KNK9053 25KVAR 525V 50HZ, Power Factor Correction Capacitor, 3 Phase, 85 x 265mm Oil Filled, 3 x 96.2uF
Heavy Item - No Free ShippingIskra Doo KNK9053 25KVAR 525V 50HZ, Power Factor Correction Capacitor, 3 Phase, 85 x 265mm Oil Filled, 3 x 96.2uF. Drop In Replacement for Electronicon 275.186-709600 Characteristics and utility 25kVar @ 525V @ 50 Hz 10.0kvar 10kvar Three phase capacitor DUAL WINDING internally delta connected Discharge resistors Incorporated Reactive power factor correction Oil Filled Connector type - Feed through terminals Indoor mounting Triple safety Overpressure disconnection system Protection by internal fuses Self Healing Construction and materials Low losses metallized self-healing polypropylene film, high density, high temperature and greater dielectric resistance Volt/µ UL 94 V0 Resin Aluminium case with bottom fixing M12x16 Standards IEC 60831-1/2 EN 60831-1/2 Specification Iskra Part Number KNK9053 25KVAR 525V 50HZ Technology Oil Filled, Low Loss, Self Healing Dimensions 85 x 265mm Standards IEC 60831-1/2, EN 60831-1/2 Voltage 525V @ 50Hz Kvar 25 Kvar Capacitance 3 x 96.2uF Tolerance On Capacitance -5% + 10% (others on request) Current (In) 44 Amp Overpressure Disconnection System YES Self Extinguishing Resin YES Internal Fuses YES Self Healing YES Mounting M12 x 16mm (Indoor) Operating Temperature Range 50°C Max, 30°C Mean(1 year), 40°C Mean(24 hrs) Lifetime 120,000 Hours Termination Style Double sided Filter Type Terminal Unit Weight 2.5kg Factory Pack Quantity 25 Datasheet Iskra PCF Catalogue Capacitor Datasheet Voltage Derating Tables
-
BA1-ND21-2, Indicator, 48x24mm, 5VDC, 4-20mA Input, 0-100.0 Display Range
BA1-ND21-2, Indicator, 48x24mm, 5VDC, 4-20mA Input, 0-100.0 Display Range 3.5-digit displays suit most industries including Temperature, Humidity, Pressure (0.5s response) Drip-proof / Dust-proof IP66 (front panel only) UL/CE Approved Each unit needs just 40 mm depth panel space EC Compliant Specification Hanyoung Nux Part Number BA1-ND21-2 Control Output 1 (Heat) N/A Control Output 2 (Cool) N/A Input 4-20mA (0-100.0) Alarm N/A Option 1 N/A Mounting Style 48 x 24mm Panel Mount Supply Voltage 5VDC Termination Style Screw Weight 250g Factory Pack Qty 1 ROHS Yes UL Yes CE Yes Datasheet BA1 Series Instruction Manual Free Software Hanyoung Nux TCS Software Hanyoung Nux TCS Software User Manual VX Series SB Driver (Windows 7) Not required for Windows 10 or 11
$69.50
$82.01 inclGST -
DRH3P60A18, 18 Amp AC Semiconductor Motor Controller & Contactor, 90-280VAC Control, 48-600VAC Load, Configuration_Auxiliary 2 x SPST (2 x NO)
Free Aus Post Shipping for $300 spendCrydom DRH3P60A18, 18 Amp AC Semiconductor Motor Controller & Contactor, 90-280VAC Control, 48-600VAC Load, Configuration_Auxiliary 2 x SPST (2 x NO) Features 20 Amp AC Semiconductor Motor Controller Load voltage range up to 600VAC Fits standard 35mm DIN Rail LED input status indicator AC or DC control Zero Voltage (resistive loads) or instantaneous (inductive loads) turn-on output C-UL-US Listed, CCC Certified, IEC Rated, CE & RoHS Compliant, Horsepower Rated Built-in Overvoltage Protection Ultra-efficient thermal management design (Patented) Spec Crydom Part Number DRH3P60A18 Switching Type Zero Crossing Approvals ROHS,CE,ULIEC Control Voltage 90-280VAC Transient Voltage 1200V Load Current (per phase) 18 Amp (rms) Surge Capability (10ms) 650 Amp (peak) Special Feature LED Status Indicator Mounting Style DIN Rail Mount Load Voltage Range 48-600VAC EMC Compliant Level 3 Termination Style Screw Unit Weight 197g Factory Pack Qty 20 Datasheet Product Datasheet App Notes Why Use SSR's? The inside story Selecting a SSR DC Output SSR's Selecting a Suitable Heatsink Use of Thermal Interface Material How to Verify the Proper Heatsink Effect of Forced Air Cooling Fuse Protection of SSR's Overvoltage Protection "P" Option MOV SSR Reliability Whitepaper 3 Phase Motors and Heating Applications 3 Phase Motor Reversing How to test a SSR SSR Precautions SSR Life Expectancy MTBF ROHS & Reach Statement Heatsink SSR and Heatsink Assemblies
-
FBT P BCM12.5 275 RM (4+0), Class I,II / Type 1,2 / B,C, AC Surge Protection Device (SPD) with Remote Contacts, 3 Pole 37.5kA,440VAC, DIN Rail Mount, L/N-PE, L-PEN, L-N, N-PE High Energy MOV Type
Free Aus Post Shipping for $300 SpendTrent FBT P BCM12.5 275 RM (4+0), Class I,II / Type 1,2 / B,C, AC Surge Protection Device (SPD) with Remote Contacts, 3 Pole 37.5kA,440VAC, DIN Rail Mount, L/N-PE, L-PEN, L-N, N-PE High Energy MOV Type Specifications Trent part number FBT P BCM12.5 275 RM (4+0) Nominal Voltage 440VAC No of Poles 4 Category IEC / EN / VDE Class I,II / Type 1,2 / B,C Location of use Main Distribution Boards Protection modes L/N-PE, L-PEN, L-N, N-PE High Energy MOV Additional Remote Contacts YES Protective element MOV Surge discharge rating Imax up to 37.5 kA(10/350us) / 100kA(8/20us) or 12.5kA(10/350us) / 60kA(8/20us) per pole Internal protection and safety Thermal disconnector in each MOV Standards IEC/EN 61643-11 Datasheet Product Datasheet
-
FBT B PVM 150 RM, 150VDC Surge Protection Device for Photovoltaic Systems, Type 2 (Class II) 40kA WITH REMOTE C/O CONTACTS
FBT B PVM 150 RM, 150VDC Surge Protection Device for Photovoltaic Systems, Type 2 (Class II) 40kA WITH REMOTE C/O CONTACTS Specifications Trent part number FBT B PVM 150 RM Nominal Voltage 150VDC No of Poles 3 Category IEC / EN / VDE Type 2 (Class II) Location of use String Box, Inverter Protection modes (+)-PE,(-)-PE,(+)-(-) PE Additional Remote Contacts YES NO/NC/COM Protective element MOV No Fault/Fault Indication Green Flag / Not Green Flag Surge discharge rating Per pole 40kA (8/20uS)9KA) Max, 20kA (8/20uS)9KA) Nominal Internal protection and safety Thermal disconnector in each MOV Weight 420g Standards IEC614643-11:GB/T 18802.11: YD/T 1235.1, CE Datasheet Product Datasheet GDT/MOV/TVS Tester SPD Tester
$129.00
$152.22 inclGST -
FBT B PVM 600 RM, 600VDC Surge Protection Device for Photovoltaic Systems, Type 1 (CLass I) + Type 2 (CLass II) 40kA WITH REMOTE C/O CONTACTS
FBT B PVM 600 RM, 600VDC Surge Protection Device for Photovoltaic Systems, Type 1 (CLass I) + Type 2 (CLass II) 40kA WITH REMOTE C/O CONTACTS Specifications Trent part number FBT B PVM 600 RM Nominal Voltage 600VDC No of Poles 3 Category IEC / EN / VDE Type 1 (CLass I) + Type 2 (CLass II) Location of use String Box, Inverter Protection modes (+)-PE,(-)-PE,(+)-(-) PE Additional Remote Contacts YES NO/NC/COM Protective element MOV No Fault/Fault Indication Green Flag / Not Green Flag Surge discharge rating Per pole 40kA (8/20uS)9KA) Max, 20kA (8/20uS)9KA) Nominal Internal protection and safety Thermal disconnector in each MOV Weight 420g Standards IEC614643-11:GB/T 18802.11: YD/T 1235.1, CE Datasheet Product Datasheet GDT/MOV/TVS Tester SPD Tester
$129.00
$152.22 inclGST -
FBT B PVM 1000 RM, 1000VDC Surge Protection Device for Photovoltaic Systems, Type 1 (CLass I) + Type 2 (CLass II) 40kA WITH REMOTE C/O CONTACTS
FBT B PVM 1000 RM, 1000VDC Surge Protection Device for Photovoltaic Systems, Type 1 (CLass I) + Type 2 (CLass II) 40kA WITH REMOTE C/O CONTACTS Specifications Trent part number FBT B PVM 1000 RM Nominal Voltage 1000VDC No of Poles 3 Category IEC / EN / VDE Type 1 (CLass I) + Type 2 (CLass II) Location of use String Box, Inverter Protection modes (+)-PE,(-)-PE,(+)-(-) PE Additional Remote Contacts YES NO/NC/COM Protective element MOV No Fault/Fault Indication Green Flag / Not Green Flag Surge discharge rating Per pole 40kA (8/20uS)9KA) Max, 20kA (8/20uS)9KA) Nominal Internal protection and safety Thermal disconnector in each MOV Weight 420g Standards IEC614643-11:GB/T 18802.11: YD/T 1235.1, CE Datasheet Product Datasheet GDT/MOV/TVS Tester SPD Tester
$129.00
$152.22 inclGST -
DRC3P48A420, 7.6 Amp AC Semiconductor Motor Controller & Contactor, 208-265VAC Control, 48-530VAC Load, 2 x Solid State NO aux contacts, Zero Crossing
Free Aus Post Shipping for $300 SpendCrydom DRC3 Series AC Motor Controller & Solid State Contactor Features 7.6 Amp AC Semiconductor Motor Controller Load voltage range up to 600VAC Fits standard 35mm DIN Rail LED input status indicator AC or DC control Zero Voltage (resistive loads) or instantaneous (inductive loads) turn-on output C-UL-US Listed, CCC Certified, IEC Rated, CE & RoHS Compliant, Horsepower Rated Built-in Overvoltage Protection Ultra-efficient thermal management design (Patented) Spec Crydom Part Number DRC3R48D420 Switching Type Zero Crossing Approvals ROHS,UL,CE,IEC Control Voltage 208-265VAC Load Current 7.6 Amp (rms) Surge Capability (10ms) 716 Amp (peak) Auxiliary Contacts 2 x NO 1 Amp Solid State Special Feature LED Status Indicator Mounting Style DIN Rail Mount Load Voltage Range 48-530VAC EMC Compliant Level 3 Termination Style Screw Unit Weight 197g Factory Pack Qty 20 Datasheet Product Datasheet App Notes Why Use SSR's? The inside story Selecting a SSR DC Output SSR's Selecting a Suitable Heatsink Use of Thermal Interface Material How to Verify the Proper Heatsink Effect of Forced Air Cooling Fuse Protection of SSR's Overvoltage Protection "P" Option MOV SSR Reliability Whitepaper 3 Phase Motors and Heating Applications 3 Phase Motor Reversing How to test a SSR SSR Precautions SSR Life Expectancy MTBF ROHS & Reach Statement Heatsink SSR and Heatsink Assemblies
-
MCT 250/5 Class 0.5 5VA 50-30 (30), Series Current Transformer, Revenue Grade
Secure MCT 250/5 Class 0.5 5VA 50-30 (30), Series Current Transformer, Revenue Grade Features DIN Rail Mounting Clip Included Built In Sealable Terminal Covers Mounting Feet Supplied Narrow Width (45mm) Self Powered Rated System Voltage 0.72/3kV IEC185, BS 7626, BSEN 60044-1 and IEC 60044-1 Applications Metering Equipment Energy Monitoring AC Power Control Systems Power Factor Correction Power Quality Measurements Specification Secure Part Number MCT 250/5 Class 0.5 5VA 50-30 (30) Technology AC Current Transformer Ratio 250/5 Aperture Size ⌀ 26mm or 34x10mm Busbar VA Rating 5VA Accuracy Class Class 0.5 Output 5 Amp AC (+20%) Isolation 3kV (AC, 50Hz, 1 min) Bandwidth 50-60Hz Mounting Style Panel Mount/Din Rail Mount Operating Temperature Range -30°C / 85°C Continuous Current (max) Ipn x 1.2 Termination Style Screw Certifications CE / ILAC Certified for Billing Unit Weight 300g Factory Pack Qty 9 Datasheet Product Datasheet
$109.00
$128.62 inclGST -
FBT Y PVM 1500 RM, 1500VDC Surge Protection Device for Photovoltaic Systems, Type 2 (Class II) 40kA WITH REMOTE C/O CONTACTS
FBT Y PVM 1500 RM, 1500VDC Surge Protection Device for Photovoltaic Systems, Type 2 (Class II) 40kA WITH REMOTE C/O CONTACTS Specifications Trent part number FBT Y PVM 1500 RM Nominal Voltage 1500VDC No of Poles 3 Category IEC / EN / VDE Type 2 (Class II) Location of use String Box, Inverter Protection modes (+)-PE,(-)-PE,(+)-(-) PE Additional Remote Contacts YES NO/NC/COM Protective element MOV No Fault/Fault Indication Green Flag / Not Green Flag Surge discharge rating Per pole 40kA (8/20uS)9KA) Max, 20kA (8/20uS)9KA) Nominal Internal protection and safety Thermal disconnector in each MOV Weight 420g Standards IEC50539-11 (TUV Approved) Datasheet Product Datasheet GDT/MOV/TVS Tester SPD Tester
$149.00
$175.82 inclGST -
DCBM LEM DC kWh Meter, Class B, DIN Rail Mount, 1000VDC, with 400 or 600 Amp Shunt, IP Enabled, OCMF, DHCP Protocols, PTB Approved for Billing Purposes
Free Aus Post Shipping for $300 SpendDCBM LEM DC kWh Meter, Class B, DIN Rail Mount, 1000VDC, with 400 or 600 Amp Shunt, IP Enabled, OCMF, DHCP Protocols. PTB Germany Approved, or MID Approved for Billing 0-400/600 Amp Shunt Measurement Options (Included) Bi-Directional DC Measurement Voltage Measurement Range 150V to 1150V Backlit LCD 12VDC to 24VDC Supply Voltage Meter Operating Temperature -25°C to 70°C Sensor Operating temperature -40°C to 85°C Busbar Operating temperature 105°C max IP Enabled with DHCP 12 - 24VDC Supply Accuracy Class B The meter is intended for measuring, and monitoring DC electrical power and in particular EV charger networks. The meter records DC power according to the principle of fast sampling of voltage and current signals and is approved for billing purposes. A built-in microprocessor calculates measurands. Features : Measurement of DC kWh Power Graphic LCD with illumination Specification LEM Part Number DCBM400, DCBM600 Functions DC Energy Meter Supply Voltage 12-24VDC Nominal Measurement Range 150VDC to 1000VDC Maximum Measurement Range 150 - 1150VDC Nominal Current Input Shunt Provided IP Conficguration Fixed or DHCP Accuracy Class B Mounting Din Rail Mount Real Time Clock NTP Time Sync over HTTPS/REST Dimensions 96 x 96 x 82mm (2 DIN) Pulse Output Optional Isolation 1000VDC Reinforced (4.4kV Vrms Isolation test), PD2, OVC2, Impulse Withstand Voltage 1.2/50uS at 8kV, Altitude = 2000m Comms HTTPS/REST, Ethernet IP, OCMF/SAFE Signed Data Weight 5/6kg Certification PTB, VDE-AR-E-2418-3-100 Factory Pack Qty 1 Enclosure Material PC/ABS non combustable-self-extinguishability, complying with UL 94 V-0 Enclosure Protection IP20 Operating Temperature -25 →+70°C (Meter), -40 →+85 °C (Busbar 105°C ) Datasheet Product Datasheet Leaflet