Search results for "tg탤 banonpi 신용불량자소액작업대출 바넌피유심내구제 군산시기초수급자비대면소액대출 kt소액급전내구제대출 휴대폰내구제비대면"
-
FTA-005-420-24, DC Current Transducer, 0-5 Amp , 4-20mA Unipolar Output, 24VDC supply, 21mm Aperture
FTA-005-420-24, DC Current Transducer, 0-5 Amp , 4-20mA Unipolar Output, 24VDC supply, 21mm Aperture Compact and versatile Split Core DC current sensor, 0-5 Amp , 4-20mA Unipolar Output Features ⌀21mm Aperture DC Unipolar Measurement 4-20mA Instantaneous output 120mS Response (for 0- 0-10mA ~0-10A AC) 10uS Response (0-0-5A ~0-100A AC) Panel mount Isolated plastic case recognised according to UL94-V0 Advantages High isolation between primary and secondary circuits Easy installation DIN Rail Kit available Applications -Automation Systems Analogue current reading for remote monitoring (e.g. Motor) -Data Loggers Self Powered. Will not drain data logger batteries -Panel Meters Simple connection displays power consumption Specification Fastron Part Number FTA-005-420-24 Technology DC Current Transducer with Instant Output Yes Supply Voltage 24VDC Nominal Current (RMS + DC) 0-5 Amp Response Time < 120mS Output Unipolar 4-20mA Instant Isolation 2.5kV (AC, 50Hz, 1 min) Bandwidth DC Aperture 20mm Mounting Style Panel Mount Operating Temperature Range -10°C / 85°C Accuracy 1% Termination Style 4 Pin Plug (Included) Unit Weight 300g Factory Pack Qty 6 Datasheet Product Datasheet
$285.00
$336.30 inclGST -
DC-0-300-010-1.0, Hall Effect DC Current Transducer, 0-300 Amp DC, 0-10V Bipolar output, 24VDC supply
DC-0-300-010-1.0, Hall Effect DC Current Transducer, 0-300 Amp DC, 0-10V Bipolar output, 24VDC supply Compact and versatile Split Core DC current sensor, 0-300 Amp DC, 4-20 mA Bipolar Output Other measurement ranges available on request Features ⌀20mm Aperture DC Bipolar Measurement 0-10V analogue output Busbar, or DIN Rail Mounting Isolated plastic case recognised according to UL94-V0 Advantages High isolation between primary and secondary circuits Easy installation DIN Rail Kit available Applications -Automation Systems Analogue current reading for remote monitoring (e.g. Motor) -Data Loggers Self Powered. Will not drain data logger batteries -Panel Meters Simple connection displays power consumption Specification Fastron Part Number DC-0-300-010-1.0 Technology DC Hall Current Sensor with Process Output ROHS Yes Supply Voltage 24VDC Nominal Current (DC) 0-300 Amp Response Time < 1uS Output Bipolar 0-10V Isolation 2.5kV (AC, 50Hz, 1 min) Bandwidth DC Mounting Style DIN Rail Mount Operating Temperature Range -40°C / 85°C Accuracy 1% Termination Style Elevator Terminals Unit Weight 120g Factory Pack Qty 6 Datasheet Product Datasheet
$385.00
$454.30 inclGST -
DC-0-10-420B-1.0, Hall Effect DC Current Transducer, 0-10 Amp DC, 4-20mA Bipolar output, 24VDC supply
DC-0-10-420B-1.0, Hall Effect DC Current Transducer, 0-10 Amp DC, 4-20mA Bipolar output, 24VDC supply Compact and versatile Split Core DC current sensor, 0-10 Amp DC, 4-20 mA Bipolar Output Other measurement ranges available on request Features ⌀20mm Aperture DC Bipolar Measurement 4-20mA analogue output Busbar, or DIN Rail Mounting Isolated plastic case recognised according to UL94-V0 Advantages High isolation between primary and secondary circuits Easy installation DIN Rail Kit available Applications -Automation Systems Analogue current reading for remote monitoring (e.g. Motor) -Data Loggers Self Powered. Will not drain data logger batteries -Panel Meters Simple connection displays power consumption Specification Fastron Part Number DC-0-10-420B-1.0 Technology DC Hall Current Sensor with Process Output ROHS Yes Supply Voltage 24VDC Nominal Current (DC) 0-10 Amp Response Time < 1uS Output Bipolar 4-20mA Isolation 2.5kV (AC, 50Hz, 1 min) Bandwidth DC Mounting Style DIN Rail Mount Operating Temperature Range -40°C / 85°C Accuracy 1% Termination Style Elevator Terminals Unit Weight 120g Factory Pack Qty 6 Datasheet Product Datasheet
$385.00
$454.30 inclGST -
DC-0-200-420B-1.0, Hall Effect DC Current Transducer, 0-200 Amp DC, 4-20mA Bipolar output, 24VDC supply
DC-0-200-420B-1.0, Hall Effect DC Current Transducer, 0-200 Amp DC, 4-20mA Bipolar output, 24VDC supply Compact and versatile Split Core DC current sensor, 0-200 Amp DC, 4-20 mA Bipolar Output Other measurement ranges available on request Features ⌀20mm Aperture DC Bipolar Measurement 4-20mA analogue output Busbar, or DIN Rail Mounting Isolated plastic case recognised according to UL94-V0 Advantages High isolation between primary and secondary circuits Easy installation DIN Rail Kit available Applications -Automation Systems Analogue current reading for remote monitoring (e.g. Motor) -Data Loggers Self Powered. Will not drain data logger batteries -Panel Meters Simple connection displays power consumption Specification Fastron Part Number DC-0-200-420B-1.0 Technology DC Hall Current Sensor with Process Output ROHS Yes Supply Voltage 24VDC Nominal Current (DC) 0-200 Amp Response Time < 1uS Output Bipolar 4-20mA Isolation 2.5kV (AC, 50Hz, 1 min) Bandwidth DC Mounting Style DIN Rail Mount Operating Temperature Range -40°C / 85°C Accuracy 1% Termination Style Elevator Terminals Unit Weight 120g Factory Pack Qty 6 Datasheet Product Datasheet
$385.00
$454.30 inclGST -
H-400-MOD-24, Split Core Bipolar Hall Effect DC Current Transducer, +/-400 Amp DC, RS485 Modbus RTU output, 31mm aperture, 24VDC supply
Free Aus Post Shipping for $300 SpendH-400-MOD-24, Split Core Bipolar Hall Effect DC Current Transducer, +/-400 Amp DC, RS485 Modbus RTU output, 31mm aperture, 24VDC supply Compact and versatile Split Core Bipolar DC current sensor, +/-400 Amp DC, Modbus RS485output Features Modbus RTU (RS485)output ⌀31mm Aperture Split Core DC Measurement Busbar, or DIN Rail Mounting Isolated plastic case recognised according to UL94-V0 Advantages High isolation between primary and secondary circuits Easy installation DIN Rail Mount Applications -Automation Systems Analogue current reading for remote monitoring (e.g. Motor) -Data Loggers Self Powered. Will not drain data logger batteries -Panel Meters Simple connection displays power consumption Specification Fastron Part Number H-400-MOD-24 Technology DC Hall Effect Current Transducer with Processoutput ROHS Yes Supply Voltage 24VDC Nominal Current (DC) 0-400 Amp Response Time < 200mS Output RS485 Modbus RTU Isolation 2.5kV (AC, 50Hz, 1 min) Bandwidth DC Mounting Style DIN Rail Mount Operating Temperature Range -40°C / 85°C Accuracy 1% Termination Style Elevator Screw Unit Weight 200g Factory Pack Qty 6 Datasheet Product Datasheet
-
HTA 1000-S/SP16, O/L Hall Effect Current Sensor, 1000 Amp, +/-10V Output
Free Aus Post Shipping for $300 SpendLEM HTA 1000-S/SP16, O/L Hall Effect Current Sensor, 1000 Amp, +/-10V Output Features Bandwidth DC to 50kHz Open loop transducer using Hall effect Compact and versatile Panel mounting-Horizontal or Vertical Insulated plastic case recognized according to UL 94-V0 Advantages Very good linearity Very good accuracy Low temperature drift Wide frequency bandwidth Very low insertion losses High immunity to external interference Current overload capability Low power consumption Wide dynamic range, 100 to 1000 A in one package. Applications AC variable speed drives and servo motor drives Static converters for DC motor drives Battery supplied applications Uninterruptible Power Supplies (UPS) Switched Mode Power Supplies (SMPS) Power supplies for welding applications. Specification LEM Part Number HTA 1000-S/SP16 Technology Open Loop Hall Effect Aperture ø32mm ROHS Yes Supply Voltage +/-15 VDC Bipolar, Isolated Load Current (RMS + DC) 1000 Amp Measurement Range +/-1000 Amp Output +/-10 V Isolation 4 kV Bandwidth DC-50 kHz Mounting Style Panel Mount Operating Temperature Range -10°C / 80°C Accuracy 1% Termination Style Molex 5045-04A Unit Weight 230g Factory Pack Quantity 10 Datasheet Product Datasheet Application Notes LEM Applications Manual 3rd Edition
-
Xmer CT Split 105/50SC 200/5 Class 1 3.75VA, 43 x 55mm Aperture
Free Aus Post Shipping for $300 SpendXmer CT Split 105/50SC 200/5 Class 1 3.75VA, 43 x 55mm Aperture Features Quick Release Split Core System Built In Sealable Terminal Covers Mounting Feet Supplied Self Powered Rated System Voltage 0.72/3kV IEC185, BS 7626, BSEN 60044-1 and IEC 60044-1 Applications Metering Equipment Energy Monitoring AC Power Control Systems Power Factor Correction Power Quality Measurements Specification Rishabh Part Number Xmer CT Split 105/50SC 200/5 Class 1 3.75VA Technology Split Core AC Current Transformer Ratio 200/5 Aperture Size 43 x 55mm VA Rating 3.755VA Accuracy Class Class 1 Output 5 Amp AC (+20%) Isolation 3kV (AC, 50Hz, 1 min) Bandwidth 50-60Hz Mounting Style Panel Mount/Busbar Mount Operating Temperature Range -30°C / 85°C Continuous Current (max) 200Amp x 1.2 Termination Style Screw Unit Weight 800g Factory Pack Qty 9 Datasheet Product Datasheet
-
H-200-MOD-24, Split Core Bipolar Hall Effect DC Current Transducer, +/-200 Amp DC, RS485 Modbus RTU output, 31mm aperture, 24VDC supply
Free Aus Post Shipping for $300 SpendH-200-MOD-24, Split Core Bipolar Hall Effect DC Current Transducer, +/-200 Amp DC, RS485 Modbus RTU output, 31mm aperture, 24VDC supply Compact and versatile Split Core Bipolar DC current sensor, +/-200 Amp DC, Modbus RS485output Features Modbus RTU (RS485)output ⌀31mm Aperture Split Core DC Measurement Busbar, or DIN Rail Mounting Isolated plastic case recognised according to UL94-V0 Advantages High isolation between primary and secondary circuits Easy installation DIN Rail Mount Applications -Automation Systems Analogue current reading for remote monitoring (e.g. Motor) -Data Loggers Self Powered. Will not drain data logger batteries -Panel Meters Simple connection displays power consumption Specification Fastron Part Number H-200-MOD-24 Technology DC Hall Effect Current Transducer with Processoutput ROHS Yes Supply Voltage 24VDC Nominal Current (DC) 0-200 Amp Response Time < 200mS Output RS485 Modbus RTU Isolation 2.5kV (AC, 50Hz, 1 min) Bandwidth DC Mounting Style DIN Rail Mount Operating Temperature Range -40°C / 85°C Accuracy 1% Termination Style Elevator Screw Unit Weight 200g Factory Pack Qty 6 Datasheet Product Datasheet
-
FTCK-8-500-75, Type K Thermocouple MIMS Class A, 500 x 8mm Probe w/ Terminal Head, -20 to 1000 Deg C, CE ANSI ROHS Approved
Odd shaped Item No free ShippingFastron FTCK-8-500-75, Type K Thermocouple MIMS Class A, 500 x 8mm Probe w/ Terminal Head, -20 to 1000 Deg C, CE ANSI ROHS Approved Class A Accuracy Powder Coated Die Cast Alloy Terminal Head Low Long Term Drift Rated for -20 to 1000 Deg C Max Potted with Flying Leads 500 x 8mm MIMS Simplex 2 Wire Recommended to use BSP Fitting for mounting Specification Fastron Part Number FTCK-8-500-75 Sensor Type Type K Thermocouple No of Wires 2 Shaft Length 500mm SS316 Shaft Thickness 8mm Accuracy Class A Approvals CE, ANSI, ROHS Cable length 75mm Cable Type Teflon Temperature Range -20 to 1000 Deg C Special Feature High Temperature Potting Mounting Style BSP Bayonet or Flange Fitting Recommended Weight 370g Factory Pack Qty 1 Datasheet Datasheet
-
Elite E500C-5102, Panel Mount Network Recorder with Harmonics (15th), Class 0.5S, 50..500VAC 50/60Hz, RS485 Modbus RTU, 35..300V DC/85..300VAC Aux, 16MB Dual Logger , TFT Touch Screen, 10 Years Warranty
Secure Elite E500C-5102, Panel Mount Network Recorder with Harmonics (15th), Class 0.5S, 50..500VAC 50/60Hz RS485 Modbus RTU, 35..300V DC/85..300VAC Aux, 16MB Dual Logger , TFT Touch Screen, 10 Years Warranty Automatic range of nominal current up to 6 A (Includes 5A/1A CT Input) and nominal voltage up to 500 V L-L, 300V L-N Configurable 2 x Tariff Inputs or 2 x Pulse Outputs, or Alarm Outputs Dual Loggers, configurable for Instant or accumulated energy Configurable 2 x Tariff Inputs or 2 x Pulse Outputs, or Alarm Outputs RMS values of currents and voltages Measurements of active, reactive, apparent power and power factor Measurements of energy in all 4 quadrants Average values of measurands per interval RS 485 communication up to 38400 bit/s as standard Optional Protocol Modules Modbus TCP, BACNet IP, Profinet, SCADA EC61850 Optional Modules for Analogue outputs and Relay Alarms The meter is intended for measuring, analysing and monitoring single-phase or three-phase electrical power network. The meter records TRMS value according to the principle of fast sampling of voltage and current signals. A built-in microprocessor calculates measurands (voltage, current, frequency, energy, power, power factor, phase angles, etc.) from the measured signals. Features : Measurement of instantaneous values and accumulated energy. Includes Harmonics to the 15th Accuracy class 0.5S Dual Internal Loggers Measurement of 20 minimal and maximal values in different time periods RS 232/RS 485 communication up to 38400 bit/s or Ethernet communication MODBUS communication protocol Optional Protocol Modules Modbus TCP, BACNet IP, Profinet, SCADA EC61850 Configurable 2 x Tariff Inputs or 2 x Pulse Outputs, or Alarm Outputs Universal or AC/DC power supply Graphic Colour TFT 320 x 240 pixels (53x70mm) Automatic range of nominal current up to 6 A and nominal voltage up to 500 V Multilingual support User-friendly Free ECon Configuration software Specification Secure Part Number E500C-5102 Functions Network Recorder, Energy Meter Supply Voltage Universal 35..300V DC, 85..300VAC Nominal Measurement Range 240V L-N, 1/5 Amp, 415V L-L 1/5 Amp Maximum Measurement Range 300V L-N, 1/5 Amp, 500V L-L 1/5 Amp Alarm Optional Module 2 Relay/Pulse Outputs Tariff/Digital Inputs TOU Tarriff Clock Accuracy Class 0.5S (I,U,F,PF,θ,THD) Class 1(Active), Class 2 (Reactive) Analogue Output Optional Module 2 x Programmable Analogue Outputs Internal Memory 2 x 8MB Battery Backup N/A Real Time Clock 1min/month (30ppm) Isolation 3.5kV RS232/RS485 N/A Optional CT Termination Ring Terminals Weight 600g Certification CE, CSA, ROHS Warranty 10 Years from dispatch from Secure Warehouse Factory Pack Qty 1 EU Directives Degree on electrical equipment designed for use within certain voltage limits URLRS 53/00 (Directive 73/23/EEC on low voltage): SIST EN 61010-1:2002 Safety Requirement for electrical equipment for measurement, control and laboratory use, part1 : general requirement Decree on electromagnetic Compatibility (EMC) URLRS 61/00 (Directive 89/336/EEC on electromagnetic compatibility): SIST EN 61036 item 4.5: 1998 Meters for active energy (class 1 and 2) Safety Protection Class II 600V rms, installation category II 300V rms, installation category III Pollution Degree 2 in compliance with SIST EN 61010-1:2002 Enclosure Material PC/ABS non combustable-self-extinguishability, complying with UL 94 V-0 Enclosure Protection IP52 (IP00 for terminals) in compliance with SIST EN 60529:1997 Resistance to HF Interference Immunity to radiated electrostatic fields IEC/EN 61000-4-3 Immunity to fast transients (burst immunity) IEC/EN 61000-4-4, level 3 Immunity to shock waves IEC/EN 61000-4-5 Radio frequency in common mode IEC/EN 61000-4-6, level 3 Voltage dips and breaks (AC) IEC/EN 61000-4-11 Immunity to damped oscillatory waves IEC/EN 61000-4-12 Conducted and radiated emissions Class B (*) in accordance with EN 55022, EN 55011 (CISPR22, CISPR11) group 1 (*) Except configuration (88 970 1.1 or 88 970 1.2) + (88 970 250 or 88 970 270) + 88 970 241 class A (class B in a metal enclosure) Operating Temperature -20 →+70 °C Datasheet Product Datasheet Cross Reference The Following meters are close equivalents to Elite 500 Series. For further details please contact Fastron Sales Team Elite 500_400_300_100 series competition replacement for Schneider Siemens Accuenergy (RS485 +DNP3 default) Socomec Selec PM 5000 series PAC 2000 series ACCUVIM-CL + DNP3.0 DIRIS A-20 Selec MFM376 PM 5100 PAC 3200 ACCUVIM-CL + DNP3.0 DIRIS A-20 MFM384, CL-1, RS485 PM 5300 ACCUVIM-IIR DIRIS A-20 MFM383A PM 5500 PAC 4200 ACCUVIM-IIR(+ BACnet) DIRIS A-20 MFM384. RS485 PM 6463 Siemens 7KMPAC4200 ACCUVIM-IIR (+ Profibus) DIRIS A-30/ DIRIS - A60 (PQ Feature) MFM384-C-CE-CL05, RS485 PM 5650 ACCUVIM-IIR (+ IEC 61850) DIRIS A-30 + Profibus MFM384-C-CE-CL05, RS485 PM 5760 ACCUVIM-EL DIRIS A-30 +Ethernet MFM384-C-CE-CL05, RS485 PM5330 ACCUVIM-EL (+ BACnet) DIRIS A-30/ DIRIS A-60 PM 5560 ACCUVIM-EL (+ Profibus) DIRIS A-30/ DIRIS A-60 DM6200H ACCUVIM-EL (+ IEC 61850) PM2220 ACCUVIM-II R +Ethernet PM2230 / DM2120 (LED) PM 5350
$695.00
$820.10 inclGST -
HO 25-NSM-0000 Kit 5P, Evaluation Kit 5pcs with PCB
Free Aus Post Shipping for $300 SpendLEM HO 25-NSM-0000 Kit 5P Series Open Loop AC/DC Hall Effect Sensor Features Open loop multi-range current transducer Multirange through PCB routing Voltage output Single power supply +5 V Overcurrent detect 2.93 × IP N (peak value) Galvanic separation between primary and secondary circuit Low power consumption Compact design for THT PCB mounting Factory calibrated Dedicated parameter settings available on request Advantages Low offset drift Over-drivable Vref Creepage / clearance > 8 mm Fast response Applications AC variable speed and servo motor drives Static converters for DC motor drives Battery supplied applications Uninterruptible Power Supplies (UPS) Switched Mode Power Supplies (SMPS) Power supplies for welding applications Combiner box Solar inverter on DC side of the inverter (MPPT). Standards IEC 61800-1: 1997 IEC 61800-2: 2015 IEC 61800-3: 2004 IEC 61800-5-1: 2007 IEC 62109-1: 2010 UL 508: 2013. Application Domain Industrial. Specification LEM Part Number HO 25-NSM Kit 5pcs Technology Open Loop Hall Effect Aperture N/A ROHS Yes Supply Voltage 5 VDC Load Current (RMS + DC) 25 Amp Measurement Range +/-62.5 Amp Output 2.5 Vref Isolation 4.3 kV Bandwidth DC-100 kHz Mounting Style Surface Mount Operating Temperature Range -40°C / 105°C Accuracy 1% Termination Style PCB Surface Mount Unit Weight 34g Factory Pack Quantity 25 Datasheet Product Datasheet Application Notes LEM Applications Manual 3rd Edition
-
LT 4000-T C/L Hall Effect Current Sensor, Ipn = 4000 Amp, Isn = 800mA, +/-24VDC Supply, 10mm Bubsar Mount, X = 0.5%
Free Aus Post Shipping for $300 SpendLEM LT 4000-T C/L Hall Effect Current Sensor, Ipn = 4000 Amp, Isn = 800mA, +/-24VDC Supply, 10mm Bubsar Mount, X = 0.5% Features Bipolar and insulated current measurement up tp 6000 Amp Current output Bandwidth DC to 100kHz Closed loop (compensated) current transducer Panel mounting Insulated plastic case recognized according to UL 94-V0 Advantages Very good linearity High accuracy Low offset drift over temperature Wide frequency bandwidth Very low insertion losses High immunity to external interference Current overload capability Low power consumption Applications Windmill Inverters Test and Measurement Substations AC variable speed drives and servo motor drives Static converters for DC motor drives Battery supplied applications Uninterruptible Power Supplies (UPS) Switched Mode Power Supplies (SMPS) Power supplies for welding applications Application Domain Industrial Standards EN 50178:1997 IEC61010-1:2010 UL 508:2010 Specification LEM Part Number LT 4000-T Technology Closed Loop Hall Effect Aperture No Aperture ROHS Yes Supply Voltage +/- 15 VDC to +/- 24 VDC Bipolar, Isolated Load Current (RMS + DC) 4000 Amp Measurement Range +/- 6000 Amp Output 800 mA Isolation 6 kV Bandwidth DC-100 kHz Mounting Style Busbar Mount Operating Temperature Range -10°C / 85°C Accuracy 0.5% Termination Style M5 threaded studs Unit Weight 12.1kg Factory Pack Quantity 1 Datasheet Product Datasheet Application Notes LEM Applications Manual 3rd Edition