Eastron Europe DCM230 1-1-1-1 V2, DIN Rail Mount DC kWh Meter, 1000VDC, 85-265VAC aux, Class 1, 45/60/75mV Shunt Connect, w/ 1 x pulse outputs and RS485 Modbus RTU Comms, Single Tariff, MID Approved
45/60/75mV Shunt Connect
RS 485 communication up to 38,400 bit/s as standard
1 x Pulse Outputs (1 Configurable)
Bidirectional Measurement
The meter is intended for measuring, and monitoring single-phase or electrical power network. The meter records DC Current and Voltage (DC Power) value according to the principle of fast sampling of voltage and current signals. A built-in microprocessor calculates measurands (voltage, current, energy, power) from the measured signals.
Features :
Accuracy class 1
Measurement of Active and Reactive Power
Modbus RTU communication up to 38,400 bit/s communication
Pulse output as standard
Graphic LCD with illumination
Specification
Eastron Europe Part Number
DCM230 1-1-1-1 V2
Functions
DC Energy Meter
Supply Voltage
85-265VAC
Nominal Measurement Range
5-300VDC,5-600VDC,5-1000VDC (See version 1
Maximum Measurement Range
5-1000VDC
Nominal Current Input
Shunt up to 2000Amp See our DC Current Shunt Section for Suitable Shunt
Pulse Output
1 x Configurable 60/100/200ms
Tariff Input
N/A
Accuracy
Class 1 (I,U,kW,kWh)
Mounting
Din Rail
Real Time Clock
1min/month (30ppm)
Internal Memory
N/A
Dimensions
36mm x 100mm x 66mm (2 modules wide)
Isolation
4kV
RS485
2400-38400 b/s
Weight
250g
Certification
EN 61010-1 Installation Category III
Factory Pack Qty
1
Safety
IP51(Indoor)
Enclosure Material
Noryl with fire protection to UL94-V-O. Self extinguishing
Enclosure Size
DIN 42880 4 Modules
Operating Temperature
-20 →+70 °C
Documents
Product Datasheet
User Manual
Modbus Utility
EEM Meter Setting Software Utility
Risbabh LM1360-MA4L-4-3-01-02-R-H-2, Panel Mount kWh Meter, Class 0.2S, 1/5Amp input, 2 Pulse Outputs, RS485 Comms, Three Section LCD Display
2 Pulse Outputs
Nominal current up to 1.2/6 A (For 1/5A CT Input) and nominal voltage up to 240V L-N
Three Section Display
RS 485 communication up to 19,200 bit/s
RMS values of currents and voltages
Measurements of active, reactive, apparent power and power factor
THD up to 31sth Harmonic
85 Parameter Measurement
The meter is intended for measuring, analysing and monitoring single-phase or three-phase electrical power network. The meter records TRMS value according to the principle of fast sampling of voltage and current signals. A built-in microprocessor calculates measurands (voltage, current, frequency, energy, power, power factor, phase angles, etc.) from the measured signals.
Features :
96 x 96mm Panel Mount
Accuracy class 0.2
Simple Menu
RS 485 communication up to 19,200 bit/s
MODBUS communication protocol
240V AC power supply
Specification
Rishabh Part Number
LM1360-MA4L-4-3-01-02-R-H-2
Functions
kWh Meter, Energy Meter
Supply Voltage
240VAC < 5VA
Nominal Measurement Range
600V L-L 350V L-N, 5 Amp
Maximum Measurement Range
600V L-L 350V L-N, 6 Amp
Display
Three Line LCD
Pulse Output
2 (input or output)
Accuracy
Class 0.2S (kW,kWh) Class 0.5(Active) Class 2(kVar,PF)
Battery Backup
N/A
Real Time Clock
1min/month (30ppm)
Isolation
3.5kV
Ethernet
Modbus RTU Over TCP/IP 2400-19200 b/s
Weight
450g
Certification
EN 61010-1 Installation Category III
Factory Pack Qty
1
Environment
IP54
Safety
Protection Class II
Enclosure Material
Mablex with fire protection to UL94-V-O. Self extinguishing
EnclosureSize
96 x 96mm x 83.5mm (72mm behind panel)
Terminals
Rising Cage 4mm² (12 AWG) cable max
Humidity
< 75% Non Condensing
Operating Temperature
-20 →+70 °C
Datasheet
Product Datasheet
Software
Software User Manual
Software Download Link
Application Notes
1)Reading Data from Registers -> Download file
2)Maximum Memory Size -> Read below
Max Available Memory Locations in 8MB Size = 273030
Actual parameter stored in Each log (Memory locations used) = Date +time+Number of parameter selected by user
Considering your example for 2 parameters:
Number of parameter selected by user = 2 (kwh & kVA)
Actual parameter stored in Each log = 1(Date) +1(time)+ 2 (Parameters) = 4 (memory locations used per log)
Maximum log that can be stored = Max Memory Location/Actual parameter stored in Each log =273030/4= 68257
Timelog Interval setting = 15 minutes
Log in one day = (60 /Timelog Interval setting) * 24 =(60/15)*24 = 96 Logs
Max Days = Maximum log that can be stored / log in one day = 68257 / 96 = 711 days = 1 Year & 11 Months = 23 Months.
LEM DVC 1000-B, C/L Voltage Transducer, 1000V AC/DC Measurement, +/-15...24VDC Supply, Vsn= +/-6.66V, Panel Mount, or Din Rail Mount with Optional Clip
Features
Bandwidth DC to 47kHz
Wago 2061 Connections
+/-15...24VDC Bipolar Supply
Closed loop transducer using Hall Effect
Compact and versatile
Panel Mount or Din Rail Mount with Optional Clip (93.30.R2.000.0)
Insulated plastic case recognized according to UL 94-V0
Advantages
Very good linearity
High accuracy
Low temperature drift
Wide frequency bandwidth
Very low insertion losses
High immunity to external interference
Voltage overload capability
Low power consumption
Applications
AC variable speed drives and servo motor drives
Single and Three Phase Inverters
Static converters for DC motor drives
Battery supplied applications
Uninterruptible Power Supplies (UPS)
Switched Mode Power Supplies (SMPS)
Power supplies for welding applications
Water Treatment Electronics
Specification
LEM Part Number
DVC 1000-B
Technology
Closed Loop Hall Effect
Aperture
No Aperture
ROHS
Yes
Supply Voltage
+/-15...24VDC
Primary Nominal Voltage
+/-1000V AC/DC
Measurement Range
+/-1500V AC/DC
Output
+/-6.66 VDC Instantaneous (+/-10VDC over range)
Isolation
4.2 kV
Bandwidth
DC-37 kHz
Mounting Style
Panel Mount or Din Rail Mount with Optional Clip (93.30.R2.000.0)
Operating Temperature Range
-40°C / 85°C
Accuracy
1%
Termination Style
WAGO 2016 Connectors
Unit Weight
57g
Factory Pack Quantity
25
Datasheet
Product Datasheet
Application Notes
LEM Applications Manual 3rd Edition
LEM DVC 50, C/L Voltage Transducer, 50V AC/DC Measurement, +/-15..24VDC Supply, Vsn= +/-20mA Instantaneous Output, Panel Mount, or Din Rail Mount with Optional Clip
Features
Bandwidth DC to 35kHz
Wago 2061 Connections
+/-15...24VDC Unipolar Supply
Closed loop transducer using Hall Effect
Compact and versatile
Panel Mount or Din Rail Mount with Optional Clip (93.30.R2.000.0)
Insulated plastic case recognized according to UL 94-V0
Advantages
Very good linearity
High accuracy
Low temperature drift
Wide frequency bandwidth
Very low insertion losses
High immunity to external interference
Voltage overload capability
Low power consumption
Applications
AC variable speed drives and servo motor drives
Single and Three Phase Inverters
Static converters for DC motor drives
Battery supplied applications
Uninterruptible Power Supplies (UPS)
Switched Mode Power Supplies (SMPS)
Power supplies for welding applications
Water Treatment Electronics
Specification
LEM Part Number
DVC 50
Technology
Closed Loop Hall Effect
Aperture
No Aperture
ROHS
Yes
Supply Voltage
+/-15..24VDC
Primary Nominal Voltage
+/-50V AC/DC
Measurement Range
+/-75V AC/DC
Output
+/-20mA (+/-30mA Over range) Instantaneous
Isolation
4.2 kV
Bandwidth
DC-35 kHz
Mounting Style
Panel Mount or Din Rail Mount with Optional Clip (93.30.R2.000.0)
Operating Temperature Range
-40°C / 85°C
Accuracy
1%
Termination Style
WAGO 2016 Connectors
Unit Weight
57g
Factory Pack Quantity
25
Datasheet
Product Datasheet
Application Notes
LEM Applications Manual 3rd Edition
Fastron Electronics FAT300D420, AC Current Transducer, 300Amp Measurement, 24mm Split Core, 4-20mA Average RMS Output, Accuracy = 1%
Features
Quick Release 24mm Split Core System
Cale Mount
4-20mA Output
24VDc Aux
Rated System Voltage 0.60/2.5kV
0.5M Flying Leads
Applications
US Based Metering Equipment
Energy Monitoring
AC Power Control Systems
Power Factor Correction
Power Quality Measurements
Specification
Fastron Part Number
FAT300D420
Technology
24mm Split Core AC Current Transformer
Ratio
300/4-20mA
Aperture Size
ø 24 mm
VA Rating
N/A
Accuracy Class
Class 1
Output
4-20mA (+20%)
Isolation
2.5kV (AC, 50Hz, 1 min)
Bandwidth
50-60Hz
Mounting Style
Cable Mount/Busbar Mount
Operating Temperature Range
-15°C / 45°C
Continuous Current (max)
300Amp x 1.2
Termination Style
0.5M Flying leads
Unit Weight
300g
Factory Pack Qty
9
Datasheet
Product Datasheet
Application Notes
Installation Guide
Rishabh DS96/100A/75mVDC Direct Connect Moving Coil Ammeter
Features
Adjustable Display Scaling
PC 94 UL V0
For robust Measurement
Each unit needs just 72 x 72mm Panel Space
65mm Depth
Specification
Rishabh Part Number
DS96/100A/75mV
Nominal Measurement Range
0 - 100 Amp DC
Shunt Input
0-75mV Unipolar
Maximum Measurement Range
100 AmpDC
Over Range
Ipn x 2
Operating Temperature
0 - 50°C
Frequency
15...100Hz
Safety Rating
IP52 case, IP20 terminals wiht back cover
Termination Style
Screw
Mounting Style
72 x 72mm Panel Mount
Case Material
PC - UL 94 V0
Weight
320g
Factory Pack Qty
1
Datasheet
Product Datasheet
Rishabh DS96/400A/75mV DC Direct Connect Moving Coil Ammeter
Features
Adjustable Display Scaling
PC 94 UL V0
For robust Measurement
Each unit needs just 72 x 72mm Panel Space
65mm Depth
Specification
Rishabh Part Number
DS96/400A/75mV
Nominal Measurement Range
0 - 400 Amp AC
Shunt Input
0-75mV Unipolar
Maximum Measurement Range
400 Amp
Over Range
Ipn x 2
Operating Temperature
0 - 50°C
Frequency
15...100Hz
Safety Rating
IP52 case, IP20 terminals wiht back cover
Termination Style
Screw
Mounting Style
72 x 72mm Panel Mount
Case Material
PC - UL 94 V0
Weight
320g
Factory Pack Qty
1
Datasheet
Product Datasheet
Rishabh DS72/500A/75mV, Moving Coil Ammeter 500Amp DC for 500A/75mV Shunt Connect
Features
Adjustable Display Scaling
PC 94 UL V0
For robust Measurement
Each unit needs just 72 x 72mm Panel Space
65mm Depth
Specification
Rishabh Part Number
DS72/500A/75mV
Nominal Measurement Range
0 - 500 Amp AC
Shunt Input
0-75mV Unipolar
Maximum Measurement Range
500 Amp
Over Range
Ipn x 2
Operating Temperature
0 - 50°C
Frequency
15...100Hz
Safety Rating
IP52 case, IP20 terminals with back cover
Termination Style
Screw
Mounting Style
72 x 72mm Panel Mount
Case Material
PC - UL 94 V0
Weight
320g
Factory Pack Qty
1
Datasheet
Product Datasheet
Schurter, 4430.1693 TA45-A126F160E3, 2 Pole Rocker Switch, 16 AMP, 240VAC, 1 Pole Thermal Overload Protection, 230VAC Undervoltage Release, Quick Connection, Embossed Orange Transparent Illumination
Thermal Circuit Breakers are used for over-current (overload and short-circuit) protection of electrical appliances, and as a disconnector in case of equipment failure/malfunction
Description
Rocker Switch
Thermal circuit breaker
2-pole - Power tools
Manual ON/OFF type
Quick connect terminals 6.3 x 0.8 mm
Features :
< 3mS Trip Delay Time
1 Pole Disconnect
1kA Short Circuit Rating
Suitable for 500VDC Isolation
Applications:
Power Tools
Household Equipment
Power Supplies and Chargers
Industrial Appliances
Standards :
IEC 60934
2 x Ir: 5000 Cycles
500VDC Insulation Resistance
1.5kV (50Hz) Dielectric Strength
Overload @ 6 x Ir Cos φ 0.6 IEC: min 40 trip
@ 1.5 x Ir, cos φ 0.75 Allowable UL / CSA: min. 50 trips
Specification
Schurter Part Number
4430.1693 (TA45-A126F160E3)
Functions
2 Pole Rocker Switch with 1 Pole Thermal Circuit Breaker
Nominal Voltage
240VAC @ 50Hz or 28VDC (230VAC Undervoltage Release)
Nominal Current Range
16 Amp RMS
Trip Delay Time
< 3ms
Rated Frequency
50/60 Hz
Operating Temperature
-25 to 55 Deg C
Insulation Resistance
500VDC
Illumination
Transparent Green
Dielectric Strength
1.5kV (50Hz)
Short Circuit Current
1kA
Approvals
UL, CSA
Standards
IEC 6094
Weight
100g
Enclosure Material
UL94
Factory Pack Qty
1
Datasheet
Product Datasheet
MS Power MSD300R16MB, Rectifier Diode 300 Amp, 1600V, ⌀41 x 6.5 x ⌀33mm Flat Base, Anode Base, Replaces S6HR300
Features
Full blocking capability over wide temperature range
Hermetic metal case with glass insulator
Threaded stud
Applications
Power Supplies
Uncontrolled Rectifiers
Oil Cooled Circuits
Battery Chargers
Specification
MS Power Part Number
MSD300R16MB
Vrrm
1600V
Diode Configuration
Anode Stud
IF(av) @ 100 Deg C
390 Amp
IF(av) @ 125 Deg C
300 Amp
Itsm
5.6 kA
VF(to)
0.75V
Tj(max)
180°C
rF
0.40mΩ
Termination Style (Tail)
10mm Round Lug
Termination Style (Stud)
Flat Base ⌀41 x 6.5 x ⌀33mm
Tail Length to Base
177mm
R th(j-c)
0.16°C/W
R th(c-h)
0.005°C/W
Weight
250g
Mounting Torque
18 Nm
Factory Pack Qty
5
Country Of Origin
China
MS Power Headquarters
Germany
Datasheet
Product Datasheet
LEM HTRS 10-SBI, Railway Split Core DC Current Sensor, 10 Amp, 4-20mA Output
Features
Closed loop sensor using Hall Effect
Din Rail or Panel Mounting
Split core design for easy installation
Insulated plastic case to UL 94-V0 Water resistant design rated to IP 67
Reverse polarity protected
Advantages
Very good linearity
Excellent accuracy
Current overload capability
No insertion losses.
Non - contact measurement (does not need a safety case)
Applications
Railway equipment
Points condition monitoring
Signal light indication
Battery supplied applications Uninterruptable Power Supplies (UPS).
Specification
LEM Part Number
HTRS 10-SBI
Technology
Closed Loop Hall Effect
ROHS
Yes
Supply Voltage
24V
Aperture
ø10mm
Load Current (RMS + DC)
10 Amp
Measuring Range
+/- 20 Amp
Overload Capacity (Ampere Turns)
30000 Amp
Output
4-20mA
Standards
EN 50121-59EMC),EN 50155(temperature and humidity),EN61010-1/2 (safety)
Bandwidth
DC-30kHz
Mounting Style
Panel Mount
Operating Temperature Range
-40°C / 85°C
Accuracy
2%
Termination Style
Molex 436500300
Unit Weight
35g
Factory Pack Qty
4
Datasheet
Product Datasheet
Application Notes
FAQ