Fastron Electronics GT-DVO(5-15V)D-1, Signal Isolator/DC Voltage Transducer, 5-15VDC input, 22-60VAC/DC aux, 4-20mA output
Adjustable Zero and Span Setting
250mS Response Time
PC 94 UL V0
Input signals can be converted to insulated 4 to 20 mA DC output (for direct current output type)
Each unit needs just 22.5 x 114 mm depth DIN Rail cabinet space
Specification
Fastron Electronics Part Number
GT-DVO(5-15V)D-1
Control Output
4-20mA
Input
5-15VDC
Over Range
x 1.5
Operating Temperature
0 - 60°C
Load Voltage
100 - 240VAC/DC
Span Adjustment Range
+/-10%
Zero Adjustment Range
+/-5%
Termination Style
Screw
Mounting Style
DIN Rail Mount
Case Material
PC - UL 94 V0
Weight
170g
Factory Pack Qty
1
Datasheet
Product Datasheet
Fastron Electronics SCT-F50-1000-5A, 5 Amp, 1000Amp measurement Split Core CT's
Features
Quick Release Split Core System
Cable Mount
5 Amp Output
Self Powered
Rated System Voltage 0.60/3kV
0.9M Flying Leads
Applications
US Based Metering Equipment
Energy Monitoring
AC Power Control Systems
Power Factor Correction
Power Quality Measurements
Specification
Fastron Part Number
SCT-F50-1000-5A
Technology
Split Core AC Current Transformer
Ratio
1000/5 Amp
Aperture Size
ø 50 mm
VA Rating
N/A
Accuracy Class
Class 1
Output
5 Amp (+20%)
Isolation
3kV (AC, 50Hz, 1 min)
Bandwidth
50-60Hz
Mounting Style
Cable Mount/Busbar Mount
Operating Temperature Range
-15°C / 45°C
Continuous Current (max)
1000Amp x 1.2
Termination Style
0.9M Flying leads
Unit Weight
1000g
Factory Pack Qty
9
Datasheet
Product Datasheet
Stocked Split Core CT's Listing
Application Notes
Installation Guide
Types of Current Transformers - Blog
Cable Losses and CT's
High Accuracy or High Burden Requirements for CT's
Fastron Electronics SCT-F24-5, 0.333v, 5Amp Measurement, Class 1 Split Core CT's
Features
Quick Release Split Core System
Cable Mount
0.333v Output
Self Powered
Rated System Voltage 0.60/3kV
0.9M Flying Leads
Applications
US Based Metering Equipment
Energy Monitoring
AC Power Control Systems
Power Factor Correction
Power Quality Measurements
Specification
Fastron Part Number
SCT-F24-5
Technology
Split Core AC Current Transformer
Ratio
5/0.333v
Aperture Size
ø 24 mm
VA Rating
N/A
Accuracy Class
Class 1
Output
0.333v (+20%)
Isolation
3kV (AC, 50Hz, 1 min)
Bandwidth
50-60Hz
Mounting Style
Cable Mount/Busbar Mount
Operating Temperature Range
-15°C / 45°C
Continuous Current (max)
5Amp x 1.2
Termination Style
0.9M Flying leads
Unit Weight
100g
Factory Pack Qty
9
Datasheet
Product Datasheet
Application Notes
Installation Guide
TRIB-22D-B-24, 22mm LED Pushbutton & Indicator BLUE 24AC/DC, Plastic, IEC60947-5-1
Pushbutton Indicator Switches are a combinations of LED indicator Series and Momentary Pushbutton Switches. LED Will activate while the contacts are connected. Widely Used for Rugged Industrial Applications Including Critical Machinery requiring safe operation by the user.
Features :
240VAC or 24AC/DC (400VAC Special Orders)
1 Pole Momentary
LED Illumination
Rated for 6 Amp @ 240VAC, or 0.3 Amp @ 240VDC
Ø 22.5mm Cutout
Standards :
IP40
IEC60947-5-1
CE
Specification
TRENT Part Number
TRIB-22D-B-24
Functions
Momentary
Nominal Voltage
24AC/DC @ 50/60Hz
Impulse Voltage Wear Resistance
6kV
Illumination Type
Blue LED
Short Circuit Protection (Fuse)
Recommend 10A gG Fuse
Nominal Current Range AC
6 Amp @240VAC
Nominal Current Range DC
0.3 Amp @ 240VDC
Mechanical Compression Force at Closing
20N
Mechanical Compression Force at Closing
8N
Humidity
35-85%
Approvals
CE
Standards
IP40, IEC60947-5-1
Weight
Enclosure Material
UL94V0
Factory Pack Qty
1
TRENT(Fastron) Head Office
Australia
Datasheet
Product Datasheet
Fastron F18FT-4PL 5A 24VDC, 14 Pin Quad Output Relay, From C, 4 x 5 Amp C/O, 250VAC/30VDC Load, 24VDC Coil
Features
4 x 5 Amp @ 250VAC or 30VDC
DIN Rail Mount
Changeover Contact
Compatible with Omron MY4IN Series
UL Approved
CE Compliant to IEC 60664
IP67
Suits F18F-4Z-C5 Socket
Specification
Fastron Part Number
F18FT-4PL 5A 24VDC
Switching Type
4 x 30VDC/250VAC C/O Form C
No of Pins
14
Approvals
UL, CE
Control Voltage
24VDC
Load Current
4 x 5 Amp (rms)
Special Feature
LED Status Indicator
Mounting Style
PCB or Socket Mount
Load Voltage Range
0-250VAC, 0-30VDC
Termination Style
PCB or Socket Mount
Unit Weight
38g
Factory Pack Qty
20
Datasheet
Relay Datasheet
Socket Replacement
F18F-4Z-C5
Fastron Electronics SCT-F24-50-5A-CL2, 5 Amp, 50Amp measurement Split Core CT's CLASS 2 Series Current Transformer
Features
Quick Release Split Core System
Cable Mount
5 Amp Output
Self Powered
Rated System Voltage 0.60/3kV
0.9M Flying Leads
Applications
US Based Metering Equipment
Energy Monitoring
AC Power Control Systems
Power Factor Correction
Power Quality Measurements
Specification
Fastron Part Number
SCT-F24-50-5A-CL2
Technology
Split Core AC Current Transformer
Ratio
50/5 Amp
Aperture Size
ø 24 mm
VA Rating
N/A
Accuracy Class
Class 2
Output
5 Amp (+20%)
Isolation
3kV (AC, 50Hz, 1 min)
Bandwidth
50-60Hz
Mounting Style
Cable Mount/Busbar Mount
Operating Temperature Range
-15°C / 45°C
Continuous Current (max)
50Amp x 1.2
Termination Style
0.9M Flying leads
Unit Weight
100g
Factory Pack Qty
9
Datasheet
Product Datasheet
Application Notes
Installation Guide
TRIB-22D-R-24, 22mm LED Pushbutton & Indicator RED 24AC/DC, Plastic, IEC60947-5-1
Pushbutton Indicator Switches are a combinations of LED indicator Series and Momentary Pushbutton Switches. LED Will activate while the contacts are connected. Widely Used for Rugged Industrial Applications Including Critical Machinery requiring safe operation by the user.
Features :
240VAC or 24AC/DC (400VAC Special Orders)
1 Pole Momentary
LED Illumination
Rated for 6 Amp @ 240VAC, or 0.3 Amp @ 240VDC
Ø 22.5mm Cutout
Standards :
IP40
IEC60947-5-1
CE
Specification
TRENT Part Number
TRIB-22D-R-24
Functions
Momentary
Nominal Voltage
24AC/DC @ 50/60Hz
Impulse Voltage Wear Resistance
6kV
Illumination Type
RED LED
Short Circuit Protection (Fuse)
Recommend 10A gG Fuse
Nominal Current Range AC
6 Amp @240VAC
Nominal Current Range DC
0.3 Amp @ 240VDC
Mechanical Compression Force at Closing
20N
Mechanical Compression Force at Closing
8N
Humidity
35-85%
Approvals
CE
Standards
IP40, IEC60947-5-1
Weight
Enclosure Material
UL94V0
Factory Pack Qty
1
TRENT(Fastron) Head Office
Australia
Datasheet
Product Datasheet
Fastron F18FT-4PL-5A 240VAC + F18F-4Z-C5, 14 Pin Quad Output Relay, From C 4 x 5 Amp, 250VAC/30VDC Load, 240VAC Coil
Features
4 x 5 Amp @ 250VAC or 30VDC
DIN Rail Mount
Changeover Contact
Compatible with Omron MY4IN Series
UL Approved
CE Compliant to IEC 60664
IP67
Suits F18F-4Z-C5 Socket
Specification
Fastron Part Number
F18FT-4PL-5A 240VAC + F18F-4Z-C5
Switching Type
4 x 30VDC/250VAC C/O Form C
No. of Pins
14
Approvals
UL, CE
Coil Voltage
24VDC
Load Current
4 x 5 Amp (rms)
Special Feature
LED Status Indicator
Mounting Style
DIN Rail Mount
Load Voltage Range
0 - 250VAC, 0-30VDC
Isolation
2.5kV
Termination Style
PCB or Socket Mount
Unit Weight
38g
Factory Pack Qty
20
Datasheet
Relay Datasheet
Socket Replacement
F18F-4Z-C5
Relay Replacement
F18FT-4P-L/DC
F18FT-4P-L/AC
Fastron FRI 8-01/5, Current Monitoring Relay AC 0.5 - 5 Amp, Adjustable delay 0.5 - 10 s, 1 x CO 10 Amp, Universal 24-240VAC 24VDC Aux Supply
FRI 8 Series serves to monitor AC currents up to 16 Amp, and provides Relay alarm output with adjustable delay time 0.5 - 10s.
Features :
Suitable for Current Transformer Monitoring
Flexible adjustment by potentiometer, choise of
6 Models: 0.05 - 0.5 A; 0.1 - 1 A; 0.2 - 2 A; 0.5 - 5 A; 0.8 - 8 A; 1.6 - 16 A Adjustable delay 0.5 - 10 s to eliminate short current peaks
Possible to use current scanning from current transformer - up to 600 A Universal supply AC 24 - 240 V and DC 24 V
Supply is galvanically separated from measured current
Output contact: 1 x changeover 8 A
1-phase, 1-MODULE, DIN rail mounting
Applications :
Heating bars in sliding rails
Heating cables
Indication of current flow
Controlling of 1-phase motor consumption
Specification
Fastron Part Number
FRI 8-01/5
Voltage Range
AC 24 - 240 V, DC 24 V (AC 50 - 60 Hz)
Operating Range
-15 %; ? %
Current Range
0.5 - 5 A (AC 50 Hz)
Current Trip Adjustment
Potentiometer
Setting Accuracy
5 %
Burden
max. 1.5 VA
Repeatability
1 %
Temperature Drift
0.1%/??C
Peak Overload (10s)
1.1 x Ipn
Time delay T1
max. 500 ms
Time delay T2
adjustable 0.1-10 s
Output
??
Number of contacts
1x changeover/ SPDT (AgNi / Silver Alloy)
Rating
10 A / AC1
Breaking capacity
2500 VA / AC1, 240 W / DC
Inrush current
10 A
Switching voltage
250 V AC1 / 24 V DC
Min. breaking capacity DC
500 mW
Indication of state
red LED
Mechanical life
1 x 107
Electrical life (AC1)
1 x 105
Other information
??
Operating temperature
-20 ... ? ??C
Storage temperature
-30 ... ? ??C
Electrical strength
4 kV (supply - output)
Operating position
any
Mounting
DIN rail EN 60715
Protection degree
IP 40 from front panel / IP 10 terminals
Overvoltage cathegory
III.
Pollution degree
2
Max. cable size (mm )2
solid wire max. 2x2.5 or 1x4 ; with sleeve max. 1x2.5 or 2x1.5
Dimensions
90 x 17,6 x 64 mm
Weight
69 g
Standards
EN 60255-6, EN 61010-1, RoHS, CE
Datasheet
Product Datasheet
Application Notes
Monitoring relay FRI serves to monitor current level in single phase AC circuits. Due to its fluent adjustment of release current, it is predestined for applications with necessity of current flow indication, and can be used as precedence relay. Output relay is off in normal state. In case the set current level is exceeded, it switches. Multivoltage supply is an advantage.
Trent DSTO-C14-5F-N-1.8M-O-R, Power Distribution Unit (PDU) with IEC Inlet C14 via 1.8M Cable, to 5 x F/C13 Outlet, 240VAC @ 10 Amp with Rocker Switch, Rack Mounted, with Overload Protection, MOQ = 10pcs, Metal Construction
Features
1 x C14 in 5 x F/C13 out, Ganged Distribution Outlet
C14 Socket acc to IEC 60320-1
70 °C pin Temperature
Rocker Switch Protected
Suitable for use in equipment according to IEC/UL 60950
OTHER SIZES CAN BE MADE TO ORDER
Characteristics
UL 60320-1, CSA C22.2 no. 60320-1 (for hot conditions) pin-temperature 70 °C, 10A, Protection Class I
Types for enhanced glow wire test requirements acc. IEC 60695-2- 12 and -13 for the use in unattended household equipment acc. IEC 60335-1
Specification
Trent Part Number
DSTO-C14-5F-N-1.8M-O-R
Rated Voltage
250V
Rated Current
10A
No of Outlets
5
Operating Temperature
-25°C to 120°C
Filter Type
N/A
Overload Protection
YES
Line Switch
Rocker Switch - 10 Amp (red Illumination)
Mounting
Rear Mounted with Plastic Hooks
Material
Powder Coated Metal black, UL 94V-0
Termination Style
1 x C14 Inlet (via 1.8M Cable), 5 x F/C13 Outlet
Weight
2000g
Factory Pack Qty
1
Protection Class
From front side IP30 acc. to IEC 60529
Isolation
2kV (L-N, L/N-E)
VDE/UL/CSA/CE/ROHS
Datasheet
Product Datasheet
Fastron GPH8048ZD3, Solid State Contactor SSR, Single Phase 5-24VDC Control, 80A, 70-480VAC Load, Din Rail Mount
Ratings from 10A to 100 Amp @ 70-480 VAC
Contactor Style for retrofit
SCR output for heavy industrial loads
Zero voltage or instantaneous turn-on outputs
CE Compliant to EN60950-1
IP20
AC & DC control types
Direct bond copper substrate
EMC compliant to Level 3
Direct power lead frame
Spec
Fastron Part Number
GPH8048ZD3
Switching Type
Zero Crossing
ROHS
Yes (Details)
Control Voltage
5-24VDC
Load Current (single unit)
67 Amp (rms) @ 20 Deg C Ambient, 57 Amp (rms) @ 40 Deg C Ambient
Surge Capability
1400 Amp (peak)
Special Feature
Contactor Style IP20 Terminals
Mounting Style
DIN Rail Mount
Load Voltage Range
70 - 480VAC
EMC Compliant
Level 3
Termination Style
Screw
Unit Weight
500g
Factory Pack Qty
20
Datasheet
Product Datasheet
App Notes
Why Use SSR's?
The inside story
Selecting a SSR
DC Output SSR's
Selecting a Suitable Heatsink
Use of Thermal Interface Material
How to Verify the Proper Heatsink
Effect of Forced Air Cooling
Fuse Protection of SSR's
Overvoltage Protection "P" Option MOV
SSR Reliability Whitepaper
3 Phase Motors and Heating Applications
3 Phase Motor Reversing
How to test a SSR
SSR Precautions
SSR Life Expectancy MTBF
ROHS & Reach Statement
Heatsink
SSR and Heatsink Assemblies
Rishabh Rish Xmer 140-100H (45) 2500/5 Class 1 Series Current Transformer
Features
Built In Sealable Terminal Covers
Mounting Feet Supplied
Self Powered
Rated System Voltage 0.72/3kV
IEC185, BS 7626, BSEN 60044-1 and IEC 60044-1
Applications
Metering Equipment
Energy Monitoring
AC Power Control Systems
Power Factor Correction
Power Quality Measurements
Specification
Rishabh Part Number
Rish Xmer 140-100H (45) 2500/5 Class 1
Technology
AC Current Transformer
Ratio
2500/5
Aperture Size
⌀ 86mm or 101 x 31mm Busbar
VA Rating
45VA
Accuracy Class
Class 1
Output
5 Amp AC (+20%)
Isolation
3kV (AC, 50Hz, 1 min)
Bandwidth
50-60Hz
Mounting Style
Panel Mount/Busbar Mount
Operating Temperature Range
-30°C / 85°C
Continuous Current (max)
2500Amp x 1.2
Termination Style
Screw
Unit Weight
1.2kg
Factory Pack Qty
9
Datasheet
Product Datasheet