Schurter 4304.4022 (FKI2-50-2/I), IEC Appliance Inlet C14/M with 1 Stage EMC (RFI) Line Filter
Features
Panel Mount : Screw-on mounting from front side
4 Functions : Appliance Inlet Protection class I, EMC Line Filter 1 Stage, Line Switch 2-pole, Fuseholder for fuse-links 5 x 20 mm 2-pole
Line filter in standard and medical version
Quick connect terminals 6.3 x 0.8 mm
Characteristics
Compact design with optimal shielding
All single elements are already wired
Plug removal necessary for fuse-link replacement
With EMC-shield
Suitable for use in equipment according to IEC/UL 60950
Suitable for use in medical equipment according to IEC/UL 60601-1
Medical Version
M80
Specification
Schurter Part Number
4304-4022 (FKI2-50-2/I)
Rated Voltage
250V
Rated Current
2A
Filter Stages
1 Stage Standard
Operating Temperature
-25°C to 85°C
Filter Type
Differential and Common Mode
Fuse Holder
2 Pole
Line Switch
2 Pole
Mounting
Panel Mount - Case 50
Material
Nickel Plated Steel
Termination Style
C14 Male to Quick Connects
Weight
260g
Factory Pack Qty
1
Protection Class
From front side IP 40 acc. to IEC 60529
Isolation
1.7kV
VDE/UL/CSA/ROHS
Yes
Datasheet
Product Datasheet
Schurter 5008.0006, IEC Appliance Inlet C8 with 1 Stage EMC (RFI) Line Filter, Screw On
Features
Panel Mount : Screw-on or snap-in mounting from front side
2 Functions : Appliance Inlet Protection class II, Line filter in standard and medical version
Solder terminals or quick connect terminals
Characteristics
Compact high performance filter
Suitable for use in equipment according to IEC/UL 60950
Suitable for use in medical equipment according to IEC/UL 60601-1
Other versions on request
Standard version without X-capacitor
Polarized C8 connector
Specification
Schurter Part Number
5008-0006
Rated Voltage
250V
Rated Current
6A
Filter Stages
1 Stage Standard
Operating Temperature
-25°C to 85°C
Filter Type
Differential and Common Mode
Fuse Holder
N/A
Line Switch
N/A
Mounting
Panel Mount - Screw in
Material
Thermoplastic, black, UL 94V-0
Termination Style
C8/Faston
Weight
40g
Factory Pack Qty
1
Protection Class
From front side IP 40 acc. to IEC 60529
Isolation
1.7kV
VDE/UL/CSA/ROHS
Yes
Datasheet
Product Datasheet
Alternatives
version without line filter 2576; 2578
Trent 350NBBF Series 690V, 350 Amp aR Semiconductor I²t Fuse BS88 Style
Features
British Standard Fuse Links Package
Wide Range of I²t
Ratings up to 1050 Amp
Busbar or Standoff Mounting
IEC Standard 60269.1 AND 4
250 V Voltage Rating complying with IEC 33
Applications
Protection of High Powered Semiconductors according to I²t
Short Circuit Protection
DC or AC Motor I²t Protection
Battery Fuse
Specification
Trent Part Number
350NBBF
Fuse Type
I²t AR Class
Nominal Voltage
250VAC @ 50Hz
I²t Rating
31800 A²/s
Nominal Current (RMS + DC)
350 Amp
Tested Breaking Capacity
200kA @ 250VAC
Dimensions
82 x 37.3 x 70.4mm
Hole Centers
65.5 - 48.2mm
Mounting Style
Busbar or Panel Mount with Standoff
Operating Temperature Range
-40°C / 125°C
Watt Loss
49W
Termination Style
M6
Unit Weight
290g
Factory Pack Qty
10
Datasheet
Product Datasheet
Cross Reference Chart