Rish Xmer 62-30 (40) 250/5 Class 0.2S, 5VA, 31mm Aperture
Features
High Accuracy Class 0.2S
Built In Sealable Terminal Covers
Mounting Feet Supplied
Self Powered
Rated System Voltage 0.72/3kV
IEC185, BS 7626, BSEN 60044-1 and IEC 60044-1
Applications
Metering Equipment
Energy Monitoring
AC Power Control Systems
Power Factor Correction
Power Quality Measurements
Specification
Rishabh Part Number
Rish Xmer 62-30 (40) 250/5 Class 0.2S
Technology
AC Current Transformer
Ratio
250/5
Aperture Size
31x11mm
VA Rating
5VA
Accuracy Class
Class 0.2S
Output
5 Amp AC (+20%)
Isolation
3kV (AC, 50Hz, 1 min)
Bandwidth
50-60Hz
Mounting Style
Panel Mount/Busbar Mount
Operating Temperature Range
-25°C / 40°C
Continuous Current (max)
Ipn x 1.2
Termination Style
Screw
Unit Weight
500g
Factory Pack Qty
9
Datasheet
Product Datasheet
Rish Xmer 62-30 (40) 300/5 Class 0.2S, 5VA, 31mm Aperture
Features
High Accuracy Class 0.2S
Built In Sealable Terminal Covers
Mounting Feet Supplied
Self Powered
Rated System Voltage 0.72/3kV
IEC185, BS 7626, BSEN 60044-1 and IEC 60044-1
Applications
Metering Equipment
Energy Monitoring
AC Power Control Systems
Power Factor Correction
Power Quality Measurements
Specification
Rishabh Part Number
Rish Xmer 62-30 (40) 300/5 Class 0.2S
Technology
AC Current Transformer
Ratio
300/5
Aperture Size
31x11mm (30mm)
VA Rating
5VA
Accuracy Class
Class 0.2S
Output
5 Amp AC (+20%)
Isolation
3kV (AC, 50Hz, 1 min)
Bandwidth
50-60Hz
Mounting Style
Panel Mount/Busbar Mount
Operating Temperature Range
-25°C / 40°C
Continuous Current (max)
Ipn x 1.2
Termination Style
Screw
Unit Weight
500g
Factory Pack Qty
9
Datasheet
Product Datasheet
Fastron FRI 8-01/5, Current Monitoring Relay AC 0.5 - 5 Amp, Adjustable delay 0.5 - 10 s, 1 x CO 10 Amp, Universal 24-240VAC 24VDC Aux Supply
FRI 8 Series serves to monitor AC currents up to 16 Amp, and provides Relay alarm output with adjustable delay time 0.5 - 10s.
Features :
Suitable for Current Transformer Monitoring
Flexible adjustment by potentiometer, choise of
6 Models: 0.05 - 0.5 A; 0.1 - 1 A; 0.2 - 2 A; 0.5 - 5 A; 0.8 - 8 A; 1.6 - 16 A Adjustable delay 0.5 - 10 s to eliminate short current peaks
Possible to use current scanning from current transformer - up to 600 A Universal supply AC 24 - 240 V and DC 24 V
Supply is galvanically separated from measured current
Output contact: 1 x changeover 8 A
1-phase, 1-MODULE, DIN rail mounting
Applications :
Heating bars in sliding rails
Heating cables
Indication of current flow
Controlling of 1-phase motor consumption
Specification
Fastron Part Number
FRI 8-01/5
Voltage Range
AC 24 - 240 V, DC 24 V (AC 50 - 60 Hz)
Operating Range
-15 %; ? %
Current Range
0.5 - 5 A (AC 50 Hz)
Current Trip Adjustment
Potentiometer
Setting Accuracy
5 %
Burden
max. 1.5 VA
Repeatability
1 %
Temperature Drift
0.1%/??C
Peak Overload (10s)
1.1 x Ipn
Time delay T1
max. 500 ms
Time delay T2
adjustable 0.1-10 s
Output
??
Number of contacts
1x changeover/ SPDT (AgNi / Silver Alloy)
Rating
10 A / AC1
Breaking capacity
2500 VA / AC1, 240 W / DC
Inrush current
10 A
Switching voltage
250 V AC1 / 24 V DC
Min. breaking capacity DC
500 mW
Indication of state
red LED
Mechanical life
1 x 107
Electrical life (AC1)
1 x 105
Other information
??
Operating temperature
-20 ... ? ??C
Storage temperature
-30 ... ? ??C
Electrical strength
4 kV (supply - output)
Operating position
any
Mounting
DIN rail EN 60715
Protection degree
IP 40 from front panel / IP 10 terminals
Overvoltage cathegory
III.
Pollution degree
2
Max. cable size (mm )2
solid wire max. 2x2.5 or 1x4 ; with sleeve max. 1x2.5 or 2x1.5
Dimensions
90 x 17,6 x 64 mm
Weight
69 g
Standards
EN 60255-6, EN 61010-1, RoHS, CE
Datasheet
Product Datasheet
Application Notes
Monitoring relay FRI serves to monitor current level in single phase AC circuits. Due to its fluent adjustment of release current, it is predestined for applications with necessity of current flow indication, and can be used as precedence relay. Output relay is off in normal state. In case the set current level is exceeded, it switches. Multivoltage supply is an advantage.
Rishabh Rish Xmer 140-100H (45) 3000/5 Class 0.5 Series Current Transformer
Features
Built In Sealable Terminal Covers
Mounting Feet Supplied
Self Powered
Rated System Voltage 0.72/3kV
IEC185, BS 7626, BSEN 60044-1 and IEC 60044-1
Applications
Metering Equipment
Energy Monitoring
AC Power Control Systems
Power Factor Correction
Power Quality Measurements
Specification
Rishabh Part Number
Rish Xmer 140-100H (45) 3000/5 Class 0.5
Technology
AC Current Transformer
Ratio
3000/5
Aperture Size
⌀ 86mm or 101 x 31mm Busbar
VA Rating
60VA
Accuracy Class
Class 0.5
Output
5 Amp AC (+20%)
Isolation
3kV (AC, 50Hz, 1 min)
Bandwidth
50-60Hz
Mounting Style
Panel Mount/Busbar Mount
Operating Temperature Range
-30°C / 85°C
Continuous Current (max)
3000Amp x 1.2
Termination Style
Screw
Unit Weight
1.2kg
Factory Pack Qty
9
Datasheet
Product Datasheet
Shinko ACR13AA/M TA1 Series Digital Indicating Controllers
• Program control, converter function are standard features
• 5-digit displays suit most industries including Temperature, Humidity, Pressure (0.5s response)
• Drip-proof / Dust-proof IP66 (front panel only)
• 9-step pattern (for SV and time) is a standard feature
• UL/CSA Approved
• Input signals can be converted to insulated 4 to 20 mA DC output (for direct current output type)
• Each unit needs just 60 mm depth panel space
• EC Compliant (Details)
Specification
Shinko Part Number
ACR13AA/M TA1
Control Output
4 - 20mA
Input
Multirange (refer to datasheet)
Alarm
2 x Relay 3A(Resistive), 1A(Inductive load cos Ѳ=0.4)
Option 1
Retransmission (4 - 20mA)
Mounting Style
48 x 96mm Panel Mount
Supply Voltage
100 - 240VAC
Termination Style
Screw
Weight
240g
Factory Pack Qty
1
ROHS
Yes
UL
Yes
CE
Yes
Datasheet
ACR Series Brochure
ACR Series Instruction Manual
ACR Series RS485 Comms Instruction Manual
Delivery 2-3 weeks delivery if not in stock
Rishabh 3PH140-31(40) 400, Class 1 2.5VA 400 Amp, 5 Amp Output, 3 Phase Current Transformer, Panel Mount, Busbar Mount
Features
Built In Sealable Terminal Covers
Mounting Feet Supplied
Self Powered
Rated System Voltage 0.72/3kV
IEC185, BS 7626, BSEN 60044-1 and IEC 60044-1
Applications
Metering Equipment
Energy Monitoring
AC Power Control Systems
Power Factor Correction
Power Quality Measurements
Specification
Rishabh Part Number
3PH105-31(40) 400
Technology
AC Current Transformer
Ratio
400/5
Aperture Size
30 x 36mm
VA Rating
2.5VA
Accuracy Class
Class 0.5 / Class 1
Output
5 Amp AC (+20%)
Isolation
3kV (AC, 50Hz, 1 min)
Bandwidth
50-60Hz
Mounting Style
Panel Mount/Din Rail Mount
Operating Temperature Range
-30°C / 85°C
Continuous Current (max)
400Amp x 1.2
Termination Style
Screw
Unit Weight
1500g
Factory Pack Qty
9
Datasheet
Product Datasheet
Rish Xmer Split Core 2500/5 Amp 195/80 Class 0.5, 25VA Series Current Transformer, 85 x 172mm Aperture
Features
Quick Release Split Core System
Built In Sealable Terminal Covers
Mounting Feet Supplied
Self Powered
Rated System Voltage 0.72/3kV
IEC185, BS 7626, BSEN 60044-1 and IEC 60044-1
Applications
Metering Equipment
Energy Monitoring
AC Power Control Systems
Power Factor Correction
Power Quality Measurements
Specification
Fastron Electronics Part Number
Rish Xmer Split Core 2500/5 195/80
Technology
Split Core AC Current Transformer
Ratio
2500/5
Aperture Size
172 x 85mm
VA Rating
25VA
Accuracy Class
Class 1
Output
5 Amp AC (+20%)
Isolation
3kV (AC, 50Hz, 1 min)
Bandwidth
50-60Hz
Mounting Style
Panel Mount/Busbar Mount
Operating Temperature Range
-25°C / 40°C
Continuous Current (max)
Ipn x 1.2
Termination Style
Screw
Unit Weight
2kg
Factory Pack Qty
9
Datasheet
Product Datasheet
Fastron FCT-D16-5-420, AC Split Core Current Transducer, 16mm Aperture, 0-5 Amp Measurement, 4-20mA Average RMS output, 24VDC Loop Powered, Class 0.5, 50-400 Hz Operation
Features
Average RMS Output
Split Core
4-20mA Current Output
Cable Mounting
24VDC Loop Powered
Isolated plastic case recognised according to UL94-V0
Advantages
Large aperture for cable up to 16mm
High isolation between primary and secondary circuits
Easy installation
Applications
Current Measurement
Energy Management
Motor Control
Actuators
Lamp Failure
Specification
LEM Part Number
AT 5 B420L
Technology
AC Current Transformer
Protection Class
IP50
Supply Voltage
24VDC Loop Powered (10mA)
Load Current (RMS)
5 Amp
Maximum Measurement Current (RMS)
6 Amp
Output
4-20mA (Average RMS)
Isolation
2.5kV (AC, 50Hz, 1 min)
Bandwidth
50 - 400Hz
Mounting Style
Din Rail Mount
Operating Temperature Range
-10°C / 65°C
Accuracy
0.5%
Aperture
16mm
Termination Style
Screw
Approvals
CE,UL,ROHS
Unit Weight
140g
Factory Pack Qty
6
Datasheet
Product Datasheet
Shinko JCL33AR/M Series Digital Indicating Controllers
• Program control, converter function are standard features
• 5-digit displays suit most industries including Temperature, Humidity, Pressure (0.5s response)
• Drip-proof / Dust-proof IP66 (front panel only)
• 9-step pattern (for SV and time) is a standard feature
• UL/CSA Approved
• Input signals can be converted to insulated 4 to 20 mA DC output (for direct current output type)
• Each unit needs just 24 x 48mm panel space
• EC Compliant (Details)
Specification
Shinko Part Number
JCL33AR/M
Control Output
Relay 3A(Resistive), 1A(Inductive load cos Ѳ=0.4)
Input
Multirange (refer to datasheet)
Alarm
1 x Relay Alarm (3A/1A)& 1 x Open Collector(100mA)
Option
None
Mounting Style
24 x 48mm Panel Mount
Supply Voltage
100 - 240VAC
Termination Style
Screw
Weight
120g
Factory Pack Qty
1
ROHS
Yes
UL
Yes
CE
Yes
Datasheet
Download Datasheet
Download Manual
DC-0-5-010-1.0, Hall Effect DC Current Transducer, 0-5 Amp DC, 0-10V Bipolar output, 24VDC supply
Compact and versatile Split Core DC current sensor, 0-5 Amp DC, 4-20 mA Bipolar Output
Other measurement ranges available on request
Features
⌀20mm Aperture
DC Bipolar Measurement
0-10V analogue output
Busbar, or DIN Rail Mounting
Isolated plastic case recognised according to UL94-V0
Advantages
High isolation between primary and secondary circuits
Easy installation
DIN Rail Kit available
Applications
-Automation Systems
Analogue current reading for remote monitoring (e.g. Motor)
-Data Loggers
Self Powered. Will not drain data logger batteries
-Panel Meters
Simple connection displays power consumption
Specification
Fastron Part Number
DC-0-5-010-1.0
Technology
DC Hall Current Sensor with Process Output
ROHS
Yes
Supply Voltage
24VDC
Nominal Current (DC)
0-5 Amp
Response Time
< 1uS
Output
Bipolar 0-10V
Isolation
2.5kV (AC, 50Hz, 1 min)
Bandwidth
DC
Mounting Style
DIN Rail Mount
Operating Temperature Range
-40°C / 85°C
Accuracy
1%
Termination Style
Elevator Terminals
Unit Weight
120g
Factory Pack Qty
6
Datasheet
Product Datasheet
Fastron FRI8-02/1, Under Current Monitoring Relay AC 0.1 - 1 A, Adjustable delay 0.5 - 10 s, 1 x CO 10 Amp, Universal 24-240VAC 24VDC Aux Supply
FRI 8 Series serves to monitor AC currents up to 16 Amp, and provides Relay alarm output with adjustable delay time 0.5 - 10s.
Features :
Suitable for Current Transformer Monitoring
Flexible adjustment by potentiometer, choice of
6 Models: 0.05 - 0.5 A; 0.1 - 1 A; 0.2 - 2 A; 0.5 - 5 A; 0.8 - 8 A; 1.6 - 16 A Adjustable delay 0.5 - 10 s to eliminate short current peaks
Possible to use current scanning from current transformer - up to 600 A Universal supply AC 24 - 240 V and DC 24 V
Supply is galvanically separated from measured current
Output contact: 1 x changeover 8 A
1-phase, 1-MODULE, DIN rail mounting
Applications :
Heating bars in sliding rails
Heating cables
Indication of current flow
Controlling of 1-phase motor consumption
Specification
Fastron Part Number
FRI8-02/1
Voltage Range
AC 24 - 240 V, DC 24 V (AC 50 - 60 Hz)
Operating Range
Current Range
0.1 - 1 A (AC 50 Hz)
Current Trip Adjustment
Potentiometer
Setting Accuracy
5 %
Burden
max. 1.5 VA
Repeatability
1 %
Temperature Drift
0.1%/??C
Peak Overload (10s)
1.1 x Ipn
Time delay T1
max. 500 ms
Time delay T2
adjustable 0.1-10 s
Output
??
Number of contacts
1x changeover/ SPDT (AgNi / Silver Alloy)
Rating
10 A / AC1
Breaking capacity
2500 VA / AC1, 240 W / DC
Inrush current
10 A
Switching voltage
250 V AC1 / 24 V DC
Min. breaking capacity DC
500 mW
Indication of state
red LED
Mechanical life
1 x 107
Electrical life (AC1)
1 x 105
Other information
??
Operating temperature
-20 ... ? ??C
Storage temperature
-30 ... ? ??C
Electrical strength
4 kV (supply - output)
Operating position
any
Mounting
DIN rail EN 60715
Protection degree
IP 40 from front panel / IP 10 terminals
Overvoltage cathegory
III.
Pollution degree
2
Max. cable size (mm )2
solid wire max. 2x2.5 or 1x4 ; with sleeve max. 1x2.5 or 2x1.5
Dimensions
90 x 17,6 x 64 mm
Weight
69 g
Standards
EN 60255-6, EN 61010-1, RoHS, CE
Datasheet
Product Datasheet
Application Notes
Monitoring relay FRI serves to monitor current level in single phase AC circuits. Due to its fluent adjustment of release current, it is predestined for applications with necessity of current flow indication, and can be used as precedence relay. Output relay is off in normal state. In case the set current level is exceeded, it switches. Multivoltage supply is an advantage.