Search results for "텔레@tetherzon$~트론리플전송대행리플코인대행"
-
Thyro ECO A1A 400-25 E L3, Thyro-A-1A-ECO Series Single Phase SCR Controller 25 Amp 230VAC +10%/-57%, Voltage Control only, Phase(VAR), Burst(TAKT), Switch Operating Mode
Advanced Energy Thyro A 1A ECO Series 3 Phase SCR Power Controller, 230VAC +10%/-57%, Voltage Control only, 25 to 125 Amp Ratings, Phase(VAR), Burst(TAKT), SWITCH Operating Modes Features 230VAC +10%/-57%, Voltage Control only +10/-57% Voltage Control Smallest footprint on the market 3 Phase, Phase Angle & Burst Controller with SWITCH operation mode SWITCH between Phase(VAR) or Burst(TAKT) control modes (0)4-20mA, 0(1)-5V, 0(2)-10V or POT input Proportional Control Fully enclosed IP20 Phase Angle(VAR), and Burst Fire(TAKT) switching Removable Cover USB Configuration/Bias Setting Synchronisation Function Digital Alarm Output Load Monitoring Applications Electrical Ovens, Kilns, or Furnaces Primary Control of Transformer Loads in Phase or Burst Fire mode AC Soft Starter (Combined with PLC) Power Regulation Applications Electric Boilers Brewery Heating Industrial Light Dimming Suitable for extreme environments such as mining Special Features Economic Model Specification Advanced Energy Part Number Thyro A 1A ECO Approvals CE, UL508A, EU Directive 2014/35/EU & 2004/108/EC Control Accuracy 3% at rated voltage Rated Operating Temperature 45°C SCR Configuration 3 Phase AC Switch Control Input 4(0)-20mA, 0(1)-5V, 0(2)-10V, POT Load Current 25 to 125 Amp @ 45 Deg C (110% @ 35 Deg C Max) Control Range 0-100% Options Conformal Coating for Gas or High Humidity Environments Mounting Style Panel Mount Supply Voltage Range 230VAC +10%/-57%, Voltage Control only +10/-15% (-57% with 24VDC Aux Supply) Soft Start Via PLC input Termination Style Screw Unit Weight 2.1 to 10kg Factory Pack Qty 1 Technical Docs Brochure User Manual Thyro A Series Quick Installation Guide Setting Up Comms on Thyro A Series Controllers Anybus Device Ethernet IP Setup Guide
$887.04
$1,046.71 inclGST -
Thyro Tool Pro Software CDROM - Software for Advanced Energy SCR Controller
Free Aus Post Shipping for $300 SpendSoftware for Advanced Energy SCR Controller For setting up Communication addresses via USB and configuring SCR Controllers Locally or remotely. Highly valueable for controller diagnostics, fault finding and communication validation. Basic Bus User Manual Thyro A Series Quick Installtion Guide
-
Thyro-ECO-A2A-400-25 E L3, Thyro-A-2A-ECO Series 2 Leg 3 Phase Burst(TAKT) Controller 25 Amp Rating, Voltage Control only, Most Economical Configuration, Suitable for Transformer Loads and Resistive Loads with 6:1-Hot Cold Ratio
Advanced Energy Thyro-ECO-A2A-400-25 E L3, Thyro-A-2A-ECO Series 2 Leg 3 Phase Burst(TAKT) Controller 25 Amp Rating, Voltage Control only, Most Economical Configuration, Suitable for Transformer Loads and Resistive Loads with 6:1-Hot Cold Ratio Features 230VAC +10/-57% Voltage Control Smallest footprint on the market 3 Phase, Phase Angle & Burst Controller with SWITCH operation mode SWITCH between Phase(VAR) or Burst(TAKT) control modes (0)4-20mA, 0(1)-5V, 0(2)-10V or POT input Proportional Control Fully enclosed IP20 Phase Angle(VAR), and Burst Fire(TAKT) switching Removable Cover USB Configuration/Bias Setting Synchronisation Function Digital Alarm Output Load Monitoring Applications Electrical Ovens, Kilns, or Furnaces Primary Control of Transformer Loads in Phase or Burst Fire mode AC Soft Starter (Combined with PLC) Power Regulation Applications Electric Boilers Brewery Heating Industrial Light Dimming Suitable for extreme environments such as mining Special Features Economic Model Specification Advanced Energy Part Number Thyro-ECO-A2A-400-25 E L3 Approvals CE, UL508A, EU Directive 2014/35/EU & 2004/108/EC Control Accuracy 3% at rated voltage Rated Operating Temperature 45°C SCR Configuration 3 Phase AC Switch Control Input 4(0)-20mA, 0(1)-5V, 0(2)-10V, POT Load Current 25 to 125 Amp @ 45 Deg C (110% @ 35 Deg C Max) Control Range 0-100% Options Conformal Coating for Gas or High Humidity Environments Mounting Style Panel Mount Supply Voltage Range 400VAC +10/-57% (-57% 24VDC Aux) Soft Start Via PLC input Termination Style Screw Unit Weight 2.1 to 10kg Factory Pack Qty 1 Technical Docs Brochure User Manual 2 Leg Control Application Blog Thyro A Series Quick Installtion Guide Setting Up Comms on Thyro A Series Controllers Anybus Device Ethernet IP Setup Guide
$1,795.86
$2,119.11 inclGST -
Thyro-A-3A-400-170-H-RLP3, Three Phase SCR Controller 170 Amp 400VAC +10/-57%, Phase(VAR), Burst(TAKT) Fire, SWITCH Operating Modes, Voltage Control, Current Feedback, Power Limit Options
Advanced Energy Thyro-A-3A-400-170-H-RLP3, Three Phase SCR Controller 170 Amp 400VAC +10/-57%, Phase(VAR), Burst(TAKT) Fire, SWITCH Operating Modes, Voltage Control, Current Feedback, Power Limit Options Features 400VAC +10/-57% Line to Line Voltage, Current or Power Control Smallest footprint on the market Built in Fuses 3 Phase, Phase Angle & Burst Controller with SWITCH operation mode SWITCH between Phase(VAR) or Burst(TAKT) control modes (0)4-20mA, 0(1)-5V, 0(2)-10V or POT input Proportional Control Removable Cover USB Configuration/Bias Setting Potentiometer Adjustments Synchronisation Function for Multiple TAKT Sync Applications Electrical Ovens, Kilns, or Furnaces Primary Control of Transformer Loads in Phase or Burst Fire mode Resistive Loads up to 6:1 Hot/Cold Ratio AC Soft Starter (VAR Mode Combined with PLC) Power Regulation Applications Electric Boilers Brewery Heating Industrial Light Dimming Suitable for extreme environments such as mining Series Optional Features For HRL Current Control/Feedback Programmable Relay Alarm Output Load Monitoring Analogue Output For HRLP As above with Power Control Feedback Communication Options Standard Thyro Bus Module BasicBus Module Specification Advanced Energy Part Number Thyro-A-3A-400-170-H-RLP3 Approvals CE, UL508A, EU Directive 2014/35/EU & 2004/108/EC Control Accuracy 3% at rated voltage Rated Operating Temperature 45°C Temperature Derating 0.9 x Inom @ 50 Deg C, 1.1 x Inom @ 35 Deg C SCR Configuration Three Phase AC Switch Control Modes Phase(VAR), Burst(TAKT), QUick TAKT(QTM), Hybrid(VT on request) Control Input 4(0)-20mA, 0(1)-5V, 0(2)-10V, POT Load Current 16 to 1500 Amp @ 45 Deg C (110% @ 35 Deg C Max) Control Range 0-100% Options Conformal Coating for Gas or High Humidity Environments Mounting Style Panel Mount Supply Voltage Range 400VAC +10/-57% (-57% with 24VDC Aux Supply) Soft Start Via PLC input Termination Style Screw Unit Weight 2.1 to 74kg Factory Pack Qty 1 Technical Docs Brochure User Manual 2 Leg Control Application Blog Thyro A Series Quick Installation Guide Setting Up Comms on Thyro A Series Controllers Anybus Device Ethernet IP Setup Guide
$8,534.90
$10,071.18 inclGST -
Thyro-A-3A-400-130-H-RLP3, Three Phase SCR Controller 130 Amp 400VAC +10/-57%, Phase(VAR), Burst(TAKT) Fire, SWITCH Operating Modes, Voltage Control, Current Feedback, Power Limit Options
Advanced Energy Thyro-A-3A-400-130-H-RLP3, Three Phase SCR Controller 130 Amp 400VAC +10/-57%, Phase(VAR), Burst(TAKT) Fire, SWITCH Operating Modes, Voltage Control, Current Feedback, Power Limit Options Features 400VAC +10/-57% Line to Line Voltage, Current or Power Control Smallest footprint on the market Built in Fuses 3 Phase, Phase Angle & Burst Controller with SWITCH operation mode SWITCH between Phase(VAR) or Burst(TAKT) control modes (0)4-20mA, 0(1)-5V, 0(2)-10V or POT input Proportional Control Removable Cover USB Configuration/Bias Setting Potentiometer Adjustments Synchronisation Function for Multiple TAKT Sync Applications Electrical Ovens, Kilns, or Furnaces Primary Control of Transformer Loads in Phase or Burst Fire mode Resistive Loads up to 6:1 Hot/Cold Ratio AC Soft Starter (VAR Mode Combined with PLC) Power Regulation Applications Electric Boilers Brewery Heating Industrial Light Dimming Suitable for extreme environments such as mining Series Optional Features For HRL Current Control/Feedback Programmable Relay Alarm Output Load Monitoring Analogue Output For HRLP As above with Power Control Feedback Communication Options Standard Thyro Bus Module BasicBus Module Specification Advanced Energy Part Number Thyro-A-3A-400-130-H-RLP3 Approvals CE, UL508A, EU Directive 2014/35/EU & 2004/108/EC Control Accuracy 3% at rated voltage Rated Operating Temperature 45°C Temperature Derating 0.9 x Inom @ 50 Deg C, 1.1 x Inom @ 35 Deg C SCR Configuration Three Phase AC Switch Control Modes Phase(VAR), Burst(TAKT), QUick TAKT(QTM), Hybrid(VT on request) Control Input 4(0)-20mA, 0(1)-5V, 0(2)-10V, POT Load Current 16 to 1500 Amp @ 45 Deg C (110% @ 35 Deg C Max) Control Range 0-100% Options Conformal Coating for Gas or High Humidity Environments Mounting Style Panel Mount Supply Voltage Range 400VAC +10/-57% (-57% with 24VDC Aux Supply) Soft Start Via PLC input Termination Style Screw Unit Weight 2.1 to 74kg Factory Pack Qty 1 Technical Docs Brochure User Manual 2 Leg Control Application Blog Thyro A Series Quick Installation Guide Setting Up Comms on Thyro A Series Controllers Anybus Device Ethernet IP Setup Guide
$7,658.20
$9,036.68 inclGST -
Smart ONE 100kvar 400VAC L-L, 100kVar Smart Capacitor Bank for Plug and Play Reactive Power Correction, IP21
Free Aus Post Shipping for $300 SpendFastron Electronics Smart ONE 100kvar 400VAC L-L, 100kVar Smart Capacitor Bank for Plug and Play Reactive Power Correction, IP21 For Automatic Switching of Power Factor Correction Capacitors according to changing site conditions. Features Automatic Power Factor Correction up to Cos φ = 0.95 Auto rotation of same capacitors for long life Overtemperature Alarm Optional RS485 Comms IEC 654-1, UL Approved 3 Year Fastron Electronics Warranty PR-14D.12, Automatic Reactive Power Controller 1 CT Sensing Automatic Power Factor Correction Automatic C/K Ratio Setting (0.05 -> 0.95) Cos ϕ Setting 0.85 to 0.95 CAP Backlit LCD Display Various Program Combinations IP41 Measurement System - Automatic/Manual 230VAC Aux Supply Optional Modbus RS485 Configurable Alarms Dual Password Protection Programmable Fan Control Programmable 1A/5A CT Ratio 2 x 10Kvar, 1 x 5Kvar Caps Specification Fastron Electronics Part Number Smart ONE 100kvar 400VAC Function Reactive Power Correction Steps 4 x 25kvar Dimensions W:475mm x D:215mm x L:610mm Nominal Voltage (Un) 110-440VAC Line to Line Supply Voltage 11-300VAC (L-N), 15VA 45-65Hz Relay Rating 250VAC/5Amp Switch Delay Time 1 - 999s User Adjustable Alarm 1 x Relay as above Temperature Alarm 1 x Relay as above Re-connection Delay Time 1 - 999s User Adjustable Desired Power Factor 0.80 IND - 0.80 CAP Number of Output Relays Up to 4 Steps 4 x 25kvar Smallest Capacitor Current (0.002 - 2A) x CT ratio CT Input Range 0 - 6 Amp, or 0-1.2Amp (three CT) LCD Display Accuracy Voltage +/-0.5%, Frequency +/-0.1%, Power +/-1% Energy Class 1 Phase Angle Error +/- 1% at I > 3% of range Comms RS485 (Optional) Termination Style Screw Weight 15kg Certification IEC 654-1, UL Factory Pack Qty 1 Material of housing PC/ABS Unflammable, according to UL 94 V-0, & Stainless Steel Painted RAL 1013 Enclosure protection IP21 Safety According to EN 61 010-1, installation category III Pollution degree 2 Operating Temperature -20...55 °C Datasheet Product Datasheet Controller user Manual Installation Guide MSDS for Vishay PhMKPg Series Capacitors
-
Thyro-ECO-A2A-400-50 E L3, Thyro-A-2A-ECO Series 2 Leg 3 Phase Burst(TAKT) Controller 50 Amp Rating, Voltage Control only, Most Economical Configuration, Suitable for Transformer Loads and Resistive Loads with 6:1-Hot Cold Ratio
Advanced Energy Thyro-ECO-A2A-400-50 E L3, Thyro-A-2A-ECO Series 2 Leg 3 Phase Burst(TAKT) Controller 50 Amp Rating, Voltage Control only, Most Economical Configuration, Suitable for Transformer Loads and Resistive Loads with 6:1-Hot Cold Ratio Features 230VAC +10/-57% Voltage Control Smallest footprint on the market 3 Phase, Phase Angle & Burst Controller with SWITCH operation mode SWITCH between Phase(VAR) or Burst(TAKT) control modes (0)4-20mA, 0(1)-5V, 0(2)-10V or POT input Proportional Control Fully enclosed IP20 Phase Angle(VAR), and Burst Fire(TAKT) switching Removable Cover USB Configuration/Bias Setting Synchronisation Function Digital Alarm Output Load Monitoring Applications Electrical Ovens, Kilns, or Furnaces Primary Control of Transformer Loads in Phase or Burst Fire mode AC Soft Starter (Combined with PLC) Power Regulation Applications Electric Boilers Brewery Heating Industrial Light Dimming Suitable for extreme environments such as mining Special Features Economic Model Specification Advanced Energy Part Number Thyro-ECO-A2A-400-50 E L3 Approvals CE, UL508A, EU Directive 2014/35/EU & 2004/108/EC Control Accuracy 3% at rated voltage Rated Operating Temperature 45°C SCR Configuration 3 Phase AC Switch Control Input 4(0)-20mA, 0(1)-5V, 0(2)-10V, POT Load Current 25 to 125 Amp @ 45 Deg C (110% @ 35 Deg C Max) Control Range 0-100% Options Conformal Coating for Gas or High Humidity Environments Mounting Style Panel Mount Supply Voltage Range 400VAC +10/-57% (-57% 24VDC Aux) Soft Start Via PLC input Termination Style Screw Unit Weight 2.1 to 10kg Factory Pack Qty 1 Technical Docs Brochure User Manual 2 Leg Control Application Blog Thyro A Series Quick Installtion Guide Setting Up Comms on Thyro A Series Controllers Anybus Device Ethernet IP Setup Guide
$2,139.39
$2,524.48 inclGST -
Thyro-ECO-A2A-400-125 E L3, Thyro-A-2A-ECO Series 2 Leg 3 Phase Burst(TAKT) Controller 125 Amp Rating, Voltage Control only, Most Economical Configuration, Suitable for Transformer Loads and Resistive Loads with 6:1-Hot Cold Ratio
Advanced Energy Thyro-ECO-A2A-400-125 E L3, Thyro-A-2A-ECO Series 2 Leg 3 Phase Burst(TAKT) Controller 125 Amp Rating, Voltage Control only, Most Economical Configuration, Suitable for Transformer Loads and Resistive Loads with 6:1-Hot Cold Ratio Features 230VAC +10/-57% Voltage Control Smallest footprint on the market 3 Phase, Phase Angle & Burst Controller with SWITCH operation mode SWITCH between Phase(VAR) or Burst(TAKT) control modes (0)4-20mA, 0(1)-5V, 0(2)-10V or POT input Proportional Control Fully enclosed IP20 Phase Angle(VAR), and Burst Fire(TAKT) switching Removable Cover USB Configuration/Bias Setting Synchronisation Function Digital Alarm Output Load Monitoring Applications Electrical Ovens, Kilns, or Furnaces Primary Control of Transformer Loads in Phase or Burst Fire mode AC Soft Starter (Combined with PLC) Power Regulation Applications Electric Boilers Brewery Heating Industrial Light Dimming Suitable for extreme environments such as mining Special Features Economic Model Specification Advanced Energy Part Number Thyro-ECO-A2A-400-125 E L3 Approvals CE, UL508A, EU Directive 2014/35/EU & 2004/108/EC Control Accuracy 3% at rated voltage Rated Operating Temperature 45°C SCR Configuration 3 Phase AC Switch Control Input 4(0)-20mA, 0(1)-5V, 0(2)-10V, POT Load Current 25 to 125 Amp @ 45 Deg C (110% @ 35 Deg C Max) Control Range 0-100% Options Conformal Coating for Gas or High Humidity Environments Mounting Style Panel Mount Supply Voltage Range 400VAC +10/-57% (-57% 24VDC Aux) Soft Start Via PLC input Termination Style Screw Unit Weight 2.1 to 10kg Factory Pack Qty 1 Technical Docs Brochure User Manual 2 Leg Control Application Blog Thyro A Series Quick Installtion Guide Setting Up Comms on Thyro A Series Controllers Anybus Device Ethernet IP Setup Guide
$3,077.91
$3,631.93 inclGST -
DTC1-A/M-TR, DIN Rail Mount Process Transmitter with Alarm Function, Multirange TC/RTD/4-20mA, 85-265VAC, 4-20mA output
Fastron DTC1-A/M-TR, DIN Rail Mount Process Transmitter with Alarm Function, Multirange TC/RTD/4-20mA, 85-265VAC, 4-20mA output Filter Time Constant Function Converter function 2 Input 1 Output, and 1 Input Two Output Versions available 4-digit display. Suit most industries including Temperature, Humidity, Pressure (0.5s response) CE Approved Each unit needs just 22.5mm width Din Rail space EC Compliant (Details) Various specials available for unique applications. Specification Fastron Part Number DTC1-A/M-TR Transmitter Output 4-20mA Input Multirange RTD/K/J/R/S/B/E/T/4-20mA/N/W1/W2 Alarm Relay 3A(Resistive), 1A(Inductive load cos ??=0.4), 240VAC/30VDC Options None Mounting Style 22.5 x 75mm Din Rail Mount Supply Voltage 85 - 265VAC Termination Style Screw Weight 230g Factory Pack Qty 1 CE Yes ?? Selection Chart Datasheet DTC1 Brochure DTC1User Manual DTC1 User Manual Comms versions Alarm Table DTC1 (Program Control Version) User Manual
$209.00
$246.62 inclGST -
Thyro-A-3A-400-16-H-RLP3, Three Phase SCR Controller 16 Amp 400VAC +10/-57%, Phase(VAR), Burst(TAKT) Fire, SWITCH Operating Modes, Voltage Control, Current Feedback, Power Limit Options
Advanced Energy Thyro-A-3A-400-16-H-RLP3, Three Phase SCR Controller 16 Amp 400VAC +10/-57%, Phase(VAR), Burst(TAKT) Fire, SWITCH Operating Modes, Voltage Control, Current Feedback, Power Limit Options Features 400VAC +10/-57% Line to Line Voltage, Current or Power Control Smallest footprint on the market Built in Fuses 3 Phase, Phase Angle & Burst Controller with SWITCH operation mode SWITCH between Phase(VAR) or Burst(TAKT) control modes (0)4-20mA, 0(1)-5V, 0(2)-10V or POT input Proportional Control Removable Cover USB Configuration/Bias Setting Potentiometer Adjustments Synchronisation Function for Multiple TAKT Sync Applications Electrical Ovens, Kilns, or Furnaces Primary Control of Transformer Loads in Phase or Burst Fire mode Resistive Loads up to 6:1 Hot/Cold Ratio AC Soft Starter (VAR Mode Combined with PLC) Power Regulation Applications Electric Boilers Brewery Heating Industrial Light Dimming Suitable for extreme environments such as mining Series Optional Features For HRL Current Control/Feedback Programmable Relay Alarm Output Load Monitoring Analogue Output For HRLP As above with Power Control Feedback Communication Options Standard Thyro Bus Module BasicBus Module Specification Advanced Energy Part Number Thyro-A-3A-400-16-H-RLP3 Approvals CE, UL508A, EU Directive 2014/35/EU & 2004/108/EC Control Accuracy 3% at rated voltage Rated Operating Temperature 45°C Temperature Derating 0.9 x Inom @ 50 Deg C, 1.1 x Inom @ 35 Deg C SCR Configuration Three Phase AC Switch Control Modes Phase(VAR), Burst(TAKT), QUick TAKT(QTM), Hybrid(VT on request) Control Input 4(0)-20mA, 0(1)-5V, 0(2)-10V, POT Load Current 16 to 1500 Amp @ 45 Deg C (110% @ 35 Deg C Max) Control Range 0-100% Options Conformal Coating for Gas or High Humidity Environments Mounting Style Panel Mount Supply Voltage Range 400VAC +10/-57% (-57% with 24VDC Aux Supply) Soft Start Via PLC input Termination Style Screw Unit Weight 2.1 to 74kg Factory Pack Qty 1 Technical Docs Brochure User Manual 2 Leg Control Application Blog Thyro A Series Quick Installation Guide Setting Up Comms on Thyro A Series Controllers Anybus Device Ethernet IP Setup Guide
$3,545.30
$4,183.45 inclGST -
Thyro-A-3A-500-130-H-RL3, Three Phase SCR Controller 130 Amp 500VAC +10/-57%, Phase(VAR), Burst(TAKT) Fire, SWITCH Operating Modes, Voltage Control, Current Feedback Option
Advanced Energy Thyro-A-3A-500-130-H-RL3, Three Phase SCR Controller 130 Amp 500VAC +10/-57%, Phase(VAR), Burst(TAKT) Fire, SWITCH Operating Modes, Voltage Control, Current Feedback Option Features 400VAC +10/-57% Line to Line Voltage, Current or Power Control Smallest footprint on the market Built in Fuses 3 Phase, Phase Angle & Burst Controller with SWITCH operation mode SWITCH between Phase(VAR) or Burst(TAKT) control modes (0)4-20mA, 0(1)-5V, 0(2)-10V or POT input Proportional Control Removable Cover USB Configuration/Bias Setting Potentiometer Adjustments Synchronisation Function for Multiple TAKT Sync Applications Electrical Ovens, Kilns, or Furnaces Primary Control of Transformer Loads in Phase or Burst Fire mode Resistive Loads up to 6:1 Hot/Cold Ratio AC Soft Starter (VAR Mode Combined with PLC) Power Regulation Applications Electric Boilers Brewery Heating Industrial Light Dimming Suitable for extreme environments such as mining Series Optional Features For HRL Current Control/Feedback Programmable Relay Alarm Output Load Monitoring Analogue Output For HRLP As above with Power Control Feedback Communication Options Standard Thyro Bus Module BasicBus Module Specification Advanced Energy Part Number Thyro-A-3A-500-130-H-RL3 Approvals CE, UL508A, EU Directive 2014/35/EU & 2004/108/EC Control Accuracy 3% at rated voltage Rated Operating Temperature 45°C Temperature Derating 0.9 x Inom @ 50 Deg C, 1.1 x Inom @ 35 Deg C SCR Configuration Three Phase AC Switch Control Modes Phase(VAR), Burst(TAKT), QUick TAKT(QTM), Hybrid(VT on request) Control Input 4(0)-20mA, 0(1)-5V, 0(2)-10V, POT Load Current 16 to 1500 Amp @ 45 Deg C (110% @ 35 Deg C Max) Control Range 0-100% Options Conformal Coating for Gas or High Humidity Environments Mounting Style Panel Mount Supply Voltage Range 400VAC +10/-57% (-57% with 24VDC Aux Supply) Soft Start Via PLC input Termination Style Screw Unit Weight 2.1 to 74kg Factory Pack Qty 1 Technical Docs Brochure User Manual 2 Leg Control Application Blog Thyro A Series Quick Installation Guide Setting Up Comms on Thyro A Series Controllers Anybus Device Ethernet IP Setup Guide
$6,112.70
$7,212.99 inclGST -
Smart ONE 25kvar 400VAC L-L, 25kVar Smart Capacitor Bank for Reactive Power Correction, IP21
Heavy Item - No Free ShippingFastron Electronics Smart ONE 25kvar 400VAC, Smart Capacitor Bank for Kvar Correction, Reactive Power Reduction, IP21 For Automatic Switching of Power Factor Correction Capacitors according to changing site conditions. Features Automatic Power Factor Correction up to Cos φ = 0.95 Auto rotation of same capacitors for long life Overtemperature Alarm Optional RS485 Comms IEC 654-1, UL Approved 5 Year Fastron Electronics Warranty PR-14D.12, Automatic Reactive Power Controller 1 CT Sensing Automatic Power Factor Correction Automatic C/K Ratio Setting (0.05 -> 0.95) Cos ϕ Setting 0.85 to 0.95 CAP Backlit LCD Display Various Program Combinations IP41 Measurement System - Automatic/Manual 230VAC Aux Supply Optional Modbus RS485 Configurable Alarms Dual Password Protection Programmable Fan Control Programmable 1A/5A CT Ratio 2 x 10Kvar, 1 x 5Kvar Caps Specification Fastron Part Number Smart ONE 25kvar 400VAC Function Reactive Power Correction Steps 1 x 12.5kvar, 1 x 7.5kvar 1 x 5kvar Dimensions W:475mm x D:215mm x L:610mm Nominal Voltage (Un) 110-550VAC Line to Line Supply Voltage 11-300VAC (L-N), 15VA 45-65Hz Relay Rating 250VAC/5Amp Switch Delay Time 1 - 999s User Adjustable Alarm 1 x Relay as above Temperature Alarm 1 x Relay as above Re-connection Delay Time 1 - 999s User Adjustable Desired Power Factor 0.80 IND - 0.80 CAP Number of Output Relays Up to 4 Smallest Capacitor Current (0.002 - 2A) x CT ratio CT Input Range 0 - 6 Amp, or 0-1.2Amp (three CT) LCD Display Accuracy Voltage +/-0.5%, Frequency +/-0.1%, Power +/-1% Energy Class 1 Phase Angle Error +/- 1% at I > 3% of range Comms RS485 (Optional) Termination Style Screw Weight 15kg Certification IEC 654-1, UL Factory Pack Qty 1 Material of housing PC/ABS Unflammable, according to UL 94 V-0, & Stainless Steel Painted RAL 1013 Enclosure protection IP21 Safety According to EN 61 010-1, installation category III Pollution degree 2 Operating Temperature -20...55 °C Datasheet Product Datasheet Controller user Manual Installation Guide MSDS for Vishay PhMKPg Series Capacitors