Search results for "tg@bitcoinsyri~~블랙테더코인전송이더리움구매"
-
D1D100, 3-32VDC Input, 100V, 100Amp DC Output Solid State Relay
Free Aus Post Shipping for $300 SpendCrydom D1D100, 3-32VDC Input, 100V, 100Amp DC Output Solid State Relay Features Ratings from 7A to 100 Amp @ 100-500VDC Mosfet output for reliable DC switching Multiple modules can be wired in parallel for higher currents UL/CSA/VDE Approved, CE Compliant to EN60950-1 Improved SEMS screw and washer Redesigned housing with anti-rotation barriers Direct bond copper substrate EMC compliant to Level 3 Direct power lead frame Epoxy free design Spec Crydom Part Number D1D100 Switching Type DC Load ROHS Yes (Details) Control Voltage 3.5-32VDC Load Current 100 Amp DC Surge Capability (10ms) 330 Amp DC Special Feature None Mounting Style Panel Mount Load Voltage Range 0 - 100VDC EMC Compliant Level 3 Termination Style Screw Unit Weight 75g Factory Pack Qty 20 Datasheet Product Datasheet Notifications Please note Changes from Gen 3 to Gen 4 (current) package design here App Notes Why Use SSR's? The inside story Selecting a SSR DC Output SSR's Selecting a Suitable Heatsink Use of Thermal Interface Material How to Verify the Proper Heatsink Effect of Forced Air Cooling Fuse Protection of SSR's Overvoltage Protection "P" Option MOV SSR Reliability Whitepaper 3 Phase Motors and Heating Applications 3 Phase Motor Reversing How to test a SSR SSR Precautions SSR Life Expectancy MTBF ROHS & Reach Statement Heatsink SSR and Heatsink Assemblies
-
FWBV414H29-300AC-010, AC Voltage Transducer, 0-300V AC input 100-240VAC/DC aux, 4-20mA Average RMS output, 50/60Hz (25Hz - 1kHz Available on Request), Low Profile
Fastron Electronics FWBV414H29-300AC-010, AC Voltage Transducer, 0-300V AC input 100-240VAC/DC aux, 4-20mA Average RMS output, 50/60Hz (25Hz - 1kHz Available on Request), Low Profile Adjustable Zero and Span Setting 250mS Response Time PC 94 UL V0 Input signals can be converted to insulated 4 to 20 mA DC output (for direct current output type) Each unit needs just 42 x 50 mm depth DIN Rail cabinet space Specification Fastron Electronics Part Number FWBV414H29-300AC-420 Control Output 4-20mA Average RMS Input 0-300VAC, 50/60Hz (25Hz - 1kHz Available on Request) Over Range x 1.2 (Continuous) Operating Temperature -25 - 70°C Load Voltage 100-240VAC/DC Termination Style Screw Mounting Style DIN Rail Mount Dimensions H:102 x W:42 x D:50mm Standards EN50022 Case Material PC - UL 94 V0 Weight 250g Factory Pack Qty 1 Datasheet Product Datasheet
$269.00
$317.42 inclGST -
HD48125G-10, Solid State Relay, Single Phase 4-32VDC Control, 125A, 48-530VAC Load, Random Crossing w/ Input status LED
Free Aus Post Shipping for $300 SpendCrydom HD48125G-10, Solid State Relay, Single Phase 4-32VDC Control, 125A, 48-530VAC Load, Random Crossing w/ Input status LED Features Ratings from 25A to 125 Amp @ 48-480VAC SCR output for heavy industrial loads Zero voltage or instantaneous turn-on outputs UL/CSA/VDE Approved, CE Compliant to EN60950-1 Improved SEMS screw and washer Redesigned housing with anti-rotation barriers AC & DC control types Direct bond copper substrate EMC compliant to Level 3 Direct power lead frame Epoxy free design Spec Crydom Part Number HD48125G-10 Switching Type Random Crossing ROHS Yes (Details) Control Voltage 4-32VDC Load Current 125 Amp (rms) Surge Capability 1670 Amp (peak) Special Feature LED Status Indicator Mounting Style Panel Mount Load Voltage Range 48-530VAC EMC Compliant Level 3 Termination Style Screw Unit Weight 75g Factory Pack Qty 20 Datasheet Product Datasheet Notifications Please note Changes from Gen 3 to Gen 4 (current) package design here Equivalent See HD48125-10 for version with No status LED App Notes Why Use SSR's? The inside story Selecting a SSR DC Output SSR's Selecting a Suitable Heatsink Use of Thermal Interface Material How to Verify the Proper Heatsink Effect of Forced Air Cooling Fuse Protection of SSR's Overvoltage Protection "P" Option MOV SSR Reliability Whitepaper 3 Phase Motors and Heating Applications 3 Phase Motor Reversing How to test a SSR SSR Precautions SSR Life Expectancy MTBF ROHS & Reach Statement Heatsink SSR and Heatsink Assemblies
-
MPFC-PF (PF24R1A), Power Factor Regulator, 24 Step, 1 Phase Measurement, 3 Phase Control, 50-530V 50/60HZ
MPFC-PF (PF12R1A)MPFC-PF (PF24R1A), Power Factor Regulator, 24 Step, 1 Phase Measurement, 3 Phase Control, 50-530V 50/60HZ Single CT Sensing 32nd Harmonic Measurement Isolated Switching of Power Factor Correction Contactors Cos ϕ Setting 0.9 to 0.9 CAP Auto CT Secondary Selection Backlit LCD Display Various Program Combinations IP41 Up to 12 steps Measurement System - Automatic/Manual 50-530VAC Measurement 100-132V / 207-253VAC (L-N) Aux Supply Configurable Alarms Dual Password Protection Programmable Fan Control Programmable 1A/5A CT Ratio Specification Beluk Part Number MPFC-PF / PF24R1A Function Reactive Power Correction Nominal Voltage (Un) 50-530VAC Line to Line Supply Voltage 100-132V / 207-253VAC (L-N), 45-65Hz, max fuse 6A Relay Rating 250VAC/5Amp Static Output Rating (T Models) 8-48VDC / 100mA Internal 2MB Logger Optional 3 x CT Measurement Optional Switch Delay Time 1s - 1200s User Adjustable Alarm 1 x Relay as above Temperature/Fan/THD Alarm 1 x Relay as above Re-connection Delay Time 50 - 1200s User Adjustable Desired Power Factor 0.90 IND - 0.90 CAP Number of Output Relays 12 Smallest Capacitor Current 10mA CT Input Range 15mA - 6 Amp LCD Display Accuracy Voltage +/-0.5%, Frequency +/-0.1%, Power +/-1% Energy Class 1 Phase Angle Error +/- 1% at I > 3% of range Comms Optional Termination Style Screw Weight 700g Certification IEC 654-1 Factory Pack Qty 1 Material of housing PC/ABS Unflammable, according to UL 94 V-0 Enclosure protection IP50 for case, IP20 for terminals Safety According to EN 61 010-1, installation category III Pollution degree 2 Operating Temperature -20...60 °C Datasheet Datasheet User Manual Beluk MPFC Slideshow Comparison with Circuitor Computer Smart II Fast 6 and CX Plus Application Notes Discharge Resistor Usage Power Factor Correction Blog Quick Start Guide(Blog)
$1,478.50
$1,744.63 inclGST -
MCBC2450CF, Solid Sate Relay based Burst Fire Controller, 240VAC, 50 Amp, 0-10V Input, 10 Cycles
Free Aus Post Shipping for $300 SpendCrydom MCBC2450CF, Solid Sate Relay based Burst Fire Controller, 240VAC, 50 Amp, 0-10V Input, 10 Cycles Features Selectable Proportional Burst Control Input Ratings from 25A to 90 Amp @ 180-530 VAC SCR output for heavy industrial loads Zero voltage turn-on outputs UL/CE/ROHS Compliant Direct bond copper substrate Direct power lead frame Epoxy free design Spec Crydom Part Number MCBC2450CF Switching Type Burst Fire (10 Cycles) ROHS/CE/UL Yes Control Voltage 0-10V Proportional Input Load Current 50 Amp (rms) Surge Capability 625Amp (peak) Special Feature Proportional Controller + SSR Mounting Style Panel Mount Load Voltage Range 180-280VAC Overvoltage Vpk 600V Termination Style Terminal Plug & Screws Unit Weight 87g Factory Pack Qty 10 Datasheet Product Datasheet Notifications Please note Changes from Gen 3 to Gen 4 (current) package design here Equivalent Crydom PMP2425W or Contact Us for Possible Replacement App Notes Why Use SSR's? The inside story Selecting a SSR DC Output SSR's Selecting a Suitable Heatsink Use of Thermal Interface Material How to Verify the Proper Heatsink Effect of Forced Air Cooling Fuse Protection of SSR's Overvoltage Protection "P" Option MOV SSR Reliability Whitepaper 3 Phase Motors and Heating Applications 3 Phase Motor Reversing How to test a SSR SSR Precautions SSR Life Expectancy MTBF ROHS & Reach Statement
-
TGLW26-1021250, 1 Pole Rotary Switch BLACK, 250 Amp 400VAC, Plastic, Direct Type, IEC60947-5-1
Free Aus Post Shipping for $300 SpendTGLW26-1021250, 1 Pole Rotary Switch BLACK, 250 Amp 400VAC, Plastic, Direct Type, IEC60947-5-1 Rotary Load Break or Disconnect Switches are used to Isolate or Switch under load. Widely Used for Rugged Industrial Applications Including Critical Machinery requiring safe operation by the user. Features : 400VAC in various Ratings 1 Pole Momentary 64mm x 64mm Cutout Standards : IP40 IEC60947-5-1 CE Specification TRENT Part Number TGLW26-1021250 Functions 1 Pole AC Disconnect Nominal Voltage 400VAC @ 50/60Hz Rated Impulse Voltage 6kV Nominal Current Range AC 250Amp @400VAC Rated Insulation Voltage 690VAC Humidity 35-85% Approvals CE Standards IEC 60947-1,-3, IEC 60204, IP20 (IP40 Installed) Weight 1.64kg Enclosure Material UL94V0 Factory Pack Qty 1 TRENT(Fastron) Head Office Australia Datasheet Datasheet
-
Smart ONE 75kvar 400VAC L-L, 75kVar Smart Capacitor Bank for Reactive Power Correction, IP21
Free Aus Post Shipping for $300 SpendFastron Electronics Smart ONE 75kvar 400VAC L-L, 75kVar Smart Capacitor Bank for Reactive Power Correction, IP21 For Automatic Switching of Power Factor Correction Capacitors according to changing site conditions. Features Automatic Power Factor Correction up to Cos φ = 0.95 Auto rotation of same capacitors for long life Overtemperature Alarm Optional RS485 Comms IEC 654-1, UL Approved 5 Year Fastron Electronics Warranty PR-14D.12, Automatic Reactive Power Controller 1 CT Sensing Automatic Power Factor Correction Automatic C/K Ratio Setting (0.05 -> 0.95) Cos ϕ Setting 0.85 to 0.95 CAP Backlit LCD Display Various Program Combinations IP41 Measurement System - Automatic/Manual 230VAC Aux Supply Optional Modbus RS485 Configurable Alarms Dual Password Protection Programmable Fan Control Programmable 1A/5A CT Ratio 2 x 10Kvar, 1 x 5Kvar Caps Specification Fastron Electronics Part Number Smart ONE 75kvar 400VAC Function Reactive Power Correction Steps 2 x 12.5kvar, 2 x 25kvar Dimensions W:475mm x D:215mm x L:610mm Nominal Voltage (Un) 110-440VAC Line to Line Supply Voltage 11-300VAC (L-N), 15VA 45-65Hz Relay Rating 250VAC/5Amp Switch Delay Time 1 - 999s User Adjustable Alarm 1 x Relay as above Temperature Alarm 1 x Relay as above Re-connection Delay Time 1 - 999s User Adjustable Desired Power Factor 0.80 IND - 0.80 CAP Number of Output Relays Up to 4 Smallest Capacitor Current (0.002 - 2A) x CT ratio CT Input Range 0 - 6 Amp, or 0-1.2Amp (three CT) LCD Display Accuracy Voltage +/-0.5%, Frequency +/-0.1%, Power +/-1% Energy Class 1 Phase Angle Error +/- 1% at I > 3% of range Comms RS485 (Optional) Termination Style Screw Weight 15kg Certification IEC 654-1, UL Factory Pack Qty 1 Material of housing PC/ABS Unflammable, according to UL 94 V-0, & Stainless Steel Painted RAL 1013 Enclosure protection IP21 Safety According to EN 61 010-1, installation category III Pollution degree 2 Operating Temperature -20...55 °C Datasheet Product Datasheet Controller user Manual Installation Guide MSDS for Vishay PhMKPg Series Capacitors
-
HS501DR + MCBC2425CF, Single Phase Proportional Burst Controller with Heatsink, 10 Cycles, 0-10VDC Input, 90-280VAC, 9 Amps
Free Aus Post Shipping for $300 SpendCrydom HS501DR + MCBC2425CF, Single Phase Proportional Burst Controller with Heatsink, 10 Cycles, 0-10VDC Input, 90-280VAC, 9 Amps Features Proportional Phase Control Input Ratings from 25A to 90 Amp @ 180-280 VAC SCR output for heavy industrial loads Zero voltage or instantaneous turn-on outputs UL/CE/ROHS Compliant Direct bond copper substrate Direct power lead frame Epoxy free design Spec Part Number HS501DR + MCBC2425CF Switching Type Burst Fire (Zero Crossing) ROHS/CE/UL Yes Control Voltage 0-10V Proportional Input Load Current 9 Amp (rms) @ 40 Deg C Surge Capability 239 Amp (peak) Special Feature Proportional Controller + SSR Mounting Style Din Rail or Panel Mount Load Voltage Range 180-280VAC Max Non Repetitive Peak Voltage 600 Vp Termination Style Screw Terminals Dimensions L:79.9mm x W:45mm x D:40.3mm Unit Weight 296g Factory Pack Qty 20 Datasheet HS501DR MCBC Series Notifications Please note Changes from Gen 3 to Gen 4 (current) package design here App Notes Why Use SSR's? The inside story Selecting a SSR DC Output SSR's Selecting a Suitable Heatsink Use of Thermal Interface Material How to Verify the Proper Heatsink Effect of Forced Air Cooling Fuse Protection of SSR's Overvoltage Protection "P" Option MOV SSR Reliability Whitepaper 3 Phase Motors and Heating Applications 3 Phase Motor Reversing How to test a SSR SSR Precautions SSR Life Expectancy MTBF ROHS & Reach Statement Heatsink SSR and Heatsink Assemblies
-
HS211 + MCBC2425CF, Single Phase Proportional Burst Controller with Heatsink, 10 Cycles, 0-10VDC Input, 90-280VAC, 24 Amps
Free Aus Post Shipping for $300 SpendCrydom HS211 + MCBC2425CF, Single Phase Proportional Burst Controller with Heatsink, 10 Cycles, 0-10VDC Input, 90-280VAC, 24 Amps Features Proportional Phase Control Input Ratings from 25A to 90 Amp @ 180-280 VAC SCR output for heavy industrial loads Zero voltage or instantaneous turn-on outputs UL/CE/ROHS Compliant Direct bond copper substrate Direct power lead frame Epoxy free design Panel Mount Din Rail Mount Spec Part Number HS211 + MCBC2425CF Switching Type Burst Fire (Zero Crossing) ROHS/CE/UL Yes Control Voltage 0-10V Proportional Input Load Current 24 Amp (rms) @ 40 Deg C Surge Capability 239 Amp (peak) Special Feature Proportional Controller + SSR Mounting Style Din Rail or Panel Mount Load Voltage Range 180-280VAC Max Non Repetitive Peak Voltage 600 Vp Termination Style Screw Terminals Dimensions L:81mm x W:45mm x D:73.4mm Unit Weight 296g Factory Pack Qty 20 Datasheet HS211 MCBC Series Notifications Please note Changes from Gen 3 to Gen 4 (current) package design here App Notes Why Use SSR's? The inside story Selecting a SSR DC Output SSR's Selecting a Suitable Heatsink Use of Thermal Interface Material How to Verify the Proper Heatsink Effect of Forced Air Cooling Fuse Protection of SSR's Overvoltage Protection "P" Option MOV SSR Reliability Whitepaper 3 Phase Motors and Heating Applications 3 Phase Motor Reversing How to test a SSR SSR Precautions SSR Life Expectancy MTBF ROHS & Reach Statement Heatsink SSR and Heatsink Assemblies
-
HS501DR + CWA2450P, Din Rail Mount Heatsink, 90-280VAC Control Input, LED Status, Varistor, High Surge, 24-280VAC Output, 10 Amp
Free Aus Post Shipping for $300 SpendCrydom HS501DR + CWA2450P, Din Rail Mount Heatsink, 90-280VAC Control Input, LED Status, Varistor, High Surge, 24-280VAC Output, 10 Amp Features Ratings from 25A to 125 Amp @24-280 VAC SCR output for heavy industrial loads Zero voltage or instantaneous turn-on outputs UL/CE/ROHS Compliant Direct bond copper substrate Direct power lead frame Epoxy free design Spec Part Number HS501DR + CWA2450P Switching Type Zero Crossing ROHS/CE/UL Yes Control Voltage 90-280VAC Load Current 10 Amp (rms) @ 40 Deg C Surge Capability 850 Amp (peak) Special Feature LED Status Indicator, High Surge, Overvoltage Protection Mounting Style Din Rail or Panel Mount Load Voltage Range 24-280VAC Max Non Repetitive Peak Voltage 600 Vp Termination Style Screw Terminals Dimensions L:79.9mm x W:45mm x D:40.3mm Unit Weight 296g Factory Pack Qty 20 Datasheet HS501DR CWA2450P Notifications Please note Changes from Gen 3 to Gen 4 (current) package design here App Notes Why Use SSR's? The inside story Selecting a SSR DC Output SSR's Selecting a Suitable Heatsink Use of Thermal Interface Material How to Verify the Proper Heatsink Effect of Forced Air Cooling Fuse Protection of SSR's Overvoltage Protection "P" Option MOV SSR Reliability Whitepaper 3 Phase Motors and Heating Applications 3 Phase Motor Reversing How to test a SSR SSR Precautions SSR Life Expectancy MTBF ROHS & Reach Statement Heatsink SSR and Heatsink Assemblies
-
MCBC4825DL, Solid Sate Relay based Burst Fire Controller, 4-20mA Input, 480VAC 25 Amp Load, 20 Cycles
Free Aus Post Shipping for $300 SpendCrydom MCBC4825DL, Solid Sate Relay based Burst Fire Controller, 4-20mA Input, 480VAC 25 Amp Load, 20 Cycles Features Selectable Proportional Burst Control Input Ratings from 25A to 90 Amp @ 180-530 VAC SCR output for heavy industrial loads Zero voltage turn-on outputs UL/CE/ROHS Compliant Direct bond copper substrate Direct power lead frame Epoxy free design Spec Crydom Part Number MCBC4825DL Switching Type Burst Fire (20 Cycles) ROHS/CE/UL Yes Control Voltage 4 - 20mA Proportional Input Load Current 25 Amp (rms) Surge Capability 250Amp (peak) Special Feature Proportional Controller + SSR Mounting Style Panel Mount Load Voltage Range 330-550VAC Overvoltage Vpk 1200V Termination Style Terminal Plug & Screws Unit Weight 87g Factory Pack Qty 10 Datasheet Product Datasheet Notifications Please note Changes from Gen 3 to Gen 4 (current) package design here Equivalent Crydom PMP2425W or Contact Us for Possible Replacement App Notes Why Use SSR's? The inside story Selecting a SSR DC Output SSR's Selecting a Suitable Heatsink Use of Thermal Interface Material How to Verify the Proper Heatsink Effect of Forced Air Cooling Fuse Protection of SSR's Overvoltage Protection "P" Option MOV SSR Reliability Whitepaper 3 Phase Motors and Heating Applications 3 Phase Motor Reversing How to test a SSR SSR Precautions SSR Life Expectancy MTBF ROHS & Reach Statement
-
SSC1000-25-12, 8-16VDC Input, 1kV, 25Amp DC Output SSR
Free Aus Post Shipping for $300 SpendCrydom SSC1000-25-12, 8-16VDC Input, 1kV, 25Amp DC Output SSR Features Ratings from 20 Amp @ 1-1000VDC Mosfet output for reliable DC switching Multiple modules can be wired in parallel for higher currents UL/CSA/VDE Approved, CE Compliant to EN60950-1 Improved SEMS screw and washer Redesigned housing with anti-rotation barriers Direct bond copper substrate EMC compliant to Level 3 Direct power lead frame Epoxy free design Spec Crydom Part Number SSC1000-25-12 Switching Type DC Load ROHS Yes (Details) Control Voltage 8-16VDC Load Current 25 Amp DC Surge Capability (10ms) 75 Amp DC Special Feature None Mounting Style Panel Mount Load Voltage Range 0 - 1000VDC EMC Compliant Level 3 Termination Style Screw Unit Weight 82g Factory Pack Qty 20 Datasheet Product Datasheet Notifications Please note Changes from Gen 3 to Gen 4 (current) package design here App Notes Why Use SSR's? The inside story Selecting a SSR DC Output SSR's Selecting a Suitable Heatsink Use of Thermal Interface Material How to Verify the Proper Heatsink Effect of Forced Air Cooling Fuse Protection of SSR's Overvoltage Protection "P" Option MOV SSR Reliability Whitepaper 3 Phase Motors and Heating Applications 3 Phase Motor Reversing How to test a SSR SSR Precautions SSR Life Expectancy MTBF ROHS & Reach Statement Heatsink SSR and Heatsink Assemblies