Search results for "텔레@upcoin24``이더리움전송대행리플매입"
-
CTB 160, 160mm Diameter CTB Series Core Balanced/Toroid CT (CBCT) for AC Earth Leakage Detection, for RCR Series Hobut Core balanced CT’s
Hobut CTB 160, 160Amp Measurement Core Balanced/Toroid CT's (CBCT) for AC Earth Leakage Detection Features Very low differential current measurement Applications Earth Leakage Specification Hobut Part Number CTB 160 Technology Core Balanced/Toroid (CBCT) Aperture Size 160mm Sizes Isolation 3kV (AC, 50Hz, 1 min) Bandwidth 50-60Hz Mounting Style Panel Mount Operating Temperature Range -15°C / 55°C Termination Style Maximum 2.5mm stranded or 4mm solid conductors Factory Pack Qty 3 Datasheet Product Datasheet Application Notes RCR-V30 Installation Guide
$226.00
$266.68 inclGST -
MT440-SSUDAAMNA, Multifunction Power Transducer, Class 0.5, 4 Wire, 600V L-N, 1/5/10Amp AC Input 50/60Hz, 24-300VDC or 40-276VAC Aux Input, 2 Programmable analogue outputs, 1 relay output, RS485 & USB Comms
Iskra Doo MT440-SSUDAAMNA, Multifunction Power Transducer, Class 0.5, 4 Wire, 600V L-N, 1/5/10Amp AC Input 50/60Hz, 24-300VDC or 40-276VAC Aux Input, 2 Programmable analogue outputs, 1 relay output, RS485 & USB Comms Class 0.5 (EN 60688) USB Comms as standard Up to 4 I/O Modules (analogue output, Multiple break point, non-linear characterstics Automatic range of nominal current up to 12.5 A (Includes 5A/1A CT Input) and nominal voltage up to 600 V L-N Adjustable tariff clock, display of electric energy consumption in optional currency RMS values of currents and voltages Measurements of active, reactive, apparent power and power factor Measurements of energy in all 4 quadrants Average values of measurands per interval Certified ship version available The Power Transducer is intended for measuring, analysing and monitoring single-phase or three-phase electrical power network. The meter records TRMS value according to the principle of fast sampling of voltage and current signals. A built-in microprocessor calculates measurands (voltage, current, frequency, energy, power, power factor, phase angles, etc.) from the measured signals. Features : Measurement of instantaneous values of more than 50 quantities (U, I, P, Q, S, PF, PA, f, f, MD, etc.). Accuracy class 0.5 32 Adjustable Alarms Input frequency 50/60 Hz or 400 Hz RS 232/RS485 communication up to 115,200 bit/s (Optional) or USB communication as standard MODBUS RTU communication protocol Up to 4 inputs or outputs (pulse outputs, alarm outputs, tariff inputs) Universal Supply 24-300VDC or 40-276VAC Automatic range of nominal current up to 12.5 A and nominal voltage up to 600 V User-friendly PC MiQen software Specification Iskra Doo Part Number MT440-SSUDAAMNA Functions 3 Phase Power Transducer Supply Voltage 24-300VDC or 40-276VAC Nominal Measurement Range 600V L-N, 1/5/10 Amp Maximum Measurement Range 600V L-N, 12.5 Amp Alarm 1 x Relay Output Tariff Input N/A Output(s) 2 x Analogue Accuracy Class 0.5 (I,U,F,PF,θ,THD) Class 1(Active), Class 2 (Reactive) Battery Backup N/A Real Time Clock 1min/month (30ppm) Isolation 3.5kV Comms USB (standard) RS232 2400-115200 b/s (RS485 Optional) Weight 370g Enclosure Material UL94, Factory Pack Qty 1 EU Directives EN61010, EN60688,EN61326-1,60529,60068-2-1/-2/-6/-27/-30 Safety Protection Class II 600V rms, installation category II 300V rms, installation category III Pollution Degree 2 in compliance with SIST EN 61010-1:2002 Enclosure Material PC/ABS non combustable-self-extinguishability, complying with UL 94 V-0 Enclosure Protection IP20 Shock Withstand 300g 8ms Pulse . 6 Shocks in each of 3 axes Vibration Withstand 0.7g, 3...100Hz, 1oct/min 10 cycles in each of three axes Operating Temperature -20 →+70 °C Datasheet Product Datasheet Software MiQen Setting Software MIPACK Programmer
$1,055.00
$1,244.90 inclGST -
FTH2553ZD3 + HS212, Solid State Relay, and Heatsink Assembly, 3 Phase 4-32VDC Control, 20 Amp per phase @ 40 Deg C, 48-530VAC Load, LED Status Indicator, with IP20 Cover
FTH2553ZD3 + HS212, Solid State Relay, and Heatsink Assembly, 3 Phase 4-32VDC Control, 20 Amp per phase @ 40 Deg C, 48-530VAC Load, LED Status Indicator, with IP20 Cover Features Ratings from 25A to 50 Amp @ 70-530 VAC SCR output for heavy industrial loads Zero voltage or Instantaneous turn-on outputs UL/CE/ROHS Approved IP20 Cover Available AC & DC control types Direct bond copper substrate Direct power lead frame Epoxy free design Spec Fastron Part Number FTH2553ZD3 + HS212DR Switching Type Zero Crossing ROHS/CE/UL Yes Control Voltage 4-32VDC Load Current 3 x 20 Amp (rms) per Phase Surge Capability 350 Amp (peak) Special Feature LED Status Indicator, with IP20 Cover Mounting Style Panel Mount Load Voltage Range 48-530VAC EMC Compliant Level 3 Termination Style Screw Unit Weight 315g Factory Pack Qty 10 Datasheet HS212 Datasheet D53TP Series 3 Phase SSR and Heatsink Mounted App Notes Why Use SSR's? The inside story Selecting a SSR DC Output SSR's Selecting a Suitable Heatsink Use of Thermal Interface Material How to Verify the Proper Heatsink Effect of Forced Air Cooling Fuse Protection of SSR's Overvoltage Protection "P" Option MOV SSR Reliability Whitepaper 3 Phase Motors and Heating Applications 3 Phase Motor Reversing How to test a SSR SSR Precautions SSR Life Expectancy MTBF ROHS & Reach Statement Heatsink SSR and Heatsink Assemblies
$239.00
$282.02 inclGST -
FTH2553ZD3 + HS212DR, Solid State Relay, and Heatsink Assembly, 3 Phase 3-32VDC Control, 20 Amp per phase @ 40 Deg C, 48-530VAC Load, LED Status Indicator, with IP20 Cover
FTH2553ZD3 + HS212DR, Solid State Relay, and Heatsink Assembly, 3 Phase 3-32VDC Control, 20 Amp per phase @ 40 Deg C, 48-530VAC Load, LED Status Indicator, with IP20 Cover Features Ratings from 25A to 50 Amp @ 70-530 VAC SCR output for heavy industrial loads Zero voltage or Instantaneous turn-on outputs UL/CE/ROHS Approved IP20 Cover Available AC & DC control types Direct bond copper substrate Direct power lead frame Epoxy free design Spec Fastron Part Number FTH2553ZD3 + HS212DR Switching Type Zero Crossing ROHS/CE/UL Yes Control Voltage 3-32VDC Load Current 3 x 20 Amp (rms) per Phase Surge Capability 350 Amp (peak) Special Feature LED Status Indicator, with IP20 Cover Mounting Style Din Rail Mount Load Voltage Range 48-530VAC EMC Compliant Level 3 Termination Style Screw Unit Weight 315g Factory Pack Qty 10 Datasheet HS212 Datasheet D53TP Series 3 Phase SSR and Heatsink Mounted App Notes Why Use SSR's? The inside story Selecting a SSR DC Output SSR's Selecting a Suitable Heatsink Use of Thermal Interface Material How to Verify the Proper Heatsink Effect of Forced Air Cooling Fuse Protection of SSR's Overvoltage Protection "P" Option MOV SSR Reliability Whitepaper 3 Phase Motors and Heating Applications 3 Phase Motor Reversing How to test a SSR SSR Precautions SSR Life Expectancy MTBF ROHS & Reach Statement Heatsink SSR and Heatsink Assemblies
$275.00
$324.50 inclGST -
G64B771, HV Relay, 50kVDC, 10A, SPST-NC, 12VDC Coil, 1,000,000 Cycles, 55kV Isolation, 72" Flying leads
Gigavac G64B771, HV Relay, 50kVDC, 10A, SPST-NC, 12VDC Coil, 1,000,000 Cycles, 55kV Isolation, 72" Flying leads Features Hermetically Sealed (Patented) rated to 85 Deg C High Efficiency DC Coils Gas filled Small and lightweight Flexible package for installation Specification Gigavac Part Number G64B771 Main Contact Type SPST-NC Auxiliary Contact Type N/A Coil Voltage 12VDC Load Current 10 Amp Mechanical Life @ 0 Amp 1,000,000 Operations Nominal Load Voltage 50kV rms Control Input Terminals 72" Flying Leads Special Feature N/A Mounting Style Panel Mount (M4) Peak Voltage 55kVDC Standards UL508, NEC 690.11 and 690.12 DC Termination Style Screw Unit Weight 335g Factory Pack Qty 1 Datasheet Product Datasheet
$2,795.00
$3,298.10 inclGST -
FTH2553ZA4 + HS212, Solid State Relay, and Heatsink Assembly, 3 Phase 90-280VAC Control, 20 Amp per phase @ 40 Deg C, 48-530VAC Load, LED Status Indicator, with IP20 Cover
FTH2553ZA4 + HS212, Solid State Relay, and Heatsink Assembly, 3 Phase 90-280VAC Control, 20 Amp per phase @ 40 Deg C, 48-530VAC Load, LED Status Indicator, with IP20 Cover Features Ratings from 25A to 50 Amp @ 70-530 VAC SCR output for heavy industrial loads Zero voltage or Instantaneous turn-on outputs UL/CE/ROHS Approved IP20 Cover Available AC & DC control types Direct bond copper substrate Direct power lead frame Epoxy free design Spec Fastron Part Number FTH2553ZA4 + HS212 Switching Type Zero Crossing ROHS/CE/UL Yes Control Voltage 90-280VAC Load Current 3 x 20 Amp (rms) per Phase Surge Capability 350 Amp (peak) Special Feature LED Status Indicator, with IP20 Cover Mounting Style Panel Mount Load Voltage Range 48-530VAC EMC Compliant Level 3 Termination Style Screw Unit Weight 315g Factory Pack Qty 10 Datasheet HS103DR D53TP Series 3 Phase SSR and Heatsink Mounted App Notes Why Use SSR's? The inside story Selecting a SSR DC Output SSR's Selecting a Suitable Heatsink Use of Thermal Interface Material How to Verify the Proper Heatsink Effect of Forced Air Cooling Fuse Protection of SSR's Overvoltage Protection "P" Option MOV SSR Reliability Whitepaper 3 Phase Motors and Heating Applications 3 Phase Motor Reversing How to test a SSR SSR Precautions SSR Life Expectancy MTBF ROHS & Reach Statement Heatsink SSR and Heatsink Assemblies
$205.00
$241.90 inclGST -
H31/110M + FTH2553ZD3, 3 Phase Solid State Relay, with Heatsink, IP20 Cover, Panel Mount, 25 Amps Per Phase @ 40 Deg C, with IP20 Cover
Fastron H31/110M + FTH2553ZD3, 3 Phase Solid State Relay, with Heatsink, IP20 Cover, Panel Mount, 25 Amps Per Phase @ 50 Deg C, 530VAC Load, with IP20 Cover Ratings from 25 to 120 Amp @ 70-480 VAC SCR output for heavy industrial loads Zero voltage or Instantaneous turn-on outputs IP20 Cover Included AC & DC control types Direct bond copper substrate Direct power lead frame Includes IP20 Cover Specification Fastron Part Number H31/110M + FTH2553ZD3 Switching Type Zero Crossing ROHS/CE/UL Yes Control Voltage 3-32VDC Load Current 3 x 25 Amp (rms) @ 50 Deg C Surge Capability 350 Amp (peak) Special Feature LED Status Indicator, with IP20 Cover Mounting Style Panel Mount Load Voltage Range 70-530VAC Dimensions L:110 x W:125 x D:180mm EMC Compliant Level 3 Termination Style Screw Unit Weight 2kg Factory Pack Qty 10 Datasheet Product Datasheet H31 Datasheet Equivalent Parts Contact Us for Possible Replacement
$255.00
$300.90 inclGST -
FT400160P, 4000/5 Amp Split Core CT, Class 0.5 15VA, 80 x 160mm Aperture, Dimensions 185 x 53 x 248mm
FT400160P, 4000/5 Amp Split Core CT, Class 0.5 15VA Series Current Transformer Features Quick Release Split Core System Built In Sealable Terminal Covers Mounting Feet Supplied Self Powered Rated System Voltage 0.72/3kV IEC185, BS 7626, BSEN 60044-1 and IEC 60044-1 Applications Metering Equipment Energy Monitoring AC Power Control Systems Power Factor Correction Power Quality Measurements Specification Fastron Electronics Part Number FT400160P Technology Split Core AC Current Transformer Ratio 4000/5 Aperture Size 80 x 160mm VA Rating 15VA Accuracy Class Class 0.5 Output 5 Amp AC (+20%) Isolation 3kV (AC, 50Hz, 1 min) Bandwidth 50-60Hz Mounting Style Panel Mount/Busbar Mount Operating Temperature Range -10°C / 50°C Continuous Current (max) 4000Amp x 1.2 Termination Style Screw Approvals UL, CE Unit Weight 1150g Factory Pack Qty 1 Datasheet Product Datasheet Installation Guide
$281.00
$331.58 inclGST -
FP150160P, 1500/5 Amp Split Core CT, Class 0.5, 15VA, 80 x 160mm Aperture, Dimensions 185 x 53 x 248mm
FP150160P, 1500/5 Amp Split Core CT, Class 0.5, 15VA Series Clip On Current Transformer Features Quick Release Split Core System Built In Sealable Terminal Covers Mounting Feet Supplied Self Powered Rated System Voltage 0.72/3kV IEC185, BS 7626, BSEN 60044-1 and IEC 60044-1 Applications Metering Equipment Energy Monitoring AC Power Control Systems Power Factor Correction Power Quality Measurements Specification Fastron Electronics Part Number FP150160P Technology Split Core AC Clip On Current Transformer Ratio 1500/5 Aperture Size 80 x 160mm VA Rating 15VA Accuracy Class Class 0.5 Output 5 Amp AC (+20%) Isolation 3kV (AC, 50Hz, 1 min) Bandwidth 50-60Hz Mounting Style Panel Mount/Busbar Mount Operating Temperature Range -30°C / 85°C Continuous Current (max) 1500Amp x 1.2 Certfications CE Termination Style Screw Unit Weight 3.5kg Factory Pack Qty 1 Datasheet Product Datasheet Installation Guide
$265.00
$312.70 inclGST -
TC Cable 500M Teflon - Type N, Thermocouple Cable 500 Meter Twisted and Screened 7/0.2mm, ANSI Standard
Heavy Item - No Free ShippingPremium Quality TC Cable 500M Teflon - Type R Thermocouple Cable 500 Meter Twisted and Screened 7/0.2mm, ANSI Standard Features CE, ANSI, ROHS Approved Colour Codes Datasheet Thermocouple Cable Brochure
Heavy Item - No Free Shipping$2,039.00
$2,406.02 inclGST -
RODN604025, Steel Enclosure, 600mmH x400mmW x 250mmD, IP66, RAL 7035 Gray 1.5mm Galvanised Steel
RODN604025, Steel Enclosure, 600mmH x400mmW x 250mmD, IP66, RAL 7035 Gray 1.5mm Galvanised Steel Features Injected Polyurethane Sealing gasket 3 x M20 cable glands 4pcs Wall Mounts and dynabolts included Lockable Door via Key RAL7035 GREY AS3000/AS3100 Compliant IP66 Specification Fastron Part Number RODN604025 Function Steel Water Proof Enclosure Configuration Enclosure with Hinged Door, Key Lock, 4 Mounting Clips, DYnabolts, and Cable Glands Termination Style Screw Dimensions H:600 x W:400 x D:250mm Weight 15.6kg Certification AS 3000 AS 3100 Factory Pack Qty 1 Material of housing 1.5mm Galvanised Steel Painted RAL 7035 Enclosure protection IP66 Operating Temperature -20...55 °C Datasheet Datasheet
$255.00
$300.90 inclGST -
MSD306R24UB Rotating Diode, 3/8" Top Stud, 3/4" Bottom Stud, Cathode Stud
Rotating Diode for Generators, MSD306R24UB, 3/8" Top Stud, 3/4" Bottom Stud, Cathode Stud User for Rotating Generator or Motor Applications 310 Amp Rating Datasheet Product Datasheet
$274.00
$323.32 inclGST