Search results for "후불유심현금화방법 탤ㄺ램 banonpi 당일급전가전내구제 바넌피선불유심내구제 서초구 무직자백수 소액급전 작업대출 안전비대면소액급전문의"
-
150NBF, 690V, 1050 Amp aR Semiconductor I²t Fuse BS88 Style
Trent 150NBF, 690V, 100 Amp aR Semiconductor I²t Fuse BS88 Style Features British Standard Fuse Links Package Wide Range of I²t Ratings up to 1050 Amp Busbar or Standoff Mounting IEC Standard 60269.1 AND 4 250 V Voltage Rating complying with IEC 33 Applications Protection of High Powered Semiconductors according to I²t Short Circuit Protection DC or AC Motor I²t Protection Battery Fuse Specification Trent Part Number 150NBF Fuse Type I²t AR Class Nominal Voltage 250VAC @ 50Hz I²t Rating 7400 A²/s Nominal Current (RMS + DC) 150 Amp Tested Breaking Capacity 100kA @ 250VAC Dimensions 82 x 47.3mm Hole Centers 65.5 - 48.2mm Mounting Style Busbar or Panel Mount with Standoff Operating Temperature Range -40°C / 125°C Watt Loss 27W Termination Style M6 Unit Weight 170g Factory Pack Qty 10 Datasheet Product Datasheet Cross Reference Chart
$36.80
$43.42 inclGST -
JIR301M Indicator, 48x96mm, 100-240VAC, 3 Alarm outputs, 4-20mA Retransmission
Free Aus Post Shipping for $300 SpendShinko JIR301M Series Digital Indicator Converter function are standard features 5-digit displays suit most industries including Temperature, Humidity, Pressure (0.5s response) Drip-proof / Dust-proof IP66 (front panel only) 3 Alarms as standard feature UL/CSA Approved Input signals can be converted to insulated 4 to 20 mA DC output Each unit needs just 96 x 48mm panel space EC Compliant (Details) Specification Shinko Part Number JIR301M Control Output N/A Input Multirange (refer to datasheet) Alarm 3 x Relay 3A(Resistive), 1A(Inductive load cos Ѳ=0.4) Option 1 Retransmission Mounting Style 96 x 48mm Panel Mount Supply Voltage 100 - 240VAC Termination Style Screw Weight 240g Factory Pack Qty 1 ROHS Yes UL Yes CE Yes Datasheet JIR Series Brochure JIR Series User Manual JIR Series Comms Manual
-
BA1-ND21-2, Indicator, 48x24mm, 5VDC, 4-20mA Input, 0-100.0 Display Range
BA1-ND21-2, Indicator, 48x24mm, 5VDC, 4-20mA Input, 0-100.0 Display Range 3.5-digit displays suit most industries including Temperature, Humidity, Pressure (0.5s response) Drip-proof / Dust-proof IP66 (front panel only) UL/CE Approved Each unit needs just 40 mm depth panel space EC Compliant Specification Hanyoung Nux Part Number BA1-ND21-2 Control Output 1 (Heat) N/A Control Output 2 (Cool) N/A Input 4-20mA (0-100.0) Alarm N/A Option 1 N/A Mounting Style 48 x 24mm Panel Mount Supply Voltage 5VDC Termination Style Screw Weight 250g Factory Pack Qty 1 ROHS Yes UL Yes CE Yes Datasheet BA1 Series Instruction Manual Free Software Hanyoung Nux TCS Software Hanyoung Nux TCS Software User Manual VX Series SB Driver (Windows 7) Not required for Windows 10 or 11
$69.50
$82.01 inclGST -
Smart ONE 62.5kvar 400VAC, 440VAC L-L, 62.5kVar Smart One Capacitor Bank for Reactive Power Correction, IP21
Heavy Item - No Free ShippingFastron Electronics Smart ONE 62.5kvar 400VAC L-L, 62.5kVar Smart One Capacitor Bank for Reactive Power Correction, IP21 For Automatic Switching of Power Factor Correction Capacitors according to changing site conditions. Features Automatic Power Factor Correction up to Cos φ = 0.95 Auto rotation of same capacitors for long life Overtemperature Alarm Optional RS485 Comms IEC 654-1, UL Approved 5 Year Fastron Electronics Warranty PR-14D.12, Automatic Reactive Power Controller 1 CT Sensing Automatic Power Factor Correction Automatic C/K Ratio Setting (0.05 -> 0.95) Cos ϕ Setting 0.85 to 0.95 CAP Backlit LCD Display Various Program Combinations IP41 Measurement System - Automatic/Manual 230VAC Aux Supply Optional Modbus RS485 Configurable Alarms Dual Password Protection Programmable Fan Control Programmable 1A/5A CT Ratio 2 x 10Kvar, 1 x 5Kvar Caps Specification Fastron Electronics Part Number Smart ONE 62.5kvar 400VAC Function Reactive Power Correction Steps 1 x 12.5kvar, 2 x 25kvar Dimensions W:475mm x D:215mm x L:610mm Nominal Voltage (Un) 110-550VAC Line to Line Supply Voltage 11-300VAC (L-N), 15VA 45-65Hz Relay Rating 250VAC/5Amp Switch Delay Time 1 - 999s User Adjustable Alarm 1 x Relay as above Temperature Alarm 1 x Relay as above Re-connection Delay Time 1 - 999s User Adjustable Desired Power Factor 0.80 IND - 0.80 CAP Number of Output Relays Up to 4 Smallest Capacitor Current (0.002 - 2A) x CT ratio CT Input Range 0 - 6 Amp, or 0-1.2Amp (three CT) LCD Display Accuracy Voltage +/-0.5%, Frequency +/-0.1%, Power +/-1% Energy Class 1 Phase Angle Error +/- 1% at I > 3% of range Comms RS485 (Optional) Termination Style Screw Weight 15kg Certification IEC 654-1, UL Factory Pack Qty 1 Material of housing PC/ABS Unflammable, according to UL 94 V-0, & Stainless Steel Painted RAL 1013 Enclosure protection IP21 Safety According to EN 61 010-1, installation category III Pollution degree 2 Operating Temperature -20...55 °C Datasheet Product Datasheet Controller user Manual Installation Guide MSDS for Vishay PhMKPg Series Capacitors
-
Smart ONE 100kvar 400VAC L-L, 100kVar Smart Capacitor Bank for Plug and Play Reactive Power Correction, IP21
Free Aus Post Shipping for $300 SpendFastron Electronics Smart ONE 100kvar 400VAC L-L, 100kVar Smart Capacitor Bank for Plug and Play Reactive Power Correction, IP21 For Automatic Switching of Power Factor Correction Capacitors according to changing site conditions. Features Automatic Power Factor Correction up to Cos φ = 0.95 Auto rotation of same capacitors for long life Overtemperature Alarm Optional RS485 Comms IEC 654-1, UL Approved 3 Year Fastron Electronics Warranty PR-14D.12, Automatic Reactive Power Controller 1 CT Sensing Automatic Power Factor Correction Automatic C/K Ratio Setting (0.05 -> 0.95) Cos ϕ Setting 0.85 to 0.95 CAP Backlit LCD Display Various Program Combinations IP41 Measurement System - Automatic/Manual 230VAC Aux Supply Optional Modbus RS485 Configurable Alarms Dual Password Protection Programmable Fan Control Programmable 1A/5A CT Ratio 2 x 10Kvar, 1 x 5Kvar Caps Specification Fastron Electronics Part Number Smart ONE 100kvar 400VAC Function Reactive Power Correction Steps 4 x 25kvar Dimensions W:475mm x D:215mm x L:610mm Nominal Voltage (Un) 110-440VAC Line to Line Supply Voltage 11-300VAC (L-N), 15VA 45-65Hz Relay Rating 250VAC/5Amp Switch Delay Time 1 - 999s User Adjustable Alarm 1 x Relay as above Temperature Alarm 1 x Relay as above Re-connection Delay Time 1 - 999s User Adjustable Desired Power Factor 0.80 IND - 0.80 CAP Number of Output Relays Up to 4 Steps 4 x 25kvar Smallest Capacitor Current (0.002 - 2A) x CT ratio CT Input Range 0 - 6 Amp, or 0-1.2Amp (three CT) LCD Display Accuracy Voltage +/-0.5%, Frequency +/-0.1%, Power +/-1% Energy Class 1 Phase Angle Error +/- 1% at I > 3% of range Comms RS485 (Optional) Termination Style Screw Weight 15kg Certification IEC 654-1, UL Factory Pack Qty 1 Material of housing PC/ABS Unflammable, according to UL 94 V-0, & Stainless Steel Painted RAL 1013 Enclosure protection IP21 Safety According to EN 61 010-1, installation category III Pollution degree 2 Operating Temperature -20...55 °C Datasheet Product Datasheet Controller user Manual Installation Guide MSDS for Vishay PhMKPg Series Capacitors
-
PMP2425W, Phase/Burst control, 240VAC, 25 Amp, Selectable 0-5V,0-10V,4-20mA input
Free Aus Post Shipping for $300 SpendCrydom PMP2425W, Phase/Burst control, 240VAC, 25 Amp, Selectable 0-5V,0-10V,4-20mA input Features Selectable Proportional Phase or Burst Control Input Ratings from 25A to 90 Amp @ 170-600 VAC SCR output for heavy industrial loads Zero voltage or Instantaneous turn-on outputs UL/CE/ROHS Compliant Direct bond copper substrate Direct power lead frame Epoxy free design Spec Crydom Part Number PMP2425W Switching Type Phase Angle or Burst (Selectable) ROHS/CE/UL Yes Control Voltage 0 - 10V/0 - 5V/4 - 20mA Proportional Input (Selectable) Note Requires DC Power Supply for 0-5V/0-10V input modes Load Current 25 Amp (rms) Surge Capability 286Amp (peak) Special Feature Proportional Controller + SSR Mounting Style Panel Mount Load Voltage Range 170-280VAC Dielectric Strength 4kV Termination Style Terminal Plug Unit Weight 160g Factory Pack Qty 20 Datasheet Product Datasheet PMP24 Installation/Wiring Guide Notifications Please note Changes from Gen 3 to Gen 4 (current) package design here Equivalent PMP2450WP RS1A Contact Us for Possible Replacement App Notes Why Use SSR's? The inside story Selecting a SSR DC Output SSR's Selecting a Suitable Heatsink Use of Thermal Interface Material How to Verify the Proper Heatsink Effect of Forced Air Cooling Fuse Protection of SSR's Overvoltage Protection "P" Option MOV SSR Reliability Whitepaper 3 Phase Motors and Heating Applications 3 Phase Motor Reversing How to test a SSR SSR Precautions SSR Life Expectancy MTBF ROHS & Reach Statement
-
Smart ONE 50kvar 400VAC, 440VAC L-L, 50kVar Smart One Capacitor Bank for Reactive Power Correction, IP21
Free Aus Post Shipping for $300 SpendFastron Electronics Smart ONE 50kvar 400VAC, 440VAC L-L, 50kVar Smart One Capacitor Bank for Reactive Power Correction, IP21 For Automatic Switching of Power Factor Correction Capacitors according to changing site conditions. Features Automatic Power Factor Correction up to Cos φ = 0.95 Auto rotation of same capacitors for long life Overtemperature Alarm Optional RS485 Comms IEC 654-1, UL Approved 5 Year Fastron Electronics Warranty PR-14D.12, Automatic Reactive Power Controller 1 CT Sensing Automatic Power Factor Correction Automatic C/K Ratio Setting (0.05 -> 0.95) Cos ϕ Setting 0.85 to 0.95 CAP Backlit LCD Display Various Program Combinations IP41 Measurement System - Automatic/Manual 230VAC Aux Supply Optional Modbus RS485 Configurable Alarms Dual Password Protection Programmable Fan Control Programmable 1A/5A CT Ratio 2 x 10Kvar, 1 x 5Kvar Caps Specification Fastron Electronics Part Number Smart ONE 50kvar 400VAC (12.5 + 16.7 + 25) Function Reactive Power Correction Steps 2 x 12.5kvar, 1 x 25kvar Dimensions W:475mm x D:215mm x L:610mm Nominal Voltage (Un) 110-550VAC Line to Line Supply Voltage 11-300VAC (L-N), 15VA 45-65Hz Relay Rating 250VAC/5Amp Switch Delay Time 1 - 999s User Adjustable Alarm 1 x Relay as above Temperature Alarm 1 x Relay as above Re-connection Delay Time 1 - 999s User Adjustable Desired Power Factor 0.80 IND - 0.80 CAP Number of Output Relays Up to 4 Smallest Capacitor Current (0.002 - 2A) x CT ratio CT Input Range 0 - 6 Amp, or 0-1.2Amp (three CT) LCD Display Accuracy Voltage +/-0.5%, Frequency +/-0.1%, Power +/-1% Energy Class 1 Phase Angle Error +/- 1% at I > 3% of range Comms RS485 (Optional) Termination Style Screw Weight 15kg Certification IEC 654-1, UL Factory Pack Qty 1 Material of housing PC/ABS Unflammable, according to UL 94 V-0, & Stainless Steel Painted RAL 1013 Enclosure protection IP21 Safety According to EN 61 010-1, installation category III Pollution degree 2 Operating Temperature -20...55 °C Datasheet Product Datasheet Controller user Manual Installation Guide MSDS for Vishay PhMKPg Series Capacitors
-
DRH3P60A18, 18 Amp AC Semiconductor Motor Controller & Contactor, 90-280VAC Control, 48-600VAC Load, Configuration_Auxiliary 2 x SPST (2 x NO)
Free Aus Post Shipping for $300 spendCrydom DRH3P60A18, 18 Amp AC Semiconductor Motor Controller & Contactor, 90-280VAC Control, 48-600VAC Load, Configuration_Auxiliary 2 x SPST (2 x NO) Features 20 Amp AC Semiconductor Motor Controller Load voltage range up to 600VAC Fits standard 35mm DIN Rail LED input status indicator AC or DC control Zero Voltage (resistive loads) or instantaneous (inductive loads) turn-on output C-UL-US Listed, CCC Certified, IEC Rated, CE & RoHS Compliant, Horsepower Rated Built-in Overvoltage Protection Ultra-efficient thermal management design (Patented) Spec Crydom Part Number DRH3P60A18 Switching Type Zero Crossing Approvals ROHS,CE,ULIEC Control Voltage 90-280VAC Transient Voltage 1200V Load Current (per phase) 18 Amp (rms) Surge Capability (10ms) 650 Amp (peak) Special Feature LED Status Indicator Mounting Style DIN Rail Mount Load Voltage Range 48-600VAC EMC Compliant Level 3 Termination Style Screw Unit Weight 197g Factory Pack Qty 20 Datasheet Product Datasheet App Notes Why Use SSR's? The inside story Selecting a SSR DC Output SSR's Selecting a Suitable Heatsink Use of Thermal Interface Material How to Verify the Proper Heatsink Effect of Forced Air Cooling Fuse Protection of SSR's Overvoltage Protection "P" Option MOV SSR Reliability Whitepaper 3 Phase Motors and Heating Applications 3 Phase Motor Reversing How to test a SSR SSR Precautions SSR Life Expectancy MTBF ROHS & Reach Statement Heatsink SSR and Heatsink Assemblies
-
FBT P BCM12.5 275 RM (4+0), Class I,II / Type 1,2 / B,C, AC Surge Protection Device (SPD) with Remote Contacts, 3 Pole 37.5kA,440VAC, DIN Rail Mount, L/N-PE, L-PEN, L-N, N-PE High Energy MOV Type
Free Aus Post Shipping for $300 SpendTrent FBT P BCM12.5 275 RM (4+0), Class I,II / Type 1,2 / B,C, AC Surge Protection Device (SPD) with Remote Contacts, 3 Pole 37.5kA,440VAC, DIN Rail Mount, L/N-PE, L-PEN, L-N, N-PE High Energy MOV Type Specifications Trent part number FBT P BCM12.5 275 RM (4+0) Nominal Voltage 440VAC No of Poles 4 Category IEC / EN / VDE Class I,II / Type 1,2 / B,C Location of use Main Distribution Boards Protection modes L/N-PE, L-PEN, L-N, N-PE High Energy MOV Additional Remote Contacts YES Protective element MOV Surge discharge rating Imax up to 37.5 kA(10/350us) / 100kA(8/20us) or 12.5kA(10/350us) / 60kA(8/20us) per pole Internal protection and safety Thermal disconnector in each MOV Standards IEC/EN 61643-11 Datasheet Product Datasheet
-
Thyro-PX-3PX-500-495-H-F, 3 Phase 3 Leg 500VAC SCR Burst/Phase Fire Power Controller, 495 Amp Per Phase @ 50 Deg C, With Current and Power Control Feedback, Voltage Sequence Control, Switch Operating Mode, MOSI Operating Mode
Advanced Energy Thyro-PX-3PX-500-495-H-F, 3 Phase 3 Leg 500VAC SCR Burst/Phase Fire Power Controller, 495 Amp Per Phase @ 50 Deg C, With Current and Power Control Feedback, Voltage Sequence Control, Switch Operating Mode, MOSI Operating Mode Features 230VAC-500VAC +10/-20% Line to Line. (Wider range with 24V Aux power supply) Voltage, Current or Power Control Molybdenum disilicide Ramp Operating Smallest footprint on the market Built in Fuses 3 Phase, Phase Angle & Burst Controller with SWITCH operation mode SWITCH between Phase(VAR) or Burst(TAKT) control modes (0)4-20mA, 0(1)-5V, 0(2)-10V or POT input Proportional Control Removable Cover USB Configuration/Bias Setting Potentiometer Adjustments Synchronisation Function for Multiple TAKT Sync Applications Electrical Ovens, Kilns, or Furnaces Arc Furnaces Molybdenum Disilicide Elements Silicon Carbide Elements DC Feedback Control from Transformer Secondary Chlorination, Electroplating Primary Control of Transformer Loads in Phase or Burst Fire mode Start on Short Circuit Load AC Soft Starter (VAR Mode Combined with PLC) Power Regulation Applications Electric Boilers Brewery Heating Industrial Light Dimming Suitable for extreme environments such as mining Incorporated Features Current Control/Feedback Programmable Relay Alarm Output Load Monitoring Analogue Output Power Control Feedback Communication Options Anybus Module Specification Advanced Energy Part Number Thyro-PX-3PX-500-495-H-F Approvals CE, UL508A, EU Directive 2014/35/EU & 2004/108/EC Control Accuracy 0.5% at rated voltage Rated Operating Temperature 50°C(CE) 45°C (UL) Temperature Derating Inom @ 50 Deg C, 1.1 x Inom @ 40 Deg C SCR Configuration Three Phase AC Switch Control Modes Phase(VAR), Burst(TAKT), Quick TAKT(QTM), Hybrid(VT on request), MOSI, VSC Control Input 4(0)-20mA, 0(1)-5V, 0(2)-10V, POT Load Current 495 Amp @ 50 Deg C (110% @ 40 Deg C Max) Control Range 0-100% Relays / Dry Contacts 3 Relay Outputs, 3 Dry Contacts Digital I/O 6 Digital Inputs Options (Optional) Conformal Coating for Gas or High Humidity Environments Mounting Style Panel Mount Supply Voltage Range 230VAC-500VAC +10/-20% Soft Start Via PLC input Termination Style Screw Unit Weight 2.1 to 140kg Factory Pack Qty 1 Technical Docs Brochure User Manual 2 Leg Control Application Blog Thyro A Series Quick Installation Guide Thyro Touch Software and Touch Display User Guide Setting Up Comms on Thyro A Series Controllers Anybus Device Ethernet IP Setup Guide
$25,349.00
$29,911.82 inclGST -
FBT Y PVM 1000 RM, 1000VDC Surge Protection Device for Photovoltaic Systems, Type 2 (Class II) 40kA WITH REMOTE C/O CONTACTS
FBT Y PVM 1000 RM, 1000VDC Surge Protection Device for Photovoltaic Systems, Type 2 (Class II) 40kA WITH REMOTE C/O CONTACTS Specifications Trent part number FBT Y PVM 1000 RM Nominal Voltage 1000VDC No of Poles 3 Category IEC / EN / VDE Type 2 (Class II) Location of use String Box, Inverter Protection modes (+)-PE,(-)-PE,(+)-(-) PE Additional Remote Contacts YES NO/NC/COM Protective element MOV No Fault/Fault Indication Green Flag / Not Green Flag Surge discharge rating Per pole 40kA (8/20uS)9KA) Max, 20kA (8/20uS)9KA) Nominal Internal protection and safety Thermal disconnector in each MOV Weight 420g Standards IEC614643-11:GB/T 18802.11: YD/T 1235.1, CE Datasheet Product Datasheet GDT/MOV/TVS Tester SPD Tester
$129.00
$152.22 inclGST -
FBT B PVM 600 RM, 600VDC Surge Protection Device for Photovoltaic Systems, Type 1 (CLass I) + Type 2 (CLass II) 40kA WITH REMOTE C/O CONTACTS
FBT B PVM 600 RM, 600VDC Surge Protection Device for Photovoltaic Systems, Type 1 (CLass I) + Type 2 (CLass II) 40kA WITH REMOTE C/O CONTACTS Specifications Trent part number FBT B PVM 600 RM Nominal Voltage 600VDC No of Poles 3 Category IEC / EN / VDE Type 1 (CLass I) + Type 2 (CLass II) Location of use String Box, Inverter Protection modes (+)-PE,(-)-PE,(+)-(-) PE Additional Remote Contacts YES NO/NC/COM Protective element MOV No Fault/Fault Indication Green Flag / Not Green Flag Surge discharge rating Per pole 40kA (8/20uS)9KA) Max, 20kA (8/20uS)9KA) Nominal Internal protection and safety Thermal disconnector in each MOV Weight 420g Standards IEC614643-11:GB/T 18802.11: YD/T 1235.1, CE Datasheet Product Datasheet GDT/MOV/TVS Tester SPD Tester
$129.00
$152.22 inclGST