Rishabh Rish Con-I(5A)-F-H-O1A1-O200-D-Z-Z, AC Current Transducer, Input Programmable True RMS 50Hz, 1A-5A Full Scale, 4-20mA, 60-300VAC/DC Supply, with display
Digital output setting 0-20mA/4-20mA/0-10V
Dual output version available
300mS response time
PC 94 UL V0
Input signals can be converted to insulated 4 to 20 mA DC output (for direct current output type)
Each unit needs just 43.75 x 100.9 mm depth DIN Rail cabinet space
Specification
Rishabh Part Number
Rish Con-I(5A)-F-H-O1A1-O200-D-Z-Z
Measurement Output
4-20mA/0-20mA/0-10V User Selectable
Input
1 - 5 Amp 50/60Hz
Overlaod (Continuous)
120%
Overload (1 second)
150%
Operating Temperature
-40 - 70°C
Supply Voltage
60 - 300VAC
Accuracy
0.2%
Response Time
300mS
Termination Style
Screw
Mounting Style
DIN Rail Mount
Safety
IP40/IP20 EN60529 Protection Class II EN61010
Weight
400g
Factory Pack Qty
1
Datasheet
Product Datasheet
Technical Support
Rish Con P setup procedure blog
Schurter DLH-22-0001 Choke
Features
Linear choke
THT-terminals
Inductor vertically positioned in housing
Applications
Smoothing RFI suppression choke
RFI suppression choke
Chopper amplifiers
DC drives and stepper motor controls
Switching power supplies
Specification
Schurter Part Number
DLH-22-0001
Rated Voltage
600V
Rated Current
0.45A
Inductance
5mH
Operating Temperature
-25°C to 125°C
Resistance
2600mΩ
Resonant Frequency
0.2 MHz
Mounting
PCB Mount
Material
Thermoplastic, black, UL 94V-0
Termination Style
THT Terminals
Weight
14g
Factory Pack Qty
1
Climatic Category
40/125/21 acc. to IEC 60068-1
Isolation
2kV
VDE/UL/CSA/ROHS
Yes
Datasheet
Product Datasheet
Application Notes
Schurter 5500-2002 (FPP2-25-2/A), 1 Stage EMC (RFI) Line Filter for Single Phase systems
Features
Line filter for PCB Mounting
1-stage - standard attenuation
Characteristics
Designed for standard applications
Protection against interference voltage from the mains Possible interferences generated in the equipment are strongly attenuated
Universal line filter for standard applications
Suitable for use in equipment according to IEC/UL 60950
Specification
Schurter Part Number
5500-2002
Rated Voltage
250V
Rated Current
2A
Filter Stages
1 Stage
Operating Temperature
-25°C to 85°C
Filter Type
Standard Attenuation
Leakage Current
0.25mA
Mounting
PCB Mount
Material
Thermoplastic, black, UL 94V-0
Termination Style
Solder Pin
Weight
27g
Factory Pack Qty
1
Protection Class
From front side IP 40 acc. to IEC 60529
Isolation
1.7kV
VDE/UL/CSA/ROHS
Yes
Datasheet
Product Datasheet
Schurter 5500-2053, 1 Stage EMC (RFI) Line Filter for Single Phase systems
Features
Line filter in standard and medical version
1-stage - standard attenuation
Characteristics
Designed for standard applications
Protection against interference voltage from the mains Possible interferences generated in the equipment are strongly attenuated
Universal line filter for standard applications
Suitable for use in equipment according to IEC/UL 60950
Other Versions on Request
Version with wire connection
Version with varistor for overvoltage protection
Specification
Schurter Part Number
5500-2053
Rated Voltage
250V
Rated Current
3A
Filter Stages
1 Stage
Operating Temperature
-25°C to 85°C
Filter Type
Very High Symmetrical and Asymmetrical Attenuation
Leakage Current
0.25mA
Mounting
Panel Mount - Case 48
Material
Metal
Termination Style
Screw
Weight
275g
Factory Pack Qty
10
Protection Class
Suitable for appliances with protection class I acc. to IEC 61140
Isolation
1.7kV
VDE/UL/CSA/ROHS
Yes
Datasheet
Product Datasheet
Schurter ITRB-0249-D101, Pulse Transformer
Features
High insulation rating (>3.2 kVAC) between the primary and the secondary windings
High insulation rating up to 500V between the secondary windings
Small coupling capacitances between primary and secondary windings limit transient feedback from the power supply side to the control electronics
The defined partial discharge voltage guarantees an effecively unlimited serviceable live
Applications
Galvanic separation of drive and power-circuit
Mainly used in ignition circuits with Thyristors, Triacs, power transistors and IGBT's
DC/DC converters
Line coupling transformers in high speed data transmission
Specification
Schurter Part Number
ITRB-0249-D101
Rated Voltage
600V
Rated Current (Iz)
100mA
Inductance
1.4mH
Transformer Ratio
1:1:1
Rated Power (Pm)
0.5W
Resistance (RL)
10Ω
Rise Time (Tr)
0.3uS
Operating Temperature
-25°C to 100°C
Mounting
PCB Mount
Material
Thermoplastic, black, UL 94V-0
Termination Style
THT Terminals
Weight
9g
Factory Pack Qty
1
Climatic Category
40/125/21 acc. to IEC 60068-1
Isolation
3.5kV
VDE/UL/CSA/ROHS
Yes
Datasheet
Product Datasheet
Schurter 4304.4022 (FKI2-50-2/I), IEC Appliance Inlet C14/M with 1 Stage EMC (RFI) Line Filter
Features
Panel Mount : Screw-on mounting from front side
4 Functions : Appliance Inlet Protection class I, EMC Line Filter 1 Stage, Line Switch 2-pole, Fuseholder for fuse-links 5 x 20 mm 2-pole
Line filter in standard and medical version
Quick connect terminals 6.3 x 0.8 mm
Characteristics
Compact design with optimal shielding
All single elements are already wired
Plug removal necessary for fuse-link replacement
With EMC-shield
Suitable for use in equipment according to IEC/UL 60950
Suitable for use in medical equipment according to IEC/UL 60601-1
Medical Version
M80
Specification
Schurter Part Number
4304-4022 (FKI2-50-2/I)
Rated Voltage
250V
Rated Current
2A
Filter Stages
1 Stage Standard
Operating Temperature
-25°C to 85°C
Filter Type
Differential and Common Mode
Fuse Holder
2 Pole
Line Switch
2 Pole
Mounting
Panel Mount - Case 50
Material
Nickel Plated Steel
Termination Style
C14 Male to Quick Connects
Weight
260g
Factory Pack Qty
1
Protection Class
From front side IP 40 acc. to IEC 60529
Isolation
1.7kV
VDE/UL/CSA/ROHS
Yes
Datasheet
Product Datasheet
Schurter 5008.0006, IEC Appliance Inlet C8 with 1 Stage EMC (RFI) Line Filter, Screw On
Features
Panel Mount : Screw-on or snap-in mounting from front side
2 Functions : Appliance Inlet Protection class II, Line filter in standard and medical version
Solder terminals or quick connect terminals
Characteristics
Compact high performance filter
Suitable for use in equipment according to IEC/UL 60950
Suitable for use in medical equipment according to IEC/UL 60601-1
Other versions on request
Standard version without X-capacitor
Polarized C8 connector
Specification
Schurter Part Number
5008-0006
Rated Voltage
250V
Rated Current
6A
Filter Stages
1 Stage Standard
Operating Temperature
-25°C to 85°C
Filter Type
Differential and Common Mode
Fuse Holder
N/A
Line Switch
N/A
Mounting
Panel Mount - Screw in
Material
Thermoplastic, black, UL 94V-0
Termination Style
C8/Faston
Weight
40g
Factory Pack Qty
1
Protection Class
From front side IP 40 acc. to IEC 60529
Isolation
1.7kV
VDE/UL/CSA/ROHS
Yes
Datasheet
Product Datasheet
Alternatives
version without line filter 2576; 2578