Fastron Electronics GT-P-P1-A-1, Signal Transmitter/Conditioner, 10K POT input, 4-20mA output, 100-240VAC/DC supply
Adjustable Zero and Span Setting
250mS Response Time
PC 94 UL V0
Input signals can be converted to insulated 4 to 20 mA DC output (for direct current output type)
Each unit needs just 22.5 x 114 mm depth DIN Rail cabinet space
Specification
Fastron Electronics Part Number
GTD-P-P1-A-1
Control Output
4-20mA
Input
10K Potentiometer
Over Range
N/A
Operating Temperature
0 - 60°C
Load Voltage
100 - 240VAC
Span Adjustment Range
+/-10%
Zero Adjustment Range
+/-5%
Termination Style
Screw
Mounting Style
DIN Rail Mount
Case Material
PC - UL 94 V0
Weight
170g
Factory Pack Qty
1
Datasheet
Product Datasheet
Fastron TTH-31-SA1-1, Air Temperature Sensor and Transmitter 6 x 150mm w/1M Cable
4-20mA Output 2 Wire
Temp Measurement for 0 to 100 Deg C Max
150 x 6mm with 1M Cable
20 Second Response Time
12-30VDC Supply 150mA max
Pt100 Temp Sensing Elements
Specification
Fastron Part Number
TTH-31-SA1-1
Sensor Type
RTD (Temperature)
No of Wires
2
Shaft Length
150mm
Shaft Thickness
6mm
Approvals
CE, ROHS
Cable length
1 Meter
Temperature Range
0 to 100 Deg C
Mounting Style
Through Hole
Weight
45g
Factory Pack Qty
1
Datasheet
Datasheet
Installation Guide
Wiring Diagram
Fastron Electronics FWBV414H29-150AC-420, AC Voltage Transducer, 0-150V AC input, 100-240VAC/DC aux, 4-20mA Average RMS output, 50/60Hz (25Hz - 1kHz Available on Request), Low Profile
Adjustable Zero and Span Setting
250mS Response Time
PC 94 UL V0
Input signals can be converted to insulated 4 to 20 mA DC output (for direct current output type)
Each unit needs just 42 x 50 mm depth DIN Rail cabinet space
Specification
Fastron Electronics Part Number
FWBV414H29-100AC-420
Control Output
4-20mA Average RMS
Input
0-150VAC, 50/60Hz (25Hz - 1kHz Available on Request)
Over Range
x 1.2 (Continuous)
Operating Temperature
-25 - 70°C
Load Voltage
100-240VAC/DC
Termination Style
Screw
Mounting Style
DIN Rail Mount
Dimensions
H:102 x W:42 x D:50mm
Standards
EN50022
Case Material
PC - UL 94 V0
Weight
250g
Factory Pack Qty
1
Datasheet
Product Datasheet
Northern Design Multicube Modular Digital Output Module
Up to 12 Pulse or Alarm outputs. Requires multicube modular master unit
Minimum 2 x 3 Phase Circuits with measurement module
Alternative master with logger
Optional pulse output modules
Requires Multicube Modular Master or Multicube Master with Logger
Optional 12 way pulse/alarm digital output modules
Nominal current up to 0.383V (For 0.333V CT Input) and nominal voltage up to 240V L-N 415V L-L
Graphic Display
Optional RS485 or Ethernet communication up to 19,200 bit/s
True RMS measurement of currents and voltages
The meter is intended for measuring, analysing and monitoring single-phase or three-phase electrical power network. The meter records TRMS value according to the principle of fast sampling of voltage and current signals. A built-in microprocessor calculates measurands (voltage, current, frequency, energy, power, reactive power, power factor, harmonics, etc.) from the measured signals.
Features :
Dual 3 phase Measurement Module
2 x 3 Phase or 6x Single Phase Circuits
Accuracy class 1
Simple Menu
Optional MODBUS RTU RS485 communication up to 19,200 bit/s or Ethernet communication
5 Year Warranty
240V AC power supply
Specification
Northern Design Part Number
Multicube Modular Master
Functions
kWh Meter, Energy Meter, Power Quality
Supply Voltage
240VAC < 15VA
Nominal Measurement Range
415V L-L 240V L-N, 0.333V
Maximum Measurement Range
480V L-L 280V L-N, 0.383V
Display
Graphic LCD
Pulse Output
12 (Optional)
Accuracy
Class 1 (kW,kWh) Class 1(Active), Class 2 Reactive
Ethernet
Optional
Real Time Clock
1min/month (30ppm)
Isolation
2.11kV
RS232/RS485
N/A (Optional 2400-19200 b/s)
Weight
150g
Certification
EN 61010-1 Installation Category III
Factory Pack Qty
1
Environment
IP54
Safety
Protection Class II
Enclosure Material
ABS with fire protection to UL94-V-O. Self extinguishing
EnclosureSize
164 x 96mm x 29mm
Terminals
Rising Cage 4mm² (12 AWG) cable max
Humidity
< 75% Non Condensing
Operating Temperature
-20 →+70 °C
Datasheet
Product brochure
User manual
Wiring Diagram
Suitable 0.333V CT's
Split Core CT's
Fastron Electronics SCT-F10-75-1A, 1 Amp Output, 75Amp Measurement, Class 1 Split Core CT's Class 1
Features
Quick Release Split Core System
Cable Mount
1 Amp Output
Self Powered
Rated System Voltage 0.60/3kV
0.5M Flying Leads
Applications
US Based Metering Equipment
Energy Monitoring
AC Power Control Systems
Power Factor Correction
Power Quality Measurements
Specification
Fastron Part Number
SCT-F10-75-1A
Technology
Split Core AC Current Transformer
Ratio
75/1Amp
Aperture Size
ø 8 mm
VA Rating
N/A
Accuracy Class
Class 1
Output
1 Amp (+20%)
Isolation
3kV (AC, 50Hz, 1 min)
Bandwidth
50-60Hz
Mounting Style
Cable Mount/Busbar Mount
Operating Temperature Range
-15°C / 45°C
Continuous Current (max)
50Amp x 1.2
Termination Style
0.5M Flying Leads
Unit Weight
100g
Factory Pack Qty
9
Datasheet
Product Datasheet
Application Notes
Installation Guide
FT063080P, 630/5 Amp Split Core CT, Class 1 3VA Series Current Transformer
Features
Quick Release Split Core System
Built In Sealable Terminal Covers
Mounting Feet Supplied
Self Powered
Rated System Voltage 0.72/3kV
IEC185, BS 7626, BSEN 60044-1 and IEC 60044-1
Applications
Metering Equipment
Energy Monitoring
AC Power Control Systems
Power Factor Correction
Power Quality Measurements
Specification
Fastron Part Number
FT063080P
Technology
Split Core AC Current Transformer
Ratio
630/5
Aperture Size
50 x 80mm
VA Rating
3VA
Accuracy Class
Class 1
Output
5 Amp AC (+20%)
Isolation
3kV (AC, 50Hz, 1 min)
Bandwidth
50-60Hz
Mounting Style
Panel Mount/Busbar Mount
Operating Temperature Range
-10°C / 50°C
Continuous Current (max)
630Amp x 1.2
Termination Style
Screw
Approvals
UL, CE
Unit Weight
1150g
Factory Pack Qty
1
Datasheet
Product Datasheet
Installation Guide
Crouzet Automation 84872140, Single Phase Voltage Control Relay Under/Over Voltage Detection - 17.5 mm MUS, 15-600VAC/DC Measurement, 12VDC Supply, 1 x C/O Relays, 250VAC/DC @ 5 Amp
For under and over voltage monitoring of Single phase AC or DC Voltages 65 to 260V
Features:
Control of AC and DC voltages
Automatic recognition of AC/DC
Measurement ranges from 65 V to 260 V
Choice between under and over voltage
True RMS measurement
Selectable latching (memory) function
Specification
Crouzet Part Number
84872140 (Single Phase MUS Voltage Monitoring Relay With Non-Latching SPDT Contacts)
Function
Undervoltage/Overvoltage
Supply Voltage
12VDC
Measurement Voltage
1 x 15 - 600 VAC/DC
Digital Outputs
1 x C/O Relays, 250VAC/DC @ 5 Amp
Min Breaking Current
10mA/5VDC
Delay on Threshhold Crossing
0.1 → 3s (0, +10%)
Delay on Pickup
600ms
Alarm Delay on Time (max)
200ms
Reset Time
1500ms
Adjustable Hysteresis
5 - 50% of Threshhold
Maximum Measurement Cycle Time
30ms/True RMS Measurement
Measurement Accuracy
1%
Supply Voltage Range
Same as Measurement
Termination Style
Screw
Weight
170g
Certification
CE, UL, CSA, GL, ROHS
Factory Pack Qty
1
Over Voltage Category
3 in accordance with IEC/EN 60664-1
Pollution Degree
2 in accordance with IEC/EN 61131-2
Protection rating
IP40 (Front), IP20 (Rear)
Mechanical Resistance
Immunity to vibrations IEC/EN 60068-2-6, test Fc
Immunity to shock IEC/EN 60068-2-27, test Ea
Resistance to HF Interference
Immunity to radiated electrostatic fields IEC/EN 61000-4-3 Immunity to fast transients (burst immunity) IEC/EN 61000-4-4, level 3 Immunity to shock waves IEC/EN 61000-4-5 Radio frequency in common mode IEC/EN 61000-4-6, level 3 Voltage dips and breaks (AC) IEC/EN 61000-4-11 Immunity to damped oscillatory waves IEC/EN 61000-4-12
Conducted and radiated emissions
Class B (*) in accordance with EN 55022, EN 55011 (CISPR22, CISPR11) group 1 (*) Except configuration (88 970 1.1 or 88 970 1.2) + (88 970 250 or 88 970 270) + 88 970 241 class A (class B in a metal enclosure)
Operating Temperature
-20 →+70 °C except CB and XB versions in VDC : -30 →+70 °C (+40 °C in a non-ventilated enclosure) in accordance with IEC/EN 60068-2-1 and IEC/EN 60068-22
Datasheet
Product Datasheet
C100N+100R, RC Snubber Network 275VAC, Class X2, 100uF 100 Ohm
These snubber neworks are suitable for transient supression in small contactors, bridge rectifers, or solid state relays switching AC or DC Loads. Easily connected or lugged to solid stage relay or power module terminals. See EMC filters, and Metal Oxide Varistors sections for additional supression components.
As and added bonus, these Snubber Networks Improve the Power Factor of switched loads.
Datasheet
Product Datasheet
FP025030P, 250/5 Amp Split Core CT, Class 1 1.5VA Series Clip On Current Transformer
Features
Quick Release Split Core System
Built In Sealable Terminal Covers
Mounting Feet Supplied
Self Powered
Rated System Voltage 0.72/3kV
IEC185, BS 7626, BSEN 60044-1 and IEC 60044-1
Applications
Metering Equipment
Energy Monitoring
AC Power Control Systems
Power Factor Correction
Power Quality Measurements
Specification
Fastron Part Number
FP025030P
Technology
Split Core AC Clip On Current Transformer
Ratio
250/5
Aperture Size
20 x 30mm
VA Rating
1.5VA
Accuracy Class
Class 1
Output
5 Amp AC (+20%)
Isolation
3kV (AC, 50Hz, 1 min)
Bandwidth
50-60Hz
Mounting Style
Panel Mount/Busbar Mount
Operating Temperature Range
-10°C / 50°C
Continuous Current (max)
250Amp x 1.2
Termination Style
Screw
Approvals
CE
Unit Weight
1150g
Factory Pack Qty
1
Datasheet
Product Datasheet
Installation Guide
Gigavac Contactor HX21CAC, Contactor SPST-NO 350 AMP, 1500VDC, 24VDC Coil, 38cm Flying leads, with SPST-NC Auxiliary Contact Continuous Duty, IP67, IP69
Features
Hermetically Sealed (Patented)
UL1604 for Class I & II Div 2 and Class III for use in hazardous locations
IP67 IP69
SAE J1171 External ignition protection
ISO8846 Protection against ignition around flammable gasses
CE Approved
High Efficiency Dual DC Coils - Very low 12,24,48VDC continuous coil power with no EMI emissions or cross-talk on your system control power
Ideal for battery powered systems or where low power is needed
PWM option provides additional drive control flexibility
Built in Coils suppression for all DC Coils
Flexible package for installation
Integrated safety cover
Specification
Gigavac Part Number
HX21CAC
Main Contact Type
SPST-NO
Auxiliary Contact Type
SPST-NC
Coil Voltage
24VDC
Load Current
350+ Amp
Mechanical Life @ 0 Amp
1,000,000 Operations
Dielectric at Sea Level (leakage <1mA)
4.3kV rms
Control Input Terminals
38cm Flying Leads
Aux Contact Terminals
38cm Flying Leads
Special Feature
N/A
Mounting Style
Panel Mount (M5)
Load Voltage Range
1000VDC
Standards
UL1604, IP67, IP69
Termination Style
M8
Unit Weight
440g
Factory Pack Qty
1
Datasheet
Product Datasheet
Fastron FP030030P, 300/5 Amp Split Core CT, Class 0.5 2.5VA AC Clip On Current Transformer, 20 x 30mm Aperture, Dimension 90 x 40 x 110mm
Features
Quick Release Split Core System
Built In Sealable Terminal Covers
Mounting Feet Supplied
Self Powered
Rated System Voltage 0.72/3kV
IEC185, BS 7626, BSEN 60044-1 and IEC 60044-1
Applications
Metering Equipment
Energy Monitoring
AC Power Control Systems
Power Factor Correction
Power Quality Measurements
Specification
Fastron Part Number
FP030030P
Technology
Split Core AC Clip On Current Transformer
Ratio
300/5
Aperture Size
20 x 30mm
VA Rating
1.5VA
Accuracy Class
Class 1
Output
5 Amp AC (+20%)
Isolation
3kV (AC, 50Hz, 1 min)
Bandwidth
50-60Hz
Mounting Style
Panel Mount/Busbar Mount
Operating Temperature Range
-10°C / 50°C
Continuous Current (max)
300Amp x 1.2
Termination Style
Screw
Approvals
CE
Unit Weight
1150g
Factory Pack Qty
1
Datasheet
Product Datasheet
Installation Guide
Rishabh Instruments Rish DPM 96x96 A DC-420-24, 96x96mm DC Ammeter, Panel Mount, 4-20mADC Input, 24VDC Aux Supply, 4.1 Digit 0-19999 range
Default display is mA, for other dsiplay parameter please advsie
Features
Adjustable Zero and Span Setting
Adjustable Display Scaling
Large 4.1 Digit 20.3mm (8 Inch) LED Display
250mS Response Time
PC 94 UL V0
Each unit needs just 96 x 96mm Panel Space
55mm Depth
CE Approved
Specification
Rishabh Part Number
Rish DPM 96x96 A DC-420-24
Conditioner Output
N/A
Input
4-20mA
Over Range
x 1.5
Operating Temperature
0 - 60°C
Supply Voltage
24VDC
Span Adjustment Range
+/-10%
Zero Adjustment Range
+/-5%
Termination Style
Screw
Display Type
4.1 Digit RED LED
Mounting Style
96 x 96mm (xD55mm)Panel Mount
Case Material
PC - UL 94 V0
Weight
320g
Factory Pack Qty
1
Datasheet
Product Datasheet
Application Notes
Panel Meters Blog Articles