1241.2807, MCS 19, Metal Switch 19mm Short Stroke, 125mA @ 4-48VDC, 1 Million Ops
Free Aus Post Shipping for $300 SpendSchurter 1241.2807, MCS 19, Metal Switch 19mm Short Stroke, 125mA @ 4-48VDC, 1 Million Ops Description Momentary action switch available in version Standard, with Point Illumination, Lettering, varnished in different colours Assembly by mounting with nut Pin connections, Pins with Soldering Aid or Clip for Pins Characteristics Housing and actuator material types: zinc die-cast with nickel plating or stainless steel Wide range of materials, colours, lettering, colours of illumination - Switching voltage max. 48 VDC, switching current max. 125 mA Zinc die-cast for housing and actuator For indoor use, no illumination, no lettering Stainless Steel for actuator Optional point illumination and laser lettering with standard or customer-specific symbols Stainless Steel for housing and actuator for use in harsh environments outdoors (see technical data) Varnished Version Colour adjustments to customer housings possible, as standard: Signal colors red, green and yellow, optional: housing or actuator varnishing according to provided color specifications the varnished actuators are sealed by transparent lacqueur after the laser lettering Specification Schurter Part Number 1241.2807 Switching Type Standard Switch Size (Cutout) 19mm Cutout Nominal Voltage 4-48VDC Rated Power 1.2W Illumination voltage N/A Nominal Current (AC/DC) 125mA Contact Resistance ON/OFF <20m Ohm/ >10 M Ohm Dimensions ø22 x 15mm Operating Temperature Range -20°C / 60°C Termination Screw terminals IP Protection Rating IP67 with 0098.9201 Unit Weight 50g Factory Pack Qty 10 Datasheet Product Datasheet
-
1241.2815, MCS 19, Metal Switch 19mm Short Stroke, 125mA @ 4-48VDC, 1 Million Ops
Free Aus Post Shipping for $300 SpendSchurter 1241.2815, MCS 19, Metal Switch 19mm Short Stroke, 125mA @ 4-48VDC, 1 Million Ops Description Momentary action switch available in version Standard, with Point Illumination, Lettering, varnished in different colours Assembly by mounting with nut Pin connections, Pins with Soldering Aid or Clip for Pins Characteristics Housing and actuator material types: zinc die-cast with nickel plating or stainless steel Wide range of materials, colours, lettering, colours of illumination - Switching voltage max. 48 VDC, switching current max. 125 mA Zinc die-cast for housing and actuator For indoor use, no illumination, no lettering Stainless Steel for actuator Optional point illumination and laser lettering with standard or customer-specific symbols Stainless Steel for housing and actuator for use in harsh environments outdoors (see technical data) Varnished Version Colour adjustments to customer housings possible, as standard: Signal colors red, green and yellow, optional: housing or actuator varnishing according to provided color specifications the varnished actuators are sealed by transparent lacqueur after the laser lettering Specification Schurter Part Number 1241.2815 Switching Type Standard Switch Size (Cutout) 19mm Cutout Nominal Voltage 4-48VDC Rated Power 1.2W Illumination voltage N/A Nominal Current (AC/DC) 125mA Contact Resistance ON/OFF <20m Ohm/ >10 M Ohm Dimensions ø22 x 15mm Operating Temperature Range -20°C / 60°C Termination Pin terminals IP Protection Rating IP67 with 0098.9201 Unit Weight 50g Factory Pack Qty 10 Datasheet Product Datasheet
-
1241.2801 MCS 19 PI, Metal Switch Short Stroke, 125mA @ 4-48VDC, 1 Million Ops, w/Soldering Guide
Free Aus Post Shipping for $300 SpendSchurter 1241.2801 MCS 19 PI, Metal Switch Short Stroke, 125mA @ 4-48VDC, 1 Million Ops, w/Soldering Guide Description Momentary action switch available in version Standard, with Point Illumination, Lettering, varnished in different colours Assembly by mounting with nut Pin connections, Pins with Soldering Aid or Clip for Pins Characteristics Housing and actuator material types: zinc die-cast with nickel plating or stainless steel Wide range of materials, colours, lettering, colours of illumination - Switching voltage max. 48 VDC, switching current max. 125 mA Zinc die-cast for housing and actuator For indoor use, no illumination, no lettering Stainless Steel for actuator Optional point illumination and laser lettering with standard or customer-specific symbols Stainless Steel for housing and actuator for use in harsh environments outdoors (see technical data) Varnished Version Colour adjustments to customer housings possible, as standard: Signal colors red, green and yellow, optional: housing or actuator varnishing according to provided color specifications the varnished actuators are sealed by transparent lacqueur after the laser lettering Specification Schurter Part Number 1241.2801 Switching Type Momentary Switch Size 19mm Cutout Nominal Voltage 4-48VDC Rated Power 1.2W Illumination voltage N/A Nominal Current (AC/DC) 125mA Contact Resistance ON/OFF <20m Ohm/ >10 M Ohm Dimensions ø22 x 14.6mm Operating Temperature Range -20°C / 60°C Termination 200mm Flying leads IP Protection Rating Solder Pins Unit Weight 40g Factory Pack Qty 10 Datasheet Product Datasheet
-
AKR 5 C420L, AC Current Sensor, selectable 2, 5 Amp, True RMS 4-20mA output, 19mm round aperture
Free Aus Post Shipping for $300 SpendLEM AKR Series True RMS Solid Core AC Current Sensor with Process Outputs Compact and versatile Solid Core AC current sensor, selectable 2 or 5 Amp True RMS. Choice of output types: 4-20 mA, 0-5 V or 0-10 V Features Solid Core True RMS output 4-20mA current output Busbar, or panel mounting Isolated plastic case recognised according to UL94-V0 Advantages Large aperture for cable up to ⌀19mm High isolation between primary and secondary circuits Easy installation DIN Rail Kit available Applications -Automation Systems Analogue current reading for remote monitoring (e.g. Motor) -Data Loggers Self Powered. Will not drain data logger batteries -Panel Meters Simple connection displays power consumption Specification LEM Part Number AK 5 C420L Technology AC Current Transformer with Process Output ROHS Yes Supply Voltage 24VDC Loop Powered Nominal Current (RMS + DC) 2, 5 Amp Selectable Maximum Measurement Current (Peak) 3.4, 10.1 Amp Output 4-20mA True RMS Aperture ⌀19mm Isolation 3kV (AC, 50Hz, 1 min) Bandwidth 50-60Hz Mounting Style Panel Mount Operating Temperature Range -40°C / 85°C Accuracy 1% Termination Style 2 x UNC8 Cylindric Head Unit Weight 120g Factory Pack Qty 6 Datasheet Product Datasheet Application Notes LEM Applications Manual 3rd Edition
-
SDM630MCT-LORAWAN-MID-AU915, DIN Rail Mount kWh Meter, 3 Phase, 240VAC aux, Class 1, 1/5 Amp CT Connect, w/ 2 x pulse outputs and LoRaWaN AU915 Wireless Comms
SDM630MCT-LORAWAN-MID-AU915, DIN Rail Mount kWh Meter, 3 Phase, 240VAC aux, Class 1, 1/5 Amp CT Connect, w/ 2 x pulse outputs and LoRaWaN AU915 Wireless Comms 1/5 Amp CT Input LoRaWaN AU915 Optional Mbus Model available True RMS values of currents and voltages 1 x Configurable Pule Output (via Display Menu or Modbus) 1 x Fixed Pulse Output (1000imp/kwh) The meter is intended for measuring, and monitoring single-phase or 3 phase electrical power network. The meter records TRMS value according to the principle of fast sampling of voltage and current signals. A built-in microprocessor calculates measurands (voltage, current, frequency, energy, power to the 30th Harmonic) from the measured signals. Features : Accuracy class 1 Measurement of Active and Reactive Power Modbus RTU communication up to 38,400 bit/s communication Pulse output as standard Graphic LCD with illumination Specification Eastron Europe Part Number SDM630MCT-LORAWAN-MID-AU915 Functions Three Phase Energy Meter Supply Voltage 230V L-N +/-15% < 5VA Nominal Measurement Range 415V L-L 230V L-N, 1/5 Amp +/-15% Maximum Measurement Range 480V L-L 230V L-N, 1/5 Amp Nominal CT Current Input 1/5 Amp Pulse Output 2 x Passive, (1 x Configurable 60/100/200ms) Tariff Input N/A Accuracy Class 1 (I,U,F,kW,kWh) Class 2 (Reactive) Mounting Din Rail Real Time Clock 1min/month (30ppm) Internal Memory N/A Dimensions 72mm x 100mm x 66mm (4 modules wide) Isolation 4kV Comms LoRaWaN AS915 Weight 150g Certification EN 61010-1 Installation Category III Factory Pack Qty 1 Safety IP51(Indoor) Enclosure Material Noryl with fire protection to UL94-V-O. Self extinguishing Enclosure Size DIN 42880 4 Modules Operating Temperature -20 →+70 °C Documents Product Datasheet User Manual Modbus Protocol Setup Video - CT Ratio Unlock Modbus Utility EEM Meter Setting Software Utility
$339.00
$400.02 inclGST -
88974031, Millenium 3 Essential CB20-12I/8O R, 12 x On/Off inputs, Incl 6 analogue inputs, 8 x Static relay outputs incl 4 x PWM output, 24 VDC Supply, Green Display
Free Aus Post Shipping for $300 SpendCrouzet 88974031, Millenium 3 Essential CB20-12I/8O R, 12 x On/Off inputs, Incl 6 analogue inputs, 8 x Static relay outputs incl 4 x PWM output, 24 VDC Supply, Green Display Highly visible blue LCD with 4 lines of 18 characters and configurable backlighting More cost effective solution Allow the use of the entire library of specific functions blocs of the software workshop Extended temperature range (-20 °C →+70 °C) Analogue inputs 0-10 VDC, Potentiometer, NTC, LDR (0-20 mA/Pt100 with converters) Open to XN network communication extensions, digital I/O, analogue, Pt100 extensions HMI Screens Available Specification Crouzet Part Number 88974031 (CB20-12I/8O R) Analogue Inputs 0-10VDC (x6) Digital Inputs 12/24VDC (4.4mA @ 12VDC) (x16) Digital Outputs Relay, 5-30VDC,24-250VAC @ 10mA minimum (x10) PWM SSR Output 12-24VDC @ 500mA (x4) Expandable Yes LCD Display None Mounting Style DIN Rail Mount (124.6mm) Supply Voltage Range 24VDC (21.6 - 28.8VDC) Termination Style Screw Weight 350g Certification CE, UL, CSA, GL Factory Pack Qty 1 Over Voltage Category 3 in accordance with IEC/EN 60664-1 Pollution Degree 2 in accordance with IEC/EN 61131-2 Protection rating IP40 (Front), IP20 (Rear) Mechanical Resistance Immunity to vibrations IEC/EN 60068-2-6, test Fc Immunity to shock IEC/EN 60068-2-27, test Ea Resistance to HF Interference Immunity to radiated electrostatic fields IEC/EN 61000-4-3 Immunity to fast transients (burst immunity) IEC/EN 61000-4-4, level 3 Immunity to shock waves IEC/EN 61000-4-5 Radio frequency in common mode IEC/EN 61000-4-6, level 3 Voltage dips and breaks (AC) IEC/EN 61000-4-11 Immunity to damped oscillatory waves IEC/EN 61000-4-12 Conducted and radiated emissions Class B (*) in accordance with EN 55022, EN 55011 (CISPR22, CISPR11) group 1 (*) Except configuration (88 970 1.1 or 88 970 1.2) + (88 970 250 or 88 970 270) + 88 970 241 class A (class B in a metal enclosure) Operating Temperature -20 →+70 °C except CB and XB versions in VDC : -30 →+70 °C (+40 °C in a non-ventilated enclosure) in accordance with IEC/EN 60068-2-1 and IEC/EN 60068-22 Datasheet Product Datasheet Selection Chart Software Crouzet Touch Soft V6.00.02.173 Software M3-soft-AC9-V3.1.2.0_ML Remote Control Software CVD_PC_V2_3_01_02 Crouzet Soft EVO EM4 1.12.01.14
-
3-109-092, MCS 16, Metal Switch 16mm Short Stroke, 125mA @ 4-48VDC, 1 Million Ops, No Illumination, Pin Terminals, Ag Contact material, OFF - (ON), IP67
Schurter 3-109-081, MCS 16, Metal Switch 16mm Short Stroke, 125mA @ 4-48VDC, 1 Million Ops, Pin Terminals, Ag Contact material, OFF - (ON), IP67 Description Momentary action switch available in version Standard, with Point Illumination, Lettering, varnished in different colours Assembly by mounting with nut Pin connections, Pins with Soldering Aid or Clip for Pins Characteristics Housing and actuator material types: zinc die-cast with nickel plating or stainless steel Wide range of materials, colours, lettering, colours of illumination - Switching voltage max. 48 VDC, switching current max. 125 mA Zinc die-cast for housing and actuator For indoor use, no illumination, no lettering Stainless Steel for actuator Optional point illumination and laser lettering with standard or customer-specific symbols Stainless Steel for housing and actuator for use in harsh environments outdoors (see technical data) Varnished Version Colour adjustments to customer housings possible, as standard: Signal colors red, green and yellow, optional: housing or actuator varnishing according to provided color specifications the varnished actuators are sealed by transparent lacqueur after the laser lettering Specification Schurter Part Number 3-109-081 Switching Type Standard Switch Size (Cutout) 14.5 x ø16mm Nominal Voltage 4-48VDC Rated Power 1.2W Illumination voltage N/A Nominal Current (AC/DC) 125mA Contact Resistance ON/OFF <20m Ohm/ >10 M Ohm Dimensions ø19 x 15mm Operating Temperature Range -20°C / 60°C Termination Pins IP Protection Rating IP67 with 0098.9201 Unit Weight 40g Factory Pack Qty 10 Datasheet Product Datasheet
$9.75
$11.51 inclGST -
Sentinel 3+ Battery Impedance, Voltage and Temperature Sensor Gen 3+, Accuracy 0.5%, S-Bus Output
Free Aus Post Shipping for $300 SpendSentinel 3+ Battery Sensor Gen 3+, DIN Rail Mount Compact and versatile 3 in 1 Battery sensor for monitoring of critical battery systems, included Flooded Cell, and VLRA types. The Sentinel 3+ is a state of the art, System on Chip (SoC) digital transducer designed to monitor VRLA, gel or flooded stationary battery systems. Data is transmitted over a dedicated communication bus to proprietary and non-proprietary devices Features Din Rail Mount, Compact Design LED status indicator Temperature patch for direct battery measurement Communication interface isolation 2.16 kV Fast, simple fittings , Voltage, Temperature and True AC Impedance Measurement S-Bus Output (Interface with OEM equipment) Suitable for Transformerless UPS systems (may require Common mode Isolator) Isolated plastic case recognised according to UL94-V0 Advantages Excellent sensitivity, accuracy, and repeatability High current stimulation for secure impedance measurement Improved immunity to Common Mode transients in newer UPS topologies (ie. transformerless, using fast IGBTs and/or a floating battery with respect to earth ground). Applications UPS Telecommunications Battery supplied applications Application Domains Energy & Automation Industrial. Utilities Fire & Safety system Remote monitoring LEM Part Number BM Sentinel 3+ Technology SoC 3 in 1 sensor CE Approved Yes Supply Voltage 0.9 .. 16VDC @ 30mA Voltage Measurement Range 0.9 .. 16VDC @ 30mA Temperature Measurement Range -10°C / 70°C Output S-Bus Digital protocol Isolation 2.16kV (AC, 50Hz, 1 min) S-Bus Baud Rate 9600 bps Mounting Style Din Rail Mount Operating Temperature Range -10°C / 70°C Accuracy 0.5% Termination Style 6 Pin Connector (for BM CBL POW 0.4/0.6M) Unit Weight 70g Factory Pack Qty 6 Datasheet Used to monitor and measure battery Impedance, Voltage, and Surface Temperature. Product Datasheet S-Bus Protocol Information OEM Software Tools Sentinel 3 Commander Test Program Sentinel Troubleshooting Harsh EMC Application Notes In a UPS, the current drawn by the inverter contains line frequency harmonic components (mostly 2nd, 4th and 6th). Part of this ripple current flows through the battery, to which is connected the Sentinel. As the Sentinel itself uses an excitation current for the impedance measurement, so the presence of ripple current can interfere with the measurement and thus cause errors. The table below quantifies the additional error resulting from 1A rms of ripple current, for different combinations of ripple current harmonics and bloc voltage. Table 1: Additional errors for impedance measurement due to ripple current (See datasheet) Notes: The error values are the maximum, and are normalized for 1A rms of ripple current. The error is proportional to the ripple current; for example, if the ripple current was 2A rms the error will increase by factor 2.
-
AKR 50 C420L, AC Current Sensor, selectable 10, 20, 50 Amp, True RMS 4-20mA output, 19mm round aperture
Free Aus Post Shipping for $300 SpendLEM AKR Series True RMS Solid Core AC Current Sensor with Process Outputs Compact and versatile Solid Core AC current sensor, selectable 10, 20, 50 Amp True RMS. Choice of output types: 4-20 mA, 0-5 V or 0-10 V Features Solid Core True RMS output 4-20mA current output Busbar, or panel mounting Isolated plastic case recognised according to UL94-V0 Advantages Large aperture for cable up to ⌀19mm High isolation between primary and secondary circuits Easy installation DIN Rail Kit available Applications -Automation Systems Analogue current reading for remote monitoring (e.g. Motor) -Data Loggers Self Powered. Will not drain data logger batteries -Panel Meters Simple connection displays power consumption Specification LEM Part Number AK 50 C420L, Technology AC Current Transformer with Process Output ROHS Yes Supply Voltage 24VDC Loop Powered Nominal Current (RMS + DC) 10,20,50 Amp Selectable Maximum Measurement Current (Peak) 17,34,85 Amp Output 4-20mA True RMS Aperture ⌀19mm Isolation 3kV (AC, 50Hz, 1 min) Bandwidth 50-60Hz Mounting Style Panel Mount Operating Temperature Range -40°C / 85°C Accuracy 1% Termination Style 2 x UNC8 Cylindric Head Unit Weight 120g Factory Pack Qty 6 Datasheet Product Datasheet Application Notes LEM Applications Manual 3rd Edition
-
DHR 1000 C5, Hall Effect Current Sensor, 1000Amp RMS ,5V output, 32mm aperture
Free Aus Post Shipping for $300 SpendLEM DHR 1000 C5, Hall Effect Current Sensor, 1000Amp RMS ,5V output, 32mm aperture Compact and versatile transducers for high AC and DC currents from 100 to 1000A True RMS with signal conditioning. Choice of output types: 4-20 mA, 0-5 V or 0-10 V, Bandwidth: DC 20..6000 Hz Features VFD and SCR waveforms current measurement True RMS output 4-20mA current output Panel mounting Eliminates insertion loss Isolated plastic case recognised according to UL94-V0 Advantages Large aperture for cable up to ⌀32mm High isolation between primary and secondary circuits Easy installation Applications -VFD Controlled Loads VFD output indicates how the motor and attached load are operating -SCR Controlled Loads Accurate measurement of phase angle fired or burst fired(time proportional) SCR's. Current measurement gives faster response than temperature measurement -Application Domain Energy and Automation Specification LEM Part Number DHR 1000 C5 Technology Open Loop Hall Effect ROHS Yes Supply Voltage 20 - 50V Load Current (RMS + DC) 1000 Amp Output 0-5V Isolation 4kV (AC, 50Hz, 1 min) Bandwidth 20-6000Hz Mounting Style Panel Mount Operating Temperature Range -40°C / 70°C Accuracy Level 3 Termination Style SFKC 2.5/4-ST-5.08-RF(Phoenix Contact) Unit Weight 260g Factory Pack Qty 6 Datasheet Product Datasheet Application Notes LEM Applications Manual 3rd Edition 2026 LEM Application Guide
-
AK 200 C420L, AC Current Sensor, selectable 100, 150, 200 Amp, Average RMS 4-20mA output, 19mm round aperture
Free Aus Post Shipping for $300 SpendLEM AK 200 C420L Series Average RMS Solid Core AC Current Sensor with Process Outputs Compact and versatile Solid Core AC current sensor, selectable 100, 150, 200 Amp Average RMS. Choice of output types: 4-20 mA, 0-5 V or 0-10 V Features Solid Core Average RMS output 4-20mA current output Busbar, or panel mounting Isolated plastic case recognised according to UL94-V0 Advantages Large aperture for cable up to ⌀19mm High isolation between primary and secondary circuits Easy installation DIN Rail Kit available Applications -Automation Systems Analogue current reading for remote monitoring (e.g. Motor) -Data Loggers Self Powered. Will not drain data logger batteries -Panel Meters Simple connection displays power consumption Specification LEM Part Number AK 200 C420L, Technology AC Current Transformer with Process Output ROHS Yes Supply Voltage 24VDC Loop Powered Nominal Current (RMS + DC) 100,150,200 Amp Selectable Maximum Measurement Current (Peak) 120,180,240 Amp Output 4-20mA Average RMS Aperture ⌀19mm Isolation 3kV (AC, 50Hz, 1 min) Bandwidth 50-60Hz Mounting Style Panel Mount Operating Temperature Range -40°C / 85°C Accuracy 1% Termination Style 2 x UNC8 Cylindric Head Unit Weight 120g Factory Pack Qty 6 Datasheet Product Datasheet Application Notes LEM Applications Manual 3rd Edition
-
AK 200 C10, AC Current Sensor, selectable 100, 150, 200 Amp, Average RMS 0-10V output, 19mm round aperture
Free Aus Post Shipping for $300 SpendLEM AK 200 C10 Series Solid Core AC/DC Hall Effect Sensor with Process Outputs Compact and versatile Solid Core AC current sensor, selectable 100, 150, 200 Amp Average RMS. Choice of output types: 4-20 mA, 0-5 V or 0-10 V Features Solid Core Average RMS output 0-10V voltage output Busbar, or panel mounting Isolated plastic case recognised according to UL94-V0 Advantages Large aperture for cable up to ⌀19mm High isolation between primary and secondary circuits Easy installation DIN Rail Kit available Applications -Automation Systems Analogue current reading for remote monitoring (e.g. Motor) -Data Loggers Self Powered. Will nto drain data logger batteries -Panel Meters Simple connection displays power consumption Specification LEM Part Number AK 200 C10 Technology AC Current Transformer with Process Output ROHS Yes Supply Voltage Self Powered Nominal Current (RMS + DC) 100,150,200 Amp Selectable Maximum Measurement Current (Peak) 120,180,240 Amp Output 0-10V Average RMS Aperture ⌀19mm Isolation 3kV (AC, 50Hz, 1 min) Bandwidth 50-60Hz Mounting Style Panel Mount Operating Temperature Range -40°C / 85°C Accuracy 1% Termination Style 2 x UNC8 Cylindric Head Unit Weight 120g Factory Pack Qty 6 Datasheet Product Datasheet Application Notes LEM Applications Manual 3rd Edition