RCS-1800-1000 Three-Phase Flexible Current Sensor System (Rogowski Coils):
The RCS-1800 three-phase flexible rope CT from Magnelab converts AC input current of up to 5000 amperes to an AC output of 0.333 volt.
A 9 to 36 VDC power supply is required to operate these coils. The RCS-1800 comes with an integrator which includes flexible strain relief cables.
Included is an 12 inch circumference rope CT with Integrator, and 8 feet of twisted pair (600V) output leads.
Magnelab Coils come with 10 year warranty
Suitable Alternative to Solar Edge CTRC-07500-1000
Specification
Magnelab Part Number
RCS-1800-1000
Function
AC Current Measurement
Nominal Measurement Current (Ipn)
1000 Amp RMS
Measurement Range
10% - 130% if Ipn
Frequency Measuring Range
50-1500Hz (15th Harmonic)
Operating Voltage
9 - 36VDC
Accuracy
1% from 25 to 1000 Amp
Phase Angle
< 0.5 Degrees
Coil Diameter (⌀)
6 Inch
Coil Circumference
18 Inch
Integrator to Coil Cable
8 Feet Shielded
Maximum Voltage
600V (on bare conductor)
Operating Temperature
-15°C to 65°C
Storage Temperature
-45°C to 80°C
Power Consumption
< 2VA
Overload
20,000 Amp (continuous)
Termination Style
Screw
Weight
1200g
Certification
CE
Factory Pack Qty
1
Certifications
UL Recognized E96927 to IEEE C57.13, CAN/CSA 60044-1
Meets UL STD 61010-1, CAN/CSA C22.2 No. 61010
CE
ROHS
Datasheet
Product Datasheet
Application Notes
RCS/RCT Series Installation Guide
Rish Xmer Split Core 5000/5 Amp 195/80 Class 0.5, 30VA Series Current Transformer, 85 x 172mm Aperture
Features
Quick Release Split Core System
Built In Sealable Terminal Covers
Mounting Feet Supplied
Self Powered
Rated System Voltage 0.72/3kV
IEC185, BS 7626, BSEN 60044-1 and IEC 60044-1
Applications
Metering Equipment
Energy Monitoring
AC Power Control Systems
Power Factor Correction
Power Quality Measurements
Specification
Fastron Electronics Part Number
Rish Xmer Split Core 5000/5 195/80
Technology
Split Core AC Current Transformer
Ratio
5000/5
Aperture Size
172 x 85mm
VA Rating
45VA
Accuracy Class
Class 1
Output
5 Amp AC (+20%)
Isolation
3kV (AC, 50Hz, 1 min)
Bandwidth
50-60Hz
Mounting Style
Panel Mount/Busbar Mount
Operating Temperature Range
-25°C / 40°C
Continuous Current (max)
Ipn x 1.2
Termination Style
Screw
Unit Weight
2kg
Factory Pack Qty
9
Datasheet
Product Datasheet
Rishabh Rish SIGMA 75 CTR5+5/5.CL1.15VA Summation Current Transformer
Features
DIN Rail Mounting Clip Included
Built In Sealable Terminal Covers
Mounting Feet Supplied
Narrow Width (30mm)
Self Powered
Rated System Voltage 0.72/3kV
IEC185, BS 7626, BSEN 60044-1 and IEC 60044-1
Applications
Metering Equipment
Energy Monitoring
AC Power Control Systems
Power Factor Correction
Power Quality Measurements
Specification
Rishabh Part Number
Rish SIGMA 75 CTR5+5/5.CL1.10VA
Technology
AC Current Transformer
Ratio
5+5/5
VA Rating
10VA Class 1
Accuracy Class
Class 1
Output
5 Amp AC (+20%)
Isolation
3kV (AC, 50Hz, 1 min)
Bandwidth
50-60Hz
Mounting Style
Panel Mount/Din Rail Mount
Operating Temperature Range
-30°C / 85°C
Continuous Current (max)
8 Amp
Termination Style
Screw
Unit Weight
500g
Factory Pack Qty
5
Datasheet
Product Datasheet
Rishabh Rish SIGMA 150 CTR5+5+5+5+5+5+5+5+5/5.CL1.5VA Summation Current Transformer
Features
DIN Rail Mounting Clip Included
Built In Sealable Terminal Covers
Mounting Feet Supplied
Narrow Width (30mm)
Self Powered
Rated System Voltage 0.72/3kV
IEC185, BS 7626, BSEN 60044-1 and IEC 60044-1
Applications
Metering Equipment
Energy Monitoring
AC Power Control Systems
Power Factor Correction
Power Quality Measurements
Specification
Rishabh Part Number
Rish SIGMA 150 CTR5+5+5+5+5+5+5+5+5/5.CL1.5VA
Technology
AC Current Transformer
Ratio
5+5+5+5+5+5+5+5+5/5
VA Rating
5VA Class 1
Accuracy Class
Class 1
Output
5 Amp AC (+20%)
Isolation
3kV (AC, 50Hz, 1 min)
Bandwidth
50-60Hz
Mounting Style
Panel Mount/Din Rail Mount
Operating Temperature Range
-30°C / 85°C
Continuous Current (max)
8 Amp
Termination Style
Screw
Unit Weight
500g
Factory Pack Qty
5
Datasheet
Product Datasheet
RCS-2400-1000 Three-Phase Flexible Current Sensor System(Rogowski Coils):
The RCS-2400 three-phase flexible rope CT from Magnelab converts AC input current of up to 5000 amperes to an AC output of 0.333 volt.
A 9 to 36 VDC power supply is required to operate these coils. The RCS-2400 comes with an integrator which includes flexible strain relief cables.
Included is an 12 inch circumference rope CT with Integrator, and 8 feet of twisted pair (600V) output leads.
Magnelab Coils come with 10 year warranty
Specification
Magnelab Part Number
RCS-2400-1000
Function
AC Current Measurement
Nominal Measurement Current (Ipn)
1000 Amp RMS
Measurement Range
10% - 130% if Ipn
Frequency Measuring Range
50-1500Hz (15th Harmonic)
Operating Voltage
9 - 36VDC
Accuracy
1% from 25 to 1000 Amp
Phase Angle
< 0.5 Degrees
Coil Diameter (⌀)
8 Inch
Coil Circumference
24 Inch
Integrator to Coil Cable
8 Feet Shielded
Maximum Voltage
600V (on bare conductor)
Operating Temperature
-15°C to 65°C
Storage Temperature
-45°C to 80°C
Power Consumption
< 2VA
Overload
20,000 Amp (continuous)
Termination Style
Screw
Weight
1200g
Certification
CE
Factory Pack Qty
1
Certifications
UL Recognized E96927 to IEEE C57.13, CAN/CSA 60044-1
Meets UL STD 61010-1, CAN/CSA C22.2 No. 61010
CE
ROHS
Datasheet
Product Datasheet
Application Notes
RCS/RCT Series Installation Guide
RCS-3605-VAR, 5 Amp Output, Class 1 Three Phase 500/1000/2500/5000\10000\25000\50000 Amp AC Measurement 12 Inch Diameter Rogowski Coils with Integrator Flexible Current Sensor System (Rogowski Coils):
The RCS-3605 three-phase flexible rope CT from Magnelab converts AC input current of up to 5000 amperes to an AC output of 5 Amp.
A 24VDC Power Supply is included to operate these coils. The RCS-3605 comes with 5 Amp integrator..
Included is an 36 inch circumference rope CT with Integrator, and power supply.
Magnelab Coils come with 10 year warranty
Specification
Magnelab Part Number
RCS-3605-VAR
Function
AC Current Measurement
Nominal Measurement Current (Ipn)
500/1000/2500/5000\10000\25000\50000 Amp RMS Selectable
Measurement Range
10% - 130% if Ipn
Output Range
0-5 Amp
Frequency Measuring Range
50-1500Hz (15th Harmonic)
Operating Voltage
24VDC
Accuracy
1% from 25 to 5000 Amp
Phase Angle
< 0.5 Degrees
Coil Diameter (⌀)
12 Inch
Coil Circumference
36 Inch
Integrator to Coil Cable
8 Feet Shielded
Maximum Voltage
600V (on bare conductor)
Operating Temperature
-15°C to 65°C
Storage Temperature
-45°C to 80°C
Power Consumption
< 2VA
Overload
20,000 Amp (continuous)
Termination Style
Screw
Weight
3500g
Certification
CE
Factory Pack Qty
1
Certifications
UL Recognized E96927 to IEEE C57.13, CAN/CSA 60044-1
Meets UL STD 61010-1, CAN/CSA C22.2 No. 61010
CE
ROHS
Datasheet
Product Datasheet
Application Notes
RCS-VAR Series Installation Guide
Rishabh Rish SIGMA 75 CTR5+5/5.CL0.5.10VA Summation Current Transformer
Features
DIN Rail Mounting Clip Included
Built In Sealable Terminal Covers
Mounting Feet Supplied
Narrow Width (30mm)
Self Powered
Rated System Voltage 0.72/3kV
IEC185, BS 7626, BSEN 60044-1 and IEC 60044-1
Applications
Metering Equipment
Energy Monitoring
AC Power Control Systems
Power Factor Correction
Power Quality Measurements
Specification
Rishabh Part Number
Rish SIGMA 75 CTR5+5/5.CL0.5.10VA
Technology
AC Current Transformer
Ratio
5+5/5
VA Rating
10VA Class 0.5
Accuracy Class
Class 0.5
Output
5 Amp AC (+20%)
Isolation
3kV (AC, 50Hz, 1 min)
Bandwidth
50-60Hz
Mounting Style
Panel Mount/Din Rail Mount
Operating Temperature Range
-30°C / 85°C
Continuous Current (max)
8 Amp
Termination Style
Screw
Unit Weight
500g
Factory Pack Qty
5
Datasheet
Product Datasheet
Rishabh Shunt 3000A/60mV DC Current Shunt, 60mV output, Form B Class 0.5
Features
Low Cost
Instantaneous measurement
Applications
Industrial Electrical Installatons
Feedback Control
DC Current Measurement
Specification
Rishabh Part Number
Shunt 3000A/60mV
Nominal Current Ipn (DC)
up to 3000 Amp
Overload Capacity
1.2 x Ipn continuous (2 x Ipn 5 seconds)
Mounting Style
Panel Mount
Operating Temperature Range
-25°C / 65°C
Standards
DIN EN 60 051, DIN EN 50 022-35
Unit Weight
up to 7kg
Factory Pack Qty
1
Datasheet
Product Datasheet
Rishabh Rish Xmer 86-50 (45) 1200/5 Class 1 30VA Series Current Transformer
Features
Built In Sealable Terminal Covers
Mounting Feet Supplied
Self Powered
Rated System Voltage 0.72/3kV
IEC185, BS 7626, BSEN 60044-1 and IEC 60044-1
Applications
Metering Equipment
Energy Monitoring
AC Power Control Systems
Power Factor Correction
Power Quality Measurements
Specification
Rishabh Part Number
Rish Xmer 86-50 (45) 1200/5 Class 1
Technology
AC Current Transformer
Ratio
1200/5
Aperture Size
⌀ 46mm or 51 x 12mm Busbar
VA Rating
30VA
Accuracy Class
Class 1
Output
5 Amp AC (+20%)
Isolation
3kV (AC, 50Hz, 1 min)
Bandwidth
50-60Hz
Mounting Style
Panel Mount/Busbar Mount
Operating Temperature Range
-30°C / 85°C
Continuous Current (max)
1200Amp x 1.2
Termination Style
Screw
Unit Weight
0.9kg
Factory Pack Qty
9
Datasheet
Product Datasheet
Rishabh Shunt 250A/60mV DC Current Shunt, 60mV output, Form B Class 0.5
Features
Low Cost
Instantaneous measurement
Applications
Industrial Electrical Installatons
Feedback Control
DC Current Measurement
Specification
Rishabh Part Number
Shunt 250A/60mV
Nominal Current Ipn (DC)
up to 250 Amp
Overload Capacity
1.2 x Ipn continuous (5 x Ipn 5 seconds)
Mounting Style
Panel Mount
Operating Temperature Range
-25°C / 65°C
Standards
DIN EN 60 051, DIN EN 50 022-35
Unit Weight
up to 7kg
Factory Pack Qty
1
Datasheet
Product Datasheet
Rishabh Shunt 500A/75mV DC Current Shunt, 75mV output, Form B Class 0.5
Features
Low Cost
Instantaneous measurement
Applications
Industrial Electrical Installatons
Feedback Control
DC Current Measurement
Specification
Rishabh Part Number
Shunt 500A/75mV
Nominal Current Ipn (DC)
up to 500 Amp
Overload Capacity
1.2 x Ipn continuous (5 x Ipn 5 seconds)
Mounting Style
Panel Mount
Operating Temperature Range
-25°C / 65°C
Standards
DIN EN 60 051, DIN EN 50 022-35
Unit Weight
up to 7kg
Factory Pack Qty
1
Datasheet
Product Datasheet
Rishabh Shunt 200A/200mV DC Current Shunt, 200mV output, Form B Class 0.5
Features
Low Cost
Instantaneous measurement
Applications
Industrial Electrical Installatons
Feedback Control
DC Current Measurement
Specification
Rishabh Part Number
Shunt 200A/200mV
Nominal Current Ipn (DC)
up to 200 Amp
Overload Capacity
1.2 x Ipn continuous (5 x Ipn 5 seconds)
Mounting Style
Panel Mount
Operating Temperature Range
-25°C / 65°C
Standards
DIN EN 60 051, DIN EN 50 022-35
Unit Weight
up to 7kg
Factory Pack Qty
1
Datasheet
Product Datasheet