Search results for "텔레@fundwash⟡:해외자금국내거래소fds뚫어주는곳"
-
3PH105-21(40) 160, Class 1 1.5VA 160 Amp, 5 Amp Output, 3 Phase Current Transformer, Panel Mount, Busbar Mount
Rishabh 3PH105-21(40) 160, Class 1 1.5VA 160 Amp, 5 Amp Output, 3 Phase Current Transformer, Panel Mount, Busbar Mount Features Built In Sealable Terminal Covers Mounting Feet Supplied Self Powered Rated System Voltage 0.72/3kV IEC185, BS 7626, BSEN 60044-1 and IEC 60044-1 Applications Metering Equipment Energy Monitoring AC Power Control Systems Power Factor Correction Power Quality Measurements Specification Rishabh Part Number 3PH105-21(40) 160 Technology AC Current Transformer Ratio 160/5 Aperture Size 20 x 24mm VA Rating 1.5VA Accuracy Class Class 1/Class 0.5 Output 5 Amp AC (+20%) Isolation 3kV (AC, 50Hz, 1 min) Bandwidth 50-60Hz Mounting Style Panel Mount/Din Rail Mount Operating Temperature Range -30°C / 85°C Continuous Current (max) 160Amp x 1.2 Termination Style Screw Unit Weight 1000g Factory Pack Qty 9 Datasheet Product Datasheet
$69.80
$82.36 inclGST -
3PH140-31(40) 300, Class 1 2.5VA 300 Amp, 5 Amp Output, 3 Phase Current Transformer, Panel Mount, Busbar Mount
Rishabh 3PH140-31(40) 300, Class 1 2.5VA 300 Amp, 5 Amp Output, 3 Phase Current Transformer, Panel Mount, Busbar Mount Features Built In Sealable Terminal Covers Mounting Feet Supplied Self Powered Rated System Voltage 0.72/3kV IEC185, BS 7626, BSEN 60044-1 and IEC 60044-1 Applications Metering Equipment Energy Monitoring AC Power Control Systems Power Factor Correction Power Quality Measurements Specification Rishabh Part Number 3PH105-31(40) 300 Technology AC Current Transformer Ratio 300/5 Aperture Size 30 x 36mm VA Rating 2.5VA Accuracy Class Class 0.5 / Class 1 Output 5 Amp AC (+20%) Isolation 3kV (AC, 50Hz, 1 min) Bandwidth 50-60Hz Mounting Style Panel Mount/Din Rail Mount Operating Temperature Range -30°C / 85°C Continuous Current (max) 300Amp x 1.2 Termination Style Screw Unit Weight 1500g Factory Pack Qty 9 Datasheet Product Datasheet
$78.20
$92.28 inclGST -
3PH140-31(40) 400, Class 1 2.5VA 400 Amp, 5 Amp Output, 3 Phase Current Transformer, Panel Mount, Busbar Mount
Rishabh 3PH140-31(40) 400, Class 1 2.5VA 400 Amp, 5 Amp Output, 3 Phase Current Transformer, Panel Mount, Busbar Mount Features Built In Sealable Terminal Covers Mounting Feet Supplied Self Powered Rated System Voltage 0.72/3kV IEC185, BS 7626, BSEN 60044-1 and IEC 60044-1 Applications Metering Equipment Energy Monitoring AC Power Control Systems Power Factor Correction Power Quality Measurements Specification Rishabh Part Number 3PH105-31(40) 400 Technology AC Current Transformer Ratio 400/5 Aperture Size 30 x 36mm VA Rating 2.5VA Accuracy Class Class 0.5 / Class 1 Output 5 Amp AC (+20%) Isolation 3kV (AC, 50Hz, 1 min) Bandwidth 50-60Hz Mounting Style Panel Mount/Din Rail Mount Operating Temperature Range -30°C / 85°C Continuous Current (max) 400Amp x 1.2 Termination Style Screw Unit Weight 1500g Factory Pack Qty 9 Datasheet Product Datasheet
$78.20
$92.28 inclGST -
3PH140-31(40) 500, Class 1 2.5VA 500 Amp, 5 Amp Output, 3 Phase Current Transformer, Panel Mount, Busbar Mount
Rishabh 3PH140-31(40) 500, Class 1 2.5VA 500 Amp, 5 Amp Output, 3 Phase Current Transformer, Panel Mount, Busbar Mount Features Built In Sealable Terminal Covers Mounting Feet Supplied Self Powered Rated System Voltage 0.72/3kV IEC185, BS 7626, BSEN 60044-1 and IEC 60044-1 Applications Metering Equipment Energy Monitoring AC Power Control Systems Power Factor Correction Power Quality Measurements Specification Rishabh Part Number 3PH105-31(40) 500 Technology AC Current Transformer Ratio 500/5 Aperture Size 30 x 36mm VA Rating 2.5VA Accuracy Class Class 1 / Class 2 Output 5 Amp AC (+20%) Isolation 3kV (AC, 50Hz, 1 min) Bandwidth 50-60Hz Mounting Style Panel Mount/Din Rail Mount Operating Temperature Range -30°C / 85°C Continuous Current (max) 500Amp x 1.2 Termination Style Screw Unit Weight 1500g Factory Pack Qty 9 Datasheet Product Datasheet
$78.20
$92.28 inclGST -
LM1360-MA4L-4-3-01-02-R-H-2, Panel Mount kWh Meter, Class 0.2S, 1/5Amp input, 2 Pulse Outputs, RS485 Comms, Three Section LCD Display
Risbabh LM1360-MA4L-4-3-01-02-R-H-2, Panel Mount kWh Meter, Class 0.2S, 1/5Amp input, 2 Pulse Outputs, RS485 Comms, Three Section LCD Display 2 Pulse Outputs Nominal current up to 1.2/6 A (For 1/5A CT Input) and nominal voltage up to 240V L-N Three Section Display RS 485 communication up to 19,200 bit/s RMS values of currents and voltages Measurements of active, reactive, apparent power and power factor THD up to 31sth Harmonic 85 Parameter Measurement The meter is intended for measuring, analysing and monitoring single-phase or three-phase electrical power network. The meter records TRMS value according to the principle of fast sampling of voltage and current signals. A built-in microprocessor calculates measurands (voltage, current, frequency, energy, power, power factor, phase angles, etc.) from the measured signals. Features : 96 x 96mm Panel Mount Accuracy class 0.2 Simple Menu RS 485 communication up to 19,200 bit/s MODBUS communication protocol 240V AC power supply Specification Rishabh Part Number LM1360-MA4L-4-3-01-02-R-H-2 Functions kWh Meter, Energy Meter Supply Voltage 240VAC < 5VA Nominal Measurement Range 600V L-L 350V L-N, 5 Amp Maximum Measurement Range 600V L-L 350V L-N, 6 Amp Display Three Line LCD Pulse Output 2 (input or output) Accuracy Class 0.2S (kW,kWh) Class 0.5(Active) Class 2(kVar,PF) Battery Backup N/A Real Time Clock 1min/month (30ppm) Isolation 3.5kV Ethernet Modbus RTU Over TCP/IP 2400-19200 b/s Weight 450g Certification EN 61010-1 Installation Category III Factory Pack Qty 1 Environment IP54 Safety Protection Class II Enclosure Material Mablex with fire protection to UL94-V-O. Self extinguishing EnclosureSize 96 x 96mm x 83.5mm (72mm behind panel) Terminals Rising Cage 4mm² (12 AWG) cable max Humidity < 75% Non Condensing Operating Temperature -20 →+70 °C Datasheet Product Datasheet Software Software User Manual Software Download Link Application Notes 1)Reading Data from Registers -> Download file 2)Maximum Memory Size -> Read below Max Available Memory Locations in 8MB Size = 273030 Actual parameter stored in Each log (Memory locations used) = Date +time+Number of parameter selected by user Considering your example for 2 parameters: Number of parameter selected by user = 2 (kwh & kVA) Actual parameter stored in Each log = 1(Date) +1(time)+ 2 (Parameters) = 4 (memory locations used per log) Maximum log that can be stored = Max Memory Location/Actual parameter stored in Each log =273030/4= 68257 Timelog Interval setting = 15 minutes Log in one day = (60 /Timelog Interval setting) * 24 =(60/15)*24 = 96 Logs Max Days = Maximum log that can be stored / log in one day = 68257 / 96 = 711 days = 1 Year & 11 Months = 23 Months.
$309.00
$364.62 inclGST -
DVC 1000-B, C/L Voltage Transducer, 1000V AC/DC Measurement, +/-15...24VDC Supply, Vsn= +/-6.66V, Panel Mount, or Din Rail Mount with Optional Clip
LEM DVC 1000-B, C/L Voltage Transducer, 1000V AC/DC Measurement, +/-15...24VDC Supply, Vsn= +/-6.66V, Panel Mount, or Din Rail Mount with Optional Clip Features Bandwidth DC to 47kHz Wago 2061 Connections +/-15...24VDC Bipolar Supply Closed loop transducer using Hall Effect Compact and versatile Panel Mount or Din Rail Mount with Optional Clip (93.30.R2.000.0) Insulated plastic case recognized according to UL 94-V0 Advantages Very good linearity High accuracy Low temperature drift Wide frequency bandwidth Very low insertion losses High immunity to external interference Voltage overload capability Low power consumption Applications AC variable speed drives and servo motor drives Single and Three Phase Inverters Static converters for DC motor drives Battery supplied applications Uninterruptible Power Supplies (UPS) Switched Mode Power Supplies (SMPS) Power supplies for welding applications Water Treatment Electronics Specification LEM Part Number DVC 1000-B Technology Closed Loop Hall Effect Aperture No Aperture ROHS Yes Supply Voltage +/-15...24VDC Primary Nominal Voltage +/-1000V AC/DC Measurement Range +/-1500V AC/DC Output +/-6.66 VDC Instantaneous (+/-10VDC over range) Isolation 4.2 kV Bandwidth DC-37 kHz Mounting Style Panel Mount or Din Rail Mount with Optional Clip (93.30.R2.000.0) Operating Temperature Range -40°C / 85°C Accuracy 1% Termination Style WAGO 2016 Connectors Unit Weight 57g Factory Pack Quantity 25 Datasheet Product Datasheet Application Notes LEM Applications Manual 3rd Edition
$297.00
$350.46 inclGST -
DVC 1000, C/L Voltage Transducer, 1000V AC/DC Measurement, +/-15..24VDC Supply, Isn= +/-20mA Instantaneous Output, Panel Mount, or Din Rail Mount with Optional Clip
LEM DVC 1000, C/L Voltage Transducer, 1000V AC/DC Measurement, +/-15..24VDC Supply, Isn= +/-20mA Instantaneous Output, Panel Mount, or Din Rail Mount with Optional Clip Features Bandwidth DC to 35kHz Wago 2061 Connections +/-15..24VDC Unipolar Supply Closed loop transducer using Hall Effect Compact and versatile Panel Mount or Din Rail Mount with Optional Clip (93.30.R2.000.0) Insulated plastic case recognized according to UL 94-V0 Advantages Very good linearity High accuracy Low temperature drift Wide frequency bandwidth Very low insertion losses High immunity to external interference Voltage overload capability Low power consumption Applications AC variable speed drives and servo motor drives Single and Three Phase Inverters Static converters for DC motor drives Battery supplied applications Uninterruptible Power Supplies (UPS) Switched Mode Power Supplies (SMPS) Power supplies for welding applications Water Treatment Electronics Specification LEM Part Number DVC 1000 Technology Closed Loop Hall Effect Aperture No Aperture ROHS Yes Supply Voltage +/-15..24VDC Primary Nominal Voltage +/-1000V AC/DC Measurement Range +/-1500V AC/DC Output +/-20mAInstantaneous (+/-30mA Over range) Isolation 4.2 kV Bandwidth DC-35 kHz Mounting Style Panel Mount or Din Rail Mount with Optional Clip (93.30.R2.000.0) Operating Temperature Range -40°C / 85°C Accuracy 1% Termination Style WAGO 2016 Connectors Unit Weight 57g Factory Pack Quantity 25 Datasheet Product Datasheet Application Notes LEM Applications Manual 3rd Edition
$240.40
$283.67 inclGST -
DVC 1000-UI, C/L DC Voltage Transducer, 1000V, +/-15..24VDC Supply, Unipolar 4-20mA Instantaneous Output, Panel Mount, or Din Rail Mount with Optional Clip
LEM DVC 1000-UI, C/L DC Voltage Transducer, 1000V, +/-15..24VDC Supply, Unipolar 4-20mA Instantaneous Output, Panel Mount, or Din Rail Mount with Optional Clip Features Bandwidth DC to 35kHz 8 Pins +/-15..24VDC Unipolar Supply 4-20mA Unipolar Output Closed loop transducer using Hall Effect Compact and versatile Panel Mount or Din Rail Mount with Optional Clip (93.30.R2.000.0) Insulated plastic case recognized according to UL 94-V0 Advantages Very good linearity High accuracy Low temperature drift Wide frequency bandwidth Very low insertion losses High immunity to external interference Voltage overload capability Low power consumption Applications AC variable speed drives and servo motor drives Single and Three Phase Inverters Static converters for DC motor drives Battery supplied applications Uninterruptible Power Supplies (UPS) Switched Mode Power Supplies (SMPS) Power supplies for welding applications Water Treatment Electronics Specification LEM Part Number DVC 1000-UI Technology Closed Loop Hall Effect Aperture No Aperture ROHS Yes Supply Voltage +/-15..24VDC Primary Nominal Voltage +/-1000V Measurement Range +/-1500V Output 4-20mA Unipolar Instantaneous (0.5mA underange/21mA overrange) Isolation 4.2 kV Bandwidth DC-35 kHz Mounting Style Panel Mount or Din Rail Mount with Optional Clip (93.30.R2.000.0) Operating Temperature Range -40°C / 85°C Accuracy 1% Termination Style Through Hole PCB Unit Weight 22g Factory Pack Quantity 25 Datasheet Product Datasheet Application Notes LEM Applications Manual 3rd Edition
$304.80
$359.66 inclGST -
FAT300D420, AC Current Transducer, 300Amp Measurement, 24mm Split Core, 4-20mA Average RMS Output, Accuracy = 1%, 500mm Flying Leads
Fastron Electronics FAT300D420, AC Current Transducer, 300Amp Measurement, 24mm Split Core, 4-20mA Average RMS Output, Accuracy = 1% Features Quick Release 24mm Split Core System Cale Mount 4-20mA Output 24VDc Aux Rated System Voltage 0.60/2.5kV 0.5M Flying Leads Applications US Based Metering Equipment Energy Monitoring AC Power Control Systems Power Factor Correction Power Quality Measurements Specification Fastron Part Number FAT300D420 Technology 24mm Split Core AC Current Transformer Ratio 300/4-20mA Aperture Size ø 24 mm VA Rating N/A Accuracy Class Class 1 Output 4-20mA (+20%) Isolation 2.5kV (AC, 50Hz, 1 min) Bandwidth 50-60Hz Mounting Style Cable Mount/Busbar Mount Operating Temperature Range -15°C / 45°C Continuous Current (max) 300Amp x 1.2 Termination Style 0.5M Flying leads Unit Weight 300g Factory Pack Qty 9 Datasheet Product Datasheet Application Notes Installation Guide
$189.00
$223.02 inclGST -
DS96/100A/75mV, Moving Coil Ammeter 100Amp for 100A/75mVDC Shunt Connect
Rishabh DS96/100A/75mVDC Direct Connect Moving Coil Ammeter Features Adjustable Display Scaling PC 94 UL V0 For robust Measurement Each unit needs just 72 x 72mm Panel Space 65mm Depth Specification Rishabh Part Number DS96/100A/75mV Nominal Measurement Range 0 - 100 Amp DC Shunt Input 0-75mV Unipolar Maximum Measurement Range 100 AmpDC Over Range Ipn x 2 Operating Temperature 0 - 50°C Frequency 15...100Hz Safety Rating IP52 case, IP20 terminals wiht back cover Termination Style Screw Mounting Style 72 x 72mm Panel Mount Case Material PC - UL 94 V0 Weight 320g Factory Pack Qty 1 Datasheet Product Datasheet
$69.50
$82.01 inclGST -
DS96/200A/75mV, Moving Coil Ammeter 200Amp DC for 200A/75mV Shunt Connect
Rishabh DS96/200A/75mV, Moving Coil Ammeter 200Amp DC for 200A/75mV Shunt Connect Features Adjustable Display Scaling PC 94 UL V0 For robust Measurement Each unit needs just 72 x 72mm Panel Space 65mm Depth Specification Rishabh Part Number DS96/200A/75mV Nominal Measurement Range 0 - 200 Amp AC Shunt Input 0-75mV Unipolar Maximum Measurement Range 200 Amp Over Range Ipn x 2 Operating Temperature 0 - 50°C Frequency 15...100Hz Safety Rating IP52 case, IP20 terminals wiht back cover Termination Style Screw Mounting Style 72 x 72mm Panel Mount Case Material PC - UL 94 V0 Weight 320g Factory Pack Qty 1 Datasheet Product Datasheet
$69.50
$82.01 inclGST -
4430.1693 TA45-A126F160E3, 2 Pole Rocker Switch, 16 AMP, 240VAC, 1 Pole Thermal Overload Protection, 230VAC Undervoltage Release, Quick Connection, Embossed Orange Transparent Illumination
Schurter, 4430.1693 TA45-A126F160E3, 2 Pole Rocker Switch, 16 AMP, 240VAC, 1 Pole Thermal Overload Protection, 230VAC Undervoltage Release, Quick Connection, Embossed Orange Transparent Illumination Thermal Circuit Breakers are used for over-current (overload and short-circuit) protection of electrical appliances, and as a disconnector in case of equipment failure/malfunction Description Rocker Switch Thermal circuit breaker 2-pole - Power tools Manual ON/OFF type Quick connect terminals 6.3 x 0.8 mm Features : < 3mS Trip Delay Time 1 Pole Disconnect 1kA Short Circuit Rating Suitable for 500VDC Isolation Applications: Power Tools Household Equipment Power Supplies and Chargers Industrial Appliances Standards : IEC 60934 2 x Ir: 5000 Cycles 500VDC Insulation Resistance 1.5kV (50Hz) Dielectric Strength Overload @ 6 x Ir Cos φ 0.6 IEC: min 40 trip @ 1.5 x Ir, cos φ 0.75 Allowable UL / CSA: min. 50 trips Specification Schurter Part Number 4430.1693 (TA45-A126F160E3) Functions 2 Pole Rocker Switch with 1 Pole Thermal Circuit Breaker Nominal Voltage 240VAC @ 50Hz or 28VDC (230VAC Undervoltage Release) Nominal Current Range 16 Amp RMS Trip Delay Time < 3ms Rated Frequency 50/60 Hz Operating Temperature -25 to 55 Deg C Insulation Resistance 500VDC Illumination Transparent Green Dielectric Strength 1.5kV (50Hz) Short Circuit Current 1kA Approvals UL, CSA Standards IEC 6094 Weight 100g Enclosure Material UL94 Factory Pack Qty 1 Datasheet Product Datasheet
$75.00
$88.50 inclGST