power factor, phase angles, etc.) from the measured signals. Features : Measurement of instantaneous values of more than 140 quantities (U, I, P, Q, S, PF, PA, f, f, MD, energy, energy price by tariffs, etc.). Accuracy class 0.5 or 0.2 (on demand) Measurement of 40 minimal and maximal values in different time periods 32 adjustable alarms Wide frequency range from 16 Hz to 400 Hz RS 232/RS 485 communication up to 115,200 bit/s or Ethernet communication MODBUS and DNP3 communication protocol MMC memory card for setting and upgrading the meter Up to 4 inputs or outputs (analogue outputs, pulse outputs, alarm outputs, tariff inputs) Universal or AC power supply Graphic LCD 128 x 64 dots with illumination Automatic range of nominal current up to 5 A and nominal voltage up to 750 V Adjustable tariff clock, display of electric energy consumption in optional currency Multilingual support User-friendly PC MiQen software 128 samples in one period Measurement of THD on Current or Voltage from 0 to 400% Specification Iskra Doo Part Number MC740 S SFUNC Functions Power Quality Meter, Energy Meter, Power Transducer, Network Analyser Supply Voltage 240VAC < 5VA 50/60Hz Nominal Measurement Range 50-500VAC L-L, 5 Amp Maximum Measurement Range 750V L-N, 12.5 Amp Alarm N/A (Optional 4 Relays, 32 Alarms, 4 Groups) Analogue Output N/A (Optional 4 x 20mA) Digital Input N/A (Optional 4 x 230VAC/DC,75..130VAC/DC..5..48VAC/DC) Pulse Output N/A (Optional) Pulse Input N/A (Optional) Bistable Switch/Latching Relay Alarm N/A (Optional) Status (Watchdog) Output N/A (Optional) Tariff Input N/A (Optional 4 x 230VAC/DC,75..130VAC/DC..5..48VAC/DC) Accuracy Class 0.5 (I,U,F,PF,θ,THD) (Class 0.2 Optional) Class 1(Active), Class 2 (Reactive) Battery Backup Supercap Real Time Clock 1min/month (30ppm) Internal Memory 8MB MMC up to 2GB Isolation 3.7kV Ethernet RJ45 10/100Mbit/s USB Yes (2400-115200 b/s) RS232/RS485 N/A (optional 2400-115200 b/s) Weight 600g Certification UL, CSA, ROHS Factory Pack Qty 1 EU Directives Degree on electrical equipment designed for use within certain voltage limits URLRS 53/00 (Directive 73/23/EEC on low voltage): SIST EN 61010-1:2002 Safety Requirement for electrical equipment for measurement, control and laboratory use, part1 : general requirement Decree on electromagnetic Compatibility (EMC) URLRS 61/00 (Directive 89/336/EEC on electromagnetic compatibility): SIST EN 61036 item 4.5: 1998 Meters for active energy (class 1 and 2) Safety Protection Class II 600V rms, installation category II 300V rms, installation category III Pollution Degree 2 in compliance with SIST EN 61010-1:2002 Enclosure Material PC/ABS non combustable-self-extinguishability, complying with UL 94 V-0 Enclosure Protection IP52 (IP00 for terminals) in compliance with SIST EN 60529:1997 Resistance to HF Interference Immunity to radiated electrostatic fields IEC/EN 61000-4-3 Immunity to fast transients (burst immunity) IEC/EN 61000-4-4, level 3 Immunity to shock waves IEC/EN 61000-4-5 Radio frequency in common mode IEC/EN 61000-4-6, level 3 Voltage dips and breaks (AC) IEC/EN 61000-4-11 Immunity to damped oscillatory waves IEC/EN 61000-4-12 Conducted and radiated emissions Class B (*) in accordance with EN 55022, EN 55011 (CISPR22, CISPR11) group 1 (*) Except configuration (88 970 1.1 or 88 970 1.2) + (88 970 250 or 88 970 270) + 88 970 241 class A (class B in a metal enclosure) Operating Temperature -20 →+70 °C except CB and XB versions in VDC : -30 →+70 °C (+40 °C in a non-ventilated enclosure) in accordance with IEC/EN 60068-2-1 and IEC/EN 60068-22 Datasheet Product Datasheet User Manual
-
LTC 350-TF C/L Hall Effect Current Sensor, 350 Amp, 175mA Output, +/-15..24V, Panel Mount, w/ busbar & feet, X = 0.3%
Free Aus Post Shipping for $300 SpendLEM LTC 350-TF Open Loop AC/DC Hall Effect Sensor Features Bipolar and insulated current measurement up tp 1200 Amp Current output Bandwidth DC to 100kHz Closed loop (compensated) current transducer Panel mounting Insulated plastic case recognized according to UL 94-V0 With Busbar and Feet Kit Advantages Very good linearity High accuracy Low offset drift over temperature Wide frequency bandwidth Very low insertion losses High immunity to external interference Current overload capability Low power consumption Applications Railway Equipment Windmill Inverters Test and Measurement Substations AC variable speed drives and servo motor drives Static converters for DC motor drives Battery supplied applications Uninterruptible Power Supplies (UPS) Switched Mode Power Supplies (SMPS) Power supplies for welding applications Application Domain Industrial Standards EN 50178:1997 IEC61010-1:2010 UL 508:2010 Specification LEM Part Number LTC 350-TF Technology Closed Loop Hall Effect Aperture No Aperture ROHS Yes Supply Voltage +/- 15 VDC to +/- 24 VDC Bipolar, Isolated Load Current (RMS + DC) 350 Amp Measurement Range +/- 1200 Amp Output 175 mA Isolation 12 kV Bandwidth DC-100 kHz Mounting Style Busbar Mount (with feet) Operating Temperature Range -10°C / 85°C Accuracy 0.5% Termination Style Faston 45° 6.3 x 0.8mm and M5 threaded studs Unit Weight 650g Factory Pack Quantity 6 Datasheet Product Datasheet Application Notes LEM Applications Manual 3rd Edition Accessories For Feet Fixing kit see Part # 93.34.43.100.0