Fastron Electronics SCT-F16-175, 0.333V Output, 175Amp measurement Split Core Current Transformer, 16mm Aperture
Features
Quick Release Split Core System
Cable Mount
0.333V Output
Self Powered
Rated System Voltage 0.60/3kV
0.5M Flying Leads
Applications
US Based Metering Equipment
Energy Monitoring
AC Power Control Systems
Power Factor Correction
Power Quality Measurements
Specification
Fastron Part Number
SCT-F16-175
Technology
Split Core AC Current Transformer
Ratio
175/0.333V
Aperture Size
ø 15 mm
VA Rating
N/A
Accuracy Class
Class 1
Output
0.333V (+20%)
Isolation
3kV (AC, 50Hz, 1 min)
Bandwidth
50-60Hz
Mounting Style
Cable Mount/Busbar Mount
Operating Temperature Range
-15°C / 45°C
Continuous Current (max)
175Amp x 1.2
Termination Style
0.5M Flying leads
Unit Weight
100g
Factory Pack Qty
9
Datasheet
Product Datasheet
Application Notes
Installation Guide
Northern Design Multicube Modular TCP/IP Comms Module NEW WEB PAGE VERSION, with Internal logger
Requires Multicube Modular Master or Multicube Master with Logger
Up to 20 Meters in 1 with additional modules
Minimum 2 x 3 Phase Circuits with measurement module
Master Unit of Modular Multicube System
Optional master with logger
Optional 12 way pulse/alarm digital output modules
Nominal current up to 0.383V (For 0.333V CT Input) and nominal voltage up to 240V L-N 415V L-L
Graphic Display
Modbus RTU Ethernet communication up to 19,200 bit/s
True RMS measurement of currents and voltages
Â
The meter is intended for measuring, analysing and monitoring single-phase or three-phase electrical power network. The meter records TRMS value according to the principle of fast sampling of voltage and current signals. A built-in microprocessor calculates measurands (voltage, current, frequency, energy, power, reactive power, power factor, harmonics, etc.) from the measured signals. NEW WEB PAGE VERSION
Â
Features :
NEW WEB PAGE VERSION
20 Meters in same space as 4 traditional meters
20 x 3 Phase or 60 x Single Phase Circuits
Accuracy class 1
Simple Menu
MODBUS RTU RS485 communication up to 19,200 bit/s
5 Year Warranty
240V AC power supply
Specification
Northern Design Part Number
Multicube Modular Master
Functions
kWh Meter, Energy Meter, Power Quality
Supply Voltage
240VAC < 15VA
Nominal Measurement Range
415V L-L 240V L-N, 0.333V
Maximum Measurement Range
480V L-L 280V L-N, 0.383V
Display
Graphic LCD
Pulse Output
12 (Optional)
Accuracy
Class 1 (kW,kWh) Class 1(Active), Class 2 Reactive
Ethernet
2400-19200 b/s
Real Time Clock
1min/month (30ppm)
Isolation
2.11kV
RS232/RS485
Optional
Weight
175g
Certification
EN 61010-1 Installation Category III
Factory Pack Qty
1
Environment
Â
IP54
Â
Safety
Protection Class II
Enclosure Material
ABS with fire protection to UL94-V-O. Self extinguishing
EnclosureSize
164 x 96mm x 29mm
Â
Terminals
Rising Cage 4mm² (12 AWG) cable max
Humidity
< 75% Non Condensing
Operating Temperature
-20 →+70 °C
Â
Datasheet
Product brochure
User manual
Wiring Diagram
Suitable 0.333V CT's
Split Core CT's
GMTA-AV7-A-RN, AC Voltage Transducer with Alarm, 0-600VAC Input, 100-240VAC/DC Aux, 1 x Relay Alarm
Adjustable Zero and Span Setting
250mS Response Time
PC 94 UL V0
Input signals, Currents up to 10 Amp, and Voltages up to 600VAC or DC, can be converted to insulated 4 to 20 mA DC output (for direct current output type) or 0-10V/0-5V (For Direct Voltage Type), or given alarm Setpoint.
Each unit needs just 50mm x 120mm depth DIN Rail cabinet space
Specification
Part Number
GMTA-AV7-A-RN
Control Output
1 x SPST Alarms 3 Amp
Input
0-600VAC
Alarm Type
1 x SPST NO Relay 3 Amp
Over Range
x 1.2
Operating Temperature
0 - 60°C
Load Voltage
100-240VAC/DC
Span Adjustment Range
+/-10%
Zero Adjustment Range
+/-5%
Termination Style
Screw
Mounting Style
DIN Rail Mount
Case Material
PC - UL 94 V0
Weight
170g
Factory Pack Qty
1
Â
Datasheet
Product Datasheet
GMTA-DV6-A-RN, DC Voltage Transducer with Alarm, 0-300VDC Input, 100-240VAC/DC Aux, 1 x Relay Alarm
Adjustable Zero and Span Setting
250mS Response Time
PC 94 UL V0
Input signals, Currents up to 10 Amp, and Voltages up to 600VAC or DC, can be converted to insulated 4 to 20 mA DC output (for direct current output type) or 0-10V/0-5V (For Direct Voltage Type), or given alarm Setpoint.
Each unit needs just 50mm x 120mm depth DIN Rail cabinet space
Specification
Part Number
GMTA-DV6-A-RN
Control Output
1 x SPST Alarms 3 Amp
Input
0-300VDC
Alarm Type
1 x SPST NO Relay 3 Amp
Over Range
x 1.2
Operating Temperature
0 - 60°C
Load Voltage
100-240VAC/DC
Span Adjustment Range
+/-10%
Zero Adjustment Range
+/-5%
Termination Style
Screw
Mounting Style
DIN Rail Mount
Case Material
PC - UL 94 V0
Weight
170g
Factory Pack Qty
1
Â
Datasheet
Product Datasheet
GMTA-AV7-D-RN, AC Voltage Transducer with Alarm, 0-600VAC Input, 22-60VAC/DC Aux, 1 x Relay Alarm
Adjustable Zero and Span Setting
250mS Response Time
PC 94 UL V0
Input signals, Currents up to 10 Amp, and Voltages up to 600VAC or DC, can be converted to insulated 4 to 20 mA DC output (for direct current output type) or 0-10V/0-5V (For Direct Voltage Type), or given alarm Setpoint.
Each unit needs just 50mm x 120mm depth DIN Rail cabinet space
Specification
Part Number
GMTA-AV7-D-RN
Control Output
1 x SPST Alarms 3 Amp
Input
0-600VAC
Alarm Type
1 x SPST NO Relay 3 Amp
Over Range
x 1.2
Operating Temperature
0 - 60°C
Load Voltage
22-60VAC/DC
Span Adjustment Range
+/-10%
Zero Adjustment Range
+/-5%
Termination Style
Screw
Mounting Style
DIN Rail Mount
Case Material
PC - UL 94 V0
Weight
170g
Factory Pack Qty
1
Â
Datasheet
Product Datasheet
LEM LF 1010-S, C/L Hall Effect Sensor, 1000 Amp, +/-200mA Output, 40.5mm Aperture, +/-15..24V Supply, Panel Mount
Features
Bipolar and insulated current measurement up tp 2700 Amp
Current output
Bandwidth DC to 100kHz
Closed loop (compensated) current transducer
Panel mounting
Insulated plastic case recognized according to UL 94-V0
Advantages
Very good linearity
High accuracy
Low offset drift over temperature
Wide frequency bandwidth
Very low insertion losses
High immunity to external interference
Current overload capability
Low power consumption
Applications
Windmill Inverters
Test and Measurement
Substations
AC variable speed drives and servo motor drives
Static converters for DC motor drives
Battery supplied applications
Uninterruptible Power Supplies (UPS)
Switched Mode Power Supplies (SMPS)
Power supplies for welding applications
Application Domain
Industrial
Standards
EN 50178:1997
IEC61010-1:2010
UL 508:2010
Specification
LEM Part Number
LF 1010-S
Technology
Closed Loop Hall Effect
Aperture
ø40.5mm
ROHS
Yes
Supply Voltage
+/- 15 VDC to +/- 24 VDC Bipolar, Isolated
Load Current (RMS + DC)
1000 Amp
Measurement Range
+/- 2700 Amp
Output
200 mA
Isolation
3.8 kV
Bandwidth
DC-200 kHz
Mounting Style
Panel Mount
Operating Temperature Range
-10°C / 85°C
Accuracy
0.2%
Termination Style
Molex 6410
Unit Weight
503g
Factory Pack Quantity
9
Â
Datasheet
Product Datasheet
Application Notes
LEM Applications Manual 3rd Edition
Â
Fastron Electronics SCT-F24-150 Amp, 5 Amp Class 1 Series Current Transformer
Features
Quick Release Split Core System
Cable Mount
5 Amp Output
Self Powered
Rated System Voltage 0.60/3kV
0.9M Flying Leads
Applications
US Based Metering Equipment
Energy Monitoring
AC Power Control Systems
Power Factor Correction
Power Quality Measurements
Â
Specification
Fastron Part Number
SCT-F24-150-5A
Technology
Split Core AC Current Transformer
Ratio
150/5 Amp
Aperture Size
ø 24 mm
VA Rating
N/A
Accuracy Class
Class 1
Output
5 Amp (+20%)
Isolation
3kV (AC, 50Hz, 1 min)
Bandwidth
50-60Hz
Mounting Style
Cable Mount/Busbar Mount
Operating Temperature Range
-15°C / 45°C
Continuous Current (max)
150Amp x 1.2
Termination Style
0.9M Flying leads
Unit Weight
100g
Factory Pack Qty
9
Â
Datasheet
Product Datasheet
Application Notes
Installation Guide
LEM AHR 500 B420, Hall Effect Current Transducer, 500A, 4-20mA True RMS output, 20-50VDC supply
Compact and versatile transducers for high AC and DC currents from 500 to 2000A True RMS with signal conditioning. Choice of output types: 4-20 mA, 0-5 V or 0-10 V, Bandwidth: DC 20..6000 Hz
Features
Split Core
VFD and SCR waveforms current measurement
True RMS output
4-20mA current output
Busbar mounting
Eliminates insertion loss
Isolated plastic case recognised according to UL94-V0
Advantages
Large aperture for cable or busbar up to 104 x 40mm
High isolation between primary and secondary circuits
Easy installation
Applications
-AC Power Supplies or Motors
True RMS sensing - the most accurate way to monitor power supply or input power
-VFD Controlled Loads
VFD output indicates how the motor and attached load are operating
-SCR Controlled Loads
Accurate measurement of phase angle fired or burst fired(time proportional) SCR's and switch mode rectifiers. Current measurement gives faster response than temperature measurement.
-Renewable Energy Installations or Backup Batteries
Continuous condition monitoring allowing automatic failure detection and prediction
-Application Domain
Energy and Automation
Specification
LEM Part Number
AHR 1500 B420
Technology
Open Loop Hall Effect
ROHS
Yes
Supply Voltage
20 - 50V
Nominal Current (RMS + DC)
500 Amp
Maximum Measurement Current (Peak)
2000 Amp
Output
4-20mA
Isolation
5.8kV (AC, 50Hz, 1 min)
Bandwidth
20-6000Hz
Mounting Style
Panel Mount
Operating Temperature Range
-40°C / 70°C
Accuracy
1%
Termination Style
SFKC 2.5/4-ST-5.08-RF(Phoenix Contact)
Unit Weight
650g
Factory Pack Qty
6
Â
Datasheet
Product Datasheet
Application Notes
LEM Applications Manual 3rd Edition
Fastron Electronics FESCT-3000-1500, 1500Amp 100mV Class 1 Measurement Split Core CT's, 1M Flying Leads, 76x127mm Aperture
Features
Quick Release Split Core System
1m Flying Leads
Mounting Feet Supplied
Self Powered
Rated System Voltage 0.60/3kV
Applications
US Based Metering Equipment
Energy Monitoring
AC Power Control Systems
Power Factor Correction
Power Quality Measurements
Â
Specification
Fastron Electronics Part Number
FESCT-3000-1500
Technology
Split Core AC Current Transformer
Ratio
1500/100mV
Aperture Size
76x127mm
VA Rating
N/A
Accuracy Class
Class 1
Output
100mVAC (+20%)
Isolation
3kV (AC, 50Hz, 1 min)
Bandwidth
50-60Hz
Mounting Style
Cable Mount/Busbar Mount
Operating Temperature Range
-15°C / 55°C
Continuous Current (max)
1500Amp x 1.2
Termination Style
Terminals
Unit Weight
3000g
Factory Pack Qty
9
Â
Datasheet
Product Datasheet
Installation Guide
FESCTHY Install Guide
Fastron Electronics FESCT-3000-1000, 1000Amp 100mV Class 1 Measurement Split Core CT's, 1M Flying Leads, 76x127mm Aperture
Features
Quick Release Split Core System
1m Flying Leads
Mounting Feet Supplied
Self Powered
Rated System Voltage 0.60/3kV
Applications
US Based Metering Equipment
Energy Monitoring
AC Power Control Systems
Power Factor Correction
Power Quality Measurements
Â
Specification
Fastron Electronics Part Number
FESCT-3000-1000
Technology
Split Core AC Current Transformer
Ratio
1000/100mV
Aperture Size
76x127mm
VA Rating
N/A
Accuracy Class
Class 1
Output
100mVAC (+20%)
Isolation
3kV (AC, 50Hz, 1 min)
Bandwidth
50-60Hz
Mounting Style
Cable Mount/Busbar Mount
Operating Temperature Range
-15°C / 55°C
Continuous Current (max)
1000Amp x 1.2
Termination Style
Terminals
Unit Weight
3000g
Factory Pack Qty
9
Â
Datasheet
Product Datasheet
Installation Guide
FESCTHY Install Guide
Fastron Electronics FAT200D420T, AC Current Transducer, 200Amp Measurement, 36mm Split Core, 4-20mA Average RMS Output, Accuracy = 1%, Terminal Version
Features
Quick Release 36mm Split Core System
Cale Mount
4-20mA Output
24VDc Aux
Rated System Voltage 0.60/2.5kV
0.5M Flying Leads
Applications
Control Systems
Energy Monitoring
AC Power Control Systems
Power Factor Correction
Power Quality Measurements
Â
Specification
Fastron Part Number
FAT200D420T
Technology
36mm Split Core AC Current Transformer
Ratio
200/4-20mA
Aperture Size
ø 24 mm
VA Rating
N/A
Accuracy Class
Class 1
Output
4-20mA (+20%)
Isolation
2.5kV (AC, 50Hz, 1 min)
Bandwidth
50-60Hz
Mounting Style
Cable Mount/Busbar Mount
Operating Temperature Range
-15°C / 45°C
Continuous Current (max)
200Amp x 1.2
Termination Style
Screw Terminals
Unit Weight
250g
Factory Pack Qty
9
Â
Datasheet
Product Datasheet
Application Notes
Installation Guide